ECO Wireless ST001 Wireless Sentinel Transceiver User Manual Manual rev

ECO Wireless, LLC. Wireless Sentinel Transceiver Manual rev

Manual rev

1 9/15/2009
Sentinel Transceiver User’s Manual
Getting Started
The Sentinel Wireless Transceiver module consists of the following hardware:
Sentinel transceiver unit (integrated into Relume lamp assembly)
RF Antenna
Power Cable (Integrated into Relume lamp power supply)
Interface Cable (available for special installation requirements)
Installation:
The Sentinel transceiver is shipped pre-installed in the Relume lamp assembly. The antenna is shipped
separately to avoid damage. The antenna MUST be installed on the lamp assembly before the assembly
is powered up and tested.
Setup Instructions:
1. Mount the lamp assembly with the Sentinel transceiver. Do not apply power
2. Screw the antenna firmly to the antenna mount on the top of the lamp assembly
3. Apply power to the lamp assembly
4. Test for correct system operation
FCC Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device
does not cause harmful interference.
Note: This equipment has been tested and complies with Part 15 and Part 90 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful interference. This equipment
generates, uses, and can radiate radio frequency energy, and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, try to correct the interference by one or more of
the following measures:
• Reorient or relocate the equipment.
• Increase the separation distance between the affected equipment and receiver.
• Consult ECO Wireless, LLC for help.
Any changes or modifications to this equipment not expressly approved by ECO Wireless, LLC could void
the authorization to operate the equipment.
RF Exposure Information
2 9/15/2009
This equipment complies with the FCC RF radiation requirements for controlled environments. To
maintain compliance with these requirements, the antenna and any radiating elements should be
installed to ensure that a minimum separation distance of 20cm is maintained from the general
population.
Professional Installation
Changes or modifications not expressly approved by the party responsible for compliance could void
the user's authority to operate the equipment.
Industry Canada
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment
Regulations.
Operation is subject to the following two conditions: (1) this device may not cause harmful interference,
and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l'interférence canadienne
causant des règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce
dispositif peut ne pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle
interférence reçue, y compris l'interférence qui eut causer l'opération peu désirée.
3 9/15/2009
Sentinel Municipal Light Software Basic Operating Commands
This is a summary of the commands available on the Sentinel software.
EDIT
LAMPS
ADD – open this dialog to add a new lamp (requires Internet access)
DELETE – open this dialog to delete an existing lamp (requires Internet access)
MODIFY – open this dialog to modify an existing lamp (requires Internet access)
GROUPS
ADD GROUP – open this dialog to add a new group
DELETE GROUP – open this dialog to delete an existing group
SET GROUP(s) FOR A LAMP – open this dialog to add a lamp to an existing group
SET LAMP TO EMERGENCY – open this dialog to set a group to emergency flashing mode
CANCEL LAMP EMERGENCY – open this dialog to can a group from emergency flashing mode
VIEW
ZOOM IN
ZOOM OUT
ZOOM FULL
ZOOM LAST
PAN
SPECIAL CONTROL
ALL LAMPS – open this dialog to set all lamps to the same operating state
GROUP – open this dialog to set any group to the same operating state
SINGLE – open this dialog to control a single lamp
Mousing over any lamp on the map will display status for that lamp. Right clicking on any lamp in the
list view at the bottom will bring up basic lamp commands and provide the user with the ability to
center that lamp on the map.
4 9/15/2009
Lamp Control commands
To control the lamps, use the SPECIAL CONTROL section of the menu.
SPECIAL CONTROL
ALL LAMPS – open this dialog to set all lamps to the same operating state
GROUP – open this dialog to set any group to the same operating state
SINGLE – open this dialog to control a single lamp
The operation options are to control all lamps in the area, a pre-defined group of lamps, and a single
lamp. The control menu window appears to allow the user to control the two light outputs on the
Sentinel lamp controller.
Use the mouse to move the sliders to control the Output1 (white for San Jose) and Output2 (Yellow for
San Jose) light amplitude to the required level. Click OK to send the signal.
The menu is the same for Group control and Single control
You can also control single lamps by selecting them from the list on the bottom of the screen and using a
right mouse click to bring up an option window
5 9/15/2009
Select control lamp to display the control window for the selected lamp. The lamp can be controlled as
described previously.
Map Control commands
To maneuver around in the included map, use the view controls in the menu or the map control buttons
in the upper left side of the Municipal Light software window
VIEW
ZOOM IN
ZOOM OUT
ZOOM FULL
ZOOM LAST
PAN
To zoom in or out, select the option from the menu or click on the control button. To activate the zoom,
left click with the mouse in the map area.
Use the “hand” to pan to a new place on the map by left clicking and holding while moving the mouse
after selecting the pan (hand) control.
Select the “arrow” in the far left location to exit the map control and select items on the map again.
Notice that when the mouse is positioning over a lamp in the map with a close zoom, information about
the lamp is displayed in an information window
6 9/15/2009
Group Control commands
Group commands are used to modify the settings of many lamps with a single command. Groups can be
created, edited, and controlled from the group menu
GROUPS
ADD GROUP – open this dialog to add a new group
DELETE GROUP – open this dialog to delete an existing group
SET GROUP(s) FOR A LAMP – open this dialog to add a lamp to an existing group
SET LAMP TO EMERGENCY – open this dialog to set a group to emergency flashing mode
CANCEL LAMP EMERGENCY – open this dialog to can a group from emergency flashing mode
Group setup is part of the initial lamp configuration and should not be used by the average user
Edit Lamp commands
Edit lamp commands are used to add new lamps to the database of available lamps.
7 9/15/2009
EDIT
LAMPS
ADD – open this dialog to add a new lamp (requires Internet access)
DELETE – open this dialog to delete an existing lamp (requires Internet access)
MODIFY – open this dialog to modify an existing lamp (requires Internet access)
Edit Lamp setup is part of the initial lamp configuration and should not be used by the average user

Navigation menu