EDU Science MS079 Wireless IP WiFi Digital Microscope User Manual MS079 MANUAL C6

EDU Science Co., Ltd. Wireless IP WiFi Digital Microscope MS079 MANUAL C6

User Manual

Wireless IP WIFI Digital MicroscopeUser Manual8+
Main body Charger 1 Stand x1    USB cable x1Adapter (for tripod) x1Main body x1 Prepared slide x1LED button (Backlight control)Micro USB portFront BackUSB / OFF / WiFi mode switchZoom in / outLens Parts list Low battery (red light)Charging (red light)Full batterySwitch o Steady BlinkingTurn o the device(Wireless IP WiFi Digital Microscope)
How to connect with USB and WiFi 2Blue Light FlashingSSID: Camera-ESL-xxxxxxPassword: 88888888IP viewerOpen a web browser and enter the address in the address bar, then hit Enter.  To avoid interference with other hardware change the Camera name/ Password/ Channel , click save and reboot button. Please wait to reboot and try to follow these steps to reconnect.1. Reboot Wi microscope to take eect2. Connect to wireless network             with SSID - New camera name/ New password3. Browse http://192.168.100.1 Address: http://192.168.100.1 WiFi MODE12  CaptureLED ON / OFF* Recommended to connect a maximun 4 devices at the same time.SSID: Camera-ESL-xxxxxx (Series No)Password: 88888888After switch to WiFi mode, the unit will be ready for connecting till Blue Light Flashingxxxxxx
3How to connect with USB and WIFI 1USB MODE2**SKYPE viewer 3Photo Booth viewer (Mac only)Open Photo Booth       Camera        Camera-ESLCamera-ESL**Download and Install SKYPETo download the SKYPE software, please visit SKYPE website for instructions of installation and how to use it. www.skype.comGreen light in USB mode  The green LED will ash during data transfer in USB modefor MacOpen Skype       Preferences       Audio/video      Camera-ESLfor windowsOpen Skype       Call       Audio Settings      Camera-ESL
4WiFi Microscope with stand and slideBAABPress       for a second to turn Backlight       onAIf you want to turn the Backlight  B  o, press  A  for a second again BSlideSlideMain bodyAB12ABFocus
WiFi Microscope with adapter (for tripod)5* Tripod not includedZoom In/Out12345
6Firmware Upgrade1.  Download & Extract compressed “ rmware xxxxxx-MS079"       from http://www.edu-science.com/downloads.php?type=software2.  Turn o the Wire (Wireless IP Wi Digital Microscope)3.  Connect the USB cable from the ”Wireless IP Wi Digital Microscope” to the PC.4.  Press and Hold the "LED" button for 5 seconds while selecting the "wi" mode.5.  Upon successful installation, a new Hard Disk Drive will be shown as "System" & "Application"6.  Delete all les in the "System's" in the Hard Disk Drive7.  Copy and Paste the compressed "rmware xxxxxx-MS079" les to the "System"8.  Turn o the “Wireless IP Wi Digital Microscope”Firmware Upgrade
• BATTERY INSIDE THE WIFI DIGITAL MICROSCOPE IS NOT REPLACEABLE.FCC NOTE: FCC ID:Q6NMS079This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS  OR CHANGE TO THIS EQUIPMENT. SUCH MODIFICATIONS OR CHANGE COULD VOID THE USER’S AUTHORITY TO OPERATE THE EQUIPMENT.This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help.This equipment complies with the FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20cm between the radiator and any part of your body.• Rechargeable batteries are only to be charged by supervisory adult or children over 8 years.Wireless IP Wifi Digital MicroscopeModel No.: MS0790070General SpecicationImage sensor : Main processor :Image size :Magnication: Power source : Battery life : Charger : USB port : Wireless standards : Wireless range : Supported devices : Software requirements :Device Lifespan Operating conditions : OmniVision, 1/5 inch, 2.0 MP, CMOS sensor240Mhz ARM926 CPU1280*720(USB) & 640*480(WiFi)Basic 8x (3.5” LCD) and variable for larger LCD screensInternal 1100mAh lithium-ion battery2 hours5V adapter or USB power sourceUSB 2.0 (USB 1.1 compatible)IEEE 802.11n,IEEE 802.11g,IEE 802.11b10m indoors, 30m outdoorsAndroid & iOS phones, tablets, notebooksWeb browser(WiFi), Skype(USB)2 yearsCommercial grade0 to +50˚C20% to 95%Hereby, Edu-Science (C.P.) Ltd. , declares that this Wireless IP WIFI Digital Microscope is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC.This equipment should be installed and operated with a minimum distance of 20cm between the radiator and your body.P38-MS079-81001000