Eaton s Cooper Power Systems 500LG RFN-500LG Module User Manual EkaNet Mobile Collection Software

Eaton's Cooper Power Systems RFN-500LG Module EkaNet Mobile Collection Software

User Manual

Download: Eaton s Cooper Power Systems 500LG RFN-500LG Module User Manual EkaNet Mobile Collection Software
Mirror Download [FCC.gov]Eaton s Cooper Power Systems 500LG RFN-500LG Module User Manual EkaNet Mobile Collection Software
Document ID3192387
Application IDFpiKf3ryEMHrSrA3o+uaIA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize24.08kB (300958 bits)
Date Submitted2016-11-10 00:00:00
Date Available2016-11-14 00:00:00
Creation Date2017-12-17 14:19:28
Producing SoftwareGPL Ghostscript 9.18
Document Lastmod2017-12-17 14:19:28
Document TitleEkaNet Mobile Collection Software
Document CreatorMicrosoft® Word 2010
Document Author: Bill Creitz

RFN-500LG User’s Guide
Document Number
XXXX
Revision 1
Eaton’s Cooper Power Systems
910 Clopper Road, Suite 201S
Gaithersburg, MD 20878 USA
www.eaton.com
Tel (301) 515-7118
Fax: (301) 515-4965
Contents
1 About the RFN500LG ............................................................................................................................. 3
2 Regulatory Notices................................................................................................................................. 4
3 RFN500LG Specifications ..................................................................................................................... 7
XXXXX-01
RFN-500LG User’s Guide
1 About the RFN-500LG
The RFN-500LG is a radio communications device designed for use in L+G Focus
meters. It can also be used in Eaton’s Cooper Power Systems Gateways and Relay
Nodes. The RFN-500LG provides a 915 MHz radio interface to an RF mesh network.
The RFN-500LG operates from a power source of 120 VAC to 277 VAC, received from
the host device. It may also be powered from a 12VDC power source. The supplied
voltage is then regulated to 5.0 VDC and 3.3VDC by the on-board power supply circuit.
The radio modules operate in license-free bands at 915 MHz (902.75 to 927.25 MHz).
RFN-500LG Nodes are fully compatible with mesh network hardware, protocols and
operations. Five radio transmission data rates are available: 9.6 kb/s, 19.2 kb/s, 38.4
kb/s, 76.8 kb/s and 153.6 kb/s. The transmission power of the 915 MHz radio is
adjustable from 30 dBm to -20 dBm.
XXXXX-01
RFN500LG User’s Guide
2 Regulatory Notices
Warning
The Original Equipment Manufacturer (OEM) must ensure that FCC
Labeling requirements are met. This includes a clearly visible label on the
outside of the OEM enclosure specifying the Cooper Power Systems FCC
identifier (FCC ID: P9X-500LG) and IC Number (IC: 6766A-500LG) as well
as the FCC Notice below.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
Warning
Warning
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that
may cause undesired operation.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables
aux appareils radio exempts de licence. L'exploitation est autorisée aux
deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi,
même si le brouillage est susceptible d'en compromettre le fonctionnement.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Warning
Warning
XXXXX-01
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
 Reorient or relocate the receiving antenna.
 Increase the separation between the equipment and receiver.
 Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
 Consult the dealer or an experienced radio/TV technician for help.
RFN-500LG User’s Guide
Warning
Warning
The installer of this radio equipment must ensure that the antenna is located
or pointed such that it does not emit RF field in excess of Health Canada
limits for the general population; consult Safety Code 6, obtainable from
Health Canada’s website www.hc-sc.gc.ca/rpb.
To comply with FCC RF exposure compliance requirements, the antenna
used for this transmitter must be installed to provide a separation distance of
at least 20 cm from all persons and must not be co-located or operate in
conjunction with any other antenna or transmitter.”
As such, the radio component of this device is intended only for OEM
integrators under the following two conditions:
The antenna must be installed such that 20 cm is maintained between the
antenna and users.
The transmitter module may not be co-located with any other transmitter or
antenna.
As long as the two conditions above are met, further transmitter testing will
not be required. However, the OEM integrator is still responsible for testing
their end product for any additional compliance requirements required with
this module installed (e.g., digital device emissions, PC peripheral
requirements).
In the event that these conditions cannot be met (for example, co-location
with another transmitter), then the FCC authorization is no longer considered
valid and the FCC ID cannot be used on the final product. In these
circumstances, the OEM integrator will be responsible for re-evaluating the
end product (including the transmitter) and obtaining a separate FCC
authorization.
End Product Labeling
This transmitter module is authorized only for use in devices where the
antenna may be installed such that 20 cm may be maintained between the
antenna and users (for example access points, routers, wireless ASDL
modems, certain laptop configurations, and similar equipment). The final
end product must be labeled in a visible area with the following:
“Contains FCC ID: P9X-500LG, IC: 6766A-500LG”.
The radio component is an integral part of the RFN-500LG and cannot
be removed.
XXXXX-01
RFN-500LG User’s Guide
Transmitters with Detachable Antennas
This device has been designed to operate with the antennas listed below,
and having a maximum gain of 5 dB. Antennas not included in this list or
having a gain greater than 5 dB are strictly prohibited for use with this
device. The required antenna impedance is 50 ohms.
Antennas that may be used with this product include:
Warning




Linx ¼ Wave Through-hole Helical, 2.4dBi
Omnidirectional Molex P-N 1052620003, 1.2dBi
Laird OD9-5-ANT 900MHz Omnidirectional - 5 dBi
Laird B(B)8965CN 5/8 Wave Loaded Coil 900MHz Omnidirectional
Antenna, 5dBi
To reduce potential radio interference to other users, the antenna type and
its gain should be so chosen that the equivalent isotropically radiated power
(e.i.r.p.) is not more than that permitted for successful communication.
XXXXX-01
RFN-500LG User’s Guide
3 RFN500LG Specifications
Radio Specifications
Operating frequency
902.75 – 927.25 MHz
Reliable data transmission
Error detection, correction and retransmission
RF output power
30 dBm (maximum) to -20 dBm
Data rate
9.6 kb/s, 19.2 kb/s, 38.4 kb/s, 76.8 kb/s, 153.6 kb/s
Receiver sensitivity
-114 dBm (@ 1.0% PER, 9.6 kb/s, +25° C
Range (w/ omni antenna)
Outdoor 1,000 m (3200 ft)
Indoor 75 – 150 m (225 – 490 ft)
Mode
Frequency Hopping Spread Spectrum (FHSS)
Mechanical Specifications
Weight
Unavailable
Dimensions
100 mm x 120 mm
Operating Conditions
XXXXX-01
Environmental
-40° C to +85° C
0 – 95% non-condensing humidity
Power supply
AC 120-277V, DC 12V (regulated to 5.0 VDC and 3.3 VDC onboard)
Power consumption
< 6W
RFN-500LG User’s Guide
Eaton’s Cooper Power Systems
910 Clopper Raod, Suite 201S
Gaithersburg, MD 20878 USA
www.eaton.com
Tel (301) 515-7118
Fax: (301) 515-4965

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 1
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:389838f6-a763-11f2-0000-02c7314339d4
Producer                        : GPL Ghostscript 9.18
Modify Date                     : 2017:07:23 01:31:38Z
Create Date                     : 2017:07:23 01:31:38Z
Creator Tool                    : UnknownApplication
Document ID                     : uuid:389838f6-a763-11f2-0000-02c7314339d4
Format                          : application/pdf
Title                           : Untitled
EXIF Metadata provided by EXIF.tools
FCC ID Filing: P9X-500LG

Navigation menu