Dyson Dc15 The Ball Animal Owners Manual

2014-08-26

: Dyson Dyson-Dc15-The-Ball-Animal-Owners-Manual dyson-dc15-the-ball-animal-owners-manual dyson pdf

Open the PDF directly: View PDF PDF.
Page Count: 10

DownloadDyson Dyson-Dc15-The-Ball-Animal-Owners-Manual
Open PDF In BrowserView PDF
The Ball User Guide

Please read this guide carefully before using your DC15

1 Assembling
IMPORTANT

• Ensure hose is straight when
inserting wand.

• Please see back of manual for
optional accessories.

• If you have any questions,
please call the Dyson Helpline,
or log onto www.dyson.com

Brush tool

Stair tool

Crevice tool

Slide wand down inside hose
until it clicks.

Slot wand into top of machine
and click into place.

Wind cable anti-clockwise and
secure with clip.

Click tools into place.

2 Using your Dyson
IMPORTANT

• Please note: this machine is
intended for domestic use only.
Fine dust such as plaster dust or
flour should only be vacuumed
in very small amounts.

• The brushbar will automatically
stop if it becomes obstructed.

• Do not press the cyclone release
button while carrying the
machine or it could fall and
cause injury.
• Ensure the cyclone is secured to
the machine.

• Do not shake the machine while
carrying or it could fall and
cause injury.

Carrying your Dyson

Ensure machine is upright
before carrying.

Use the carry handle at the
top of the cyclone to lift.

Using your Dyson

Plug in and press ON/OFF
switch.

Press pedal to release cleaner
head and pull handle towards you.
Use pedal only – do not stand
directly on cleaner head.

Ensure stabilising wheels are
fully retracted or brushbar will
not operate.

3 Using your Dyson
IMPORTANT

• The brushbar will be set to the
ON position every time you
start the vacuum.
• If the brushbar stops during
use, please refer to the
blockages section.

• Ensure stabilising wheels are
fully locked in place when
cleaner is upright before letting
go of the cleaner.
• Do not run over the supply
cable.

Brush control

Press button to turn brushbar
OFF for delicate rugs, looped
carpets and hard floors. Press
again to restart for carpets.

Using DC15

Small movements of the wrist will create a zigzag motion in the
cleaner head, for easier cleaning around furniture.

When finished, push the handle
firmly beyond the upright position
to drop stabilising wheels.

Ensure stabilising wheels are
fully locked in place before
letting go of the cleaner.

4 Using the tools
IMPORTANT

• Ensure machine is in upright
position before using tools.

B

• To protect your floors, the
brushbar will not rotate when
the machine is in an upright
position.

A

• Ensure hair and loose clothing
are kept clear of wand cap
when machine is switched on.

B

• Ensure wand cap is closed,
unless using with tools.

• Powerful suction can cause the
hose to ‘pull back’. Please take
care when cleaning stairs.

A

B

Wand mode

A Lift up wand cap and pull metal wand from inside handle until it clicks.
B Press button to release hose and wand handle from machine. To
push wand back inside hose, ensure hose is straight. Press wand
release button and push wand down into hose.

Hose mode

A First extend the wand, then
press side buttons to remove
wand handle from hose.

B Tools can be fitted directly to
the end of hose or wand.

Stair cleaning

Always work with the machine
at the bottom of the stairs.

5 Washing your filter
IMPORTANT

• Check your filter regularly and
wash at least every six months.
• The filter may require more
frequent washing if vacuuming
fine dust.

A

Remove cyclone from machine.

Lift filter release catch A and
remove filter.

Separate blue filter and
yellow case.

Wash filter and case in cold
water only. Repeat until water
runs clear.

Dry for at least 12 hours. Ensure
filter is completely dry before
refitting onto the machine.

6 Emptying the Clear bin

Recommended for asthma/allergy sufferers

TM

IMPORTANT

• Do not use the machine
without the clear bin in place.
TM

The British Allergy Foundation considers

that this product may in proper use reduce

exposure to both House Dust Mite (Der p 1)
and Cat Allergen (Fel d 1). It is strongly

recommended that a sensitive person should
take care when emptying the clear bin. We
recommend the manufacturer’s emptying
instructions should be strictly followed.

The British Allergy Foundation is a UK

national charity (Charity Re. No. 1003726)
founded in 1991 with the aim of

improving awareness, prevention and
treatment of allergies.

Empty bin as soon as the MAX
mark is reached.
Press catch to release cyclone
and bin from the machine.

Option 1

Push the button as shown to
empty directly into dustbin.

Option 2

Emptying in a bag is recommended
for allergy sufferers.
Place bin in bag and push button.

Let the dust settle and close
bin base securely before
removing from bag and
refitting the bin on the
machine.

7 Cleaning the Clear bin

TM

IMPORTANT

• Do not use detergents, polishes
or freshening products.
• Do not immerse the whole
cyclone in water.

• Ensure parts are completely dry
before replacing.

A

Cleaning the shroud

(optional)

Ensure bin is empty and bin
base is open.

A Press catch to release the
clear bin from the cyclone.
TM

Clean shroud with a cloth or
dry brush to remove fluff.

Cleaning the Clear bin

TM

(optional)

Ensure bin is empty and bin base
is open.
Rinse with cold water only.

Ensure bin is dry before replacing.

Re-assembling the Clear bin

TM

Holding carry handle, fit cyclone
inside the clear bin .
TM

Line up the front and rear guides
and push down to secure.

8 Clearing blockages

A

IMPORTANT

• If any part of the machine
becomes blocked, it may
overheat and then automatically
shut off. Unplug machine and
leave to cool down.

D

• For safety, please lay the
machine on its side before
checking for blockages.

B

E

• Refit all parts of the machine
securely before using it.

• Beware of sharp objects when
clearing blockages.

C
F

A
Check tools, wand and hose are
clear of blockages.
A To remove the hose, rotate
base of hose downwards until
it clicks, then twist away from
the machine.

B

G

C

B Squeeze release catches to
remove the airway inspection
and check inside.
C Pull the top end of the tube
away from machine and
check inside.

D Undo coloured soleplate
fasteners with a coin.

E Rotate endcaps to remove.
F Pull out brushbar sections.

G Cut out debris avoiding bristles.

Maintaining mini turbine head*
(Supplied with certain models or
available as an accessory).

A Undo fasteners and remove
soleplate.

B Remove brushbars and
debris. When re-assembling,
ensure brushbar arrows
match those on central
support C.
*Selected models only.

Important safety information

These items can be used with your DC15. For further information
visit the Dyson website www.dyson.com

5 year guarantee

Take care to ensure objects or
body parts are not inserted into
the cleaner head

Register now for your free 5 year guarantee

1. This appliance is not intended for use
by young children or infirm persons
without supervision. Young children should
be supervised to ensure they do not play
with the appliance or place body parts
near the cleaner head.

Hard floor tool

For improved pick-up
on hard floors.

Stubborn dirt brush
With stiff bristles
for dried-in and
stubborn dirt.

Flexi crevice tool

Extends and flexes
into awkward gaps.

2. The plug must be removed from the
socket outlet before cleaning or
maintaining the appliance.

ONLINE

3. Check to ensure your electricity supply
corresponds to that shown on the rating
plate, which can be found behind the
clear bin . The machine must only be
used as rated.

Just visit

www.dyson.co.uk/register

TM

4. If the supply cable of the cleaner is
damaged, disconnect from the socket
immediately. The cable must be replaced
by Dyson Ltd. or our appointed agent to
avoid a hazard.

Soft bristles to gently
dust around the home.

Mattress tool

Removes dirt and dust
mites from mattresses
and upholstery.

Car turbine head

Cleans pet hair and
fibres from confined
spaces.

6. When vacuuming, certain carpets may
generate small static charges in the clear
bin . These are entirely harmless and not
associated with the power supply.
To minimise any effect from this, do not
insert hand or any object into the clear
bin unless you have first emptied it and
rinsed it with cold water.
TM

TM

7. Do not use the cleaner if any parts
appear to be faulty, missing or damaged.

8. Do not carry out any maintenance work
other than that shown in this manual or
advised by the Dyson Helpline, and do
not put anything into the openings or
moving parts of the machine.

Mini turbine head

Picks up pet hair and
dirt from stairs and
upholstery.

Low reach floor tool
For easier cleaning
under low furniture.

Carpet cleaning kit
Keeps new carpets
looking new.

9. Only use parts recommended by
Dyson; failure to do so could invalidate
your guarantee.

10. If you have a query about your Dyson,
call the Dyson Helpline with your serial
number, which can be found behind the
clear bin .
TM

(UK) 0800 298 0298
(IRL) (01) 475 7109

MAIL

Complete and return the

freepost registration form

We’ll help you choose the right Dyson cleaner and give you any advice and assistance
you need when you’re using it. You can contact us anytime at www.dyson.com or call our team
of experts on UK 0800 298 0298, IRL 01 475 7109 between 7am and 10pm, 7 days a week.

5. Do not use the cleaner if the cable or
plug are damaged or if the cleaner has
been damaged, dropped or has come in
to contact with water or any other liquid.
In these cases, contact the Dyson Helpline.

Soft dusting brush

PHONE

7 days a week

www.dyson.com

Ensure you register for your 5 year guarantee today
DC15 List of patent and patent applications
GB 2407784 A
AU 2005266174
CA 2,575,456
CN 200580025372.9
EP 1786568
IN 323/KOLNP/2007
KR 10-2007-7002254
MY 20053420
NZ 552931
RU 2007107593
TW 94125514
AU 2004294771
CA 2,544,609
CN 200480031447
EP 1680232
HK 06112477.1
IN 1997/DELNP/2006
JP 2006-536152
KR 10-2006-7006143
MY 20044301
NZ 545898
RU 2006120054
TW 93133704
US 10/574,263
AU2002226556
CA 2,439,250
EP1370172
JP 2004-528876
US 2004/0074213 A1
AU2002225209

CA 2,438,073
EP1377197
JP2004-520138
US 6,991,666
AU2002225232
CA 2,438,079
EP1361815
JP 2004-520139
US 6,974,488
GB 2404887 A
AU 2004264703
CA 2,534,344
CN 200480022734.4
EP 1653837
JP 2006-522414
US 10/565,967
AU2002225207
CA 2,438,069
EP1361814
JP 3860541
US 7018439
AU2001240894
EP1268076
JP2003-528704 A
US 6,835,222
AU 637272
CA 2,056,161
EP 0636338
JP1948863
US 5,078,761

AU 2003283157
CA 2,495,053
EP1526796
JP 2004/526998
US 2005-0235454
AU 2003283159
CA 2,495,066
EP 1526797
JP 2004-526999
US 2005-0223516
AU 2003283161
CA 2,495,073
EP1526798
JP 2004-527000
US 10/523246
AU 2005263890
CA 2,574,689
EP 1768537
IN 423/KOLNP/2007
KR 10-2007-7000619
MY 20053365
NZ 552161
RU 2007106708
TW 94124617
US 11/632,851
AU 2005263897
CA 2,574,291
EP 1771104
IN 422/KOLNP/2007
KR 10-2006-7027655

MY 20053364
NZ 552160
RU 2007106901
TW 94124788
US 11/632,821
AU 2005263889
CA 2,572,834
EP 1768536
MY 20053366
US 11/631,109
AU 2005244378
CA 2,567,214
CN 200580015099.1
EP 1748717
JP 2007-510097
MY 20052008
US 11/596321
AU2002233553
CA 2,439,247
EP 1365676
JP 2004-524097 A
US 2004-0078925 A
AU2003252873
CA 2449304
EP1380247
JP 2003-344965
US 2004/0111828 A

GB 3020039
AU 305455
ZL 200530117166.3
IL 40961
US 29/234433

GB 3020040
AU 305454
ZL 200530117096.1
IL 40959
USD 532169

GB 3020041
AU 305456
ZL 200530139953.8
IL 40960
USD 534,324

ED 000281191-0001
ED 000340500

Registered designs and applications

After registering for your 5 year guarantee, your Dyson vacuum cleaner will
be covered for parts and labour for 5 years from the date of purchase,
subject to the term of the guarantee.
If you have any query about your Dyson, call the Dyson Customer Helpline
with your serial number and details of where/when you bought the cleaner.
Your serial number can be found on your rating plate which is behind the
clear bin .
Most queries can be solved over the phone by one of our trained Helpline
staff. If your machine needs attention, we'll aim to send one of our Dyson
engineers to fix it within 3 working days. We won't keep you waiting around
either: our engineers can visit a home or work address - wherever is most
convenient for you.
TM

DC15

Note your serial number for future reference:
FOR PATENT INFORMATION SEE OPERATING MANUAL

230-240V 50Hz
1200 W

02422-01-04

DYSON LIMITED MALMESBURY SN16 ORP ENGLAND UK

JN.15180 PN.08898-06-01 03.12.07

DC15 accessories



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Create Date                     : 2007:12:03 09:44:04Z
Creator                         : QuarkXPress(tm) 6.5
Modify Date                     : 2010:07:08 11:36:19+01:00
X Press Private                 : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%DocumentCustomColors: (PANTONE Cool Gray 3 C).%%+ (Cutter).%%CMYKCustomColor: 0 0 0 .17 (PANTONE Cool Gray 3 C).%%+ 0 1 1 0 (Cutter).%%EndComments
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-21:37:19
Creator Tool                    : QuarkXPress(tm) 6.5
Metadata Date                   : 2010:07:08 11:36:19+01:00
Producer                        : QuarkXPress(tm) 6.5
Format                          : application/pdf
Document ID                     : uuid:51ec46e2-5ce2-4ee2-8d12-87cb11c1f5e2
Instance ID                     : uuid:ac2396d6-b737-b642-a55d-f692ceadab53
Page Count                      : 10
EXIF Metadata provided by EXIF.tools

Navigation menu