Product Data Document 420DS-12A October 1, 2007 - Page 1 Integrated Pump Control SCADA RTU Pre-Engineered Water and Wastewater Remote Pump Control Application Package Single program offers performance and simplicity for monitoring and control of remote water and wastewater applications • Well station • Remote tank level control • Reservoir Control • Duplex Lift or Booster station • Triplex Lift or Booster station This standard pre-programmed application leverages our decades of experience monitoring and controlling remote pumps in a wide variety of water and wastewater sites in North America and throughout the world. The standard application can be used with the appropriate Bristol® ControlWave® PLC/RTU, from Emerson Process Management to meet the I/O requirements at the various sites. The combined solution offers a cost effective system that is ready to deploy without the typical programming overhead. Remote Automation Solutions Website: www.EmersonProcess.com/Remote Benefits • Pre-programmed package eliminates the need for custom programming • One package for one to three pumps provides consistency for operators and technicians • Local Display/Keypad Operator Interface panel for on-site system control • Alarm and historical data reporting for full SCADA integration • Multiple pump scenarios allow flexibility to meet a wide range of applications • Pump start/stop as well as VFD speed control • Easy-to-use web page station configuration and setup • Easily interfaces to field devices and sensors • Security and water quality functions can be easily added as needed Plant managers will take maximum advantage of the flexibility and maintenance personnel will appreciate the simplicity of the Bristol ControlWave pump control application. All remote water and wastewater applications have the same requirements to automatically control one or more pumps to maintain level, pressure and/or flow. Some sites may also have the need to control chemical feed, measure rain level, and detect intrusion events. All of these are pre-programmed and available for use to customize for the specific site. When the application requires modifications or additions to the standard program, Bristol ControlWave Designer allows unlimited customization by your engineering staff or other integrators. Product Data Document 420DS-12A October 1, 2007 - Page 2 Specifications Integrated Pump Control SCADA RTU Well or Reservoir Analog outputs: VFD speed control Chemical feed pump Digital inputs: Pump 1 status Pump Remote/Local Counter inputs: Station flow Rain gauge Digital outputs: Pump start Pump Stop Triplex Booster or Lift Station Analog inputs: Station flow Well drawdown ControlWave ExpressPAC Outlet pressure SCADA Package Chlorine residual Clearwell level or tank level Analog outputs: VFD speed control Chemical feed pump Counter inputs: Station flow Rain gauge Duplex Booster or Lift Station Digital inputs: Pump 1 & 2 status Pump 1 & 2 Remote/Local 2 tank level DI Intrusion or Motion Digital outputs: Pump 1 & 2 start Pump 1 & 2 Stop Analog inputs: Station flow ControlWave MIcro Inlet pressure PLC/RTU Outlet pressure Chlorine residual Clearwell level or tank level Remote Automation Solutions Website: www.EmersonProcess.com/Remote Digital inputs: Pump 1, 2 & 3 status Pump 1, 2 & 3 Remote/Local 2 tank level DI Intrusion or Motion Digital outputs: Pump 1, 2 & 3 start Pump 1, 2 & 3 Stop Analog inputs: Station flow Inlet pressure ControlWave MIcro Outlet pressure PLC/RTU SCADA Package Chlorine residual Clearwell level or tank level Analog outputs: VFD speed control Chemical feed pump Counter inputs: Station flow Rain gauge Product Data Document 420DS-12A October 1, 2007 - Page 3 Integrated Pump Control SCADA RTU SCADA Packages Historical Archive The Bristol ControlWave Micro and ControlWave ExpressPAC integrated SCADA packages, from Emerson, are designed and built for out-of-the-box installation and startup. The assemblies are fully integrated units that combine the PLC/RTU with a variety of options commonly required in SCADA applications. These include a NEMA 4X rated enclosure, power supply and battery backup options, termination options, display and operator input options, and wireless communication options. Historical data is stored in three archive files in the ControlWave PLC/RTU flash memory. This ensures maximum data integrity even in the event of a SCADA communication network failure. The historical data archives may be collected periodically on a scheduled or demand basis by the OpenBSI Harvester utility. This technique also minimizes communication bandwidth requirements significantly benefiting radio and cellular network architectures. Daily Archive: Stores 35 days of time-stamped minimums, maximums, averages and totals Hourly Archive: Stores hourly time-stamped minimums, maximums, averages and totals Trend Archive: The Trend Archive stores instantaneous values at a fixed period from one minute to sixty minutes. ControlWave MIcro PLC/RTU SCADA Package The ControlWave SCADA packages with the preprogrammed pump controller application are ideal for integrating remote site measurement and control into the SCADA system. Station Control Strategies: Setup and Configuration As mentioned earlier, the ControlWave pump control SCADA application is pre-programmed. The unit only needs site specific configuration through the easy-to-use set of web pages supplied with the application software. These configuration web pages are accessible through the OpenBSI TechView utility. Level control Pressure control Time control Pump lead/lag and pump alteration Pump interlock and permissive conditions Manual and PID VFD Control Remote Automation Solutions Website: www.EmersonProcess.com/Remote TechView allows easy connection to any ControlWave PLC/RTU through serial or Ethernet ports. The utility is essentially a web page browser that really simplifies menu navigation and PLC/RTU configuration. Product Data Document 420DS-12A October 1, 2007 - Page 4 Integrated Pump Control SCADA RTU The initial configuration setup is presented in a stepby-step procedure using a question and answer format. Once familiar with the procedures, individual configuration pages can easily be accessed rather than using the Q & A format. I/O Configuration Q & A Configuration Configuration Page Loop Control Page The configuration pages allow you to set the communication address and parameters, select station control mode parameters, enter setpoints and alarm limits, modify zero and span for analog inputs, add permissives and interlocks, and perform pump startups. A station overview display is also provided to show pump run status, local/remote operation, and instantaneous values of pressure, flow and level. Remote Automation Solutions Website: www.EmersonProcess.com/Remote Setup and configuration may also be performed from the integral display/keypad on the ControlWave PLC/RTU SCADA package or via the SCADA system host HMI. All configuration parameters are made available to OPC servers for compatibility with our OpenEnterprise SCADA software as well as third party SCADA software packages. Integrated Pump Control SCADA RTU Product Data Document 420DS-12A October 1, 2007 - Page 5 KPSI™ Submersible Level Transducers • Tank and wet well level measurement • 5 to 700 feet • .05% to 1 % full scale accuracy • Non-fouling diaphragm options for lift station applications • 4-20 mA or 0-5 V output AquaSensors™ Water Quality Instruments Software components The ControlWave pump control application is available pre-installed in a ControlWave Micro or Express PLC/RTU. A modifiable version is available allowing program additions, but does not allow modifications to the pump control program itself. There is also a complete source version that allows unlimited modification of the pump control program. These three offerings provide the flexibility to meet the needs of wide range of users, technicians and engineers. The AquaSensors DataStick™ provides a cost-effective plug and play analytical measurement system for continuous use in industrial environments. DataStick communicates with ControlWave via a preconfigured serial Modbus function block. • Direct measurement of pH, reagent free residual chlorine, dissolved oxygen, ORP or turbidity • 11” CPVC direct insertion probe • 10-30 Vdc, <200 mW Censar® Six-Cense® multiparameter in-line sensor measures in real time (pH, ORP, conductivity, dissolved oxygen, free chlorine, and temperature) Products for expanded functionality • Direct insertion into pressurized main 2 inches to 72 inches in diameter The pump control SCADA package can be combined with a variety of additional products that facilitate integration or provide even greater functionality. • Operates under working pressures up to 230 psi • Reagent-free measurement of Chlorine • Measures Monochloramine for plans using chloramination • Low maintenance, low cost sensor replacement Process Measurement Transmitters Bristol 2808 & 3808 • 2808 analog pressure transmitter for tank level measurement • 3808 digital DP transmitter for flow measurement • Adjustable ranges • High accuracy • Two year warranty • Local indicator option Remote Automation Solutions Website: www.EmersonProcess.com/Remote Security Vision application package • Pre and post event video capture and replay • Pre-programmed function block provides all video file/folder manipulation • OpenBSI Utility for collection and replay of captured events • IP enabled network video camera with FTP server • Facility entry access control and reporting Integrated Pump Control SCADA RTU Product Data Document 420DS-12A October 1, 2007 - Page 6 OpenEnterprise SCADA Host The OpenEnterprise SCADA software provides a turnkey SCADA solution from field equipment to Supervisory Control, Management Reporting and Enterprise wide data distribution. OpenEnterprise is the tool that links Projects, Operations, Accounts and Management, making SCADA a part of the business process. • Real-time Relational Object Oriented Database • Included Historian with backfill capability • Advanced ‘state of the art’ graphics builder • Powerful reporting tools • Alarm and Event Manager • Open standards support for SQL, ODBC/ADO, Java DBC, OPC OLE & HDA, DDE, VB • Thin client options for corporate and operational users • OPC data access direct from database • Fault tolerant and distributed servers over WAN or LAN Related specification documents: ControlWave Micro – 420ds5k.pdf ControlWave ExpressPAC - 420ds7c.pdf ControlWave Micro Enclosures – 420ds0d.pdf ControlWave Designer – 420ds3d.pdf Security Vision – 454ds11b.pdf OpenEnterprise – 450ds1b.pdf Water Quality and SCADA security on the www.ControlWave.com web site. Complete specifications are available on the www.EmersonProcess.com/Remote web site. © 2007 Remote Automation Solutions, division of Emerson Process Management. All rights reserved. Bristol, Inc., Bristol Babcock Ltd, Bristol Canada, BBI SA de CV and the Flow Computer Division , are wholly owned subsidiaries of Emerson Electric Co. doing business as Remote Automation Solutions (“RAS”), a division of Emerson Process Management. FloBoss, ROCLINK, Bristol, Bristol Babcock, ControlWave, TeleFlow and Helicoid are trademarks of RAS. AMS, PlantWeb and the PlantWeb logo are marks of Emerson Electric Co. The Emerson logo is a trademark and service mark of the Emerson Electric Co. All other marks are property of their respective owners. The contents of this publication are presented for informational purposes only. While every effort has been made to ensure informational accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. RAS reserves the right to modify or improve the designs or specifications of such products at any time without notice. All sales are governed by RAS’ terms and conditions which are available upon request. RAS does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any RAS product remains solely with the purchaser and end-user. Emerson Process Management Remote Automation Solutions Watertown, CT 06795 USA Mississauga, ON 06795 Canada Worcester WR3 8YB UK T 1 (860) 945-2200 T 1 (905) 362-0880 T 44 (1) 905-856950 Website: www.EmersonProcess.com/Remote
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.0-c006 1.236519, Wed Jun 14 2006 08:31:24 Create Date : 2007:10:01 15:08:50-04:00 Metadata Date : 2007:10:01 15:08:54-04:00 Modify Date : 2007:10:01 15:08:54-04:00 Creator Tool : Adobe InDesign CS3 (5.0) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 11618 bytes, use -b option to extract) Instance ID : uuid:1fa6b5f7-34ae-4d04-8eb1-ac878c4b0dbc Document ID : adobe:docid:indd:b36b6b02-3568-11dc-9a91-ba192b9da466 Rendition Class : proof:pdf Derived From Instance ID : b36b6b01-3568-11dc-9a91-ba192b9da466 Derived From Document ID : adobe:docid:indd:b36b6b00-3568-11dc-9a91-ba192b9da466 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00 Manifest Placed Y Resolution : 300.00, 300.00, 72.00, 300.00, 300.00, 300.00, 300.00, 300.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:DF257867182BDC11A4CBD621E1E6385A, uuid:ecf06eaa-9134-11db-ba6f-8ba6315731f8, uuid:e881b4d2-a317-11da-b231-f81770e95b38, uuid:1B15B498D42BDC1189DFD5E8E0774FD3, uuid:C5E6BC85D52BDC1189DFD5E8E0774FD3, uuid:072879A1D62BDC1189DFD5E8E0774FD3, uuid:28942BB8D62BDC1189DFD5E8E0774FD3, uuid:A94055D0D62BDC1189DFD5E8E0774FD3 Manifest Reference Document ID : uuid:DE257867182BDC11A4CBD621E1E6385A, adobe:docid:photoshop:ecf06ea9-9134-11db-ba6f-8ba6315731f8, adobe:docid:photoshop:e881b4d1-a317-11da-b231-f81770e95b38, uuid:1A15B498D42BDC1189DFD5E8E0774FD3, uuid:C4E6BC85D52BDC1189DFD5E8E0774FD3, uuid:062879A1D62BDC1189DFD5E8E0774FD3, uuid:27942BB8D62BDC1189DFD5E8E0774FD3, uuid:A84055D0D62BDC1189DFD5E8E0774FD3 Format : application/pdf Producer : Adobe PDF Library 8.0 Trapped : False Page Count : 6 Creator : Adobe InDesign CS3 (5.0)EXIF Metadata provided by EXIF.tools