Dynamco TX11 Remote Relay Transmitter User Manual
Dynamco Pty. Ltd. Remote Relay Transmitter
Dynamco >
User Manual
NoslzmImmobiliserUserlnslmclions l‘ ‘ 3 NOSTART USER MANUAL GENERAL DESCRIPTION The NOSTART relay system is designed to replace existing vehicle relays in order to provide vehide immottilieation. No installation work is required, all compatible vehicle relays are removed from the factory designed socket and a NOSTART relay is simply inserted into the empty socket. Specific vehicle notes may be found at mwmnogtettoom SYSTEM TYPES NOSTART systems use either sophisticated code super-position techniques or pseudo random RF code encryption to disarm ltie relay. Once the relay is disanned. it‘s normally closed contade are cloned to complete the immobilised circuit. DISARMING Remote systems: to disarm a NOSTART relay. simptytum the vehicle's ignition switch to the ON position and press the main button on a valid remote control. Digitally Coded Key (DiCK): to disarm the NOSTART relay sinply insert the DiCK into the vehicle's cigarette lighter socket and start the engine. ARMING There is no need to arm the NOSTART relay. All arming functions are controlled by the controller contained inside the relay. - While pm is applied to either pins A or B. while grounding any other pin, the NOSTART is powered up. ~ While power is applied to either C or D, while grounding any other pin. the NOSTART is powered up with ignition ON. ~ The NOSTART will arm immediately when all power is removed. It will re-arm after 30 seconds it the power remains on and ¢12VDC is not detected on pins C or D. EMERGENCY OVERRIDE In cases of lost. stolen or Vault remotes. the NOSTART system comes complete with an over-ride procedure. 1. Simpty insert the vehicle's ignition key into the ignition switch. 2. Turn to the ON position tor a minimum of five seconds. then switch OFF. 3. Repeat step #2 a total 01 five times. Nostart Immobiliser User Instructions ' 2 3 , The NOSTART system will disarm immediately. allowing the engine to start. The NOSTART will re—ann automatimlly as per normal once the ignition is switched oft. To re» start the engine, repeat the entire over-ride procedure. REPLACING BATTERIES IN REHQ‘I’ E CONTROLS Using a small Phillips-head screw driver. removethethreescrewaatthe backofthe remote and carefully separate the no body houshgstakingtakecarencttodiehnbthe circuit board. Remove the old balmy Miltst paying attention to the orientation of the positive and negative terminals, Insert new battery in identical fashion to the original and reassemble remote. Replace news and test remote control by precelng main button. For further information, please contact your local Identimarlr service centre. Remote battery type 27a. SYSTEH DECRIPHON and INSTALLATION CRITERIA The NOSTART is designed to replace any normally open automotive relay, where the connect current does not esceed 20ampe. Different pin layouts are required for different relay manufacturers. Please order as per vehicle requirements. RELAY CONT ACT DESCRIPTIONS ALL PINS - each pin of the NOSTART relay is used to pickup power or ground when either is applied. This process is automatic, hence no polarity considerations are necessary. A PIN: Normally open contact. this pin will act as the output of the relay. Any signal injected into pin 8 will appear on pin A when the NOSTART is disarmed and 4>12VDC is detected on pins C or D. a s12VDC or ground on this pin will act it the same manner and the power supply to a ncnnal immobiliser. 8 PIN : Common contact. this pin will act as the input to the relay contacts. Signals applied to this pin will only appear on pin A when the NOSTART is disarrned and +12VDC is detected on pins C or D. - - Any HZVDC or ground on this pin will act in the same manner and the power supply to a normal immoblllser. C PIN: Coil input, this pin activates the coil inside the NOSTART. If the NOSTART is disam-ed, any 012VDC on this pin will cause the relay contacts to close. - Any +12VDC on this pin will act in the same manner and the ignition to a normal immobiliser a Also any +12VDC or ground on this pin will act in the same manner and the power supply to a normal inmobiliser. D PIN Coil input, this pin aarvates the coil inside the NOSTART. II the NOSTART is disanned. any ~12VDC on this pin will cause the relay contacts to close L) .. Noslarl lmmohiliscr User Instructions - Any 012VDC on this pin will act in the same manner and the ignition to a normal immobiliser. - Also any +12VDC or ground on this pin will act in the same manner and the power supply to a numial immobiliser. NORMALLY OPEN CONTACT WEN/GROUND iGNITlON/GROUND C lGNlTlON/GROUND RELAY COIL SUPPLY RELAY co||_ SUPPLY POWER/GROUND COMMON CONTACT Information to user : Changes of modifications not expressly approved by the manufacture could void the user's authority to operate the equipment. This device complies with Part l5 of the FCC Rules. Operation is subject to the following two condilions: (I) this device may not cause harmful inlerfcrcncc‘ and (2) this device musl acccpl any interference received, including interference that may cause undesired operation.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : Yes Create Date : 2001:05:18 18:20:11 Producer : Acrobat Distiller 4.0 for Windows Modify Date : 2001:05:18 18:20:13-04:00 Page Count : 3EXIF Metadata provided by EXIF.tools