Ecolink Intelligent Technology WST402 DOOR OR WINDOW SENSOR User Manual

Ecolink Intelligent Technology, Inc. DOOR OR WINDOW SENSOR

User Manual

Download: Ecolink Intelligent Technology WST402 DOOR OR WINDOW SENSOR User Manual
Mirror Download [FCC.gov]Ecolink Intelligent Technology WST402 DOOR OR WINDOW SENSOR User Manual
Document ID2088915
Application IDGa9ulJbgDExS9d5PFNpsuQ==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize18.49kB (231185 bits)
Date Submitted2013-10-01 00:00:00
Date Available2014-03-30 00:00:00
Creation Date2013-07-19 15:46:31
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2013-07-19 15:46:31
Document TitleUser Manual
Document CreatorMicrosoft® Word 2010
Document Author: Quinto

WST-402 Wireless Tilt Sensor
Installation Instructions & User Guide
Specifications
Frequency: 345MHz
Battery: One 3Vdc lithium CR123A (1550 mAh)
Battery life: 5-8 years
Tilt Sensor
Normally closed contact input terminals
Operating Temperature: 32°-120°F (0°-49°C)
Operating Humidity: 5-95% RH non condensing
Compatible with 2GIG and Honeywell receivers
Supervisory signal interval: 60 min (approx.)
Enrolling
To enroll the sensor, set your panel into program mode, refer to your specific alarm panel manual for details
on these menus. There are two triggers on this device and each uses a unique loop number. The tilt sensor is
assigned to loop 2 and the external input is assigned to loop 1.
To auto enroll the tilt sensor, you must ensure the tilt is orientated in the up
position (refer to picture and note location of arrow on the plastics). When
prompted by the panel, move the device until its orientated in the horizontal
position.
To auto enroll the external contact input, trigger the sensor by closing the circuit
between the two terminal inputs when prompted by the panel. This can be done
with a piece of wire, or if using a hardwired contact, by applying the magnet to
that contact.
This serial number is printed on the device if manual enrollment is desired.
The tilt sensor can operate as an “exit / entry” zone or a “perimeter zone”. Set
the zone type for the wireless tilt sensor in your panel.
Disclaimer: The external contact terminals, while fully functional, have not been
submitted to UL / ETL laboratories for verification of compliance with applicable
standards. Operation of the external contacts is outside of the scope of the ETL
listing for this product.
Tilt Sensitivity
The tilt sensor will activate when the device is approximately at a 45 degree angle. By moving the
actual ball sensor up or down you can adjust this angle by a few degrees.
Note that this device has a delay of approximately 1 second to eliminate false alarms cause by
wind and vibration commonly subjected to a large garage door.
Mounting
Included with this device are mounting screws and double sided tape. For reliable bonding with
the tape ensure the surface is clean and dry. Apply the tape to the sensor and then to the desired
location. Apply firm pressure for several seconds. It is not recommended to mount the tape at
temperatures below 50°F, although after 24 hours the bond will hold at low temperatures.
2055 Corte Del Nogal
Carlsbad, California 92011
1-855-632-6546
www.discoverecolink.com
© 2013 Ecolink Intelligent Technology Inc.
PN WST402 R1.03
REV DATE: 7/19/2013
FCC Compliance Statement
This equipment has been tested and found to comply with the limits for Class B digital devices, pursuant
to Part 15 of the FCC Rules. This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause undesired operation. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instruction manual, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:

Re-orient or relocate the receiving antenna

Increase the separation between the equipment and receiver

Connect the equipment to an outlet on a different circuit from the receiver

Consult the dealer or an experienced radio/TV contractor for help.
Warning: Changes or modifications not expressly approved by Ecolink Intelligent Technology Inc. could void
the user’s authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any
interference, including interference that may cause undesired operation of the device.
C’et appareil est conforme la norme d'Industrie Canada exempts de licence RSS. Son fonctionnement est
soumis aux deux conditions suivantes: (1) c’et appareil ne peut pas provoquer d'interférences, et (2) c’et
appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais
fonctionnement de la dispositif.
FCC ID:XQC-WST402
IC: 9863B-WST402
Warranty
Ecolink Intelligent Technology Inc . warrants that for a period of 5 years from the date of purchase that this
product is free from defects in material and workmanship. This warranty does not apply to damage caused by
shipping or handling, or damage caused by accident, abuse, misuse, misapplication, ordinary wear, improper
maintenance, failure to follow instructions or as a result of any unauthorized modifications.
If there is a defect in materials and workmanship under normal use within the warranty period Ecolink
Intelligent Technology Inc. shall, at its option, repair or replace the defective equipment upon return of
the equipment to the original point of purchase.
The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other
warranties, whether expressed or implied and of all other obligations or liabilities on the part of Ecolink
Intelligent Technology Inc. neither assumes responsibility for, nor authorizes any other person
purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or
liability concerning this product.
The maximum liability for Ecolink Intelligent Technology Inc. under all circumstances for any warranty issue
shall be limited to a replacement of the defective product . It is recommended that the customer check their
equipment on a regular basis for proper operation.
2055 Corte Del Nogal
Carlsbad, California 92011
1-855-632-6546
www.discoverecolink.com
© 2013 Ecolink Intelligent Technology Inc.
PN WST402 R1.03
REV DATE: 7/19/2013

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 2
Language                        : en-US
Tagged PDF                      : Yes
Author                          : Quinto
Creator                         : Microsoft® Word 2010
Create Date                     : 2013:07:19 15:46:31-07:00
Modify Date                     : 2013:07:19 15:46:31-07:00
Producer                        : Microsoft® Word 2010
EXIF Metadata provided by EXIF.tools
FCC ID Filing: XQC-WST402

Navigation menu