ECARE ELECTRONICS ET-132 Wireless Remote Thermometer User Manual Users manual

SHENZHEN ECARE ELECTRONICS CO., LTD Wireless Remote Thermometer Users manual

Users manual

Download: ECARE ELECTRONICS ET-132 Wireless Remote Thermometer User Manual Users manual
Mirror Download [FCC.gov]ECARE ELECTRONICS ET-132 Wireless Remote Thermometer User Manual Users manual
Document ID3297158
Application IDQcH423m3C1hnj0BSmA9JtA==
Document DescriptionUsers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize9.26kB (115764 bits)
Date Submitted2017-02-27 00:00:00
Date Available2017-02-27 00:00:00
Creation Date2017-01-04 15:23:36
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2017-01-04 15:23:36
Document TitleMicrosoft Word - 02469-ef ET132产品说明书FCC.doc
Document CreatorPScript5.dll Version 5.2
Document Author: vincent

Introduction
Congratulations on your purchase of the Professional Remote Cooking Thermometer, a
programmable radio frequency food thermometer. You will now be able to remotely monitor the
time and temperature of food cooking on your grill from anywhere, even in your home.
Components
1. 1 - receiver unit
2. 1 - transmitter unit
3. 1 - detachable stainless steel probe sensor
Receiver Features
LCD (Liquid Crystal Display) – Displays all icons, temperature and timer. The backlight will flash
Blue once the temperature increases 10F, will change to Green when the temperature is within
15F of the set temperature and will turn Red when it reaches the set temperature. See LCD
diagram for detailed information.
CLIP – Battery compartment clip allows you to be mobile. Clip the receiver unit to belt.
BATTERY COMPARTMENT – Holds 2 AAA batteries.
Buttons
1. MODE – Press to select thermometer or timer mode. Press & hold for 2 seconds to register
with the transmitter.
2. HR – In timer mode, press to set hour. Press & hold for 2 seconds, the hours will increase 10
hours per second. In thermometer mode, press to increase the temperature value. Press & hold
for 2 seconds, the temperature value will increase 10 degrees per second.
3. ON-OFF/°F-°C – Press and hold for 2 seconds turns receiver functions on and off. In
thermometer mode press to select temperature readings in Celsius or Fahrenheit.
4. MIN – In timer mode, press to set minutes. Press & hold for 2 seconds, the minutes will
increase 10 minutes per second. In thermometer mode, press to decrease the temperature value.
Press & hold for 2 seconds, the temperature value will decrease 10 degrees per second.
5. MEAT – In thermometer mode, press to select meat type, PROG (program), GBEEF (ground
beef), GPOUL (ground poultry) , BEEF, VEAL, CHCKE (chicken), PORK, POULT (poultry) , LAMB
& FISH. In Timer mode switches between hour/minute timer to a minute/second timer and
back.
6. START STOP– In timer mode, press to start or stop the timer.
7. TASTE – In thermometer mode, select the meat taste level, RARE, MED RARE, MEDIUM, MED
WELL and WELL DONE.
LCD
Transmitter Features
Stand – Fold up stand for easy storage.
Battery Compartment – holds 2 AAA batteries.
Sensor Socket Hole: plug in for stainless steel probe sensor
Buttons
1. ON-OFF/°F-°C – Press and hold for 2 seconds turns transmitter on and off. Press to select
temperature readings in Celsius or Fahrenheit.
Registration Procedures
Open the battery compartment of receiver and insert the two “AAA” batteries. Open the battery
compartment of transmitter and insert the two “AAA” batteries.
The Professional Remote Cooking Thermometer needs the receiver to register the radio frequency
signal from the transmitter.
Transmitter & Receiver are off.
1. Plug the stainless steel probe sensor into the plug in of the transmitter.
2. Turn transmitter on by pressing and holding the ON-OFF/°F°C button for 2 seconds.
3. Turn the receiver on by pressing and holding the ON-OFF/°F-°C button for 2 seconds.
4. Registration is complete when the receiver shows the probe temperature.
Auto Off feature:
The receiver will turn off automatically if it hasn’t receive the temperature signal from the
transmitter for more than 30 minutes ,A beep will sound for one minute before it shuts
down. However, the Auto Off feature will be automatically disabled if the timer is running.
The transmitter will turn off automatically if the temperature measured is always lower than 50
C (122F) in 120 minutes.
Measure meat temperature to USDA doneness temperature range
1. Press MODE to select thermometer mode. The upper display will show a small MEAT and a
meat type such as BEEF.
2. Press MEAT to select meat type. PROG (program), GBEEF (ground beef), GPOUL (ground
poultry), BEEF, VEAL, CHCKE (chicken), PORK, POULT (poultry), LAMB & FISH.
3. Press TASTE to select the level of doneness for the meat type selected. RARE, MED RARE,
MEDIUM, MED WELL and WELL DONE.
Note: The temperature displayed to the right of the actual meat temperature PROBE TEMP will
show the preset temperature TEMP SET according to USDA doneness levels. Example: Beef will
be Well Done at 165 °F.
4. Once the temperature of meat reaches the preset doneness level the receiver will beep and the
LCD backlight will turn red.
Measure meat temperature set to your specific taste
1. Press MODE to select thermometer mode. The upper display will show a small MEAT and a
meat type such as BEEF.
2. Press HR or MIN to raise or lower the set temperature. As you press HR or Min the display
changes to PROG (program). Holding the button will raise or lower the temperature setting
rapidly. Pressing MEAT will return you to the preset USDA ranges.
3. Once the temperature of meat reaches the preset doneness level the receiver will beep and the
LCD backlight will turn red.
Using the Timer
Count down
1. Press MODE to select timer mode. The upper display will show a small TIMER and 0:00.
2. Press HR and MIN button to set the timer. Press START/STOP button to start countdown.
“T” will blink for every second.
3. To stop the countdown process, press START/STOP button. The “T” becomes solid.
4. Press HR & MIN buttons together to clear the setting back to 0:00.
Note: The minimum setting for the timer is 1 minute. When the timer counts down below 1 hour
1:00 the display will change to 59’59” display advising 59 minutes 59 seconds. The seconds will
be shown counting down then. When the countdown reaches 0’00” the timer starts counting up
and it will beep for 60 seconds. The timer and “ST” will blink. Press the START/STOP button to
stop beeping. When the count up reaches 23:59:59 (59 seconds are not displayed) the display
will turn to 0:00, the unit beeps and “ST” will blink for 60 seconds.
Count up
1. Press MODE to select timer mode. The upper display will show a small TIMER and 0:00.
2. Press START/STOP button to start count up. The “S” will blink for every second.
3. To stop the count up process, press START/STOP button. The “S” becomes solid.
4. Press CLEAR button to clear the setting back to 0:00.
Procedure for typical use on an outdoor grill:
The following typical example will go through the steps to have the Professional Remote Cooking
Thermometer alert you to when a beef steak is cooked to medium (USDA doneness level) and
remind you to rotate hot dogs in 5 minutes.
1. Turn on the grill.
2. Follow the registration procedure.
3. Place steak and hot dogs on grill rack.
4. Insert probe sensor into the center of thickest portion of the steak. Avoid touching bone or
heavy fat areas. Assume the meat temperature is 45 °F.
5. Position the probe sensor wire so they will not come into contact with flames and exit the grill
surface area without being pinched/crushed by the grill cover.
6. Stand the transmitter away from heat source of grill. DO NOT put transmitter on closed cover
or under the cover. The transmitter is not waterproof DO NOT use in the rain.
7. Press MEAT so BEEF is displayed.
8. Press TASTE so MEDIUM is displayed and 150 °F will be shown as the TEMP SET.
9. Press MODE to change to timer mode.
10. Press MIN 5 times to set for 5 minutes so that 0:05 is displayed. Press START/STOP to start
the countdown. Press MODE to go back to thermometer mode.
11. Clip the receiver to your belt or pocket and move up to 100 ft away from the outdoor grill. Go
indoors if desired.
12. When 5 minutes are up the receiver will beep for 60 seconds.
13. When the temperature of probe in the steak reaches 55 °F the LCD backlight will flash blue.
14. When the temperature of probe in the steak reaches 135 °F the LCD backlight will flash
green.
15. When the temperature of probe in the steak reaches 150 °F MEDIUM the receiver will beep
and the LCD backlight will flash red.
16. Press STOP to turn off the alert.
15. Turn off grill. Remove the probe sensor from steak. Always wear a heat resistant glove to
touch the stainless steel probe sensor or wire during or just after cooking. Do not touch with
bare hands.
16. Clean the stainless steel probe and dry thoroughly after each and every use.
17. Turn off the transmitter.
HELPFUL HINTS
If the receiver and/or the transmitter display LLL or HHH instead of the probe temperature, wait
for probe to reach room temperature. If LLL or HHH is still displayed it is likely the internal
probe wire has shorted out either through moisture or heat damage.
Using the Timer
Count down
1. Press MODE to select timer mode. The upper display will show a small TIMER and 0:00.
2. Press HR and MIN button to set the timer. Press START/STOP button to start countdown.
“T” will blink for every second.
3. To stop the countdown process, press START/STOP button. The “T” becomes solid.
4. Press HR & MIN buttons together to clear the setting back to 0:00.
Note: The minimum setting for the timer is 1 minute. When the timer counts down below 1 hour
1:00 the display will change to 59’59” display advising 59 minutes 59 seconds. The seconds will
be shown counting down then. When the countdown reaches 0’00” the timer starts counting up
and it will beep for 60 seconds. The timer and “ST” will blink. Press the START/STOP button to
stop beeping. When the count up reaches 23:59:59 (59 seconds are not displayed) the display
will turn to 0:00, the unit beeps and “ST” will blink for 60 seconds.
Count up
1. Press MODE to select timer mode. The upper display will show a small TIMER and 0:00.
2. Press START/STOP button to start count up. The “S” will blink for every second.
3. To stop the count up process, press START/STOP button. The “S” becomes solid.
4. Press CLEAR button to clear the setting back to 0:00.
HELPFUL HINTS
Do not immerse the probe in water while cleaning.
Do not allow the probe or probe wire to come into contact with flames. If cooking with
grill cover closed, only use medium or low heat.
If the probe becomes defective within 90 day warranty period please return defective
probe to address below along with return address and we will send you new probe no
charge.
If the temperature displayed seems to read too high or the temperature seems to increase too
quickly check to make sure the probe tip is not poking through the food to outside. Reposition
the probe tip in the center of the thickest part of food. Avoid touching bone or heavy fat areas.
Cautions:
Always wear a heat resistant glove to touch the stainless steel probe sensor or wire during
or just after cooking. Do not touch with bare hands.
Keep the stainless steel probe sensor and wire away from children.
Not Intended for Use by Persons ages 12 and Under
Clean the stainless steel probe and dry thoroughly after each and every use.
Do not immerse the probe or wire in water. Clean using a damp, soapy cloth.
Do not use the receiver or transmitter in the rain. They are not waterproof.
Do not expose the plug of the stainless steel probe or the plug in hole of the transmitter
to water or any liquid. This will result in a bad connection and faulty readings.
Do not expose the receiver or transmitter to direct heat or surface.
Do not use stainless steel probe in microwave oven.
Cleaning
Always wear a heat resistant glove to touch the stainless steel probe sensor or wire during or
just after cooking. Do not touch with bare hands.
Keep the stainless steel probe sensor and wire away from children.
Wash the metal probe tip with hot soapy water and dry thoroughly. Do not immerse the probe in
water while cleaning.
Wipe the transmitter and receiver with damp cloth. Do not immerse either in water.
FCC Notice
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
NOTE 1: This equipment has been tested and found to comply with the limits for a Class B
digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does
cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
NOTE 2: Any changes or modifications to this unit not expressly approved by the party
responsible for compliance could void the user's authority to operate the equipment.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Creator Tool                    : PScript5.dll Version 5.2
Modify Date                     : 2017:01:04 15:23:36+08:00
Create Date                     : 2017:01:04 15:23:36+08:00
Format                          : application/pdf
Title                           : Microsoft Word - 02469-ef ET132产品说明书FCC.doc
Creator                         : vincent
Document ID                     : uuid:a7897ae2-f8d6-4531-9976-14229af1ae55
Instance ID                     : uuid:4091a2e5-000b-443f-a9e3-1d2bdfc5037d
Page Count                      : 7
Author                          : vincent
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AATPET-132