 www.elpas.com Page 1 of 3 DE6321_V4_09/13   VisAccess RDK-4 Proximity Reader with Keypad  Installation Guide 1. INTRODUCTION The  RDK-4  is  a  proximity  reader  with keypad,  compatible  with  the  AXS-100 access control system.  The system is designed to limit access to  restricted  areas,  while  permitting authorized people to enter. The RDK-4 can  be programmed by the  installer  to offer  one  of  three  security  levels  for opening the door: 1. Valid tag only. 2. Valid  tag  and  user  PIN  (Personal Identification Number) code. 3. Password only.  Figure 1 - RDK-4 It  is  recommended  to  install  the  RDK-4  on  a  wall  outside  the protected area, and the AXS-100 control unit inside the protected area. Proximity access cards or tags are  used as  keys to open doors. When presented to an RDK-4, the access card or tag emit a coded RF signal that is read by the proximity reader. The reader prompts the user for a 4-digit PIN code (applicable to security level 2). When the correct PIN code is typed, the control unit verifies that the card is valid and makes the decision as to whether it should energize an output relay that releases the lock. All activity involving the proximity readers is recorded and logged by the AXS-100. For information about the AXS-100 system, refer to the AXS-100 user’s guide and installation instructions.   2. SPECIFICATIONS Power input: 12-16V DC From the AXS-100 Buttons: 12 (numeric keypad) Frequency: 125 kHz Tag reading range: 50 - 100 mm (2 - 4 in.) Tag codes possibilities: 1012 possible combinations. Cable (to AXS-100 control unit) maximum length:  100 m (320 ft)Minimum distance between readers: 60 cm (2 ft) Weight: 170 g (6 oz) Color: Metallic brown Dimensions (L x W x D): 122 x 82 x 31 mm  (4 - 13/16 x 3 - 1/2 x 1 - 1/4 in.)  Operating temperature: -20°C to 50°C (-4°F to 122°F)    3. MOUNTING Mount the proximity reader outside the door on the wall or door frame. The RDK-4 comes with a 1m (3 ft) cable. Note:  When  installing  more  than  one  RDK-4,  the  distance between the readers should be at least 60 cm (2 ft.), to ensure proper operation.  To mount the proximity reader: A. Remove the case closure screw.  B. Separate the base from the keypad assembly. C. Place the base on the installation surface, mark points, drill the holes and insert plastic anchors, if necessary. D. Fit the base into the rubber gasket and use the 2 mounting screws  to  attach  the  base  and  gasket  to  the  selected surface.    Figure 2 - Base and Gasket  4. WIRING Each  RDK-4  reader  is  connected  to  the  control  unit  via  a four-wire cable. The standard cable is color-coded. Use a cable with the same colors to avoid mistakes in connection.   Connect each  proximity  reader  to  the  reader  sections  on  the  AXS-100 connector blocks. See diagram for color-coding.  PWRGNDTXRXREADER 1/2RedBlackGreenWhiteAXS-100AXS-100XTRDK-4 Figure 3 - Connection to AXS-100
VisAccess RDK-4– Installation Guide    www.elpas.com Page 2 of 3 DE6321_V4_09/13  5. SECURITY LEVEL SELECTION The RDK-4 can be programmed by the installer to offer one of three security levels, as shown in the next table. No. Security level description Security level selection 1 The door is unlocked by presentation of a valid tag/card only. No jumper is not installed . 2 Door is unlocked by presentation of a valid tag/card followed by user PIN code keying. Select this security level by either of the following actions: A.  Install jumper in the RDK-4. B.  Connect shorting wire between D.POS & GND terminals in the RDK-4 (see fig. 4). C.  Set To/From time in minutes, in AXS-100 registers 8 & 9 (for Reader 1) or registers 10 & 11 (for Reader 2), to determine the period during which the RDK-4 will switch from security level 1 (tag only) to security level 2 (tag + PIN). For example, if you want that the security level 2 will be valid from 12 o’clock (720 min.) to 13 o’clock (780 min.), set AXS-100 register 8 to 720 and register 9 to 780. For details, refer to AXS-100 User Guide par. 3.2.7. 3 Door is unlocked by Password keying followed by pressing the # key Set AXS-100 password as described in the AXS-100 User Guide par. 3.3.3.        Figure 4  Selecting Security Level 2 by Using a Jumper externalreaderJumper RDK-4   6. USING THE RDK 4 To enroll an access card refer to the AXS-100 User Manual section 3.3.1 Add Keys. The PIN code of each card is automatically defined by the AXS-100. In order to receive the PIN codes for access cards, please refer to the AXS-100 User Manual section 5.2.1 Setup Flags. To enter a door, present a valid tag to the RDK-4. If your RDK-4 is programmed to operate by tag and user’s PIN code, present the tag and then enter the PIN code within 5 seconds.  When presented to an RDK-4, the access card or tag emits a coded RF signal  that  is  read by the proximity reader. The reader prompts the user for a 4-digit PIN code by blinking the yellow light. If no PIN code is typed within 10 seconds, or a wrong PIN code is typed, the red LED will light up. A  delay  of  more  than  5  seconds,  between  presenting  a  tag  and starting to key user PIN code, or between any two digits, cancels the operation. The  normal  functions  of  the LEDs  are  summarized  in  the following table. LED Function Green  Indicates  that  a  valid  tag  was  presented  and the output relay was activated. Red     Indicates that an invalid tag  was presented or an invalid PIN was entered. Yellow Remains  lit  to  indicate  that  power  is  on.  In security  level  2,  blinks  after  the  tag  is accepted, to prompt the user for PIN. Job Control There  is  an  option  that  when  a  valid  exit  occurs,  the  exit  will  be reported (Time  &  Attendance  exit),  if  the  reader is  defined  in  EXIT mode (see AXS-100 user guide, section 4). To implement this option, ther are 2 possibilities: 1.  Before opening the door, press the “” key in the RDK-4. 2.  Before opening the door, press the RTE switch (see fig. 5).  Figure 5  RTE switch externalreaderRTEswitch RDK-4   7. REGULATORY 7.1 EU Declaration of Conformity This equipment is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. 7.2 Compliance FCC Compliance This device (FCC #:O4X3-63210) complies with FCC Rules Part 15. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)  This  device  must  accept  any  interference  received,  or  that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC  Rules.  These  limits  are  designed  to  provide  reasonable protection  against  harmful  interface  in  a  residential  installation. This equipment generates; uses and can radiate radio frequency energy  and,  if  not  installed  and  used  in  accordance  with  the instructions,  may  cause  harmful  interference  to  radio communications However, there is no guarantee that interference will not occur in a particular  installation.  If  this  equipment  does  cause  harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: •  Reorient or relocate the receiving antenna. •  Increase the separation between the equipment and receiver. •  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. •  Consult the dealer or an experienced radio/TV technician for help. Changes or modifications to this equipment not expressly approved by the party responsible for compliance (Elpas Solutions Ltd.) could void the user’s authority to operate the equipment. 7.3 Company Contact Elpas, Inc. Westford, Massachusetts (USA) -Tel: 1-800-223-0020
VisAccess RDR-PXT Reader– Installation Guide   Page 3 of 3 DE6321_V4_09/13  W.E.E.E. Product Recycling Declaration For  information regarding the recycling  of this product  you must contact the  company from which you orignially purchased it. If you are discarding this product and not returning it for repair then you must ensure that it is returned as identified by your supplier. This product is not to be thrown away with everyday waste - Directive 2002/96/EC Waste Electrical and Electronic Equipment.    8. PRODUCT WARRANTY  Elpas Solutions Ltd. (Elpas or the Company), and its affiliates, warrants its products (hereinafter referred to as "the Product”) to be free of defects in materials and workmanship under normal operating conditions and use for a period of one year from the date of shipment by Elpas. The Company’s obligations shall be limited within the warranty period, at its option, to repair or to replace the defective Product or any defective component or part thereof. To exercise this warranty, the product must be returned to the manufacturer freight prepaid and insured. This warranty does not apply to repairs or replacement caused by improper installation, Product misuse, failure to follow installation or operating instructions, alteration, abuse, accident, tampering, repair by anyone other than Elpas, external causes, and failure to perform required preventive maintenance. This warranty also does not apply to any products, accessories, or attachments used in conjunction with  the  Product,  including batteries,  which  shall be  covered  solely by  their own warranties,  if  any. Elpas  shall  not be  liable for  any damage or  loss whatsoever, whether directly, indirectly, incidentally, consequentially or otherwise, resulting from a malfunction of the Product due to products, accessories, or attachments of others, including batteries, used in conjunction with the Product. Elpas  MAKES  NO  EXPRESS  WARRANTIES  EXCEPT  THOSE  STATED  IN  THIS  STATEMENT.  ELPAS  DISCLAIMS  ALL  OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. ELPAS’S SOLE RESPONSIBILITY FOR WARRANTY CLAIMS IS LIMITED TO REPAIR OR TO REPLACE AS SET FORTH IN THIS STATEMENT. Elpas  shall  have  no  liability  for  any  death,  personal  injury,  property  damage,  or  other  loss  whether  direct,  indirect,  incidental, consequential, or otherwise, based on a claim that the Product failed to function. However, if Elpas is held liable, whether  directly or indirectly, for any loss or damage arising under this limited warranty or otherwise, regardless of cause or origin, the company's maximum liability shall be limited to the purchase price of the Product, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive liability of Elpas. Elpas shall not, under any circumstances whatsoever, be liable for any inaccuracy, error of judgment, default, or negligence of Elpas, its employees, officers, agents, or any other party, or of the purchaser or user, arising from any assistance or communication of any kind regarding the configuration, design, installation, or creation of security system involving the Product, that being the responsibility of the purchaser or user. If Elpas is unable to make such repair or replacement, the company’s entire liability shall be limited to the cost of a reasonable substitute product. Elpas shall not be responsible for any dismantling, installation,  reinstallation, purchasing, shipping, insurance, or any similar charges  Elpas  shall  have  no  liability  for  any  damages,  including  without  limitation,  any  direct,  indirect,  incidental,  special,  or consequential damages, expenses, costs, profits, lost savings or earnings, or other damages arising out of the use of the Product or the removal, installation, reinstallation,  repair or  replacement  of  the  Product or  any related events.  In  the  event that there is any liability against Elpas, such liability shall be limited to the purchase price of the Product which amount shall be fixed as liquidated damages. The purchaser and user understand that this Product may be compromised or circumvented by intentional acts; that the Product will not in all cases prevent death, personal injury, property damage, or other loss resulting from burglary, robbery, fire or other causes; and that the Product will not in all cases provide adequate warning or protection. The purchaser and user also understand that a properly installed and maintained alarm may reduce the risk of  events such as burglary, robbery, and fire without warning, but it is not insurance or a guarantee that such events will not occur or that there will be no death, personal injury, property damage, or other loss as a result of such events. By purchasing the Product, the purchaser and user shall defend, indemnify and hold Elpas, its officers, directors, affiliates, subsidiaries, agents, servants, employees, and authorized representatives harmless from and against any and all claims, suits, costs, damages, and judgments incurred, claimed, or sustained whether for death, personal injury, property damage, or otherwise, because of or in any way related to the configuration, design, installation, or creation of a security system involving the Product, and the use, sale, distribution, and installation of the Product, including payment of any and all attorney’s fees, costs, and expenses incurred as a result of any such events. The purchaser or user should follow the Product installation and operation instructions and test the Product and the entire system at least once  each  week.  For  various  reasons,  including  but  not  limited  to  changes  in  environmental  conditions,  electric,  electronic,  or electromagnetic disruptions, and tampering, the Product may not perform as expected. The purchaser and user are advised to take all necessary precautions for the protection and safety of persons and property. This statement provides certain legal rights. Other rights may vary  by  state  or  country.  Under  certain  circumstances,  some  states  or  countries  may  not  allow  exclusion  or  limitation  of  incidental  or consequential damages or implied warranties, so the above exclusions may not apply under those circumstances and in those states or countries. Elpas reserves the right to modify this statement at any time, in its sole discretion without notice to any purchaser or user. However, this statement shall not be modified or varied except by Elpas in writing, and Elpas does not authorize any single individual to act on its behalf to modify or vary this statement. Any questions about this statement should be directed to Elpas.

Navigation menu