Ecolab 92053026 Hand hygiene compliance monitoring system Nexa Touchfree Beacon (Classic or compact) User Manual 72131442 Manual Coverx

Ecolab Inc. Hand hygiene compliance monitoring system Nexa Touchfree Beacon (Classic or compact) 72131442 Manual Coverx

Manual

Download: Ecolab 92053026 Hand hygiene compliance monitoring system Nexa Touchfree Beacon (Classic or compact) User Manual 72131442   Manual Coverx
Mirror Download [FCC.gov]Ecolab 92053026 Hand hygiene compliance monitoring system Nexa Touchfree Beacon (Classic or compact) User Manual 72131442   Manual Coverx
Document ID3670651
Application IDHy1EapuXhKhorn/X3CT8xA==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize50.48kB (630976 bits)
Date Submitted2017-12-11 00:00:00
Date Available2017-12-11 00:00:00
Creation Date2017-12-05 09:22:17
Producing SoftwareNuance PDF Create
Document Lastmod2017-12-05 09:23:03
Document TitleMicrosoft Word - 72131442 - Manual Cover.docx
Document CreatorMicrosoft Word - 72131442 - Manual Cover.docx
Document Author: geris-je

Certification Exhibit
FCC ID: Z9O-92053026
IC: 10060A-92053026
FCC Rule Parts: 15.209, 15.249, 15.231
ISED Canada’s Radio Standards Specification: RSS-210
TÜV SÜD Project Number: 72131442
Manufacturer: Ecolab, Inc.
Model: 92053026
Manual
3998 FAU Blvd., Suite 310, Boca Raton, FL 33431, Phone: 561-961-5585
Ecolab Hand Hygiene
Compliance Monitoring System™
NEXA HHCM Touch Free Dispenser Beacon (Compact) User’s Guide
9205-3026
© 2017 Ecolab USA Inc. All rights reserved. Rev. 0617
9205-3026 NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) USER’S GUIDE
Table of Contents
Abstract........................................................................................................................................................................................ 3
Revision History ........................................................................................................................................................................... 3
Reference Documents ................................................................................................................................................................. 3
Terms, Acronyms and Abbreviations ........................................................................................................................................... 3
1. NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) Overview ................................................................................. 2
2. NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) Set Up ...................................................................................... 2
2.1 Installing Batteries ............................................................................................................................................................ 2
2.2 Installing the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) in a Nexa™ Touch Free Dispenser ............... 3
2.3 Adjusting Communication Range...................................................................................................................................... 4
2.4 Removal of the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) from a Nexa™ Touch Free Dispenser ....... 5
3. How the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) Works ........................................................................ 5
3.1 Interaction with a Healthcare Worker’s Badge ................................................................................................................ 5
3.2 Interaction with a Hub ...................................................................................................................................................... 6
4. NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) Status Information .................................................................. 6
4.1 Yellow LED – Successful Communication Between HCW Badge and Dispenser Beacon. ................................................. 6
4.2 When an Empty Product Bottle is Removed and a New Bottle is Installed ...................................................................... 6
5. NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) Care and Maintenance ............................................................ 6
5.1 Handling ............................................................................................................................................................................ 6
5.2 Cleaning ............................................................................................................................................................................ 7
5.3 Battery Replacement ........................................................................................................................................................ 7
Appendix A - Certification and Safety Approvals ......................................................................................................................... 8
Figures
Figure 1. Battery door location .................................................................................................................................................... 2
Figure 2. NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) Installation into Nexa™ Touch Free Dispenser .............. 3
Figure 3. Installation Tool screen ................................................................................................................................................. 4
Figure 4. FCC & IC Label Information ........................................................................................................................................... 9
Ecolab P/N
9205-3026
Page
2 of 11
9205-3026 NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) USER’S GUIDE
Abstract
This document describes basic setup, function, use and maintenance of the 92053026 NEXA HHCM TOUCH FREE DISPENSER
BEACON (COMPACT).
Revision History
Revision
Date
By
Description
10/10/17
AP
Initial Release
Reference Documents
Badge States Handout
Badge User Manual
World Health Organization “Your 5 Moments for Hand Hygiene”,
http://www.who.int/gpsc/5may/background/5moments/en
Ecolab Beacon Installation Tool Users Guide
Terms, Acronyms and Abbreviations
Factory Default
HCW
LED
Patient Contact
Patient Zone
Ecolab HH CMS
WHO
Ecolab P/N
9205-3026
A setting or parameter that is programmed with an initial default value by the manufacturer but that
may be modified by the healthcare facility.
Healthcare Worker
Light Emitting Diode
Having physical contact with a patient, their immediate surroundings or being in close proximity to an
Ecolab Hand Hygiene Compliance Monitoring System equipped patient bed.
The area around a patient bed that is detectable by an Ecolab HH CMS HCW Badge. Being inside the
patient zone will be considered patient contact.
Ecolab Hand Hygiene Compliance Monitoring System
World Health Organization
Page
3 of 11
9205-3026 NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) USER’S GUIDE
1. NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) Overview
The NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) (part number 9205-3026) is an integral component of the
Ecolab HH CMS. When the Ecolab HH CMS is installed, Healthcare facilities determine which dispensers they wish to have
monitored, and a NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) is installed in those dispensers. Each NEXA
HHCM TOUCH FREE DISPENSER BEACON (COMPACT) has a unique identification address that is associated to a specific
physical location during the installation process.
The NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) communicates with Healthcare Worker Badges to obtain
Badge ID and hand hygiene status information during a dispense event. The dispense event communication sets the HCW
Badge’s hand hygiene status to “Green” or “State 0” and then both the dispenser and the HCW badge ID information is
transmitted by the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) to the nearest Hub, along with the time and
date of the event, to be relayed to the offsite server for data compilation. Once the information exchange between the
NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) and the HCW Badge is complete, the dispenser LED will light up
Yellow to indicate that the HCW has been credited with the dispense event.
2. NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) Set Up
2.1
Installing Batteries
Each NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) requires 2 AA alkaline batteries for operation. These
must be installed prior to initial installation of the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) in the
dispenser. The battery compartment door for the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) can be
found on the top side of the device.
To install batteries prior to initial installation into the HH dispenser, complete the following steps:
1.
Remove the battery compartment door by gently unscrewing the battery door and lifting it away from the
body of the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT).
2.
Once the battery compartment door has been removed, install two (2) AA alkaline batteries, aligning the
positive (+) and negative (-) terminals of the batteries with the corresponding signs displayed within the
battery compartment (Ecolab recommends that only Duracell® Coppertop batteries be used).
3.
Once the batteries have been installed, replace the battery compartment door, firmly tighten the door screw,
and make sure the battery compartment door is flush with the body of the beacon before installation in the
dispenser.
Battery
Compartment
Door
FCC Label
ID Label
Figure 1. Battery door location
Ecolab P/N
9205-3026
Page
2 of 11
9205-3026 NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) USER’S GUIDE
2.2
Installing the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) in a Nexa™ Touch Free
Dispenser
The NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) can be used in the large (“Classic”) and small
(“Compact”) version of the Nexa Touch Free Dispenser.
To install the dispenser beacon:
(1) Open the dispenser by depressing the top latch button.
(2) Remove product bottle (if any) from the dispenser and set aside.
(3) Remove the rubber communication port cover in the back of the dispenser (see figure 2) and discard.
(4) Align the plug with the communication port and the housing’s captive screw with the screw boss in the
back of the dispenser (see figure 2).
(5) Gently but firmly insert the plug (adjusting the plug may be necessary) into the communication port, until
it is firmly seated in the port.
(6) Tighten the captive screw finger tight into the boss.
(7) Replace the product bottle within the dispenser.
(8) Close the dispenser.
Plug
Screw
Boss
Communication
Port Cover
Installation: alignment of
TF CMPCT BCN with
dispenser boss and
communication port
Figure 2. NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) Installation into Nexa™ Touch Free Dispenser
Ecolab P/N
9205-3026
Page
3 of 11
9205-3026 NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) USER’S GUIDE
2.3
Adjusting Communication Range
The Beacon Installation Tool is used to adjust the communication range on the NEXA HHCM TOUCH FREE DISPENSER
BEACON (COMPACT).
To adjust the communication range:
1. With the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) installed in the dispenser, hold the
Installation Tool within 10 inches of the dispenser and select mode “Range Adjust” (Refer to Ecolab Beacon
Installation Tool Users Guide). Activate the dispenser (i.e., dispense product) to establish communication
between the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) and the Installation Tool. Note: both
yellow and red LED on the Installation Tool will flash when it has successfully communicated with the NEXA
HHCM TOUCH FREE DISPENSER BEACON (COMPACT). The NEXA HHCM TOUCH FREE DISPENSER BEACON
(COMPACT) address (device ID number) and its current range setting should be displayed on the Installation
Tool screen (See Figure 3).
2. To adjust the communication range, press the UP
(increase) or Down (decrease)
key on the Installation
Tool until the desired range setting is displayed, then press the “Select” button. An audible confirmation from
the Installation Tool should be heard. Activate the dispenser to complete the update to the range setting on
NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT). Note: The LED on the dispenser will flash two (2)
times when the range setting has successfully updated.
Address
Range settings
Mode Setting
Figure 3. Installation Tool screen
Ecolab P/N
9205-3026
Page
4 of 11
9205-3026 NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) USER’S GUIDE
2.4
Removal of the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) from a Nexa™ Touch
Free Dispenser
To remove the dispenser beacon:
(1) Open the dispenser by depressing the top latch button.
(2) Remove product bottle (if any) from the dispenser and set aside
(3) Unscrew the captive screw from the boss, to release the beacon and allow it to be removed.
(4) Gently grasp and pull on the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) to disengage the
plug from the communication port.
3. How the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) Works
The NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) is a wireless device that detects and communicates with
Ecolab HH CMS HCW badges and Hubs. The NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) communicates with
a HCW badge based on its proximity to the device. When the HCW dispenses soap or sanitizer by placing their hand under
the dispenser, a proximity bubble is created around the dispenser. The proximity bubble wakes up the HCW Badge and
begins the information exchange between the devices. The dispenser then communicates time, date, badge status and ID
information (the dispenser ID and badge ID) to a Hub, which relays it on to the remote server.
3.1
Interaction with a Healthcare Worker’s Badge
When the touch free dispenser dispenses product, the attached Encompass HH CMS the NEXA HHCM TOUCH FREE
DISPENSER BEACON (COMPACT) will momentarily create a proximity bubble around itself and the dispenser. If the
Badge worn by the HCW activating the dispenser is within the proximity bubble, the Badge will communicate with the
NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) and then will change to the proper hand hygiene status level.
If the Badge is not within the proximity bubble, it will not communicate with the NEXA HHCM TOUCH FREE DISPENSER
BEACON (COMPACT) nor will its hand hygiene status level change. This will result in the HCW not receiving credit for
using the dispenser.
The default range of the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT)’s proximity bubble is about 24
inches in all directions but the range can be adjusted if necessary. It is important for the HCW to wear their Badge in a
location that insures it is within the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT)’S proximity bubble
whenever a dispenser is activated. It is also important that only one Badge is within the proximity bubble when a
dispenser is activated. If more than one Badge is within the proximity bubble, the NEXA HHCM TOUCH FREE DISPENSER
BEACON (COMPACT) may unintentionally communicate with the wrong Badge (i.e., a Badge belonging to a HCW that did
not activate the dispenser). If this happens, the wrong Badge will change its hand hygiene status level and the wrong
HCW will receive credit for using the dispenser.
The Nexa Touch Free dispenser is equipped with a user feedback LED (gold light). This LED is in the same spot as the
battery indicator light, but is a different color (yellow/gold). The feedback LED will only flash when the NEXA HHCM
TOUCH FREE DISPENSER BEACON (COMPACT) has successfully communicated with a Badge. The LED flash will occur
during or immediately after dispenser activation. If the LED does not flash, the Badge may not have been within the
proximity bubble or there was an error in communications. If this occurs, the HCW should move closer to the dispenser
and activate it again.
Please take the following steps to insure proper Badge communications and correct HCW credit when using a dispenser.
1.
Verify that the Badge is being worn in a location that will be within a NEXA HHCM TOUCH FREE DISPENSER
BEACON (COMPACT)’s 24-inch proximity bubble.
2.
Before activating a dispenser, verify that other HCWs are not within the NEXA HHCM TOUCH FREE DISPENSER
BEACON (COMPACT)’S 24-inch proximity bubble. If there are other HCWs near the dispenser, kindly ask them
to move away before activating.
Ecolab P/N
9205-3026
Page
5 of 11
9205-3026 NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) USER’S GUIDE
3.
3.2
Verify that the dispenser’s yellow LED flashed when the dispenser was activated. If the LED did not flash, move
closer to the dispenser and activate it again.
Interaction with a Hub
All NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT)’s are equipped with a longer-range radio that allows
them to transmit information to the Ecolab HH CMS Hubs. The NEXA HHCM TOUCH FREE DISPENSER BEACON
(COMPACT) will transmit to the Hub that is closest to it or from which it gets the strongest signal. At time of system
install, it is verified that all NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT)S are in range of at least one Hub.
When the Nexa touch free dispenser dispenses product, the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT)
is activated, will create a proximity bubble and search for HCW badges. If the user is wearing a badge, the Badge’s HH
status will be updated by the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT). The NEXA HHCM TOUCH FREE
DISPENSER BEACON (COMPACT) will then transmit the Badge’s HH status (both just prior to and immediately after the
dispense) to the Hub. The NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) will also transmit the time, date
and location of the event, along with the battery status of the HCW badge and the NEXA HHCM TOUCH FREE DISPENSER
BEACON (COMPACT). If the user is not wearing a badge, or is not within the proximity bubble, the time, date and
dispenser ID for the product dispense event will be relayed to the hub as a “non-badged dispense”.
In addition to communication of dispense event data, all NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT)S
proactively send their ID and battery status information to a Hub on an approximately hourly basis. If communication to
a Hub is lost, all NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT)S have the capability to store up to 512
events in their on-board memory.
4. NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) Status Information
The Dispenser Beacon proactively sends its battery level and status information to a Hub at least once per hour, or when
product is dispensed. This information can be accessed through the Dashboard, to generate a report showing Dispenser
Beacons with low battery level. If communication to a Hub is temporarily lost, each NEXA HHCM TOUCH FREE DISPENSER
BEACON (COMPACT) has the capability to store up to 512 events. If this number of events is exceeded before
communication to the Hub is restored, the oldest events will be overwritten, thus resulting in some loss of data.
4.1
Yellow LED – Successful Communication Between HCW Badge and Dispenser Beacon.
The Yellow LED, which flashes once during or immediately after a dispense event, indicates that the HCW badge
information has successfully been communicated to the Dispenser Beacon. The Dispenser Beacon will then send this
information to a Hub for relay on to a Gateway, and eventually to the offsite server for compilation and archiving.
4.2
When an Empty Product Bottle is Removed and a New Bottle is Installed
The Yellow LED will flash twice when the old bottle is removed, and the Yellow LED will flash once when a new bottle is
installed.
5. NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) Care and Maintenance
5.1
Handling
The NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) is an electronic device and should be handled with care.
Like other electronic devices such as a cell phone, the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) must
be protected from extreme heat, cold and moisture. Avoid handling the NEXA HHCM TOUCH FREE DISPENSER BEACON
(COMPACT) with wet hands or exposing it to water. Dropping or tossing the NEXA HHCM TOUCH FREE DISPENSER
BEACON (COMPACT) can result in damage to the internal electronics.
Ecolab P/N
9205-3026
Page
6 of 11
9205-3026 NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) USER’S GUIDE
5.2
Cleaning
Under normal conditions of use, the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) should not require
cleaning. On the infrequent occasions where the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) might
become soiled, it should be cleaned by wiping with a soft cloth. The cloth may be dry or slightly damp but not dripping
wet. Only the exterior of the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) may be cleaned. Do not
attempt to clean any interior surface of the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT), as this can
damage the circuitry. Do not use abrasive cleaners or spray cleaning products.
5.3
Battery Replacement
Typical Dispenser Beacon battery life is about 1 year but this may vary depending on use. When a Dispenser Beacon’s
battery is dead it will no longer communicate with other Ecolab HH CMS devices. The Ecolab HH CMS Dashboard
software also monitors the battery level of each NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT). It will send
an email alert to a designated maintenance person, assigned by the healthcare facility, when a NEXA HHCM TOUCH
FREE DISPENSER BEACON (COMPACT)’S batteries are low (20% or less remaining battery capacity). The maintenance
person should replace the batteries as soon as possible to prevent loss of data.
5.3.1
Supplies
The following supplies are required to replace the NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT)’S
battery:
1.
Two (2) alkaline AA Duracell® Coppertop Batteries
5.3.2
Battery Replacement Steps
The following steps describe how to remove and replace the batteries on the NEXA HHCM TOUCH FREE DISPENSER
BEACON (COMPACT):
1.
Open the dispenser by depressing the top latch button.
2.
Remove product bottle (if any) from the dispenser and set aside.
3.
Unscrew the battery compartment door and gently remove the old batteries.
4.
Once the battery compartment door has been removed, install two (2) AA alkaline batteries, aligning the
positive (+) and negative (-) terminals of the batteries with the corresponding signs displayed within the
battery compartment (Ecolab recommends that only Duracell® Coppertop batteries be used to power the
module.)
5.
Once the batteries have been installed, screw the battery compartment door back onto NEXA HHCM
TOUCH FREE DISPENSER BEACON (COMPACT).
6.
Replace the product bottle within the dispenser.
7.
Close the dispenser.
8.
Dispose of the old batteries. Check with the healthcare facility for the proper disposal procedure
Ecolab P/N
9205-3026
Page
7 of 11
9205-3026 NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) USER’S GUIDE
Appendix A - Certification and Safety Approvals
FCC Statement
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment causes harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following
measures:




Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modifications not expressly approved by Ecolab could void the user’s authority to operate the equipment.
RF Exposure: This equipment complies with FCC radiation exposure limits set forth for an Uncontrolled environment. This equipment
should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be
co-located or operating in conjunction with any other antenna or transmitter.
Industry Canada
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain
approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain
should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful
communication.
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et d'un
gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante.
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1)
this device may not cause interference, and (2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est
autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter
tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
This radio transmitter (IC: 10060A-9205-3026) has been approved by Industry Canada to operate with the antenna types listed below
with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in
this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
Le présent émetteur radio (IC: 10060A-9205-3026) a été approuvé par Industrie Canada pour fonctionner avec les
types d'antenne énumérés ci-dessous et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les
types d'antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour
l'exploitation de l'émetteur.
Magnetic Loop Antenna
Printed-F antenna, 6.3 dBi
Helical antenna, 1.9 dBi
FCC & IC Label Information
The FCC & IC label information that contains the FCC ID Number, IC ID Number, Device Model Number, and FCC Statement
“THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:
(1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE
Ecolab P/N
9205-3026
Page
8 of 11
9205-3026 NEXA HHCM TOUCH FREE DISPENSER BEACON (COMPACT) USER’S GUIDE
RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.” could be located on the front portion of
the module (See Figure 4).
FCC & IC Label
Information
Figure 4. FCC & IC Label Information
Ecolab P/N
9205-3026
Page
9 of 11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : geris-je
Create Date                     : 2017:12:05 09:22:17-05:00
Modify Date                     : 2017:12:05 09:23:03-05:00
XMP Toolkit                     : 3.1-701
Creator Tool                    : Microsoft Word - 72131442 - Manual Cover.docx
Metadata Date                   : 2017:12:05 09:23:03-05:00
Document ID                     : uuid:888882c4-5a68-8741-5f0e-4d9aca9266ff
Instance ID                     : uuid:17de0c96-3a57-e521-b5a0-32f1b4a6e347
Producer                        : Nuance PDF Create
Creator                         : geris-je
Title                           : Microsoft Word - 72131442 - Manual Cover.docx
Page Count                      : 12
EXIF Metadata provided by EXIF.tools
FCC ID Filing: Z9O-92053026

Navigation menu