PL44

Dynamic Supercardioid
Vocal Microphone

Key Features:
•	
•	
•	
•	
•	
•	

Sonic voicing for transparency and high-mid lift
Plug-and-play placement of vocals in any mix
Supercardioid polar pattern
Powerful Neodymium magnet structure
Shock mounted capsule and low handling noise
Fine mesh Memraflex™ grille

General Description:
Thank you for purchasing the Electro-Voice® PL44. This product is
a professional-grade supercardioid dynamic microphone designed
for plug-and-play placement of vocals in any mix. The PL44’s highmid frequency content design lifts the vocal into the precise spot in
the mix where they need to be, resulting in fast and effective vocal
placement. With its extremely accurate frequency response, the
PL44’s sonic performance is robust and articulate delivering highly
detailed imaging across the critical vocal frequency range. The
enhanced isolation provided by its supercardioid polar pattern is
an excellent defense against system feedback and cross-talk bleed
emanating from other nearby sound sources. The result is higher
gain before feedback and cleaner stage mixes. Although designed
to be a vocal microphone for music and spoken word, the PL44 will
also function well as an instrument or amplifier microphone where a
dynamic element capsule would be desired.

Application Notes:
As with most directional microphones, the low frequency response
of the PL44 microphone varies with the distance from the sound
source. Known as “proximity effect”, the bass response of the
microphone increases as the working distance to the microphone is
reduced. This “bass boost” is only audible when working at distances
closer than 6 inches. Using this microphone at distances greater
than 6 inches provides minimal coloration from proximity effect.
Proximity effect can be used to your advantage when a thin voice
is being recorded. As the vocalist decreases their working distance
to the microphone, the low frequency content is enhanced. Closeup positioning of the microphone will also reduce the potential for
feedback from the sound reinforcement system. When close-talked,
the bass-boost provides an increase in overall microphone output
level. The mixer gain may be proportionately reduced, resulting in
a reduction of the system’s sensitivity to feedback caused by the
sound entering the microphone from the loudspeakers.

Warranty:
This Electro-Voice® PL44 product is guaranteed against malfunction
due to defects in materials or workmanship for a period of three (3)
years from the date of original purchase. Please refer to the Limited
Warranty card included with your product for further warranty information.

Technical Specifications:
Element Type: Dynamic, Neodymium Magnet
Structure
Frequency Response: 80 Hz - 18,000 Hz
Polar Pattern: Supercardioid
Sensitivity, Open Circuit 2.2 mV/Pa (-53 dBV)
Voltage, 1 kHz:
Polarity: Positive pressure on diaphragm
produces positive voltage on pin 2
relative to pin 3
Rated Impedance: 600 ohms
Microphone Connector: 3-pin, XLR-type
Finish: Textured black satin handle with
MemraflexTM grille
Dimensions: Length = 7.33” (186.2 mm)
Width = 2.00” (50.7 mm)
Shank = 0.93” (23.6 mm)
Accessories Included: Stand adapter with Euro-thread
insert, Soft zippered gig bag
Net Weight: 10.0 oz (282 g)
Shipping Weight: 18.9 oz (536 g)

Frequency Response:

Polar Response:

Microphone Use and Placement

Please note that micing techniques are a matter of personal preference. These are merely guidelines to assist in the placement of the
microphone to gain optimal performance.

Usage					

Optimal Placement

Vocals 					

0 to 6 inches away, aimed directly at the sound source.

Spoken Word				

5 to 10 inches away, aimed directly at the sound source.

Standard Placement & Use Guidelines
1. Always point the microphone at the desired source of sound, and away from any unwanted sources.
2. The microphone should be located close to the sound source to minimize interference from other potential sound sources.
3. Use the 3-to-1 rule when using multiple microphones. Place each microphone three times farther from other microphones as from 	
the desired sound source.
4. Minimize over-handling of the microphone to reduce unwanted mechanical noise.

Dimension Drawing:
PL44 Part Numbers

Electro-Voice®
12000 Portland Avenue South, Burnsville, MN 55337
Phone: 952/884-4051, Fax: 952/884-0043

www.electrovoice.com
© Bosch Communications Systems	
Part Number LIT000244 Rev B

08/2008

•	 PRD000158000	
	

PL44, Dynamic Supercardioid Vocal		
Microphone

•	 ACC000045000	
	

SAPL-1, Replacement Microphone Stand 	
Adapter

•	 ACC000048001	

WSPL-1, Optional Foam Windscreen, Black

U.S.A. and Canada only. For customer orders, contact Customer Service at:
800/392-3497 Fax: 800/955-6831
Europe, Africa, and Middle East only. For customer orders, contact Customer Service at:
+ 49 9421-706 0 Fax: + 49 9421-706 265
Other Internatonal locations. For customer orders, Contact Customer Service at:
+ 1 952 884-4051 Fax: + 1 952 887-9212
For warranty repair or service information, contact the Service Repair department at:
800/685-2606
For technical assistance, contact Technical Support at: 866/78AUDIO
Specifications subject to change without notice.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c006 1.236519, Wed Jun 14 2006 08:31:24
Instance ID                     : uuid:a9b9b0a6-f872-4f53-8f97-83fc1625af73
Document ID                     : adobe:docid:indd:f66030bc-73ae-11dd-a1bb-927f96265e7b
Rendition Class                 : proof:pdf
Derived From Instance ID        : 7360591b-2d92-11dd-9de8-c6cd43ffe229
Derived From Document ID        : adobe:docid:indd:7360591a-2d92-11dd-9de8-c6cd43ffe229
Manifest Link Form              : ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 72.00
Manifest Placed Y Resolution    : 72.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches
Manifest Reference Instance ID  : uuid:fe3fd946-3f37-11da-9ce7-000d936d2e08, uuid:C29D8FED8946DC118DDAECA10C30D097
Manifest Reference Document ID  : uuid:1eee1406-6652-11d9-a18c-000d936d2e08, uuid:C19D8FED8946DC118DDAECA10C30D097
Create Date                     : 2008:08:26 15:39:48-05:00
Modify Date                     : 2008:08:26 15:39:51-05:00
Metadata Date                   : 2008:08:26 15:39:51-05:00
Creator Tool                    : Adobe InDesign CS3 (5.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 10895 bytes, use -b option to extract)
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS3 (5.0)
EXIF Metadata provided by EXIF.tools

Navigation menu