EDU Science 139ELA Remote Control Toy Transmitter User Manual
EDU Science Co., Ltd. Remote Control Toy Transmitter
User Manual
TM
FOR AGES 10 AND UP
INSTRUCTIONS / PRECAUTONS
1
WARNING!
- C AUTION: E lectrically operated product. Not recommended for children under
10 years of age. As with all electric products , precautions s hould be observed
during handling and use to prevent electric shock.
- K eep face, eyes, fingers , hair, body parts etc. away from the propeller and
other moving parts .
- Always fly the Vectron Ultralite in an open s pace.
- Do not expose your V ectron Ultralite to rain or moisture.
- Do not fly in a crowded environment.
- Do not fly in a dusty area.
- Do not fly in complete darkness.
- E nsure people know that you are flying the V ectron Ultralite.
- Use only your Ultralite controller included in this package.
- Always turn your Vectron Ultralite "OF F " when not in use.
General
- Y our Vectron Ultralite must not be used if there is any damage to the
AC adaptor, charging cord, charging socket, rechargeable battery, propeller,
ring or other parts of the Vectron Ultralite.
- Do not attempt to lift objects with your V ectron Ultralite.
- Vectron Ultralite is a high tech precision instrument and is vulnerable to misus e
P rotecting all components is an essential part of flight maintenance.
- This toy is not intended for children under 3 years old.
- The instruction manual contains important information and must be kept.
- This toy only operates with s upplied AC adaptor.
- The us e of the AC adaptor should be supervised by an adult and examined regularly.
- This toy must not be used if there is any damage to the power cord, plug and other
parts of the transformer.
- The AC adaptor mus t be disconnected before cleaning.
AC Adaptor Important Information
3
8
Battery Care
- F or maximum performance, always allow your battery of the V ectron Ultralite to
drain before recharging.
- Never charge a second time without discharging first. T his will affect or damage
the battery.
- Do not dispos e of the battery in your regular household waste.
- C ontact your local waste management officials for information on environmentally
sound dis posal of rechargeable batteries.
- If a battery leak develops, avoid contact with leaking fluid. P lace the damaged
battery in a plastic bag for proper disposal.
- If fluid comes in to contact with skin or eyes, wash with cool water for at least 15 mins.
Battery Disposal
- Y our Vectron Ultralite is only to be charged under adult s upervision.
- Never expose the Vectron Ultralite battery pack to direct sun, hot areas, or fire
as it may explode.
- The Ultralite charger and battery may become warm during charging.
- The Ultralite charging cord must be disconnected from the Vectron Ultralite when
it is fully charged.
- Never leave your Vectron Ultralite connected to the AC adaptor overnight.
- Never overcharge the Vectron Ultralite as it can damage the rechargeable battery.
Battery Safety TIPS:
- For your first flight, ensure there are no strong air currents from
fans, air conditioners or open windows.
- Adjust the trigger to find the correct position so your Vectron
Ultralite will hover preventing it from flying too high or too low.
It will take some practice to get the hang of it.
- Always point the thrust transmitter towards your Vectron Ultralite
to ensure a steady controllable flight.
- Do not try to land your Vectron Ultralite on to the launch platform.
Try to land on any open floor area.
- Your Vectron Ultralite can also take off from any smooth flat surface.
Do not try to take off from deep pile carpet or soft furniture. This
may jam the propeller before take off.
L earning More About Y our Vec tron Ultralite
Vectron Ultralite F lying R ange 50 ft. (15 m)
T echnical S pec ifications
9V (6LR 61)
alkaline batteries
Ultralite C ontroller B atteries
P ower C onsumption 0.3 W (P eak)
10 and UP
R ecommended Age
Working Voltage (DC ) 6.5 V ~ 9 V
Working Voltage 5 V
Working C urrent 8 W (P eak)
R echargeable Battery Type 6 V 100mA Ni-MH
Ultralite C harging Devices
I) AC Adaptor Output DC 13V 0.6A
AC Adaptor Input 120V AC 60Hz 10W
C harge Duration 10 minutes (max.)
- V detect plus mas ter timeout
C harge Method
Battery Removal
- R emove the 3 s crews on the top of the Vectron Ultralite with a P hilips
screwdriver, disassemble the unit and remove the rechargeable battery.
(1)
CLOSE OPEN
(2) (3) (4)
2
9
Y our Vectron Ultralite
does not res pond to the
thrus t transmitter.
The thrust transmitter battery is low.
The red LE D does not flash after
depres sing the trigger.
R eplace the 9V (6LR 61) Alkaline
battery with new one.
The thrust transmitter battery is
inserted improperly.
C heck and reins ert the battery with the
proper polarity as per the markings in
the holder.
Y our Vectron Ultralite is out of range. Move clos er to your Vectron Ultralite.
NOT E : T he trans parent labels underneath the ring are for protection
agains t the propeller. A damaged ring can be repaired with trans parent
tape. S ome glues may damage the polyfoam ring.
Y ou are outdoors or flying in a large
room with high ceiling.
F ly indoors with the appropriate ceiling
height.
Troubleshooting
Y our AC Adaptor is the wrong type or
damaged preventing it from charging
your Vectron Ultralite.
C ontact your support team at
service@ bhsciencetech.com stating the
voltage and plug type required. Do not
return your Vectron Ultralite to the retail s tore.
The propeller auto-stop feature is
activated. T his feature is activated
when the propeller is obstructed
by body parts or objects. If your
Vectron Ultralite crashes on to the
floor, this may trigger the auto-stop
feature as well. The red and green
LE D will blink alternately.
R es et your Vectron Ultralite by switching
it off and turning it back on again to resume
flight.
P roblem P os s ible C aus e S olution
Y our Ultralite battery is not charged. C harge your battery fully before flying.
The battery power is low. R echarge the battery fully.
Y our Vectron Ultralite is not placed
properly onto the launch platform.
P lace your V ectron Ultralite properly s itting in
the middle of the launch platform.
Y our Vectron Ultralite is out of range.
The green LE D does not come on
which means there is no signal
transmiss ion.
Move clos er to your Vectron Ultralite.
The trigger is not depres sed far
enough on the thrus t trans mitter.
Depres s the trigger at leas t half way.
The room may have drafts from
windows , fans, air conditioner and
ventilation s ys tems.
Minimize the drafts before take off.
Operator error. Wait for the red LE D to flas h before trying
to take off.
Y our Vectron Ultralite
does not take off.
No power to the propeller.
S lide the power switch to the ON position.
P ower switch is not turned on.
Battery Safety Guidelines
- To prevent battery leakage: B e sure to insert batteries correctly.
- B atteries should be replaced by adult.
- Never dispose of batteries in fire as this may caus e them to explode.
- Do not mix old and new batteries (replace all batteries at the same time).
- Do not mix Alkaline, standard (C arbon-Zinc) or rechargeable
(Nickel-C admium) batteries (or equivalent). Only batteries of the same
or equivalent type as recommended are to be used.
- Non-rechargeable batteries are not to be recharged.
- Always remove exhaus ted or dead batteries from product. R emove
batteries from product which is not going to be us ed for a long time.
Otherwise the batteries may leak and cause damage.
- The supply terminals are not to be s hort-circuited.
- Make sure battery compartment is secure.
- Do not immerse battery operated toys. W ipe clean only.
6
II) Flight Preparation
1) P lace your V ectron Ultralite on to
the launch platform.
WA R NING : Never recharge your Vectron Ultralite a second time
without having flown first. Continuous recharging without
discharging first, will damage the Ultralite battery.
CAUTION: Always recharge your Vectron Ultralite with supplied
AC Adaptor! Operate with third-party AC Adaptor may cause
damage to this product.
2)
NOT E S :
- The red and green LED will blink alternately. It will take
approximately 10 minutes to charge your Vectron Ultralite
completely; at this point the green LED will flash continuously.
- When your Vectron Ultralite is new or has not been flown for a long
time it will take several charge/discharge cycles for the battery to
reach its full flight time.
E ns ure your Vectron Ultralite is
switched OF F , then connect the
charging cord to your Vectron
Ultralite.
IMP OR T ANT :
a) Ensure the AC Adaptor voltage and plug is suitable for your area.
b) Connect the AC Adaptor to the wall outlet.
5
I) Thrust Transmitter
2) Insert one size "9V" (6LR 61)
Alkaline batteries.
Trigger
P ower On Indicator
1) Open or close the cover with
a P hilips screwdriver.
CLOSE OPEN
Antenna
74
Contents
Auto-stop
S afety
P ropeller
AC Adaptor
Thrus t Trans mitter
L aunch P latform
R echargeable
B attery
R ed
LE D
G reen
LE D
P ower S witch
(ON / OF F )
Ring
C harging
S ocket
NOTE: After the red and green LED blink alternately, the red LED
will start to flash slowly. At this time your Vectron Ultralite is ready
for take off.
III) Flying, Hovering and Landing
Your Vectron Ultralite
1) 2) S witch on your V ectron Ultralite.
IMPORTANT: Ensure your Vectron Ultralite is fully charged for first
time use and that you have a least 10 ft. (3 m) of clear area.
3) P ress the trigger to
control your V ectron
Ultralite.
NOTE: Flying Range is
around 50 ft.(15 m)
ON
OFF
With your V ectron Ultralite on
the launch platform, unplug
the charging cord.
15 meter
15 meter
Attention to maximize the life of your Vectron
Ultralite
- Avoid continuously running at full power against a low ceiling, as this will shorten
the saucers motor life.
- nstead hover and swoop below ceiling height or fly outdoors if wind condition
permits.
- This will insure many hour of flying fun with your Vectron ultralite.
NOTE:
THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV
INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS
EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER AUTHORITY
TO OPERATE THE EQUIPMENT.