Eaton s Cooper Power Systems 900SIP 900SiP Radio Module User Manual EkaNet Mobile Collection Software

Eaton's Cooper Power Systems 900SiP Radio Module EkaNet Mobile Collection Software

Users Manual

Download: Eaton s Cooper Power Systems 900SIP 900SiP Radio Module User Manual EkaNet Mobile Collection Software
Mirror Download [FCC.gov]Eaton s Cooper Power Systems 900SIP 900SiP Radio Module User Manual EkaNet Mobile Collection Software
Document ID1291487
Application ID4Czu7HYDmY5PrxXlK41SuA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize7.54kB (94309 bits)
Date Submitted2010-06-07 00:00:00
Date Available2010-06-17 00:00:00
Creation Date2010-06-01 13:16:47
Producing SoftwareAdobe PDF Library 8.0
Document Lastmod2010-06-01 13:16:49
Document TitleEkaNet Mobile Collection Software
Document CreatorAcrobat PDFMaker 8.1 for Word
Document Author: Bill Creitz

Eka 900SiP User’s Guide
Document Number
XXXX
Revision 1
Eka Systems, Inc.
20201 Century Boulevard, Suite 250
Germantown, MD 20874 USA
www.ekasystems.com
Tel (301) 515-7118
Fax: (301) 515-4965
Contents
1 About the Eka 900SiP Radio Module.................................................................................................... 3
2 Regulatory Notices................................................................................................................................. 4
3 Eka 900SiP Radio Module Specifications ............................................................................................ 6
XXXXX-01
Eka 900SiP User’s Guide
1 About the Eka 900SiP Radio Module
The Eka 900SiP radio module is designed for use in Eka’s 915 MHz wireless products. it
provides a 915 MHz radio interface for communicating on an EkaNet network.
The 900SiP radio module operates from a power source of 2.5V to 3.6V, received from
the host device. The radio module operate in the 915 MHz license-free band. Eka 900SiP
Nodes are fully compatible with EkaNet mesh network hardware, protocols and
operations. Two radio transmission data rates are available: 76.8 kb/s an d153.6 kb/s.
Transmission power is adjustable from 27 dBm to -20 dBm.
XXXXX-01
Eka 900SiP Node User’s Guide
2 Regulatory Notices
Warning
The Original Equipment Manufacturer (OEM) must ensure that FCC
Labeling requirements are met. This includes a clearly visible label on the
outside of the OEM enclosure specifying the Eka Systems FCC identifier
(FCC ID: P9X-900SIP) and IC Identifier (IC: 6766A-900SIP) as well as the
FCC Notice below.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions:
Warning
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that
may cause undesired operation.
Changes or modifications not expressly approved by the party responsible
for compliance could void the user’s authority to operate the equipment.
Warning
Warning
Warning
XXXXX-01
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate
radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the
following measures:
 Reorient or relocate the receiving antenna.
 Increase the separation between the equipment and receiver.
 Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
 Consult the dealer or an experienced radio/TV technician for help.
The installer of this radio equipment must ensure that the antenna is located
or pointed such that it does not emit RF field in excess of Health Canada
limits for the general population; consult Safety Code 6, obtainable from
Health Canada’s website www.hc-sc.gc.ca.
Eka 900SiP User’s Guide
Warning
To comply with FCC RF exposure compliance requirements, the antenna
used for this transmitter must be installed to provide a separation distance of
at least 22.4 cm from all persons and must not be co-located or operate in
conjunction with any other antenna or transmitter.”
As such, the radio component of this device is intended only for OEM
integrators under the following two conditions:
The antenna must be installed such that 22.4 cm is maintained between the
antenna and users.
The transmitter module may not be co-located with any other transmitter or
antenna.
As long as the two conditions above are met, further transmitter testing will
not be required. However, the OEM integrator is still responsible for testing
their end product for any additional compliance requirements required with
this module installed (e.g., digital device emissions, PC peripheral
requirements).
In the event that these conditions cannot be met (for example, co-location
with another transmitter), then the FCC authorization is no longer considered
valid and the FCC ID cannot be used on the final product. In these
circumstances, the OEM integrator will be responsible for re-evaluating the
end product (including the transmitter) and obtaining a separate FCC
authorization.
End Product Labeling
This transmitter module is authorized only for use in devices where the
antenna may be installed such that 22.4 cm may be maintained between the
antenna and users (for example access points, routers, wireless ASDL
modems, certain laptop configurations, and similar equipment). The final
end product must be labeled in a visible area with the following: “FCC
ID: P9X-900SIP”.
The radio component is an integral part of the Eka module and cannot
be removed.
XXXXX-01
Eka 900SiP User’s Guide
3 Eka 900SiP Radio Module Specifications
Radio Specifications
Operating frequency
902 – 928 MHz
Reliable data transmission
Error detection, correction and retransmission
RF output power
27 dBm to -20 dBm
Data rate
76.8 kb/s, 153.6 kb/s
Receiver sensitivity
-98 dBm (@ 0.1% BER, +25° C
Range (w/ omni antenna)
Outdoor < 1,000 m (3200 ft)
Indoor 75 – 150 m (225 – 490 ft)
Mode
Frequency hopping spread spectrum
Mechanical Specifications
Weight
unavailable
Dimensions
27mm x 27mm x 3.5mm
Operating Conditions
XXXXX-01
Environmental
-40° C to +85° C
0 – 95% non-condensing humidity
Power supply
2.5V to 3.6V
Power consumption
< 1W
Eka 900SiP User’s Guide
20201 Century Boulevard, Suite 250
Germantown, MD 20874 USA
www.ekasystems.com
Tel (301) 515-7118
Fax: (301) 515-4965

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:14:39
Modify Date                     : 2010:06:01 13:16:49-04:00
Create Date                     : 2010:06:01 13:16:47-04:00
Metadata Date                   : 2010:06:01 13:16:49-04:00
Document ID                     : uuid:120c6594-0bd6-4a08-a329-764e94c094eb
Instance ID                     : uuid:6774073c-9313-462f-8698-f33b269bb663
Format                          : application/pdf
Title                           : EkaNet Mobile Collection Software
Creator                         : Bill Creitz
Producer                        : Adobe PDF Library 8.0
Company                         : Eka Systems, Inc.
Page Count                      : 7
Page Layout                     : OneColumn
Author                          : Bill Creitz
EXIF Metadata provided by EXIF.tools
FCC ID Filing: P9X-900SIP

Navigation menu