Installation Instructions
Electrolux Front-Load Gas & Electric Dryer
Instrucciones de Instalacion
Secadora eléctrica y a gas de carga frontal Electrolux
Instructions d’installation
Sécheuse à gaz et à l’électricité à chargement frontal Electrolux
137018200 A (0801)

2Finding Information
Please read and save this guide
Thank you for choosing Electrolux, the new premium brand in home appliances. These Installation
Instructions are part of our commitment to customer satisfaction and product quality throughout the life
of your new appliance.
We view your purchase as the beginning of a relationship. To ensure our ability to continue serving you,
please use this page to record important product information.
Questions?
For toll-free telephone support in the U.S. and Canada: 1-877-4ELECTROLUX (1-877-435-3287)
For online support and product information visit http://www.electroluxappliances.com
Table of contents
Finding information ......................................................... 2
SAFETY .......................................................................... 3
• Pre-installationrequirements ...................................... 3
Installation requirements .............................................4-9
• Electricalsystemrequirements ................................... 4
• Gassupplyrequirements ............................................ 5
• Exhaustsystemrequirements .................................5-7
• Mobilehomeinstallation ............................................. 7
• Clearancerequirements.............................................. 8
• Installeddimensions ................................................... 9
Installation Instructions ...........................................10-18
• Electricalinstallation ................................................. 10
• Groundingrequirements-Electricdryer(USA) ........ 10
• Groundingrequirements-Electricdryer(Canada) ... 11
• Groundingrequirements-Gasdryer ........................ 11
• Electricalconnection-Electricdryer(3-wirecord) ... 12
• Electricalconnection-Electricdryer(4-wirecord) ... 13
• Gasconnection ........................................................ 14
• Waterconnection(SteamModelonly) .................15-16
• Generalinstallation ................................................... 17
• Performinginstallationcycle .................................... 18
Reversing door ........................................................19-24
Options ......................................................................... 25
• Accessories .............................................................. 25
• Replacementparts ................................................... 25
Notes ............................................................................ 26
©2008ElectroluxMajorAppliances All rights reserved.
Purchasedate
Electroluxmodelnumber
Electroluxserialnumber
Keep a record for quick reference
NOTE
RegisteringyourproductwithElectroluxenhances
our ability to serve you. You can register online at
www.electroluxappliances.com or by dropping
yourProductRegistrationCardinthemail.

3
Safety
Important Safety Instructions
Recognize safety symbols, words and
labels
Safety items throughout this manual are labeled
withaWARNINGorCAUTIONbasedontherisk
type as described below:
Read all of the following instructions before
installing and using this appliance:
Destroy the carton and plastic bags after the dryer •
is unpacked. Children might use them for play.
Cartons covered with rugs, bedspreads, or plastic
sheets can become airtight chambers causing suf-
focation.Placeallmaterialsinagarbagecontainer
or make materials inaccessible to children.
Clothes dryer installation and service must be •
performed by a qualified installer, service agency
or the gas supplier.
Install the clothes dryer according to the manu-•
facturer’s instructions and local codes.
The electrical service to the dryer must conform •
with local codes and ordinances and the latest
edition of the National Electrical Code, ANSI/
NFPA70,orinCanada,theCanadianelectrical
code C22.1 part 1.
The gas service to the dryer must conform with •
local codes and ordinances and the latest edi-
tionoftheNationalFuelGasCodeANSIZ223.1,
orinCanada,CAN/ACGB149.1-2000.
ThedryerisdesignedunderANSIZ21.5.1or•
ANSI/UL2158-CAN/CSAC22.2No.112(latest
editions)forHOMEUSEonly.Thisdryerisnot
recommended for commercial applications such
as restaurants, beauty salons, etc.
The instructions in this manual and all other •
literature included with this dryer are not meant
to cover every possible condition and situation
thatmayoccur.Goodsafepracticeandcaution
MUSTbeappliedwheninstalling,operatingand
maintaining any appliance.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.•
Do not touch any electrical switch; do not use •
any phone in your building.
Clear the room, building or area of all occupants.•
Immediately call your gas supplier from a neigh-•
bor’s phone. Follow the gas supplier’s instruc-
tions.
If you cannot reach your gas supplier, call the fire •
department.
Save these instructions for future
reference.
This symbol alerts you to situa-
tions that may cause serious body
harm, death or property damage.
This symbol alerts you to situa-
tionsthatmaycausebodilyinjury
or property damage.
WARNING
For your safety the information in this manual
must be followed to minimize the risk of fire
orexplosionortopreventpropertydamage,
personalinjuryorlossoflife.Do not store or use
gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
Pre-installation requirements
Adjustable
pliers
4 inch, rigid metal or
semi-rigid metal exhaust duct work
4i hiid tl
Adjustable
wrench
Metal foil tape
(not duct tape)
External
vent hood
or
Carpenter’s level
Phillips, straight, &
square bit screwdrivers
Universal wrench
supplied with
matching washer
Pipe wrench
for gas
supply
gas line
shutoff valve
(gas dryer)
or
LP-resistant
thread tape
(for natural gas
or LP supply)
½” NPT union flare
adapters (x2) and
flexible gas supply line
(gas dryer)
3-wire or 4-wire
240 volt cord kit
(electric dryer)
4 in.
(10.2 cm)
clamp
Tools and materials needed for installation:

4Installation Requirements
IMPORTANT
This dryer is internally grounded to neutral unless it
wasmanufacturedforsaleinCanada.Grounding
throughtheneutrallinkisprohibitedfor:(1)new
branchcircuitinstallations,(2)mobilehomes,(3)
recreationalvehicles,and(4)areaswherelocal
codes do not permit grounding through the neutral. NOTE
Dryers manufactured for sale in Canada have
factory-installed, 4-wire power supply cord
(NEMA14-30R).
Electrical system requirements
Electrical requirements for electric dryer:
CIRCUIT - Individual 30 amp. branch circuit
fused with 30 amp. time delay fuses or circuit
breakers. Use separately fused circuits for
washer and dryer. DO NOT operate a washer
and a dryer on the same circuit.
POWERSUPPLY-3-wireor4-wire,240volt,
singlephase,60Hz,AlternatingCurrent.
3-WIREPOWERSUPPLYCORDKIT(notsupplied)
OUTLETRECEPTACLE-NEMA10-30RorNEMA
14-30R receptacle to be located so the power
supply cord is accessible when the dryer is in the
installed position.
GROUNDINGCONNECTION-See“Grounding
requirements” in Electrical Installation section.
ThedryerMUSTemploya3-conductorpower
supplycordNEMA10-30typeSRDTratedat
240 volt AC minimum, 30 amp, with 3 open
end spade lug connectors with upturned ends
or closed loop connectors and marked for use
4-WIREPOWERSUPPLYCORDKIT(notsupplied)
ThedryerMUSTemploya4-conductorpower
supplycordNEMA14-30typeSRDTorST(as
required)ratedat240voltACminimum,30amp,
with 4 open end spade lug connectors with
upturned ends or closed loop connectors and
marked for use with clothes dryers. For 4-wire
cord connection instructions see ELECTRICAL
CONNECTIONSFORA4-WIRESYSTEM.
Electrical requirements for gas dryer:
CIRCUIT - Individual, properly polarized and
grounded 15 amp. branch circuit fused with 15
amp. time delay fuse or circuit breaker.
POWERSUPPLY-2-wire,withground,120volt,
singlephase,60Hz,AlternatingCurrent.
POWERSUPPLYCORD-Thedryerisequipped
with a 120 volt 3-wire power cord.
GROUNDINGCONNECTION-See“Grounding
requirements” in Electrical Installation section.
Grounding type
wall receptacle
Power cord with
3-prong grounded plug
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
3-wire receptacle
(NEMAtype10-30R)
4-wire receptacle
(NEMAtype14-30R)
NOTE
Becauseofpotentiallyinconsistentvoltagecapabilities,theuseofthisdryerwithpowercreated
by gas powered generators, solar powered generators, wind powered generators or any other
generator other than the local utility company is not recommended.
with clothes dryers. For 3-wire cord connection
instructions see ELECTRICAL CONNECTIONS
FORA3-WIRESYSTEM.

5
Installation Requirements
WARNING
FIREHAZARD
Failure to follow these instructions can create
excessivedryingtimesandrehazards.
WARNING
FIREHAZARD
Donotinstallaclothesdryerwithexibleplastic
ormetalfoilventingmaterials.Flexibleventing
materials are known to collapse, be easily
crushed and trap lint. These conditions will
obstruct clothes dryer airflow and increase the
risk of fire.
Exhaust system requirements
If your present system is made up of plastic
duct or metal foil duct, replace it with a rigid or
semi-rigid metal duct. In Canada and the United
Statesifmetal(foiltype)ductisinstalled,itmust
be of a specific type identified by the appliance
manufacturer as suitable for use with clothes
dryers and in the United States must also comply
with the Outline for Clothes Dryer Transition Duct,
UL standard 2158A. Also, ensure the present duct
is free of any lint prior to installing dryer duct.
Useonly4inch(10.2cm)diameter(minimum)rigid
orexiblemetalductandapprovedventhood
whichhasaswing-outdamper(s)thatopenwhen
the dryer is in operation. When the dryer stops,
the dampers automatically close to prevent drafts
and the entrance of insects and rodents. To avoid
restricting the outlet, maintain a minimum of 12
inches(30.5cm)clearancebetweentheventhood
and the ground or any other obstruction.
Correct Incorrect
Correct Incorrect
The following are specific requirements
for proper and safe operation of your
dryer.
Gas supply requirements
WARNING
EXPLOSIONHAZARD
Uncoated copper tubing will corrode when
subjectedtonaturalgas,causinggasleaks.
Use ONLY black iron, stainless steel, or plastic-
coated brass piping for gas supply.
1. InstallationMUSTconformwithlocalcodes,or
in the absence of local codes, with the National
FuelGasCode,ANSIZ223.1(latestedition).
2. Thegassupplylineshouldbe1/2inch(1.27
cm)pipe.
3. Ifcodesallow,exiblemetaltubingmaybe
used to connect your dryer to the gas supply
line.ThetubingMUSTbeconstructedof
stainless steel or plastic-coated brass.
4. ThegassupplylineMUSThaveanindividual
shutoff valve.
5. A1/8inch(0.32cm)N.P.T.pluggedtapping,
accessiblefortestgaugeconnection,MUST
be installed immediately upstream of the gas
supply connection to the dryer.
6. ThedryerMUSTbedisconnectedfromthe
gas supply piping system during any pressure
testing of the gas supply piping system at test
pressuresinexcessof1/2psig(3.45kPa).
7. ThedryerMUSTbeisolatedfromthegassupply
piping system during any pressure testing of the
gas supply piping system at test pressures equal
toorlessthan1/2psig(3.45kPa).
8. Connections for the gas supply must comply
with the Standard for Connectors for Gas
Appliances,ANSIZ21.24.

6Installation Requirements
WARNING
FIREHAZARD
Exceedingthelengthofductpipeornumber
ofelbowsallowedinthe“MAXIMUMLENGTH”
charts can cause an accumulation of lint in the
exhaustsystem.Pluggingthesystemcould
create a fire hazard, as well as increase drying
times.
WARNING
FIREHAZARD
Aclothesdryermustbeexhaustedoutdoors.
Donotexhaustdryerintoachimney,awall,a
ceiling, an attic, a crawl space or any concealed
space of a building. A clothes dryer produces
combustiblelint.Ifthedryerisnotexhausted
outdoors,somenelintwillbeexpelledintothe
laundry area. An accumulation of lint in any area
of the home can create a health and fire hazard.
Thedryermustbeconnectedtoanexhaust
outdoors.Regularlyinspecttheoutdoorexhaust
opening and remove any accumulation of lint
aroundtheoutdoorexhaustopeningandinthe
surrounding area.
Install male fittings in correct direction:
Ininstallationswheretheexhaustsystemisnot
described in the charts, the following method
mustbeusedtodetermineiftheexhaustsystem
is acceptable:
Exhaust system requirements, continued
Number of 90° turns
MAXIMUMLENGTH
of4”(10.2cm)RigidMetalDuct
VENTHOODTYPE
(Preferred)
4”
(10.2cm) louvered
2.5”
(6.35cm)
0125ft.(38.10m) 110ft.(33.53m)
1115ft.(35.05m) 100ft.(30.48m)
2105ft.(32.00m) 90ft.(27.43m)
395ft.(28.96m) 80ft.(24.38m)
485ft.(25.91m) 70ft.(21.34m)
Number of 90° turns
MAXIMUMLENGTH
of4”(10.2cm)Semi-RigidMetalDuct
VENTHOODTYPE
(Preferred)
4”
(10.2cm) louvered
2.5”
(6.35cm)
060ft.(18.29m) 45ft.(13.72m)
150ft.(15.24m) 35ft.(10.67m)
240ft.(12.19m) 25ft.(7.62m)
3NOTRECOMMENDED
CORRECT INCORRECT
WARNING
FIREHAZARD
Donotallowcombustiblematerials(for•
example:clothing,draperies/curtains,paper)
tocomeincontactwithexhaustsystem.The
dryerMUSTNOTbeexhaustedintoachimney,
a wall, a ceiling, or any concealed space of a
building which can accumulate lint, resulting in
a fire hazard.
Donotscreentheexhaustendsofthevent•
system, or use any screws, rivets or other
fastenersthatextendintotheducttoassemble
theexhaustsystem.Lintcanbecomecaught
in the screen, on the screws or rivets, clogging
the duct work and creating a fire hazard as well
as increasing drying times. Use an approved
vent hood to terminate the duct outdoors, and
sealalljointswithducttape.Allmaleductpipe
ttingsMUSTbeinstalleddownstreamwiththe
flow of air.

7
Installation Requirements
WARNING
EXPLOSIONHAZARD
Do not install the dryer where gasoline or other
flammables are kept or stored. If the dryer is
installed in a garage, it must be a minimum of 18
inches(45.7cm)abovetheoor.Failuretodoso
canresultindeath,explosion,reorburns.
SeealsoCLEARANCEREQUIREMENTSonthe
nextpage.
Exhaustdirection
Directionalexhaustingcanbeaccomplishedby
installing a quick-turn 90° dryer vent elbow directly
toexhaustoutletofdryer.Dryerventelbowsare
available through your local parts distributor or
hardware store.
Exhaust system requirements, continued
1. Connect an inclined or digital manometer
betweenthedryerandthepointtheexhaust
connects to the dryer.
2. Set the dryer timer and temperature to air fluff
(cooldown)andstartthedryer.
3. Read the measurement on the manometer.
4. ThesystembackpressureMUSTNOTbe
higher than 1.0 inch of water column. If the
system back pressure is less than 1.0 inch of
water column, the system is acceptable. If the
manometer reading is higher than 1.0 inch of
water column, the system is too restrictive and
the installation is unacceptable.
Althoughverticalorientationoftheexhaustsystem
isacceptable,certainextenuatingcircumstances
could affect the performance of the dryer:
Only the rigid metal duct work should be used.•
Ventingverticallythrougharoofmayexpose•
theexhaustsystemtodowndraftscausingan
increase in vent restriction.
Runningtheexhaustsystemthroughan•
uninsulated area may cause condensation and
faster accumulation of lint.
Compressionorcrimpingoftheexhaustsystem•
will cause an increase in vent restriction.
Theexhaustsystemshouldbeinspectedand•
cleaned a minimum of every 18 months with
normal usage. The more the dryer is used,
themoreoftenyoushouldchecktheexhaust
system and vent hood for proper operation.
NOTE
Use of 90° quick-turn elbow required to meet
minimum installation depth.
Manufactured or mobile home installation
InstallationMUSTconformtocurrent1.
ManufacturedHomeConstruction&Safety
Standard,Title24CFR,Part32-80(formerlythe
FederalStandardforMobileHomeConstruction
andSafety,Title24,HUDPart280)orStandard
CAN/CSAZ240MH.
DryerMUSTbeexhaustedoutside(outdoors,not2.
beneaththemobilehome)usingmetalducting
thatwillnotsupportcombustion.Metalducting
mustbe4inches(10.16cm)indiameterwithno
obstructions. Rigid metal duct is preferred.
Ifdryerisexhaustedthroughtheoorand3.
area beneath the mobile home is enclosed,
theexhaustsystemMUSTterminateoutside
the enclosure with the termination securely
fastened to the mobile home structure.
Refer to previous sections in this guide for other 4.
importantexhaustventingsystemrequirements.
When installing a gas dryer into a mobile home, 5.
a provision must be made for outside make up
air. This provision is to be not less than twice
theareaofthedryerexhaustoutlet.
InstallerMUSTanchorthis(1)dryeror(2)dryer6.
mounted on pedestal to the floor with approved
MobileHomeInstallationKit-P/N137067200.

8
MINIMUMINSTALLATIONCLEARANCES-Inches(cm)
SIDES REAR TOP FRONT
Alcove 0”(0cm) 0”(0cm)* 0”(0cm) n/a
Under-
Counter 0”(0cm) 0”(0cm)* 0”(0cm) n/a
Closet 0”(0cm) 0”(0cm)* 0”(0cm) 1”(2.54cm)
Installation Requirements
Clearance requirements
60 sq. in.
(387.1cm²)
3”
(7.6cm)
60 sq. in.
(387.1cm²)
3”
(7.6cm)
0”
(0cm)
0”
(0cm)
1”
(2.54cm)
0”
(0cm)
IMPORTANT
DO NOT INSTALL YOUR DRYER:
1. Inanareaexposedtodrippingwateroroutside
weather conditions.
2. In an area where it will come in contact with
curtains, drapes, or anything that will obstruct
the flow of combustion and ventilation air.
3. Oncarpet.FloorMUSTbesolidwithamaximum
slopeof1inch(2.54cm).
INSTALLATION IN A RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom,
recessorcloset,MUSTbeexhaustedoutdoors.
2. No other fuel burning appliance shall be
installed in the same closet as the gas dryer.
3. Your dryer needs the space around it for proper
ventilation.
DO NOT install your dryer in a closet with a solid
door.
4. Closet door ventilation required: A minimum
of120squareinches(774.2cm²)ofopening,
equally divided at the top and bottom of the
door, is required. Openings should be located
3inches(7.6cm)frombottomandtopofdoor.
Openings are required to be unobstructed
when a door is installed. A louvered door with
equivalent air openings for the full length of the
door is acceptable.
closet door
NOTE
Toachieveaninstallationwith0”(0cm)clearance
forthebackofthedryer(forotherthanstraight
backventing),aquick-turn90°dryerventelbow
must be installed as described previously in this
manual.
F*
or other than straight back venting, a quick-turn 90°
dryerventelbowmustbeinstalledtoachieve0”(0cm)
installation.

9
Installation Requirements
38.00”
(96.5cm)
16.25”
(41.5cm)
18.25”
(46.5cm)
53.00”
(134.5cm)
1.4”
(3.5cm)
3.75”
(9.5cm) 13.50”
(34.5cm)
to center of rear vent
3.40”
(8.5cm)
gas supply
pipe on rear
of gas unit
50.6” (128.5cm)*
to clear open door 31.50” (80cm)*
to front of closed door
27.00”
(68.5cm)
centerline
height for
rear vent
electrical
supply on
rear of unit
freestand dryer
on floor
* T o obtain these minimal depth dimensions, dryer must either be vented straight back or
with a quick-turn 90° elbow. Connection of water inlet hose on Steam Models adds 3/4 in.
(2 cm) to installation depth. Upward venting of exhaust on pedestal-mounted or freestanding
dryer adds approximately 4 in. (10.2 cm) to installation depth. Downward venting of exhaust
on pedestal-mounted dryer adds approximately 1.7 in. (4.3 cm) to installation depth.
floor line
floor line
dryer mounted on
optional pedestal
75.75”
(192.5cm)
41.00”
(104cm)
39.00”
(99cm)
gas supply
pipe on rear
of gas unit
50.6” (128.5cm)*
to clear open door 31.50” (80cm)*
to front of closed door
centerline
height for
rear vent
electrical
supply on
rear of unit
* T o obtain these minimal depth dimensions, dryer must either be vented straight back or with a quick-turn 90° elbow.
Connection of water inlet hose on Steam Models adds 3/4 in. (2 cm) to installation depth. Upward or downward venting
of exhaust on stacked dryer adds approximately 4 in. (10.2 cm) to installation depth.
27.00”
(68.5cm)
Installed dryer dimensions

10 Installation Instructions
WARNING
ELECTRICALSHOCKHAZARD
ThisapplianceMUSTbeproperlygrounded.•
Electrical shock can result if the dryer is not
properly grounded. Follow the instructions in
this manual for proper grounding.
Donotuseanextensioncordwiththisdryer.•
Someextensioncordsarenotdesignedto
withstand the amounts of electrical current this
dryer utilizes and can melt, creating electrical
shock and/or fire hazard. Locate the dryer
within reach of the receptacle for the length
power cord to be purchased, allowing some
slack in the cord. Refer to the pre-installation
requirements in this manual for the proper
power cord to be purchased.
WARNING
ELECTRICALSHOCKHAZARD
Improper connection of the equipment grounding
conductor can result in a risk of electrical shock.
Check with a licensed electrician if you are in
doubt as to whether the appliance is properly
grounded.
The following are specific requirements for proper
and safe electrical installation of your dryer. Failure
to follow these instructions can create electrical
shock and/or a fire hazard.
Grounding requirements - Electric dryer (USA)
Electrical installation
NOTE
Dryers operating on 208 volt power supply will
have longer drying times than dryers operating
on 240 volt power supply.
For a grounded, cord-connected dryer:
1. ThedryerMUSTbegrounded.Intheeventof
a malfunction or breakdown, grounding will
reduce the risk of electrical shock by a path of
least resistance for electrical current.
2. After you purchase and install a 3 wire or 4
wire power supply cord having an equipment-
grounding conductor and a grounding plug
that matches you wiring system, the plug
MUSTbepluggedintoanappropriate,copper
wired receptacle that is properly installed and
grounded in accordance with all local codes and
ordinances. If in doubt, call a licensed electrician.
DO NOT modify the plug you’ve installed on this
appliance.
For a permanently connected dryer:
1. ThedryerMUSTbeconnectedtoagrounded
metal, permanent wiring system; or an
equipment grounding conductor must be run
with the circuit conductors and connected to
the equipment-grounding terminal or lead on
the appliance.
WARNING
ELECTRICALSHOCKHAZARD
A U.L.-approved strain relief must be installed •
onto power cord. If the strain relief is not
attached, the cord can be pulled out of the
dryer and can be cut by any movement of the
cord, resulting in electrical shock.
Do not use an aluminum wired receptacle with •
acopperwiredpowercordandplug(orvice
versa).Achemicalreactionoccursbetween
copper and aluminum and can cause electrical
shorts. The proper wiring and receptacle is a
copper wired power cord with a copper wired
receptacle.

11
Installation Instructions
WARNING
ELECTRICALSHOCKHAZARD
Improper connection of the equipment grounding
conductor can result in a risk of electrical shock.
Check with a licensed electrician if you are in
doubt as to whether the appliance is properly
grounded.
Grounding type
wall receptacle
Power cord with
3-prong grounded plug
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
Grounding requirements - Electric dryer (Canada)
Grounding requirements - Gas dryer (USA and Canada)
For a grounded, cord-connected dryer:
1. ThedryerMUSTbegrounded.Intheeventof
a malfunction or breakdown, grounding will
reduce the risk of electrical shock by a path of
least resistance for electrical current.
2. Since your dryer is equipped with a power
supply cord having an equipment-grounding
conductor and a grounding plug, the plug must
be plugged into an appropriate outlet that is
properly installed and grounded in accordance
with all local codes and ordinances. If in doubt,
call a licensed electrician.
DO NOT modify the plug provided with the
appliance.
1. The dryer is equipped with a three-prong
(grounding)plugforyourprotectionagainst
shock hazard and should be plugged
directly into a properly grounded three-prong
receptacle.
DO NOT cut or remove ground prong from the
plug.

12 Installation Instructions
Electrical connection (non-Canada) - 3 wire cord
Turn off power supply to outlet. 1.
Remove the screw securing the terminal block 2.
access cover in the lower corner on the back of
the dryer.
Install a UL-approved strain relief according 3.
to the power cord/strain relief manufacturer’s
instructions in the power cord entry hole below
the access panel. At this time, the strain relief
should be loosely in place.
ThreadanUNPLUGGED,UL-approved,30amp.4.
powercord,NEMA10-30typeSRDT,throughthe
strain relief.
Attachthepowercordneutral(centerwire)5.
conductor to the SILVER colored center
terminal on the terminal block. Tighten the
screw securely.
Attach the remaining two power cord outer 6.
conductorstotheouter,BRASScolored
terminals on the terminal block. Tighten both
screws securely.
WARNING
ELECTRICALSHOCKHAZARD
Do not make a sharp bend or crimp wiring/
conductor at connections.
3-wire receptacle
(NEMAtype10-30R)
Internal ground
(GREEN screw)
Install
UL-approved
strain relief here
Te rminal screw
recovery slot
Line 1
(BRASS terminal)
Neutral
(SILVER terminal)
Line 2
(BRASS terminal)
Access cover
screw
Te rminal
block
Neutral
(center wire)
30 AMP
NEMA 10-30
NOTE
If a terminal screw falls during cord installation,
it can be retrieved in the terminal screw recovery
slot below the access panel.
WARNING
ELECTRICALSHOCKHAZARD
Failure to disconnect power source before servicing
couldresultinpersonalinjuryorevendeath.
Follow manufacturer’s guidelines for firmly 7.
securing the strain relief and power cord.
Reinstall the terminal block cover.8.
DO NOT remove
internal ground in
a 3-wire system!!
Neutral
terminal
IMPORTANT
If moving dryer from a 4-wire system and
installing it in a 3-wire system, move the internal
ground from the center terminal back to the
GREENscrewnexttotheterminalblock.

13
4-wire receptacle
(NEMAtype14-30R)
Installation Instructions
Electrical connection (non-Canada) - 4 wire cord
Turn off power supply to outlet. 1.
Remove the screw securing the terminal block 2.
access cover in the lower corner on the back of
the dryer.
Install a UL-approved strain relief according 3.
to the power cord/strain relief manufacturer’s
instructions in the power cord entry hole below
the access panel. At this time, the strain relief
should be loosely in place.
ThreadanUNPLUGGED,UL-approved,304.
amp.powercord,NEMA14-30typeSTor
SRDT, through the strain relief.
Disconnecttheinternal(BLACK)dryerharness5.
groundwirefromthe(GREEN)groundscrew
nexttotheterminalblock.
Attachtheground(GREEN)powercordwire6.
tothecabinetwiththeground(GREEN)screw.
Tighten the screw securely.
Movetheinternaldryerharnessground7.
(BLACK)wiretotheterminalblockandattach
italongwiththeneutral(WHITE)powercord
wire conductor to the center, SILVER colored
terminal on the terminal block. Tighten the
screw securely.
AttachtheREDandBLACKpowercord8.
conductorstotheouter,BRASScolored
terminals on the terminal block. Tighten both
screws securely.
WARNING
ELECTRICALSHOCKHAZARD
Do not make a sharp bend or crimp wiring/
conductor at connections.
Internal ground
(GREEN screw)
Install
UL-approved
strain relief here
Te rminal screw
recovery slot
Line 1
(BRASS terminal)
Neutral
(SILVER terminal)
Line 2
(BRASS terminal)
Access cover
screw
Te rminal
block
Neutral
(WHITE wire)
30 AMP
NEMA 14-30
Ground
(GREEN wire)
NOTE
If a terminal screw falls during cord installation,
it can be retrieved in the terminal screw recovery
slot below the access panel.
WARNING
ELECTRICALSHOCKHAZARD
Failure to disconnect power source before servicing
couldresultinpersonalinjuryorevendeath.
Follow manufacturer’s guidelines for firmly 9.
securing the strain relief and power cord.
Reinstall the terminal block cover.10.
Move internal ground (BLACK)
wire to neutral (SILVER)
terminal for 4-wire system.
Neutral
terminal
GREEN
ground screw
BLACK or
RED power wire
BLACK
or RED
power wire
GREEN
ground wire
WHITE
neutral wire

14 Installation Instructions
Gas connection
Remove the shipping cap from gas pipe at the 1.
rear of the dryer.
IMPORTANT
The supply line must be equipped with an
approved manual shutoff valve. This valve
should be located in the same room as the dryer
and should be in a location that allows ease of
opening and closing. Do not block access to the
gas shutoff valve.
Connecta1/2inch(1.27cm)I.D.semi-rigidor2.
approved pipe from gas supply line to the 3/8
inch(0.96cm)pipelocatedonthebackofthe
dryer.Usea1/2inchto3/8inch(1.27cmto
0.96cm)reducerfortheconnection.Applyan
approved thread sealer that is resistant to the
corrosive action of liquefied gases on all pipe
connections.
Open the shutoff valve in the gas supply line to 3.
allow gas to flow through the pipe. Wait a few
minutes for gas to move through the gas line.
IMPORTANT
DONOTconnectthedryertoL.P.gasservice
withoutconvertingthegasvalve.AnL.P.
conversion kit must be installed by a qualified
gas technician.
WARNING
EXPLOSIONHAZARD
NEVER test for gas leaks with an open flame.
All connections must be wrench-tightened
Flare
Union
Flare
Union
GAS FLOW
Manual
Shuto
Valve
Closed
Open Flexible
Connector
Inlet Pipe on
Back of Dryer
elppiN
Shuto Valve -
Open position
to dryer
from gas supply
Check for gas system leaks with a manometer. 4.
If a manometer is not available, test all
connections by brushing on a soapy water
solution.

15
Water connection (Steam Model only)
Installation Instructions
Turn off COLD water supply to washer,1.
Remove COLD inlet hose from COLD water 2.
supply and inspect for rubber washer. Replace
washer if it is torn or worn out.
MomentarilyturnonCOLDsupplyandrun3.
some water into a bucket or container to clear
any contaminants in the line.
Remove hose kit from dryer drum and inspect 4.
hose couplings for proper placement of rubber
washers.
RUBBERWASHER
MUSTBEPRESENT
ANDUNDAMAGED
COLDINLETHOSE
TOWASHER
RUBBERWASHERS
MUSTBEPRESENT

16 Installation Instructions
Water connection, con’t (Steam Model only)
WATER INLET ON DRYER
DIRECT CONNECTION
OR WITH EXTENSION
COLD WATER SUPPLY
HOSE TO WASHER
If your installation has room for the COLD 1.
watersupplytoacceptthe“Y”connector
directly,threadthe“Y”connectortotheCOLD
water supply and snug it by hand; then tighten
it another 2/3 turn with pliers.
NOTE
Ifyouwereabletoinstallthe“Y”connectordirectly
to the COLD water supply, please skip to step 8.
Ifthereisnotroomtoinstallthe“Y”connector2.
directly,threadtheshortextensionhoseonto
the COLD water supply and snug it by hand;
then tighten it another 2/3 turn with pliers.
Threadthe“Y”connectortotheshort3.
extensionhoseandsnugitbyhand;then
tighten it another 2/3 turn with pliers.
Connect the COLD inlet hose for the washer 4.
tothe“Y”connectorandsnugitbyhand;then
tighten it another 2/3 turn with pliers.
Connect the straight end of the long hose from 5.
thekittotheotheroutletonthe“Y”connector
and snug it by hand. Connect the hose’s 90°
coupling to the brass water inlet on the back
of the dryer and snug it by hand. Tighten each
connection of the dryer inlet hose another 2/3
turn with pliers.
Turn on the water and check for leaks at all 6.
connections.

17
General installation
NOTE
A wiring diagram and technical data sheet are
located inside the dryer console.
Grounding type
wall receptacle
Power cord with
3-prong grounded plug
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
IMPORTANT
Besurethepowerisoffatacircuitbreaker/fuse
boxbeforepluggingthepowercordintoanoutlet.
Connecttheexhaustducttotheoutside1.
exhaustsystem(seepages5through7).Use
ofa4”(10.2cm)clampisrecommendedto
connectthedryertotheexhaustventsystem.
Usemetalfoiltapetosealallotherjoints.
Carefully slide the dryer to its final position. 2.
Adjustoneormoreofthelegsuntilthedryeris
restingsolidlyonallfourlegs.Placealevelon
topofthedryer.ThedryerMUSTbeleveland
resting solidly on all four legs. Rock alternating
corners to check for stability. Remove and
discard door tape.
Plugthepowercordintoagroundedoutlet.3.
Turn on the power at the circuit breaker/fuse 4.
box.
Read the 5. Use & Care Guide provided with
the dryer. It contains valuable and helpful
information that will save you time and money.
Seethenextpageaboutperformingabrief,6.
helpful“InstallationCycle”foryournewdryer.
If you have any questions during initial 7.
operation,pleasereviewthe“AvoidService
Checklist” in your Use & Care Guide before
calling for service.
Placetheseinstructionsinalocationnearthe8.
dryer for future reference.
Installation Instructions

18 Installation Instructions
Performing Installation Cycle
If your dryer has this console:
If your dryer has this console:
Empty the dryer drum.1.
After you plug in the dryer the first time: wake up the dryer by pressing any button, rotate cycle knob 2.
to touch up cycle, press the start button and then the cancel button.
Wake up the dryer again by pressing any button, then immediately and simultaneously press and hold 3.
both the sanitize and my favorite buttons for 5 seconds, or until the LCD display changes.
The LCD window will display 4. INSTAL CYCLEandshowestimatedtimeofcyclecompletion.Pressthe
startbutton.TheInstallationCyclewillautomaticallytestforcorrectcordconnection(onelectricmod-
els)andpresenceofgassupply(ongasmodels).Atcyclecompletion,theLCDwindowmaydisplay
INSTAL PASS!, meaning your new dryer is properly installed and ready for use. If it prompts an action
such as SERVICE CORD, NO GAS or call service 877 435 3287, review the installation steps and make the
necessary corrections before you attempt to use the dryer.
YourdryerwillexittheInstallationCycleandreturntonormaloperationthenexttimeyouwakeitup.5.
WARNING
FIREHAZARD
Beforeoperatingthedryer,makesurethedryer
area is clear and free of combustible materials,
gasoline, and other flammable vapors. Also
seethatnothing(suchasboxes,clothing,etc.)
obstructs the flow of combustion and ventilation air.
NOTE
On gas dryers, before the burner will light, it is
necessary for the gas line to be bled of air. If the
burner does not light within 45 seconds the first
time the dryer is turned on, the safety switch will
shut the burner off. If this happens, press cancel
and wait 5 minutes before making another
attempt to light.
After you plug in the dryer the first time: wake up the dryer by pressing any button and follow the 1.
prompts on the LCD User Interface, including language selection.
TheInstallationCyclewillautomaticallytestforcorrectcordconnection(onelectricmodels),pres-2.
enceofgassupply(ongasmodels)andfreeowofexhaustvent.Atcyclecompletion,theLCDuser
interface may display INSTAL PASS!, meaning your new dryer is properly installed and ready for use. If
it prompts an action such as SERVICE CORD, NO GAS or call service 877 435 3287, review the installation
steps and make the necessary corrections before you attempt to use the dryer.
YourdryerwillexittheInstallationCycleandreturntonormaloperationthenexttimeyouwakeitup.3.
NOTE
Dryer will stay awake for 3 minutes after the Installation Cycle. If you wish to
immediately run the dryer through a drying cycle, press the cancel button to put the
unit to sleep and then rewake it immediately to continue the normal operating mode.
NOTE
Dryer will stay awake for 3 minutes after the Installation Cycle. If you wish to
immediately run the dryer through a drying cycle, press the cancel button to put the
unit to sleep and then rewake it immediately to continue the normal operating mode.
Pleasereadthe6. Use & Care Guideandenjoyyournewpremiumdryer!
Pleasereadthe4. Use & Care Guideandenjoyyournewpremiumdryer!

19
Reversing Door
1 Besureyouhaveadequateswingareabeforereversingdoor.
2 You will need a screw driver with a #2 square bit.
3 Protectatworksurface,suchastopofdryeroroorneardryer,
with a soft cloth or towel.
4 Besuredryerisunpluggedfrompowersource!
WARNING
ELECTRICALSHOCKHAZARD
Failure to disconnect power source before servicing
couldresultinpersonalinjuryorevendeath.
A)RemovingTrimRing
1 Open door to 90 degree angle.
2 Remove and save trim plug and long,
course-thread, panhead screw.
3 Close door.
4 Rotatedoortrimapproximately¾”counter-
clockwise and pull ring away from door.
4 Gentlyplacedoorfacedownonat,covered
work surface.
3 While supporting door with the other hand,
remove 3 short, fine-thread, counter-sunk
screws.
B)RemovingDoorfromFrontPanel
1 Reopen door to 90 degree angle.
2 Remove 2 short, course-thread, panhead
screws.
Preparing to reverse door swing
Removing door and hardware
Screwdrivers with
#2 square &
straight bit
Tools needed:

20 Reversing Door
C)ReversingHardwareonFrontPanel
1 Remove 2 short, course-thread, panhead
screws from striker and 2 plastic hole plugs.
2 Rotate striker and move to opposite
opening. Attach with 2 short, course-thread,
panhead screws.
3 Install original plastic hole plugs or use new
plugs supplied with dryer.
D)RemovingDoorHardware
1 Remove 2 long, course-thread, counter-sunk
screws and latch plate. Set latch aside.
2 Remove 4 long, course-thread, recessed
screws and hinge. Set hinge aside.
Reversing door

21
Reversing Door
E)RemovingLatchIndicator F)RemovingHolePlug
1 Insert flat blade screwdriver into open slot of
latch indicator.
2 Gentlypryupwardtoreleasetab.
3 Pulltheindicatoroutandsetitaside.
3 Pulltheholeplugoutandsetitaside.
1 Insert flat blade screwdriver into open slot of
hole plug.
2 Gentlypryupwardtoreleasetab.

22 Reversing Door
G)ReinsertingLatchIndicator
1 Rotate the latch indicator and move it to the
opposite hole in the door.
insert indicator
through slot
insert tab
insert tab
press down
and snap
3 Firmly press downward on the indicator until
the tab snaps in place.
2 Firmly insert the two small tabs on either
side of the latch indicator into the two slots
on either side of the hole in the door.
insert tab
insert tab
press down
and snap
H)ReinsertingHolePlug
1 Rotate the hole plug and move it to the
opposite hole in the door.
2 Firmly insert the two small tabs on either
side of the hole plug into the two slots on
either side of the hole in the door.
3 Firmly press downward on the hole plug until
the tab snaps in place.

23
Reversing Door
I)ReattachingLatchPlate
1 Rotate latch plate and move to opposite side
of door above indicator.
2 Reattach with 2 long, course-thread,
counter-sunk screws.
J)ReattachingHinge
1 Rotate hinge and move to opposite side of
door above hole plug.
2 Reattach with 4 long, course-thread,
counter-sunk screws.
K)ReattachingDoortoFrontPanel
1 Use side locating pins to align hinge and
install 1 short, fine-thread, counter-sunk
screw in center hole of hinge side.
2 Install other 2 short, fine-thread, counter-
sunk screws in upper and lower holes of
hinge side.
3 Install 2 short, course-thread, panhead
screws through face of hinge plate.
4 Close door and test operation of latch.

24
3 Rotate and move trim ring cover plate to
opposite opening in trim and reinsert.
M)ReinstallingTrimRing
1 Close door.
2 Orienttrimso12positionisapproximately
¾”totheleftoftopcenter.Openinginring
should be on the hinge side.
3 Insert trim ring in slots and rotate clockwise
approximately¾”.
N)ReinstallingTrimPlug
1 Open door to 90 degree angle.
2 Install trim plug with 1 long, course-thread,
panhead screw.
O)Plugindryerandcontinueoperation.
Reversing Door
L)ReversingTrimRing
1 Trim ring orientation is marked on the back.
2 Remove trim ring cover plate. To remove
plate from left, pivot point is down. To
remove plate from right, pivot point is up.
UP

25
Options
Replacement parts: 1-877-4ELECTROLUX (1-877-435-3287)
If replacements parts are needed for your dryer,
contact the source where you purchased your
dryer,call1-877-4ELECTROLUX(1-877-435-3287),
orvisitourwebsite,www.electroluxappliances.
com,fortheElectroluxAuthorizedPartsDistributor
nearest you.
CAUTION
Failuretouseaccessoriesmanufacturedby(or
approvedby)themanufacturercouldresultin
personalinjury,propertydamageordamageto
the dryer.
WARNING
ELECTRICALHAZARD
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify proper
operation after servicing.
Accesories
26.44”
(67.16cm)
15.00”
(38.10cm)
27.00”
(68.58cm)
MATCHING STORAGE PEDESTAL
IslandWhitePedestal-P/NEPWD15IW
MediterraneanBlue-P/NEPWD15MB
SilverSandsPedestal-P/NEPWD15SS
TurquoiseSkyPedestal-P/NEPWD15TS
A storage pedestal accessory, specifically
designed for this dryer may be used to elevate the
dryer for ease of use. This pedestal will add about
15”(38.1cm)totheheightofyourunitforatotal
heightof53”(134.62cm).
DRYER STACKING KIT
P/N134700400
A kit for stacking this dryer on top of matching
washer came with the initial purchase of this dryer.
If you desire another stacking kit, you may order
one.
LP CONVERSION KIT
P/N134709300
Gasdryersintendedforuseinalocationsupplied
withLPmustuseaconversionkitpriorto
installation.
MOBILE HOME INSTALLATION KIT
P/N137067200
Installations in mobile homes require use of
MOBILEHOMEINSTALLATIONKIT.
DRYING RACK
P/N134912700
Anexpandabledryingrackcamewiththeinitial
purchase of this dryer. If you desire another drying
rack, you may order one.
UNIVERSAL APPLIANCE WRENCH
P/N137019200
The matching washer to this dryer was supplied
withaUNIVERSALAPPLIANCEWRENCH.Ifyou
desire another wrench, you may order one.

26 Notes