Edgecore Networks ECWO5320 802.11ac Outdoor Dual Band Access Point User Manual Quick Start Guide

Edgecore Networks Corporation 802.11ac Outdoor Dual Band Access Point Quick Start Guide

User Manual.pdf

– 1 –
Quick Start Guide
802.11ac Outdoor Stand-Alone/Cloud-Based Access Point
ECWO3300, 4300, 5300 Series
The ECWO3300/4300/5300 Series are a family of single- and dual-band (2.4/5 GHz)
access points (APs) that are housed in a waterproof enclosure for mounting
outdoors. The units include a built-in mounting bracket for attaching to a 1.5 to 6-
inch pole and they can be powered through their Ethernet cable connection from a
power injector module that is installed indoors.
The ECWO3300/4300/5300 Series includes these models:
ECWO3320 — 2.4 GHz stand-alone AP with internal antennas
ECWO3320-L — 2.4 GHz controller-based AP with internal antennas
ECWO3324 — 2.4 GHz stand-alone AP with external antennas
ECWO3324-L — 2.4 GHz controller-based AP with external antennas
ECWO4320 — 5 GHz stand-alone AP with internal antennas
ECWO4320-L — 5 GHz controller-based AP with internal antennas
ECWO4324 — 5 GHz stand-alone AP with external antennas
ECWO4324-L — 5 GHz controller-based AP with external antennas
ECWO5320 — Dual-band stand-alone AP with 5 GHz internal antennas
ECWO5320-L — Dual-band controller-based AP with 5 GHz internal antennas
ECWO5324 — Dual-band stand-alone AP with external antennas
ECWO5324-L — Dual-band controller-based AP with external antennas
Note:
For Safety and Regulatory information, refer to the Safety and Regulatory
Information document included with the AP.
E052014-CS-R01
150200000891A
www.edge-core.com
ECWO3320-C — 2.4 GHz cloud-based AP with internal antennas
ECWO3324-C — 2.4 GHz cloud-based AP with external antennas
ECWO4320-C — 5 GHz cloud-based AP with internal antennas
ECWO4324-C — 5 GHz cloud-based AP with external antennas
ECWO5320-C — Dual-band cloud-based AP with 5 GHz internal antennas
ECWO5324-C — Dual-band cloud-based AP with external antennas
– 1 –
Safety and Regulatory Information
802.11ac Outdoor Stand-Alone/Cloud-Based Access Point
ECWO3300, 4300, 5300 Series
This document provides information on switch safety, regulatory statements and
compliances. It includes these sections:
“Compliances and Safety Statements” on page 1
Warnings and Cautionary Messages” on page 7
Compliances and Safety Statements
FCC Class B This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. This transmitter must not be co-
located or operating in conjunction with any other antenna or transmitter.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user
is encouraged to try to correct the interference by one of the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected
Consult the dealer or an experienced radio/TV technician for help
FCC Caution: Any changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate this
equipment.
E052014-CS-R01
150200000892A
www.edge-core.com
Safety and Regulatory Information
– 2 –
This transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
Operation within the 5.15 ~ 5.25GHz / 5.47 ~5.725GHz frequency range is restricted
to an indoor environment. The 5600-5650MHz band is disabled by software during
manufacturing and cannot be changed by the end user. This device meets all the
other requirements specified in Part 15E, Section 15.407 of the FCC Rules.
Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance 20 cm between the radiator and your body.
Professional Installation Instructions
1. Installation personal
This product is designed for specific applications and needs to be installed by a
qualified person who has RF and related rules knowledge. The general user shall
not attempt to install or change the settings.
2. Installation location
The product shall be installed at a location where the radiating antenna can be kept
20 cm from nearby persons in normal operation conditions to meet regulatory RF
exposure requirements.
3. External antenna
Use only the antennas that have been approved by the applicant. Non-approved
antenna(s) may produce unwanted spurious or excessive RF transmitting power,
which may lead to the violation of FCC/IC limits and is prohibited.
4. Installation procedure
Please refer to user's manual for details.
5. Warning
Please carefully select the installation position and make sure that the final output
power does not exceed the limits set forcth in relevant rules. Violation of the rules
could lead to serious federal penalties.
Instructions d'installation professionnelle
1. Installation
Ce produit est destine a un usage specifique et doit etre installe par un personnel
qualifie maitrisant les radiofrequences et les regles s'y rapportant. L'installation et
les reglages ne doivent pas etre modifies par l'utilisateur final.
Safety and Regulatory Information
– 3 –
2. Emplacement d'installation
En usage normal, afin de respecter les exigences reglementaires concernant
l'exposition aux radiofrequences, ce produit doit etre installe de facon a respecter
une distance de 20 cm entre l'antenne emettrice et les personnes.
3. Antenn externe.
Utiliser uniiquement les antennes approuvees par le fabricant. L'utilisation d'autres
antennes peut conduire a un niveau de rayonnement essentiel ou non essentiel
depassant les niveaux limites definis par FCC/IC, ce qui est interdit.
4. Procedure d'installation
Consulter le manuel d'utilisation.
5. Avertissement
Choisir avec soin la position d'installation et s'assurer que la puissance de sortie ne
depasse pas les limites en vigueur. La violation de cette regle peut conduire a de
serieuses penalites federales.
CE Mark CE Mark Declaration of Conformance for EMI and Safety (EEC)
This is a class B product. In a domestic environment, this product may cause radio
interference, in which case the user may be required to take adequate measures.
National Restrictions
This device is intended for home and office use in all EU countries (and other
countries following the EU directive 1999/5/EC) without any limitation except for
the countries mentioned below:
Note:
Do not use the product outdoors in France.
Country Restriction Reason/Remark
Bulgaria None General authorization required for outdoor use and
public service
France Outdoor use limited
to 10 mW e.i.r.p.
within the band
2454-2483.5 MHz
Military Radiolocation use. Refarming of the 2.4 GHz band
has been ongoing in recent years to allow current relaxed
regulation. Full implementation planned 2012
italy None If used outside of own premises, general authorization is
required
Luxembourg None General authorization required for network and service
supply(not for spectrum)
Norway Implemented This subsection does not apply for the geographical area
within a radius of 20 km from the centre of Ny-Ålesund
Russian
Federation None Only for indoor applications
Safety and Regulatory Information
– 4 –
Europe - EU Declaration of Conformity
This device complies with the essential requirements of the R&TTE Directive 1999/
5/EC. The following test methods have been applied in order to prove presumption
of conformity with the essential requirements of the R&TTE Directive 1999/5/EC:
EN 60950-1:2006 + A11: 2009
Safety of Information Technology Equipment.
EN 300 328 V1.7.1: 2006-10
Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband
transmission systems; Data transmission equipment operating in the 2,4 GHz
ISM band and using wide band modulation techniques; Harmonized EN
covering essential requirements under article 3.2 of the R&TTE Directive.
EN 301 489-17 V1.8.1/ 2008-04
EN 301 489-17 V2.1.1/ 2009-05
Electromagnetic compatibility and Radio spectrum Matters (ERM);
Electromagnetic Compatibility (EMC) standard for radio equipment and
services; Part 17: Specific conditions for 2.4 GHz wideband transmission
systems and 5 GHz high performance RLAN equipment.
EN 55022: 2006 + A1: 2007
Limits and methods of measurement of radio disturbance characteristics of
information technology equipment.
EN 55024: 1998 + A1: 2001 + A2: 2003
Information technology equipment immunity characteristics limits and
methods of measurement.
EN 62311: 2008
Assessment of electronic and electrical equipment related to human exposure
restrictions for electromagnetic fields (0 Hz - 300 GHz).
This device is a 2.4 GHz wideband transmission system (transceiver), intended for
use in all EU member states and EFTA countries, except in France and Italy where
restrictive use applies.
In Italy the end-user should apply for a license at the national spectrum authorities
in order to obtain authorization to use the device for setting up outdoor radio links
and/or for supplying public access to telecommunications and/or network services.
This device may not be used for setting up outdoor radio links in France and in
some areas the RF output power may be limited to 10 mW EIRP in the frequency
range of 2454 - 2483.5 MHz. For detailed information the end-user should contact
the national spectrum authority in France.
Safety and Regulatory Information
– 5 –
The Declaration of Conformity (DoC) can be obtained from www.edge-core.com ->
support -> download -> declarations & certifications.
This equipment may be operated in:
Bulgarian
Български
С настоящето, Edge-Core декларира, че това безжично устройство е в съответствие
със съществените изисквания и другите приложими разпоредби на Директива 1999/
5/EC.
Czech
Česky
Edge-Core tímto prohlašuje, že tento Radio LAN device je ve shodě se základními
požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES.
Danish
Dansk
Undertegnede Edge-Core erklærer herved, at følgende udstyr Radio LAN device
overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF
Dutch
Nederlands
Hierbij verklaart Edge-Core dat het toestel Radio LAN device in overeenstemming is met
de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG
Bij deze Accton dat deze Radio LAN device voldoet aan de essentiële eisen en aan de
overige relevante bepalingen van Richtlijn 1999/5/EC.
English Hereby, Edge-Core, declares that this Radio LAN device is in compliance with the
essential requirements and other relevant provisions of Directive 1999/5/EC.
Estonian
Eesti
Käesolevaga kinnitab Edge-Core seadme Radio LAN device vastavust direktiivi 1999/5/
EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele.
Finnish
Suomi
Valmistaja Edge-Core vakuuttaa täten että Radio LAN device tyyppinen laite on direktiivin
1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen.
French
Français
Par la présente Edge-Core déclare que l'appareil Radio LAN device est conforme aux
exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE
German
Deutsch
Hiermit erklärt Edge-Core, dass sich dieser/diese/dieses Radio LAN device in
Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten
Vorschriften der Richtlinie 1999/5/EG befindet". (BMWi)
Hiermit erklärt Edge-Core die Übereinstimmung des Gerätes Radio LAN device mit den
grundlegenden Anforderungen und den anderen relevanten Festlegungen der Richtlinie
1999/5/EG. (Wien)
Greek
Ελληνική
με την παρουσα Edge-Core δηλωνει οτι radio LAN device συμμορφωνεται προσ τισ
ουσιωδεισ απαιτησεισ και τισ λοιπεσ σχετικεσ διαταξεισ τησ οδηγιασ 1999/5/εκ.
Hungarian
Magyar
Alulírott, Edge-Core nyilatkozom, hogy a Radio LAN device megfelel a vonatkozó
alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak.
Italian
Italiano
Con la presente Edge-Core dichiara che questo Radio LAN device è conforme ai requisiti
essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE.
Latvian
Latviski
Ar šo Edge-Core deklarē, ka Radio LAN device atbilst Direktīvas 1999/5/EK būtiskajām
prasībām un citiem ar to saistītajiem noteikumiem.
Safety and Regulatory Information
– 6 –
NCC Statement
(Taiwan)
經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅
自變更頻率、加大功率或變更原設計之特性及功能。
低功率射頻電機之使用不得影響飛航安全及干擾合法通信;經發現有干擾現象
時,應立即停用,並改善至無干擾時方得繼續使用。前項合法通信,指依電信
法規定作業之無線電通信。低功率射頻電機須忍受合法通信或工業、科學及醫
療用電波輻射性電機設備之干擾
5.25 ~ 5.35GHz 限室內使用
專業安裝警語 ( 固定式點對點操作 )
此器材須經專業安裝並限用於固定式點對點操作。
” 本器材須經專業工程人員安裝及設定,始得設置使用,且不得直接販售給一
般消費者 ”
Lithuanian
Lietuvių
Šiuo Edge-Core deklaruoja, kad šis Radio LAN device atitinka esminius reikalavimus ir
kitas 1999/5/EB Direktyvos nuostatas.
Maltese
Malti
Hawnhekk, Edge-Core, jiddikjara li dan Radio LAN device jikkonforma mal-ħtiġijiet
essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 1999/5/EC.
Polish
Polski
Niniejszym Edge-Core oświadcza, że Radio LAN device jest zgodny z zasadniczymi
wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/EC.
Portuguese
Português
Edge-Core declara que este Radio LAN device está conforme com os requisitos
essenciais e outras disposições da Directiva 1999/5/CE.
Romanian
Romană
Edge-Core declară că acest dispozitiv fără fir respectă cerinţele esenţiale precum şi alte
dispoziţii relevante ale Directivei 1999/5/EC.
Slovak
Slovensky
Edge-Core týmto vyhlasuje, že Radio LAN device spĺňa základné požiadavky a všetky
príslušné ustanovenia Smernice 1999/5/ES.
Slovenian
Slovensko
Edge-Core izjavlja, da je ta radio LAN device v skladu z bistvenimi zahtevami in ostalimi
relevantnimi določili direktive 1999/5/ES.
Spanish
Español
Por medio de la presente Edge-Core declara que el Radio LAN device cumple con los
requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la
Directiva 1999/5/CE
Swedish
Svenska
Härmed intygar Edge-Core att denna Radio LAN device står I överensstämmelse med de
väsentliga egenskapskrav och övriga relevanta bestämmelser som framgår av direktiv
1999/5/EG.
Turkish
Turk
Edge-Core bu kablosuz cihazın temel gereksinimleri ve 1999/5/EC yonergesindeki ilgili
koşulları karşıladığını beyan eder.
Safety and Regulatory Information
– 7 –
Warnings and Cautionary Messages
Warning
:
This product does not contain any serviceable user parts.
Warning
:
Installation and removal of the unit must be carried out by qualified
personnel only.
Warning
:
When connecting this device to a power outlet, connect the field
ground lead on the tri-pole power plug to a valid earth ground line to prevent
electrical hazards.
Caution
:
Wear an anti-static wrist strap or take other suitable measures to prevent
electrostatic discharge when handling this equipment.
Caution
:
Do not plug a phone jack connector in the RJ-45 port. This may damage
this device.
Caution
:
Use only twisted-pair cables with RJ-45 connectors that conform to FCC
standards.
Caution:
The planning and installation of the AP requires professional personnel
that are trained in the installation of radio transmitting equipment. The user is
responsible for compliance with local regulations concerning items such as
antenna power, use of lightning arrestors, grounding, and radio mast or tower
construction. Therefore, it is recommended to consult a professional contractor
knowledgeable in local radio regulations prior to equipment installation.
Caution
:
Do not install the power injector outdoors. The unit is for indoor
installation only.
Caution
:
Install lightning protection at the power injector end of the Ethernet
cable, use a lightning arrestor immediately before the cable enters the building.
Caution
:
Be sure that grounding is available and that it meets local and national
electrical codes. Grounding the AP must be performed by a professional installer.
Caution
:
Grounding the outdoor-rated Ethernet cable must be performed by a
professional installer in conformance with local safety regulations.
Quick Start Guide
– 2 –
Follow the steps in this guide to install the AP in your network.
Caution:
The planning and installation of the AP requires professional personnel
that are trained in the installation of radio transmitting equipment. The user is
responsible for compliance with local regulations concerning items such as
antenna power, use of lightning arrestors, grounding, and radio mast or tower
construction. Therefore, it is recommended to consult a professional contractor
knowledgeable in local radio regulations prior to equipment installation.
1. Unpack the AP Unpack the AP and check the package contents.
ECWO3300, 4300, or 5300 Series Outdoor Access Point
Pole-mounting kit — includes two steel-band clamps
PoE power injector with power cord — either US, Continental Europe or UK
Documentation —Quick Start Guide and Regulatory and Safety Information
2. Mount the AP After planning your installation, mount the unit on a pole, mast, or tower using the
included two steel-band clamps. Also install the external antennas required for
your wireless service.
Pole Mounting
Feed the steel-band clamps through the
integrated pole-mount bracket points on
the back of the AP.
Fasten the steel-band clamps around the
pole to secure the AP to the pole.
1
2
1
2
Quick Start Guide
– 3 –
Note:
The number of available 2.4 GHz or 5 GHz external antenna connectors
depends on the specific model.
3. Connect Cables Connect outdoor-rated Ethernet cable to the 1000BASE-T RJ-45 ETH0 (PoE) port on
the unit.
4. Connect Power Install the PoE power injector indoors. Connect the power injector to the Ethernet
cable from the AP, to a port on a local LAN switch, and then to an AC power source.
Caution:
The power injector module is designed for indoor use only. Never mount
the power injector outside with the AP unit.
Attach External Antennas
Remove the front port cover by
pushing the locking tab up and then
sliding the cover off.
Connect external antennas to the
AP’s 5 GHz RP-SMA connectors using
RF coaxial cable provided in the
antenna package.
Connect external antennas to the
AP’s 2.4 GHz RP-SMA connectors
using RF coaxial cable provided in the
antenna package.
1
2
3
23
1
Connect outdoor-rated Category 5e
or better cable to the left-side RJ-45
ETH0 (PoE) port.
(Optional) Connect a local LAN
switch or computer to the right-side
ETH1 100BASE-TX RJ-45 port.
Pass the cables through the access
holes at the bottom of the AP.
Replace the port cover on the AP and
push the locking tab down to secure
it in place.
1
2
3
4
4
3
2
1
Quick Start Guide
– 4 –
Note
:
Connecting the Ethernet cable from the AP to the injector module powers
on the unit.
5. Verify AP Operation Verify basic AP operation by checking the system LEDs.
The power LED should be on green, the ETH0 port LED on/blinking green, and the
2.4GHz/5GHz wireless LED on/blinking green (2.4 GHz) or blue (5 GHz).
Connect the Ethernet cable from the AP to
the “POE” port on the power injector.
Connect Ethernet cable from the “LAN” port
on the power injector to a LAN switch.
Connect the power cord to a nearby AC
power source (100-240 VAC, 50/60 Hz).
1
2
3
3
2
1
1
2
3
4
5
Quick Start Guide
– 5 –
6. Connect to the Web
User Interface
The stand-alone APs offer a web-based management interface for the
configuration of all the unit’s features.
You can make initial configuration changes by connecting a PC directly to the AP’s
ETH1 RJ-45 port. The AP has a default management IP address of 192.168.2.1 and a
subnet mask of 255.255.255.0. You must set your PC IP address to be on the same
subnet as the AP (that is, the PC and AP addresses must both start 192.168.2.x).
Log in to the web interface using the default settings:
Login Name — root
Password — admin123
For more information on stand-alone AP configuration using the web interface,
refer to the Management Guide.
For more information on cloud-based AP configuration, refer to the relevant
wireless controller documentation.
Quick Start Guide
– 6 –
Hardware Specifications
Item Specification
Chassis
Size (H x W x D:) 280.86 x 91.85 x 50.35 mm (11.06 x 3.62 x 1.98 inches)
Weight 0.75 kg (1.65 lb)
Temperature Operating: -20 °C to 65 °C (-4 °F to 149 °F)
Storage: -30 °C to 80 °C (-22 °F to 176 °F)
Humidity Operating: 15% to 95% (non-condensing)
Waterproof/Dustproof IP55
Network Interfaces
Ports ETH0 (PoE) RJ-45 Port: 1000BASE-T, passive PoE
ETH1 RJ-45 Port: 100BASE-TX
2.4 GHz Radio IEEE 802.11b/g/n
5 GHz Radio IEEE 802.11a/n/ac
Radio Frequencies 2400 ~ 2483.5 MHz
2412 ~ 2472 MHz
5745 ~ 5825 MHz (China)
5180 ~ 5320 MHz (ETSI)
5500 ~ 5700 MHz (ETSI)
Power Supply
PoE Input Power 24 VDC, 1.0 A
Power Consumption 24 W maximum
Power Injector Module 100-240 VAC, 50-60 Hz, auto-sensing
Regulatory Compliances
Radio EN 300 328 V1.8.1:2012
EN 301 893 V1.7.1:2012
EN 301 489-1 V1.9.2 (2011-09)
EN 301 489-7 V1.3.1:2005
FCC Part 15C 15.247/15.207 (2.4-2.4835GHz, 5.725-5.850GHz)
FCC Part 15E 15.407 (5.150GHz-5.250GHz)
Emissions EN 55022 2010+AC:2011
EN 61000-3-2 2006+A1:2009+A2:2009
FCC Class B Part 15
Immunity EN 55024 : 2010
EN 61000-4-2 : 2009
Safety UL/CUL (CSA/UL60950-1, CSA/UL60950-22)
CB (IEC60950-1, IEC60950-22)

Navigation menu