DynaLock 8000 Series Brochure

User Manual: DynaLock 8000 Series - Brochure Cut Sheet

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadDynaLock  8000 Series - Brochure
Open PDF In BrowserView PDF
DynaLock
For Life

TM

SM

8000 Series

Stan dard & C u s tom C onsol es

Featuring

Dyna Life

®

Lifetime Warranty

LIFE SAFETY PRODUCTS

DYNALOCK CORPORATION
705 EMMETT STREET, PO BOX 2728, BRISTOL, CT 06011-2728
PHONE: 877-DYNALOCK / FAX: 860-585-0338
E-MAIL: INFO@DYNALOCK.COM / WEBSITE: WWW.DYNALOCK.COM

F U L LY I N T E G R AT E D S E C U R I T Y S Y S T E M S
Electromagnetic Locks
Controls
Power Supplies

3/08

DynaLock
For Life

TM

SM

8000 Series Standard Consoles

8000 Series Custom Consoles

General Description

8000 Series Custom Console Quotation Questionnaire

The 8000SF Series Standard Slope Front Console is designed to provide basic remote monitoring and control of doors equipped
with electromagnetic locks, electric strikes or other similar electronic locking devices. The Console may be ordered with up to 12
individual zones, each consisting of one red and one green LED indicator and one toggle switch.

Complete the following questionnaire. Copy and fax it to DynaLock’s Sales Engineering Department for a prompt price
and delivery quotation. Refer to pages 4 and 5 for further information.

The LED’s provide remote lock and/or door status indication when triggered by a dry contact closure from an external signal switch
included in the locking device or elsewhere on the door or system (i.e. door position contact, alarm sensor, etc.).
The toggle switches may be specified as either maintained or momentary action and provide SPDT dry contacts for lock control
or other remote control functions. The Console is housed in a low profile, slope-front metal enclosure with a powder coated black
front panel. It may be specified to operate on 12 or 24VDC input power.
RED LED
GREEN LED

			

		

RM

			

		
		
Input Voltage:

Electromagnetic

With delay egress

DT			

Electric Deadbolt

Fail-Safe

WM			

Electric Strike

12V

C

1-3

6.5

8.3

3.0

LK

4-5

10.0

8.3

3.0

6-8

14.0

8.3

3.0

Individual Station Type:

T

9 - 12

17.0

8.3

3.0

Type of Control Switch:

Maintained Contact

Fail-Secure

Locks to be controlled have the following options:
Console to: o Control/Monitor

o Door Status

Control Only
TL1

o Lock Status

o Anti-Tamper

Monitor Only

TL2

TL3

L1

L2

L3

Momentary Contact

Light color preferences from top to bottom: (Red, Green, Yellow). (T)
Yes

(M)

(B)

No

Notes

If Yes Audible Signals:

1. If the LED’s are labeled “SECURE” and “UNSECURE”
DynaLock maglocks should include the DYN or HSM
option to control the LED’s.

			
Standard: Audible will sound when condition occurs and continue until condition
				
is corrected.

2. If the LED’s are labeled “CLOSED” and “OPEN”
DynaLock maglocks should include the DSM option to
control the LED’s.

Part Number Configuration
80XXSF - XX - XXX
Number
Of
Stations
01 - 12

Fail-Safe

Number of Stations:

Master Alarm Station with Audible (MA):

LABEL KIT
Kit includes engraved adhesive backed
nameplates to number stations 1 thru 12
and five nameplates to label functions
“SECURE”, “UNSECURE”, “CLOSED”,
“OPEN” and “RELEASE” as required.
(Order Separately)

Fail-Secure

24V

B

Note: All dimensions shown in inches.

Accessories

Type of electric lock(s) to be controlled:

A

C

A

o CSF

No. of Stations

TOGGLE
SWITCH

B

Style of Console:

Toggle Switch Function
MOM = Momentary Action
MAINT = Maintained Action

Door Status (open)

Lock Status (unlocked)

			
Other - Explain: _____________________________________________________
				
_____________________________________________________
Master Alarm Station includes mute switch to silence audible (audible will silence but will be overridden with
new alarm condition) and red power “ON” LED.
Master Override:

MOT

MOK

MOC

Master Lockout:

MLT

MLK

MLC

System Description of Operation: Type on a separate page.

LED Operating Voltage
12 = 12VDC
24 = 24VDC

2

Delay Egress (3101B lock)

7

DynaLock
For Life

TM

SM

8000 Series Custom Consoles

8000 Series Standard Consoles

Custom Console Part Number Configuration

Typical System Wiring

12 or 24VDC
Input

Example:

2

5

5

8002SF Standard
Slope Front Console

8006 CSF - 24 - TL2 - MA - MOC
Door #1
(Magnetic Lock)

Doors require door status switch or lock status sensor for
LED indicator monitoring.

Optional Master Control Stations

Number
Of
Stations

Individual Station Configuration

Specifications
Input Power: 12 or 24VDC @ 0.100 Amps per station.

Console Operating Voltage
12 = 12VDC
24 = 24VDC

Monitoring:

Two (2) LED indicators per station - One (1) Red and One (1) Green.

Control:

One SPDT toggle switch per station.
May be either momentary or maintained action, as ordered.
Output contacts rating: 2 Amps @ 30VDC.

Enclosure/Panel Style

6

Door #2
(Electric Strike)

3

DynaLock
For Life

TM

SM

8000 Series Custom Consoles

8000 Series Custom Consoles

General Description

Individual Station Configuration Selection

8000 Series Custom Consoles are specially fabricated to customer requirements. The factory must be consulted for specific pricing,
delivery and performance specifications. All Consoles, regardless of configuration, share common monitoring and control functions.
DynaLock has developed a universal control module to perform these functions. It satisfies the majority of installations, keeps
initial cost to a minimum and facilitates service.

Select one station configuration - all stations must be identical.

CONTROL
ONLY

MONITORING & CONTROL

MONITORING ONLY

Please refer to page 7 “Custom Console Quotation Questionnaire” before contacting DynaLock for a price
quotation.

Enclosure/Panel Styles
Custom consoles are available in four enclosure
styles. The style selected may be based on customer
preference or dictated by space required for custom
options.

Custom
Slope Front
(CSF)

CSF - Custom Slope Front Series are capable of
performing additional control and monitoring functions
with increased station capacity beyond the standard SF
Series.
DT - Desk Top Series are furnished in blue turretstyle cabinets with brushed aluminum front panels.
Cabinet size and shape are configured to reflect console
function.

T

TL1

TL2

TL3

Optional Master Control Stations
MASTER
ALARM

L1

L2

L3

Console may include one/each of the three options.

MASTER OVERRIDE

MASTER LOCKOUT

WM - Wall Mount Series front panels are furnished in
a brushed aluminum finish and include a removable
steel back-box. Size will vary by number of stations and
options selected.

Desk Top
(DT)

RM - Rack Mount Series consoles are furnished on
standard 19” wide brushed aluminum panels, less backbox. Size will vary by number of stations and options
selected.
Note:
Console style availability may be limited by the number
of station spaces selected. Refer to the selection guide
on page 5 to configure a custom console with the
features desired. Based on your selection DynaLock will
confirm enclosure style availability.

Wall Mount
(WM)

Rack Mount
(RM)

4

MA

MOT

MOK

Allow Two
Station Spaces
Red LED is console
power ON indicator.
Audible is used to
indicate a violation
condition and
includes a audible
mute toggle switch.

MOC

MLT

MLK

Allow Two
Station Spaces
Select one style of Master Override
switch:

• Toggle
• Keyswitch
• Mortise Cylinder

Master Override releases all stations
simultaneously.

5

MLC
Allow Two
Station Spaces

Select one style of Master Lockout
switch:

• Toggle
• Keyswitch
• Mortise Cylinder

Master Lockout disables all individual
station toggle switches.

DynaLock
For Life

TM

SM

8000 Series Custom Consoles

8000 Series Custom Consoles

General Description

Individual Station Configuration Selection

8000 Series Custom Consoles are specially fabricated to customer requirements. The factory must be consulted for specific pricing,
delivery and performance specifications. All Consoles, regardless of configuration, share common monitoring and control functions.
DynaLock has developed a universal control module to perform these functions. It satisfies the majority of installations, keeps
initial cost to a minimum and facilitates service.

Select one station configuration - all stations must be identical.

CONTROL
ONLY

MONITORING & CONTROL

MONITORING ONLY

Please refer to page 7 “Custom Console Quotation Questionnaire” before contacting DynaLock for a price
quotation.

Enclosure/Panel Styles
Custom consoles are available in four enclosure
styles. The style selected may be based on customer
preference or dictated by space required for custom
options.

Custom
Slope Front
(CSF)

CSF - Custom Slope Front Series are capable of
performing additional control and monitoring functions
with increased station capacity beyond the standard SF
Series.
DT - Desk Top Series are furnished in blue turretstyle cabinets with brushed aluminum front panels.
Cabinet size and shape are configured to reflect console
function.

T

TL1

TL2

TL3

Optional Master Control Stations
MASTER
ALARM

L1

L2

L3

Console may include one/each of the three options.

MASTER OVERRIDE

MASTER LOCKOUT

WM - Wall Mount Series front panels are furnished in
a brushed aluminum finish and include a removable
steel back-box. Size will vary by number of stations and
options selected.

Desk Top
(DT)

RM - Rack Mount Series consoles are furnished on
standard 19” wide brushed aluminum panels, less backbox. Size will vary by number of stations and options
selected.
Note:
Console style availability may be limited by the number
of station spaces selected. Refer to the selection guide
on page 5 to configure a custom console with the
features desired. Based on your selection DynaLock will
confirm enclosure style availability.

Wall Mount
(WM)

Rack Mount
(RM)

4

MA

MOT

MOK

Allow Two
Station Spaces
Red LED is console
power ON indicator.
Audible is used to
indicate a violation
condition and
includes a audible
mute toggle switch.

MOC

MLT

MLK

Allow Two
Station Spaces
Select one style of Master Override
switch:

• Toggle
• Keyswitch
• Mortise Cylinder

Master Override releases all stations
simultaneously.

5

MLC
Allow Two
Station Spaces

Select one style of Master Lockout
switch:

• Toggle
• Keyswitch
• Mortise Cylinder

Master Lockout disables all individual
station toggle switches.

DynaLock
For Life

TM

SM

8000 Series Custom Consoles

8000 Series Standard Consoles

Custom Console Part Number Configuration

Typical System Wiring

12 or 24VDC
Input

Example:

2

5

5

8002SF Standard
Slope Front Console

8006 CSF - 24 - TL2 - MA - MOC
Door #1
(Magnetic Lock)

Doors require door status switch or lock status sensor for
LED indicator monitoring.

Optional Master Control Stations

Number
Of
Stations

Individual Station Configuration

Specifications
Input Power: 12 or 24VDC @ 0.100 Amps per station.

Console Operating Voltage
12 = 12VDC
24 = 24VDC

Monitoring:

Two (2) LED indicators per station - One (1) Red and One (1) Green.

Control:

One SPDT toggle switch per station.
May be either momentary or maintained action, as ordered.
Output contacts rating: 2 Amps @ 30VDC.

Enclosure/Panel Style

6

Door #2
(Electric Strike)

3

DynaLock
For Life

TM

SM

8000 Series Standard Consoles

8000 Series Custom Consoles

General Description

8000 Series Custom Console Quotation Questionnaire

The 8000SF Series Standard Slope Front Console is designed to provide basic remote monitoring and control of doors equipped
with electromagnetic locks, electric strikes or other similar electronic locking devices. The Console may be ordered with up to 12
individual zones, each consisting of one red and one green LED indicator and one toggle switch.

Complete the following questionnaire. Copy and fax it to DynaLock’s Sales Engineering Department for a prompt price
and delivery quotation. Refer to pages 4 and 5 for further information.

The LED’s provide remote lock and/or door status indication when triggered by a dry contact closure from an external signal switch
included in the locking device or elsewhere on the door or system (i.e. door position contact, alarm sensor, etc.).
The toggle switches may be specified as either maintained or momentary action and provide SPDT dry contacts for lock control
or other remote control functions. The Console is housed in a low profile, slope-front metal enclosure with a powder coated black
front panel. It may be specified to operate on 12 or 24VDC input power.
RED LED
GREEN LED

			

		

RM

			

		
		
Input Voltage:

Electromagnetic

With delay egress

DT			

Electric Deadbolt

Fail-Safe

WM			

Electric Strike

12V

C

1-3

6.5

8.3

3.0

LK

4-5

10.0

8.3

3.0

6-8

14.0

8.3

3.0

Individual Station Type:

T

9 - 12

17.0

8.3

3.0

Type of Control Switch:

Maintained Contact

Fail-Secure

Locks to be controlled have the following options:
Console to: o Control/Monitor

o Door Status

Control Only
TL1

o Lock Status

o Anti-Tamper

Monitor Only

TL2

TL3

L1

L2

L3

Momentary Contact

Light color preferences from top to bottom: (Red, Green, Yellow). (T)
Yes

(M)

(B)

No

Notes

If Yes Audible Signals:

1. If the LED’s are labeled “SECURE” and “UNSECURE”
DynaLock maglocks should include the DYN or HSM
option to control the LED’s.

			
Standard: Audible will sound when condition occurs and continue until condition
				
is corrected.

2. If the LED’s are labeled “CLOSED” and “OPEN”
DynaLock maglocks should include the DSM option to
control the LED’s.

Part Number Configuration
80XXSF - XX - XXX
Number
Of
Stations
01 - 12

Fail-Safe

Number of Stations:

Master Alarm Station with Audible (MA):

LABEL KIT
Kit includes engraved adhesive backed
nameplates to number stations 1 thru 12
and five nameplates to label functions
“SECURE”, “UNSECURE”, “CLOSED”,
“OPEN” and “RELEASE” as required.
(Order Separately)

Fail-Secure

24V

B

Note: All dimensions shown in inches.

Accessories

Type of electric lock(s) to be controlled:

A

C

A

o CSF

No. of Stations

TOGGLE
SWITCH

B

Style of Console:

Toggle Switch Function
MOM = Momentary Action
MAINT = Maintained Action

Door Status (open)

Lock Status (unlocked)

			
Other - Explain: _____________________________________________________
				
_____________________________________________________
Master Alarm Station includes mute switch to silence audible (audible will silence but will be overridden with
new alarm condition) and red power “ON” LED.
Master Override:

MOT

MOK

MOC

Master Lockout:

MLT

MLK

MLC

System Description of Operation: Type on a separate page.

LED Operating Voltage
12 = 12VDC
24 = 24VDC

2

Delay Egress (3101B lock)

7

DynaLock
For Life

TM

SM

8000 Series

Stan dard & C u s tom C onsol es

Featuring

Dyna Life

®

Lifetime Warranty

LIFE SAFETY PRODUCTS

DYNALOCK CORPORATION
705 EMMETT STREET, PO BOX 2728, BRISTOL, CT 06011-2728
PHONE: 877-DYNALOCK / FAX: 860-585-0338
E-MAIL: INFO@DYNALOCK.COM / WEBSITE: WWW.DYNALOCK.COM

F U L LY I N T E G R AT E D S E C U R I T Y S Y S T E M S
Electromagnetic Locks
Controls
Power Supplies

3/08



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Instance ID                     : uuid:96b76638-73fb-4045-89c3-b35222549fb2
Document ID                     : adobe:docid:indd:fc3207d9-ef62-11dc-b87e-9cf94673cf05
Rendition Class                 : proof:pdf
Derived From Instance ID        : 2f3d5bae-9db9-11dc-b710-cea3893bc57b
Derived From Document ID        : adobe:docid:indd:04e653be-3b8f-11dc-83e1-a9f86950ae7a
Manifest Link Form              : ReferenceStream
Manifest Placed X Resolution    : 300.00
Manifest Placed Y Resolution    : 300.00
Manifest Placed Resolution Unit : Inches
Manifest Reference Instance ID  : uuid:cb85bd68-59cf-11d9-9f34-f62ddc44132e
Manifest Reference Document ID  : adobe:docid:photoshop:cb85bd67-59cf-11d9-9f34-f62ddc44132e
Create Date                     : 2008:03:13 10:05:39-04:00
Modify Date                     : 2008:03:17 14:52:20-04:00
Metadata Date                   : 2008:03:17 14:52:20-04:00
Creator Tool                    : Adobe InDesign CS3 (5.0.2)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 5374 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CS3 (5.0.2)
EXIF Metadata provided by EXIF.tools

Navigation menu