Elster Solutions EA2W-I Water Meter Spread Spectrum transmitter User Manual final version
Elster Solutions, LLC Water Meter Spread Spectrum transmitter final version
Contents
- 1. final version - User manual
- 2. User Manual
final version - User manual
September 2010 IL42-5016A EA_Water 2.0 module Installation instructions General This leaflet contains instructions for Elster’s EA_Water 2.0 module for use on water meters to provide readings to the EnergyAxis® System. For proper installation and maximum life of the modules, use the following procedures. Familiarize yourself with the location and identification of the terminals on your water meter registers before any installation procedure. Connection instructions The EA_Water 2.0 module register connections are as follows: Function Data Power (or power/clock) Common Register terminal color Module cable color Elster AMCO Badger Sensus Hersey Neptune Black Red Green Green Green Red Red Green Red Red Red Black Green Black Black Black Black Green Installation instructions Integral mount The EA_Water 2.0 module is shipped fully assembled and ready to install. You will need to mount the EA_Water 2.0 module directly onto the water meter register. The integral mount cover has a hoop that fits around the water meter register. Int egral mount cover EA_Wat er 2. 0 remot e module 1. Align the hoop EA_Water 2.0 module over the water meter register so that the EA_Water 2.0 module wires are able to connect to the water meter terminals. 2. Securely attach the EA_Water 2.0 module over the water meter register. IL42-5016A 3. September 2010 Using the table in “Connection instructions” on page 1, connect the appropriate wires to the correct terminals on the water meter register. Typically, the connection is made by placing the wire under the screw terminal and tightening down securely. See the product documentation for your water meter register for more information. Wall mount The EA_Water 2.0 module can be mounted on a wall close to the water meter. To assist placing the enclosure on the hanging screw, the enclosure has hash marks that will help you properly align the module. The cable from the EA_Water 2.0 module and the water meter register should not exceed 100 feet (30 meters). 1. Remove the remote mount cover from the EA_Water 2.0 module. 2. Splice the cables from the EA_Water 2.0 module to the water meter register cable using weatherproof gel caps (for example, 3M style 314 IDC). 3. Insert the cable back into the EA_Water 2.0 module, making sure to provide strain relief for the cable. 4. Reattach the remote mount cover to the EA_Water 2.0 module. 5. Hang the EA_Water 2.0 module on the hanger screw, making sure it is level. 6. Screw 2 screws into the 2 bottom supporting screw mounts. 7. Using the table in “Connection instructions” on page 1, connect the appropriate wires to the correct terminals on the water meter register. Typically, the connection is made by placing the wire under the screw terminal and tightening down securely. See the product documentation for your water meter register for more information. 8. When you have completed the installation, secure the EA_Water 2.0 enclosure by inserting the tamper plugs into bottom supporting screw mounts. Tamper plugs Hanger screw Support ing screws September 2010 IL42-5016A Pipe mount The EA_Water 2.0 module can be mounted on a pipe close to the water meter. The pipe mounting option uses a hose clamp and mounting bracket to attach the EA_Water 2.0 module to a pipe. The cable from the EA_Water 2.0 module to the water meter register should not exceed 100 feet (30 meters). 1. Remove the remote mount cover from the EA_Water 2.0 module. 2. Align the mounting bracket to the remote mount cover and secure the mounting bracket with screws. 3. Splice the cables from the EA_Water 2.0 module to the water meter register cable using weatherproof gel caps (for example, 3M style 314 IDC). 4. Insert the cable back into the EA_Water 2.0 module, making sure to provide strain relief for the cable. 5. Reattach the remote mount cover to the EA_Water 2.0 module. 6. Thread the pipe hose clamp through the slot of the mounting bracket 7. Mount and secure the EA_Water 2.0 module to the pipe. 8. Using the table in “Connection instructions” on page 1, connect the appropriate wires to the correct terminals on the water meter register. Typically, the connection is made by placing the wire under the screw terminal and tightening down securely. See the product documentation for your water meter register for more information. 9. When you have completed the installation, secure the EA_Water 2.0 enclosure by inserting the tamper plugs into tamper plug mounts.. Tamper plugs Hose clamp Mount ing bracket Tamper plugs IL42-5016A September 2010 FCC and Industry Canada Compliance User Information (Part 15.105): This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, the user is encouraged to try to correct the interference by one or more of the following measures: • reorient or relocate the receiving antenna • increase the separation between the equipment and the receiver • connect the equipment into an outlet on a circuit different from that to which the receiver is connected • consult the dealer or an experienced radio/TV technician for help If you experience trouble with this equipment, please use the Return Material Request (RMR) feature available at the Online Customer Services at www.elstersolutions.com. Do not attempt to repair this equipment itself unless you are replacing the entire module. Compliance Statement (Part 15.19): This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: 1) This device may not cause harmful interference, and 2) This device must accept any interference received, including interference that may cause undesired operation. Warning (Part 15.21): Changes or modifications not expressly approved by Elster could void the user's authority to operate the equipment. RF Radiation Safety Guidelines per Part 2 of FCC Rules and Regulations: The meter should be installed in a location where there will be a separation greater than 20 cm from locations occupied by humans. Industry Canada Statement: The term “IC” before the certification/registration number only signifies that the Industry Canada technical specifications were met. Collocation Statement: Collocation of simultaneously-transmitting (co-transmitting) antennas within 20 cm of each other in a final product is not allowed. DISCLAIMER OF WARRANTIES AND LIMITATIONS OF LIABILITY There are no understandings, agreements, representations, or warranties either express or implied, including warranties of merchantability or fitness for a particular purpose, other than those specifically set out by any existing contract between the parties. Any such contract states the entire obligation of the seller. The contents of this document shall not become part of or modify any prior existing agreement, commitment, or relationship. The information, recommendations, descriptions, and safety notices in this document are based on Elster experience and judgment with respect to operation and maintenance of the described product. This information should not be considered as all-inclusive or covering all contingencies. If further information is required, Elster should be consulted. No warranties, either expressed or implied, including warranties of fitness for a particular purpose or merchantability, or warranties arising from the course of dealing or usage of trade, are made regarding the information, recommendations, descriptions, warnings, and cautions contained herein. In no event will Elster be responsible to the user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental, or consequential damage or loss whatsoever, including but not limited to: damage or loss of use of equipment, cost of capital, loss of profits or revenues, or claims against the user by its customers resulting from the use of the information, recommendations, descriptions, and safety notices contained herein. Elster Raleigh, North Carolina USA *IL42-5016A* © 2010 by Elster All rights reserved. Printed in the United States.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Encryption : Standard V4.4 (128-bit) User Access : Print, Copy, Extract, Print high-res Has XFA : No Page Count : 4EXIF Metadata provided by EXIF.tools