EUROTECH MRG1005 Multi-Service Gateway & Edge Controller User Manual ReliaGATE 10 05 x4

EUROTECH SpA Multi-Service Gateway & Edge Controller ReliaGATE 10 05 x4

Contents

User manual

Original User ManualReliaGATE 10-05-34Multi-Service Gateway & Edge ControllerRev. 1-0 — 13 May 2016 — REGATE-10-05-34_UserMan_EN_1-0 — ENGLISH
TrademarksAll trademarks and registered trademarks are the property of their respective owners.Revision historyRevisionDescriptionDate1-0First release13 May 2016© 2016 Eurotech SpA - Via Fratelli Solari 3/A - 33020 AMARO (UD) - Italy
ReliaGATE 10-05-34 User Manual Rev 1-0Table of contents3/ 62TABLE OF CONTENTSTrademarks2Revision history2Tableof contents31ImportantInformation71.1Signals used inthis document71.2 Disclaimer ofliability81.3Intended audience82SafetyInstructions92.1Observe antistatic precautions92.2 Connectpower supply correctly93 How to receive technical assistance 113.1 How to receive technical support 114 Conventions used in this document 134.1 Conventions for signal names 134.2 Abbreviations for direction and electrical characteristics of a signal 135 Product overview 155.1 Product labels 166 Declaration of Conformity 176.1 FCC Class A notice 176.2 RoHS compliance 176.3 WEEE compliance 177 Technical Specifications 198 Getting started 219 Product interfaces 239.1 Front panel interfaces 239.1.1 DIP switch selector functions 239.1.2 8-position connector functions 239.2 Rear panel interfaces 249.3 LED indicators 259.4 Service panel interfaces 2610 Interfaces in detail 2710.1 Power supply 2710.1.1 Power supply parameters 2710.1.2 Power supply connector pinout 2710.1.3 How to turn ON the ReliaGATE 10-05-34 2710.1.4 How to turn OFF the ReliaGATE 10-05-34 2710.1.5 How to manage the ReliaGATE 10-05-34 power consumption 2710.1.6 How to perform a power reset of the ReliaGATE 10-05-34 2810.2 Wi-Fi and Bluetooth 2910.2.1 Wi-Fi specifications 2910.2.2 Bluetooth specifications 2910.3 Cellular 3010.4 The MicroSIM card receptacle 3010.5 Ethernet port 31
Table of contentsReliaGATE 10-05-34 User Manual Rev 1-04 / 6210.5.1 Connector pinout 3110.5.2 Port specifications 3110.6 Host USB port 3210.6.1 Connector pinout 3210.7 COM ports 0 and 1 3310.7.1 How to insert RS-485 fail-safe and termination resistors 3310.7.2 COM ports pinout 3410.8 The MicroSD card receptacle 3510.9 Console port 3610.9.1 Connector and mating connector specifications 3610.9.2 Connector pinout 3610.10 RTC (Real Time Clock) 3710.10.1 The RTC device "/dev/rtc1" 3710.11 Watchdog 3810.11.1 How to enable / disable the watchdog 3810.12 The Programmable pushbutton 3811 The Software 3911.1 The Linux OS distribution 3911.2 The bootloader procedure 3911.2.1 How to select the Linux kernel sources 3911.2.2 How to set up a correct eMMC card partition 3912 How to access the interfaces under Linux 4112.1 Ethernet port 4112.2 Wi-Fi and Bluetooth 4112.3 Modem 4112.4 COM ports 0 and 1, Console port 4112.4.1 How to test a COM port 4112.5 LED indicators 4212.5.1 How to manage a LED 4212.6 Flash Memory 4312.7 RTC 4412.7.1 How to manage the timestamp registers 4412.7.2 How to manage the user-available byte 4412.7.3 How to manage the sleep mode (example) 4512.8 Watchdog 4612.8.1 How to manage the watchdog using the C programming language 4612.8.2 How to manage the watchdog from the command line 4612.8.3 How to obtain further information 4712.9 The Programmable pushbutton 4713 How to log in the Administration Console 4913.1 How to login using the Console port 4913.2 How to login via Secure Shell (SSH) 4913.2.1 How to login if your development PC is running Linux 4913.2.2 How to login if your development PC is running Windows 4913.3 How to change your security settings 5014 Eurotech M2M / IoT solutions 5114.1 Everyware Software Framework (ESF) 5114.2 The ESF Web UI 5114.3 Everyware Cloud (EC) 5214.4 For further information 5215 Mechanical specifications 5315.1 ReliaGATE 10-05-34 mechanical dimensions 53
ReliaGATE 10-05-34 User Manual Rev 1-0Table of contents5/ 6215.2 Mounting bracket mechanical dimensions 5416 How to install the product 5516.1 How to install the ReliaGATE 10-05-34 using the Mounting Bracket 5516.2 Optional: How to install the ReliaGATE 10-05-34 using the DIN Rail Mounting Kit 5616.2.1 How to replace the Mounting Bracket with the DIN Rail Mounting Kit 5616.2.2 How to install the ReliaGATE 10-05-34 on a DIN rail 5816.2.3 How to remove the ReliaGATE 10-05-34 from a DIN rail 5817 How to maintain the product 5917.1 Use antistatic precautions 5917.2 Remove the power supply 5917.3 Inspect the installation of the product 5917.4 Clean the product 59Notes 61
(This page has been intentionally left blank)
ReliaGATE 10-05-34 User Manual Rev 1-01 Important Information7/ 621 IMPORTANT INFORMATIONCAREFULLY READ AND UNDERSTAND THE INSTRUCTIONS CONTAINED IN THISDOCUMENT BEFORE INSTALLING / OPERATING THE PRODUCT.KEEP THIS DOCUMENT FOR FUTURE REFERENCE.Whenever you have any doubt regarding the correct understanding of the instructions contained in thisdocument contact your local Eurotech Technical Support Team (see the last page of this document forfurther details).To lower the risk of personal injury, electric shock, fire or damage to equipment, observe the followingprecautions, as well as using good technical judgment, whenever installing / operating the product.1.1 Signals used in this documentDANGERINDICATES A HAZARD WITH A HIGH LEVEL OF RISK WHICH, IF NOT AVOIDED, WILLRESULT IN DEATH OR SERIOUS INJURYWARNINGINDICATES A HAZARD WITH A MEDIUM LEVEL OF RISK WHICH, IF NOT AVOIDED, COULDRESULT IN DEATH OR SERIOUS INJURYCAUTIONINDICATES A HAZARD WITH A LOW LEVEL OF RISK WHICH, IF NOT AVOIDED, COULDRESULT IN MINOR OR MODERATE INJURYNOTICEIndicates practices not related to personal injury, such as:lAn instruction to follow to use the product effectivelylA statement of company policy related to product or property protection
8 / 621 Important Information ReliaGATE 10-05-34 User Manual Rev 1-01.2 Disclaimer of liabilityEurotech has reviewed the contents of this document to ensure accuracy and consistency with thehardware and software described.Always refer to the latest available manual revision available at: www.eurotech.com.1.3 Intended audienceThis document is intended for system developers, who are skilled persons with a thorough knowledge ininstalling and implementing computer systems, networks, and related operating software.
ReliaGATE 10-05-34 User Manual Rev 1-02 Safety Instructions9/ 622 SAFETY INSTRUCTIONSObserve the following safety instructions when installing / operating the product.Failure to comply with these instructions or with specific warnings elsewhere in this document violatessafety standards of design, manufacture, and intended use of the product.Eurotech assumes no liability for any failure to comply with these instructions.2.1 Observe antistatic precautionsNOTICEPREVENTING ELECTROSTATIC DISCHARGE (ESD)When handing the product described in this document, always use appropriateantistatic precautions to avoid damages due to electrostatic discharge.For example: use a wrist strap or ESD cuff kept in constant contact with bare skinand attached to an ESD ground.2.2 Connect power supply correctlyWARNINGELECTRIC SHOCK HAZARDBefore applying power, thoroughly review all installation, operation, and safety instructions.Failure to supply power correctly, or failure to follow all operating instructions correctly, maycreate an electric shock hazard, which could result in personal injury or loss of life, and / ordamage to equipment or other property.To avoid injuries:lBefore operating any equipment, carefully read any supplied instructionslDo not perform any connections with wet handslCheck any power cords for damage before using themlUse certified power cables. The power cables must meet the power requirements of thedevicelPosition cables with care. Avoid positioning cables in places where they may betrampled or compressed by objects placed on themlTake particular care of plugs, power-points and outlets. Avoid overcharging themlAlways disconnect power and discharge the circuits before touching themlOnly start the product with a power supply that meets the requirements stated on thevoltage label. In case of uncertainties about the required power supply, contact theEurotech Technical Support Team (see the back cover for full contact details) or theelectricity authority.
(This page has been intentionally left blank)
ReliaGATE 10-05-34 User Manual Rev 1-03 How to receive technical assistance11 / 623 HOW TO RECEIVE TECHNICAL ASSISTANCE3.1 How to receive technical supportIf you have technical questions, or if you cannot isolate a problem with your product, or for any inquiryabout repair and returns policies, contact:lThe Eurotech Global Support Center: https://eurotech.desk.com/lYour local Eurotech Technical Support Team: see the back cover for full contact details.
(This page has been intentionally left blank)
ReliaGATE 10-05-34 User Manual Rev 1-04 Conventions used in this document13 / 624 CONVENTIONS USED IN THIS DOCUMENT4.1 Conventions for signal namesConventionDescriptionGNDDigital ground plane#Active low signal_PPositive signal in differential pair_NNegative signal in differential pair4.2 Abbreviations for direction and electrical characteristics ofa signalConventionDescriptionISignal is an input to the systemOSignal is an output from the systemIOSignal may be input or outputPPower and groundAAnalog signal3.33.3 V signal level55 V signal levelNCNo ConnectionReservedUse is reserved to Eurotech
(This page has been intentionally left blank)
ReliaGATE 10-05-34 User Manual Rev 1-05 Product overview15 / 625 PRODUCT OVERVIEWThe ReliaGATE 10-05-34 is a compact and lightweight device intended to be used as Multi-Service IoTGateway. It is based on the NXP i.MX285 CPU, with 512MB of RAM, 4GB of eMMC, and a user-accessible microSD slot.It is suitable for intensive workload in industrial applications. It supports a 9 to 36 V power supply withtransient / surge / noise / reverse polarity protection, two protected serial ports (RS-232 and RS-485), andone noise and surge protected USB port. An internal battery provides up to 30/50 minutes of uptime andallows for a safe system shutdown in case of a blackout.The ReliaGATE 10-05-34 can be equipped with Everyware™ Software Framework (ESF), a commercial,enterprise-ready edition of Eclipse Kura, the open source Java/OSGi middleware for IoT gateways.The ReliaGATE 10-05-34 can also take advance of Everyware Cloud (separately available). EverywareCloud (EC) is a specialized cloud solution that allows you to easily connect, configure and manage yourdevice through all its life-cycle.A Development Kit is available upon request. It allows you to quickly and easily start the development ofyour applications.Figure 5.1 - The ReliaGATE 10-05-34
5 Product overviewReliaGATE 10-05-34 User Manual Rev 1-016 / 625.1 Product labelsThe product label is placed on the bottom side of the product.Ref#Label contentLabel example1• ReliaGATE model number• ReliaGATE serial number• WEEE symbol• CE mark• Ethernet MAC address• IMEI number• FCC ID numbers• Power details
ReliaGATE 10-05-34 User Manual Rev 1-06 Declaration of Conformity17 / 626 DECLARATION OF CONFORMITYThe ReliaGATE 10-05-34 conforms to the following:lReduction of Certain Hazardous Substances (RoHS2)lCE MarklWi-Fi and Bluetooth Radio:oCE - EN300 328 (2.4GHz ISM), EN50371 (EMI), EN301 489 (EMC)oFCC - 15.209 (General RF device), 15.247 & 15.249 (2.4GHz ISM)lCellular Radio:oFCC PART 22, 24 & 27 and suitable GSM radio certificationslIEC/UL 60950-1 Information Technology Equipment - Safety - Part 1: General RequirementslProduct compliance with part 15.21 of FCC6.1 FCC Class AnoticeConditions of operationThis product complies with Part 15 of the FCC Rules.Operation is subject to the following two conditions:1. This product may not cause harmful interference2. This product must accept any interference received, includinginterference that may cause undesired operation.FCC Radio FrequencyInterference statementThis product has been tested and found to comply with the limits for aClass A digital device, pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection against harmfulinterference when the equipment is operated in a commercial environment.This equipment generates, uses, and can radiate radio frequency energy,and if it is not installed and used in accordance with the instruction manual,Modificationsit may cause harmful interference to radio communications.Operation of this equipment in a residential area is likely to cause harmfulinterference, in which case the user will be required to correct theinterference at his own expense.Any modifications made to this product that are not approved by Eurotechmay void the authority granted to the user by the FCC to operate thisproduct.Product FCC IDs FCC ID: UKMMRG1005Contains FCC ID: XPYLISAU201STATEMENT:1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:(1)This device may not cause harmful interference.(2)This device must accept any interference received, including interference that may cause undesiredoperation.2. Changes or modifications not expressly approved by the party responsible for compliance could void theuser's authority to operate the equipment.Note: This equipment has been tested and found to comply with the limits for a Class A digital device,pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection againstharmful interference when the equipment is operated in a commercial environment. This equipmentgenerates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with theinstruction manual, may cause harmful interference to radio communications. Operation of this equipment in aresidential area is likely to cause harmful interference in which case the user will be required to correct the
6 Declaration of ConformityReliaGATE 10-05-34 User Manual Rev 1-018 / 62interference at his own expense.FCC Radiation Exposure StatementThis equipment complies with FCC radiation exposure limits set forth for an uncontrolledenvironment. This equipment should be installed and operated with minimum distance of 20 cmbetween the radiator and your body.6.2 RoHS complianceThe product described in this document, including all its components and its sub-assemblies, have beenmanufactured in compliance with the Directive 2011/65/EU of the European Parliament and of the Councilof 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronicequipment.6.3 WEEE compliance
ReliaGATE 10-05-34 User Manual Rev 1-06 Declaration of Conformity19 / 62In compliance with the Directive 2012/19/EU of the European Parliament and of the Councilof 4 July 2012 on waste electrical and electronic equipment (WEEE), the symbol on the right,shown on the product or within its literature, indicates separate collection for this electricaland electronic equipment (EEE) that has been placed on the market after 2005.This product, at the end of its life cycle, must be collected separately and managed inaccordance with the provisions of the current Directive on waste electrical and electronicequipment.Because of the substances present in the product, improper use or disposal of the refusecan cause damage to human health and the environment.To avoid any possible legal implications, contact your local waste collection body for fullrecycling information.
(This page has been intentionally left blank)20 / 627 TECHNICAL SPECIFICATIONSSpecificationsDescriptionProcessorCPUNXPi.MX285, 454MHz, 1 coreMemoryRAM512 MB, DDR2StorageEmbedded4GBeMMCOther1x MicroSD slot (user accessible)I/O InterfacesEthernet1x Fast Ethernet portUSB1xUSB2.0 Host port (Noise and Surge Protected)COM1x RS-232 (3-wire, Surge Protected)1x RS-485 (Surge Protected, with Termination and Fail-safe Resistors)1x Console port (RS-232Serialport)Radio interfacesCellular3Gglobal (integrated)Wi-Fi / BT802.11b,g,n / 4.0 BLEAntennas (external)1x SMA: Cellular1x RP-SMA:Wi-Fi / BluetoothOtherRTCYesExternal WatchdogYesUPSIntegrated Li-ionBattery(3.7V, 48mAh), Safe shutdown and Power state restoreLEDs1x Power1x Cellular activity2x User configurableButtons1x Reset, 1x ProgrammableSIM slot1x MicroSIM (user accessible)PowerInputNominal: 24 V dc; Range: 9 - 36 V dc with Transient, Surge, Noise, ReversePolarity, Overvoltage protectionConsumption1.5 W idleEnvironmentOperating Temp0 °C to +50 °CStorage Temp-40 °C to +85 °CCertificationsRegulatoryCE, FCCSafetyIEC/UL 60950-1EnvironmentalRoHS2; REACHRadioCE - EN 300 328 (2.4GHz ISM), EN 50371 (EMI), EN 301489 (EMC)FCC - 15.209(GeneralRF device), 15.247 & 5.249 (2.4GHz ISM)CellularPTCRBFCC PART 22, 24 & 27 and suitable GSM radio certificationsIngressIP40MechanicalEnclosureMaterial:ABS(Color: blue) and AluminumDimensions112 (L) x 68 (W) x 37 (H); mmWeight180 g (Mounting Bracket included)MountingMounting Bracket (Optional: DIN Rail Mounting Kit)
ReliaGATE 10-05-x4 User Manual Rev 1-08 Getting started21 / 62
ReliaGATE 10-05-34 User Manual Rev 1-08 Getting started21 / 628 GETTING STARTEDFollow these steps to get started with your ReliaGATE 10-05-34:1. Know the ReliaGATE 10-05-34 interfaces.The ReliaGATE 10-05-34 provides connectivity to several wired and wireless interfaces.For further information, see:l"Product interfaces" on page 23l"Interfaces in detail" on page 272. Apply power to the ReliaGATE 10-05-34.The ReliaGATE 10-05-34 supports a variety of usage scenarios.For further information, see "Power supply" on page 273. Log into the Administration console.The ReliaGATE 10-05-34 runs a Linux distribution based on a Yocto framework and supports loginvia a variety of methods.For further information, see:l"The Software" on page 39l"How to log in the Administration Console" on page 49l"How to access the interfaces under Linux" on page 414. Install the ReliaGATE 10-05-34.The ReliaGATE 10-05-34 is lightweight and compact. You can easily install it, even on a DIN rail.For further information, see:l"Mechanical specifications" on page 53l"How to install the product" on page 555. Start developing your applications.Your ReliaGATE 10-05-34 supports ESF, which is an inclusive software framework that puts amiddleware layer between the operating system and the OEM application.For detailed instructions, and sample applications for developing device applications using ESF onEurotech platforms, see: http://esf.eurotech.com/docs.
(This page has been intentionally left blank)
ReliaGATE 10-05-34 User Manual Rev 1-09 Product interfaces23 / 629 PRODUCT INTERFACESThis section gives you an overview of the interfaces available on the ReliaGATE 10-05-34.9.1 Front panel interfacesThe interfaces available on the front panel are the following:Figure 9.1 - Front panel interfaces layoutRef#DescriptionConnector / Mating connector information1DIP switch selector-28-position connectorConnector: Base strip, Header;8-pin, 3.5 mm pitchMating connector: Pluggable screw terminal block;8-pin, 3.5 mm pitchExample:• Shenzhen Connection Electronics Co., Ltd.• P/N: PLTB1.5-08-BF-3.50-GYTable 9.1 - Rear panel interfaces description9.1.1 DIP switch selector functionsUse the DIP switch selectorto:lInsert the RS-485 fail-safe resistorslInsert the RS-485 termination resistorslControl the Boot sequencelEnable the watchdog9.1.2 8-position connector functionsUse the 8-position connectorto:lConnect the power inputlConnect the RS-485 Serial portlConnect the RS-232 Serial port
9 Product interfacesReliaGATE 10-05-34 User Manual Rev 1-024 / 629.2 Rear panel interfacesThe interfaces available on the rear panel are the following:Figure 9.2 - Rear panel interfaces layoutRef#DescriptionConnector / Mating connector information1Cellular antenna connectorConnector: Female SMAMating connector: Male SMA2USB 0 host portConnector: USB Type-A socketMating connector: USB Type-A plug3Ethernet 0 portConnector: Female RJ-45Mating connector: Male RJ-454Wi-Fi/BT antenna connectorConnector: Female RP-SMAMating connector: Male RP-SMATable 9.2 - Rear panel interfaces description
ReliaGATE 10-05-34 User Manual Rev 1-09 Product interfaces25 / 629.3 LED indicatorsThe available LED indicators are the following:Figure 9.3 - LED indicators layoutRef#UseColor1POWER:- LED ON: ReliaGATE powered by the external source- LED OFF: ReliaGATE not powered by the external sourceBlue2CELL (Cellular modem activity):- LED ON means modem ON;- LED blinking means modem attached to GSM networkGreen3USER1 (General purpose)Green / Amber4USER2 (General purpose)Green / AmberTable 9.3 - LED indicators descriptionTo manage the USER LEDs see "LED indicators" on page 42.
9 Product interfacesReliaGATE 10-05-34 User Manual Rev 1-026 / 629.4 Service panel interfacesThe interfaces available behind the service panel are the following:Figure 9.4 - Service panel interfaces layoutRef#Description1Reset pushbutton2Programmable pushbutton3TBD4Console port5Micro SD card slot6Micro SIM card slotTable 9.4 - Service panel interfaces description
ReliaGATE 10-05-34 User Manual Rev 1-010 Interfaces in detail27 / 6210 INTERFACES IN DETAIL10.1 Power supply10.1.1 Power supply parametersPower supplyNominal: 24 V dc; Range: 9 - 36 V dc with Transient, Surge, Noise, ReversePolarity, Overvoltage protectionPower consumption1.5 W idlePeak demand< 15 WThe power input is protected against: surge, noise, reverse polarity, over-voltage and short circuit.The power input is also protected with a resettable fuse.10.1.2 Power supply connector pinoutThe power supply input is available on the 8-position connector located on the front panel, pins 1 and 2.Pin#NameTypeDescription1Power IN +PPositive power supply input2Power IN -PNegative power supply input10.1.3 How to turn ON the ReliaGATE 10-05-34To turn the ReliaGATE 10-05-34 ON, supply power to Pins 1 and 2.The system automatically turns ON and the LED 1(POWER)turns ON.10.1.4 How to turn OFF the ReliaGATE 10-05-34To turn the ReliaGATE 10-05-34 OFF, follow these steps:1. Login the Administration console and run the shutdown command. The system turns OFF2. Remove power from pins 1 and 2.10.1.5 How to manage the ReliaGATE 10-05-34 power consumptionTo reduce the power consumption of your ReliaGATE 10-05-x4: turn OFF the radio interfaces and / or setthe CPU in low power consumption mode (sleep mode).The maximum power consumption at the lowest power state is ≤ 0.4 W.To wake the ReliaGATE 10-05-34 up from the low power consumption mode, use the Console port.
10 Interfaces in detailReliaGATE 10-05-34 User Manual Rev 1-028 / 6210.1.6 How to perform a power reset of the ReliaGATE 10-05-34To trigger a hardware reset of the ReliaGATE 10-05-34, push the reset pushbutton available behind theService Panel.Ref#Description1Reset pushbutton
ReliaGATE 10-05-34 User Manual Rev 1-010 Interfaces in detail29 / 6210.2 Wi-Fi and BluetoothThe ReliaGATE 10-05-34 includes a WLAN + Bluetooth (BT) module and an external antenna connectionto fully implement 802.11b,g,n WiFi and Bluetooth 4.0 functions.10.2.1 Wi-Fi specificationsSpecificationDescriptionStandardIEEE 802.11b, g, n, Wi-Fi compliantFrequency Range2.400 GHz to 2.497 GHz (2.4 GHz ISM Band)Number of Channels2.4GHz:Ch1 to Ch14Modulation802.11b : DQPSK, DBPSK, CCK802.11g, n: OFDM /64-QAM,16-QAM, QPSK, BPSKData Rate802.11b: 1, 2, 5.5, 11 Mbps802.11g: 6, 9, 12, 18, 24, 36, 48, 54 MbpsData Rate(20 MHz, Long GI, 800 ns)802.11n: 6.5, 13, 19.5, 26, 39, 52, 58.5, 65 MbpsData Rate(20 MHz, Short GI, 400 ns)802.11n: 7.2, 14.4, 21.7, 28.9, 43.3, 57.8, 65,72.2MbpsMaximum Input Level802.11b: -10 dBm802.11g, n: -20 dBmAntenna ReferenceSmall antennas with 0 to 2 dBi peak gain10.2.2 Bluetooth specificationsSpecificationDescriptionStandardBluetooth V4.0 of 1, 2 and 3 MbpsHost InterfaceUARTAntenna ReferenceSmall antennas with 0 to 2 dBi peak gainFrequency Band2402 MHz to 2480 MHzNumber of Channels79ModulationFHSS, GFSK, DPSK, DQPSK
10 Interfaces in detailReliaGATE 10-05-34 User Manual Rev 1-030 / 6210.3 CellularThe ReliaGATE 10-05-34 integrates a cellular modem having the following characteristics:SpecificationDescriptionUMTS/HSPA800/850/900/1900/2100 MHz (Bands VI, V, VIII, II, I)3GPP Release 75.76 Mb/s uplink, 21.1 Mb/s downlinkor 5.76 Mb/s uplink, 7.2 Mb/s downlinkGSMGSM 850 / 900 / 1800 / 1900 MHz3GPP Release 7, PBCCH supportGPRSClass 12, CS1-CS4 - up to 86.5 kb/sEDGEClass 12, MCS1-9 - up to 236.8 kb/sCSDGSM max 9.6 kb/sUMTSMax 64 kb/sSMSMT/MO PDU / Text modeProtocolsEmbedded TCP/IP, UDP/IPHTTP/FTP/SSL(Secure Socket Layer)NetworkJamming detection10.4 The MicroSIM card receptacleYour ReliaGATE 10-05-34 includes a push-push type Micro SIM card receptacle.This interface is available behind the Service Panel.NOTICETURN THE SIM PIN OFF!Turn the SIM PIN OFF before inserting the SIM card in the receptacle!The cellular connection will not work if the SIM PIN is ON!Insert the MicroSIM card as in the picture below, with the contacts facing down, and the cut corner facinginwards.
ReliaGATE 10-05-34 User Manual Rev 1-010 Interfaces in detail31 / 6210.5 Ethernet portOn the rear panel, the ReliaGATE 10-05-34 provides one 10/100 Mbps Ethernet port for wired networkconnectivity: ETH0.10.5.1 Connector pinoutPin#NameTypeDescription1TX+OTransmit Data +2TX-OTransmit Data -3RX+IReceive Data +6RX-IReceive Data -10.5.2 Port specificationsFeatureDescriptionNetwork StandardIEEE802.3u 10/100-BaseTX.IEEE 802.3x full-duplex flow control.Speeds10/100-BaseTX interfaces with MACNotesThe interfaces are noise and surge protected.The RJ-45 connector has integrated magnetics.
10 Interfaces in detailReliaGATE 10-05-34 User Manual Rev 1-032 / 6210.6 Host USB portThe ReliaGATE 10-05-34 provides one USB 2.0 host port For power supply only”.This interface is available on the rear panel, and is noise and surge protected.10.6.1 Connector pinoutPin#NameTypeDescription1VBUS5+5V2D-IONegative data3D+IOPositive data4DGNDPDigital ground
ReliaGATE 10-05-34 User Manual Rev 1-010 Interfaces in detail33 / 6210.7 COM ports 0 and 1The ReliaGATE 10-05-34 provides 2 COM ports on the 8-position connector located on the front panel (pins3 to 8):PortTypeProtectionMax baud rateCOM 0RS-485Surge ProtectedUp to 3.6864 MbpsCOM 1RS-232 (3-wire)Surge ProtectedUp to 450 kbps10.7.1 How to insert RS-485 fail-safe and termination resistorsTo insert the RS-485 fail-safe and termination resistors use the DIP switch selector located on the frontpanel, sliding levers 1 to 3.The sliding levers have the following meaning:Lever #Description1ON: 4.7 kΩ pull-up resistor inserted on line RS-485+ (A)OFF: No resistor inserted (default configuration)2ON: 4.7 kΩ pull-down resistor inserted on line RS-485- (B)OFF: No resistor inserted (default configuration)3ON: 120 Ω termination resistor inserted on lines RS485+ / RS485- (A / B)OFF: No resistor inserted (default configuration)
10 Interfaces in detailReliaGATE 10-05-34 User Manual Rev 1-034 / 6210.7.2 COM ports pinoutThe 2 COM ports are available on the 8-position connector located on the front panel, pins 3 to 8.Pin#NameTypeDescription3COM 0: RS-485+ (A)I/OCOM port 0 (RS-485):lA Line4COM 0: RS-485- (B)I/OCOM port 0 (RS-485):lB Line5COM 0: GNDPCOM port 0 (RS-485):lGround6COM 1: TXOCOM port 1 (RS-232):lTransmit Data7COM 1: RXICOM port 1 (RS-232):lReceive Data8COM 1: GNDPCOM port 1 (RS-232):lGround
ReliaGATE10-05-34User Manual Rev 1-010 Interfacesin detail10.8 The MicroSD cardreceptacleThe ReliaGATE 10-05-34 includes a push-push type Micro SD card receptacle behind the Service Panel.Insert the Micro SD card as in the picture below, with the contacts facing down.,._·------------------ -@EUROTECH 35 /62
10 Interfaces in detailReliaGATE 10-05-34 User Manual Rev 1-036 / 6210.9 Console portThe ReliaGATE 10-05-34 provides a Console port behind the Service Panel.It is an RS-232 serial port. You can use it to access the Operating System.10.9.1 Connector and mating connector specificationsConnectorShrouded header, 3-pin, 1.25 mm pitchMating connectorReceptacle Housing, 3-pin, 1.25 mm pitchExample:lManufacturer: MolexlPart number: 51021-030010.9.2 Connector pinoutPin#NameTypeDescription1TXOTransmit Data2RXIReceive Data3DGNDPDigital Ground
ReliaGATE 10-05-34 User Manual Rev 1-010 Interfaces in detail37 / 6210.10 RTC (Real Time Clock)Your ReliaGATE 10-05-34 includes the following two RTC (Real Time Clocks) devices:RTC deviceDescriptionUse/dev/rtc0lIt comes from the CPU SoCReserved/dev/rtc1lIt does not come from the CPU SoClIt is the default RTC used by Linux to set and getthe Wall time while booting up and whilesuspending / resuminglIt has an accuracy of 25 minutes per year (at 25 °C)lIt can trigger an interrupt to the CPU.Wake your ReliaGATE 10-05-x4 up from a deep lowpower state10.10.1 The RTC device "/dev/rtc1"The RTC device "/dev/rtc1" offers:lthree timestamp registerslone user-available byteTo manage the RTC device see the section "RTC" on page 44.
10 Interfaces in detailReliaGATE 10-05-34 User Manual Rev 1-038 / 6210.11 WatchdogYour ReliaGATE 10-05-34 includes a watchdog / supervisor IC, external to the CPU.To manage the watchdog see the section "Watchdog" on page 46.10.11.1 How to enable / disable the watchdogTo enable / disable the watchdog use the DIP switch selector located on the front panel, sliding lever 5.The sliding lever has the following meaning:Lever #Description5ON: Watchdog disabledOFF: Watchdog enabled (default configuration)10.12 The Programmable pushbuttonA programmable pushbutton is available behind the Service Panel.The pushbutton is sensed by a Linux daemon which executes a shell script every time the button is eitherpushed or released.Ref#Description1Programmable pushbutton
ReliaGATE 10-05-34 User Manual Rev 1-011 The Software39 / 6211 THE SOFTWARE11.1 The Linux OS distributionEurotech can provide a Linux operating systems based on Yocto framework (www.yoctoproject.org) aswell as an SDK for application development.All the documentation for the developer is available from: www.yoctoproject.org/documentation.11.2 The bootloader procedureThe bootloader procedure is the following:1. The MLO file is loaded from the on-board eMMC memory, and saved in the on-chip memory toconfigure the RAM memory for use2. The u-boot.img file is loaded, saved in the RAM memory, and executed3. U-Boot executes the Linux kernel from either one of the following sources:lFrom the Ethernet from a server with a defined IP addresslFrom the on-board eMMC4. U-Boot fetches the Linux kernel (/boot/zImage) and the device tree (/boot/reliagate-10-11.dtb), andboots the operating system up11.2.1 How to select the Linux kernel sourcesU-boot can execute the Linux kernel from either one of the following sources:lFrom the Ethernet from a server with a defined IP addresslFrom the on-board eMMCTo select the Linux kernel source use the DIP switch selector located on the front panel, sliding lever 4.The sliding lever has the following meaning:Lever #Description4ON: U-boot executes the Linux kernel from the EthernetOFF: U-boot executes the Linux kernel from the on-board eMMC (default configuration)11.2.2 How to set up a correct eMMC card partitionTo allow the correct bootloader procedure, configure the eMMC memory with at least these 2 partitions:l1st partition:oType: FAT16oFlags: lba, bootoContains the files: MLO and u-boot.imgl2nd partition:oType: ext4oContains the operating system, including the Linux kernel (/boot/zImage) and the device tree(/boot/reliagate-10-11.dtb)
(This page has been intentionally left blank)
ReliaGATE 10-05-34 User Manual Rev 1-012 How to access the interfaces under Linux41 / 62lCOM port 0:/dev/ttyO4 (lCOM port 1:/dev/ttyO3 (lConsole port/dev/ttyO0 (12 HOW TO ACCESS THE INTERFACES UNDER LINUX12.1 Ethernet portOn the rear panel, the ReliaGATE 10-05-x4 exposes one 10/100 Mbps Ethernet port for wired networkconnectivity:lEthernet 0 port, referenced as eth012.2 Wi-Fi and BluetoothOn the rear panel, the ReliaGATE 10-05-x4 exposes an external antenna connection to fully implement Wi-Fi 802.11b/g/n and Bluetooth 4.0 BLE functions:lThe Wi-Fi interface is referenced as wlan0lThe Bluetooth interface is referenced as hci012.3 ModemBy default the ReliaGATE 10-05-x4 exposes the modem as follows:lAT commands port (data communication): /dev/ttyACM0To turn the modem OFF unconditionally, use the following commands:echo1 >/sys/class/gpio/gpio30/valuesleep 0.5echo0 >/sys/class/gpio/gpio30/valueTo toggle the modem power status, use the following commands:echo1 >/sys/class/gpio/gpio60/valuesleep 5echo0 >/sys/class/gpio/gpio60/value12.4 COM ports 0 and 1, Console portThe ReliaGATE 10-05-x4 exposes the COM ports as follows:available on the front panel)available on the front panel)available behind the service panel)12.4.1 How to test a COM portUse the utility below to test the COM port. It works in either RS-232 or RS-485 mode.This utility allows you to transmit/receive data to/from the COM port.NOTE: this utility does not include a local echo (it does not allow you to see the sent data)#connect ttyO3witha baudrateof9600microcom/dev/ttyO3–s9600
12 How to access the interfaces under LinuxReliaGATE 10-05-34 User Manual Rev 1-042 / 6212.5 LED indicatorsThe available LED indicators are the following:Ref#UseColor1POWER:- LED ON: ReliaGATE powered by the external source- LED OFF: ReliaGATE not powered by the external sourceBlue2CELL (Cellular modem activity):- LED ON means modem ON;- LED blinking means modem attached to GSM networkGreen3USER1 (General purpose)Green / Amber4USER2 (General purpose)Green / AmberThey are exposed as follows:lLED 1:ReservedlLED 2:/sys/class/gpio/gpio114/valuelLED 3:/sys/class/gpio/gpio115/valuelLED 4:/sys/class/gpio/gpio116/value12.5.1 How to manage a LEDEach LED is managed by its respective GPIO.Each GPIO needs to be exported before you can use it.The export procedure has to be repeated at each power ON.To drive a LED, complete the following steps:1. Export the LED (if it hasn’t already exported before)2. Drive the LEDTo export LED3, use the following commands:#exportgpio 117echo117 >/sys/class/gpio/export#gpioisoutputechoout>/sys/class/gpio117/directionTo drive LED3, use the following commands:#turnled onecho1 >/sys/class/gpio117/value#turnled offecho0 >/sys/class/gpio117/value
ReliaGATE 10-05-34 User Manual Rev 1-012 How to access the interfaces under Linux43 / 6212.6 Flash MemoryThe ReliaGATE 10-05-x4 exposes the flash memory as follows:lInternal flash (eMMC) memory:/dev/mmcblk0lMicroSD card memory:/dev/mmcblk1
12 How to access the interfaces under LinuxReliaGATE 10-05-34 User Manual Rev 1-044 / 6212.7 RTCThe ReliaGATE 10-05-x4 exposes the user-available RTC as follows:lRTC: /dev/rtc1The "/dev/rtc1" offers:lthree timestamp registerslone user-available byte.12.7.1 How to manage the timestamp registersThe timestamp registers are the following:Timestamp registerWhat it containssys/class/rtc/rtc1/device/timestamp1Reserved datasys/class/rtc/rtc1/device/timestamp2The timestamp that the system last lost power (only if asuccessful initialization has been achieved)sys/class/rtc/rtc1/device/timestamp3The timestamp that the system last has been powered(only if a successful initialization has been achieved)You can only read and reset the timestamp registers.To read the timestamp2, use the following command:cat /sys/class/rtc/rtc1/device/timestamp2To reset the timestamp2, use the following command:echotimestamp2>/sys/class/rtc/rtc1/device/resets12.7.2 How to manage the user-availablebyteThe user-available byte is thefollowing:User-available byteWhat it contains/sys/class/rtc/rtc1/device/ram_byteThe default value is 0.You can write in it a value included in the range: 0 to 255.Thisvalue is retained as long as the /dev/rtc1 device receives avalid power supply (main power supply or battery)You can read and write the user-available byte.To read the byte, use the following command:cat /sys/class/rtc/rtc1/device/ram_byteTo write 112 in the byte, use the following command:echo112 >/sys/class/rtc/rtc1/device/ram_byte
ReliaGATE 10-05-34 User Manual Rev 1-012 How to access the interfaces under Linux45 / 6212.7.3 How to manage the sleep mode (example)To make the ReliaGATE 10-05-34 enter sleep mode, use the following command:echomem>/sys/power/stateThe commands in the example below perform the following actions:1. Sets a specific date and time in the ReliaGATE 10-05-34: 4 September 2015 at 10:00 AM2. Tells the ReliaGATE 10-05-34 to automatically wake up 20 seconds after the specific date and time3. Makes the ReliaGATE 10-05-34 enter sleep mode#setcurrentdateandtimeDATE=”09/04/2015”TIME=”10:00:00”date+”%m/%d/%y%H:%M:%s” –s “$DATE$TIME”#setwakeupdateandtimertctest–d/dev/rtc1–a“04/09/2015 10:00:20”#entersleepmodeechomem>/sys/power/stateTo make the ReliaGATE 10-05-34 exit from sleep mode, use the following procedure:1. Connect the Console port2. Send a character on the Console port
12 How to access the interfaces under LinuxReliaGATE 10-05-34 User Manual Rev 1-046 / 6212.8 WatchdogThe ReliaGATE 10-05-34 exposes the watchdog as follows:lWatchdog: /dev/watchdog112.8.1 How to manage the watchdog using the C programming languageTo manage the watchdog using the C programming language use the following commands:Int interval;Intbootstatus;Longvalue;/* displaycurrentwatchdog value*/If (ioctl(fd,WDIOC_GETTIMEOUT,&interval)==0){// intervalcontainscurrent timeout inseconds}/*Checkiflasdtbootiscausedbywatchdog */If (ioctl(fd,WDIOC_GETBOOTSTATUS,&bootstatus)==0){//bootstatus<> 0Watchdog//bootstatus= 0Power-onreset}/*set thewatchdog value(forexample:30seconds)*/value=30;If (ioctl(fd,WDIOC_SETTIMEOUT,&value)==0){//Watchdoghas beenset to value content}/*stopthewatchdog */write(fd,”V”,1);/*feedthewatchdog */ioctl(fd,WDIOC_KEEPALIVE,0);12.8.2 How to manage the watchdog from the command lineTo set the watchdog value (for example: 30 seconds), use the following command:wdt_setup–d/dev/watchdog1 –t30To start and feed the watchdog, use the following command:echo10 >/dev/watchdog1To stop the watchdog, use the following command:echoV>/dev/watchdog1
ReliaGATE 10-05-34 User Manual Rev 1-012 How to access the interfaces under Linux47 / 6212.8.3 How to obtain further informationTo obtain further information on Linux support for watchdog, see:www.kernel.org/doc/Documentation/watchdog/watchdog-api.txt12.9 The Programmable pushbuttonThe ReliaGATE 10-05-34 is provided with a programmable pushbutton.The programmable pushbutton is sensed by a Linux daemon which executes a shell script every time thebutton is either pushed or released.To export the pushbutton, use the following commands:echo86 >/sys/class/gpio/exportechoin>/sys/class/gpio/gpio86/directionTo see the pushbutton status, use the following commandscat /sys/class/gpio/gpio86/valueThe output will be like the following:lIf the button is being pushed, thenvalueis 1.lIf the button is not being pushed, thenvalueis 0.
(This page has been intentionally left blank)
ReliaGATE 10-05-34 User Manual Rev 1-013 How to log in the Administration Console49 / 6213 HOW TO LOG IN THE ADMINISTRATION CONSOLEYour ReliaGATE 10-05-34 runs a Yocto Linux Operating System.This section describes how to enter the Administration console to access the Operating System for: firstsetup, diagnostic and system maintenance purposes.To login the ReliaGATE 10-05-34 Administration console, use one of the following methods:lDirect login via Console PortlRemote login via Secure Shell (SSH)The default username isrootand the default password iseurotech.Both the username and passwordare case sensitive.13.1 How to login using the Console portTo log in using the Console port, complete the following steps:1. Make sure the ReliaGATE is turned OFF2. Connect a null modem serial cable from your development PC to the Console port on theReliaGATE device3. Start a terminal emulator program (for example TeraTerm) on your development PC (minicom on aLinux host). Configure the serial port connection for 115200, 8 bits, 1 stop bit, no parity, and no flowcontrol4. Connect the power supply to the ReliaGATE. The Power LED lights when power is successfullyconnected5. Via the Uboot bootloader, the Linux kernel is found and launched automatically.6. At the login prompt, enter username and password:lDefault username (case sensitive): rootlDefault password (case sensitive): eurotech13.2 How to login via Secure Shell (SSH)The default (out-of-the-box) network configuration of your ReliaGATE 10-05-x4 is the following:leth0oStatus: Enabled for LANoConfigure: Manually (Static IP)oIP Address: 172.16.0.1oSubnet Mask: 255.255.255.0oDHCP Server Enabledlwlan0oStatus: Disabled13.2.1 How to login if your development PC is running LinuxReliaGATE 10-05-34 eth0 port is configured with the static IP address: 172.16.0.1/24.To log in using eth0, complete the following steps:1. Enter the commandsshroot@172.16.0.12. At the prompt, enter the password:eurotech(case sensitive)13.2.2 How to login if your development PC is running WindowsReliaGATE 10-05-x4 eth0 port is configured with the static IP address: 172.16.0.1/24.To log in using eth0, and complete the following steps:1. Download, install, and run an SSH client (for example PuTTY)
13 How to log in the Administration ConsoleReliaGATE 10-05-34 User Manual Rev 1-050 / 622. Enter the IP address of your ReliaGATE 10-05-34: 172.16.0.1/243. Set the Connection type to ‘SSH’ and Port to ‘22’. Click Open to connect13.3 How to change your security settingsFor security reasons, Eurotech recommends you to change the Linux password after your initial setup.To change your Linux password, complete the followint steps:1. At the login prompt, enter username and password:lDefault username (case sensitive): rootlDefault password (case sensitive): eurotech2. Use the commandpasswdto change the ‘root’ password3. Enter a new ‘root’ account password when prompted
ReliaGATE 10-05-34 User Manual Rev 1-014 Eurotech M2M / IoT solutions51 / 6214 EUROTECH M2M / IOTSOLUTIONSEurotech solutions are a combination of hardware, firmware, operating systems, and programmingframeworks that dramatically accelerate the time to market of M2M / IoT projects and enable customers tolayer their added-value components on a reliable read-to-use infrastructure.14.1 Everyware Software Framework (ESF)The ReliaGATE 10-05-34 comes pre-configured with Eurotech’s Everyware Software Framework (ESF).ESF is a smart application container that enables remote management of IoT gateways and provides awide range of APIs allowing you to write and deploy your own IoT application.ESF runs on top of the Java Virtual Machine (JVM) and leverages OSGi, a dynamic component system forJava, to simplify the process of writing reusable software building blocks. ESF APIs offer easy access tothe underlying hardware including serial ports, GPS, watchdog, USB, GPIOs, I2C, etc. They also offerOSGi bundles to simplify the management of network configurations, the communication with IoT servers,and the remote management of the gateway.ESF is based on Kura, the popular Eclipse open source project, that was originally contributed to theEclipse community by Eurotech.ESF automatically starts at the boot of the ReliaGATE 10-05-x4.14.2 The ESF Web UIESF provides a web-based user interface - "ESF Web UI" - that allows you to:lMonitor the gateway statuslManage the network configurationlOversee the installed application(s) and services.The ESF Web UI is available on port 80 of the gateway IP.The following picture gives you an example of the “ESF Web UI”:
14 Eurotech M2M / IoT solutionsReliaGATE 10-05-34 User Manual Rev 1-052 / 6214.3 Everyware Cloud (EC)Eurotech’s Everyware™ Cloud (EC) provides an open and flexible software platform that easily connectsembedded devices to IT systems or to existing applications, immediately solving infrastructure problemsamong distributed devices and systems.With EC you can:lConnect any sensor, device or asset to the platform to quickly create new productslDynamically and remotely create and add new services and functionalities to your field deviceslConfigure the platform to analyze data in real-time and trigger immediate alertslLeverage a device-specific message-oriented infrastructure for fast and easy creation of reliable,device-independent M2M/IoT applicationslIntegrate MVNO Connectivity Platforms to have a single point of management of ConnectedDevices and associated SIM cardslEnable IoT Analytics through built-in connectors to on-line Dashboards and Analytical ReportslEnable IoT Business Application Integrations through native REST APIs14.4 For further informationFor further information about ESF and EC, and to find exhaustive tutorials, refer to the following links:InformationAvailable atESF Guideesf.eurotech.com/docs/Kura websiteeclipse.org/kura/EC Developer’sGuideeverywarecloud.eurotech.com/doc/ECDevGuide/EC M2M IntegrationPlatformeurotech.com/en/products/software+services/everyware+cloud+m2m+platform
ReliaGATE 10-05-34 User Manual Rev 1-015 Mechanical specifications53 / 6215 MECHANICAL SPECIFICATIONS15.1 ReliaGATE 10-05-34 mechanical dimensionsThe ReliaGATE 10-05-34 electronics are housed in an ABS (Color: blue) and Aluminum enclosure, havingthe following dimensions: 112 (L) x 68 (W) x 37 (H); mm (antenna SMA connectors not included).The following figure shows the dimensions of the ReliaGATE 10-05-34. All dimensions are in millimeters.Figure 15.1 - ReliaGATE 10-05-34: mechanicaldimensions
15 Mechanical specificationsReliaGATE 10-05-34 User Manual Rev 1-054 / 6215.2 Mounting bracket mechanical dimensionsThe following figure shows the dimensions of the Mounting bracket. All dimensions are in millimeters.Figure 15.2 - Mounting bracket mechanical dimensions
ReliaGATE 10-05-34 User Manual Rev 1-016 How to install the product55 / 6216 HOW TO INSTALL THE PRODUCTTo install the ReliaGATE 10-05-34 in place you can use the provided Mounting Bracket.Optionally, you can use the DIN Rail Mounting Kit to install the ReliaGATE 10-05-x4 on a DIN rail.16.1 How to install the ReliaGATE 10-05-34 using the MountingBracketTo install the ReliaGATE 10-05-34 in place using the Mounting Bracket, add all the necessary screws andlocking parts to safely secure the ReliaGATE 10-05-34 in place according to your installation requirements(for example use M5 screws).For further information see "Mounting bracket mechanical dimensions" on page 54.
16 How to install the product56 / 62ReliaGATE 10-05-34 User Manual Rev 1-016.2 Optional: How to install the ReliaGATE 10-05-34 using theDIN Rail Mounting KitUse the optional DIN Rail Mounting Kit to install the ReliaGATE 10-05-34 on a DIN rail.Before installing the ReliaGATE 10-05-34 on a DIN rail, replace the Mounting Bracket with the optionalDIN Rail Mounting Kit.16.2.1 How to replace the Mounting Bracket with the DIN Rail Mounting KitTo replace the Mounting Bracket with the DIN Rail Mounting Kit, complete the following steps:1. Remove the 3 screws that hold the Mounting Bracket in place2. Remove the Mounting Bracket3. Place the DIN Rail Mounting Kit4. Fasten the 3 screws removed at Step 1 to hold the DIN Rail Mounting Kit in place
ReliaGATE 10-05-34 User Manual Rev 1-016 How to install the product57 / 62NOTE ABOUT THE 3 SCREWS:The 3 screws that hold the Mounting Bracket in place have the following features:lCross socket flat head countersunklFully threadedlStainless steel
16 How to install the product58 / 62ReliaGATE 10-05-34 User Manual Rev 1-016.2.2 How to install the ReliaGATE 10-05-34 on a DIN railPrerequisite: Replace the Mounting Bracket with the DIN Rail Mounting KitTo install the ReliaGATE 10-05-34 on a horizontal DIN rail, complete the following steps:1. Hook the lower mobile latches of the mechanical adapter on the lower edge of the DIN rail2. Push the ReliaGATE 10-05-34 upwards against the DIN rail and lock upper latches of themechanical adapter on the upper edge of the DIN rail.16.2.3 How to remove the ReliaGATE 10-05-34 from a DIN railTo remove the ReliaGATE 10-05-34 from a horizontal DIN rail, complete the following steps:1. Push the lower mobile latches of the mechanical adapter upwards to release the upper latches2. Pull the ReliaGATE 10-05-34 out
59 / 62ReliaGATE 10-05-34 User Manual Rev 1-017 How to maintain the product17 HOW TO MAINTAIN THE PRODUCTPeriodically inspect the installation of the product to verify its integrity and to ensure proper operation.Before starting the maintenance of the product, carefully read and understand the instructionscontained in the sections "Important Information" on page 1 and "Safety Instructions" on page 1.17.1 Use antistatic precautionsNOTICEPREVENTING ELECTROSTATIC DISCHARGE (ESD)When handing the product described in this document, always use appropriateantistatic precautions to avoid damages due to electrostatic discharge.For example: use a wrist strap or ESD cuff kept in constant contact with bare skinand attached to an ESD ground.17.2 Remove the power supplyWARNINGELECTRIC SHOCK HAZARDTo avoid injuries do not perform any cables connection/disconnection with wet handsBefore starting the maintenance of the product, complete the following steps:1. Remove the power supply2. Disconnect all the cables3. Make sure all the circuits are discharged.Failure to complete the steps above, may create an electric shock hazard, which could result inpersonal injury or loss of life, and / or damage to equipment or other property17.3 Inspect the installation of the productTo inspect the installation of the product, complete the following steps:1. Verify that the external surface of the product is clean and not damaged2. Verify that the LED indicators are not damaged, clean and visible3. Verify that all the screws, bolts, nuts, etc. are correctly fastened.17.4 Clean the productTo clean the product, complete the following steps:1. Use a dry cloth to remove dust and fingerprints from the external casing2. Do not use detergents, aerosol sprays, solvents or abrasive sponges3. Use water-based, non-flammable, cleaner products to remove all types of dirt (example: grease, oil,nicotine etc.)4. Wipe the chassis with a lint-free cloth
(This page has been intentionally left blank)
ReliaGATE 10.05-34 User Manual Rev1-0NotesNOTES@EUROTECH 61/62
WORLD SUPPORT EUROPE AMERICAS ASIAHEADQUARTERSEUROTECHVia Fratelli Solari, 3/a33020 Amaro (UD) - ItalyTel: +39 0433.485.411Fax: +39 0433.485.499Email: support.it@eurotech.comWeb: www.eurotech.comITALYEUROTECHTel: +39 0433.485.411Fax: +39 0433.485.499Email: sales.it@eurotech.comEmail: support.it@eurotech.comWeb: www.eurotech.comUNITED KINGDOMEUROTECHTel: +44 (0) 1223.403410Fax: +44 (0) 1223.410457Email: sales.uk@eurotech.comEmail: support.uk@eurotech.comWeb: www.eurotech.comFRANCEEUROTECHTel: +33 (0)4.72.89.00.90Fax: +33 (0)4.78.70.08.24Email: sales.fr@eurotech.comEmail: support.f r@eurotech.comWeb: www.eurotech.comUSAEUROTECHTel: +1 800.541.2003Tel: +1 301.490.4007Fax: +1 301.490.4582Email: sales.us@eurotech.comEmail: support.us@eurotech.comWeb: www.eurotech-inc.comJAPANADVANETTel: +81 86.245.2861Fax: +81 86.245.2860Email: sales@advanet.jpEmail: tsupport@advanet.jpWeb: www.advanet.jpFor your Eurotech local contact refer to:www.eurotech.com/contactsFor the Eurotech Global Support Center refer to:eurotech.desk.comFor the Eurotech Download Area refer to:eurotech.com/downloadAll trademarks and trade names are the property of their respective owners