2.5:DVS205 January 2009 Specification Sheet DVS205 Dual-Variable Sensor The DVS205 Dual-Variable Sensor (DVS) provides static pressure and differential pressure inputs to a FloBoss™ 103, FloBoss 107E, or FloBoss 500-Series Flow Manager. The DVS205 communicates via a serial format with the FloBoss. Variables Functionally, the DVS is a digital transmitter that measures two flow-related variables simultaneously: differential pressure and static pressure. These variables are continuously available to the FloBoss unit that polls the DVS. Transducer and Electronics The DVS contains a transducer and an electronics circuit. The transducer uses capacitance-cell technology to sense differential pressure and piezoresistive technology to sense the static (absolute or gauge) pressure. The transducer electronics convert the pressure variables directly into a digital format, allowing accurate correction and compensation. A microprocessor linearizes and corrects the raw pressure signals (from the sensor) using characterization data stored in non-volatile memory. The electronics also allow the DVS to communicate with a FloBoss using a Serial Peripheral Interface (SPI). Accuracy Two versions of the DVS transmitter are available: DVS205P with reference accuracy of 0.075% of the full span. DVS205E with reference accuracy of 0.10% of the full span. Mounting The DVS is factory installed on a FloBoss™ 103, FloBoss 107E, or FloBoss 500-Series Flow Manager to comply with agency requirements. Attached to the bottom of the sensor body is a Coplanar™ flange. This flange allows the DVS to mount on an integral orifice assembly or manifold valve. Coupling Sensor Body DVS205 Dual-Variable Sensor Remote Automation Solutions Website: www.EmersonProcess.com/Remote D301569X012 Coplanar Flange 2.5:DVS205 Page 2 Specification Sheet DVS205 Dual-Variable Sensor Specifications DIFFERENTIAL PRESSURE INPUT Range1: (100:1 rangeability allowed) 0 to 62.2 kPa (0 to 250" H2O). 0 to 248.8 kPa (0 to 1000" H2O). Reference Accuracy: ±0.10% of span for turndowns from 1:1 to 10:1 of URL (DVS205E). ±0.075% of span for turndowns from 1:1 to 10:1 of URL (DVS205P). For spans less than 10:1 turndown: Accuracy = ±[0.025 + 0.005(URL/Span)]% of span. Stability: ±0.125% of URL for five years for ±50°F (28°C) ambient temperature changes, and up to 1000 psi (68,9 bar) line pressure. Ambient Temperature Effect per 50°F (28°C): ±(0.025% URL + 0.125% of span) spans from 1:1 to 30:1. ±(0.035% URL + 0.175% of span) spans from 30:1 to 100:1. Static Pressure Effects: Zero error = ±0.05% of URL per 1000 psi (68,9 bar). Span error = ±0.20% of DP Reading per 1000 psi (68,9 bar). Over-Pressure Limit: 3,626 psi (250 bar) applied on either or both sides without damage to the sensor. Burst Pressure Limit: 10,065 psi (694 bar). STATIC PRESSURE INPUT Range: Either Absolute or Gauge (100:1 rangeability allowed): 0 to 5516 kPa (0 to 800 psia/psig). 0 to 25,000 kPa (0 to 3626 psia/psig). Reference Accuracy: ±0.10% of span for turndowns from 1:1 to 10:1 of URL (DVS205E). ±0.075% of span for turndowns from 1:1 to 10:1 of URL (DVS205P). For spans less than 10:1 turndown: Accuracy = ±[0.03 + 0.0075(URL/Span)]% of span. STATIC PRESSURE INPUT (continued) Stability: ±0.125% of URL for five years for ±50°F (28°C) ambient temperature changes. Ambient Temperature Effect per 50°F (28°C): ±(0.05% URL + 0.125% of span) spans from 1:1 to 30:1. ±(0.06% URL + 0.175% of span) spans from 30:1 to 100:1. Over-Pressure Limit: Same as URL. POWER Input at 0 to 75°C (32 to 167°F): 8 to 30 V dc, 10 mW average. Input at –40 to 0°C (–40 to 32°F): 8.5 to 30 V dc, 10 mW average. OUTPUT Serial Peripheral Interface (SPI). WEIGHT 3.0 kg (6.7 lb). ENVIRONMENTAL Same as the FloBoss unit in which it is installed. Process Seals per ANSI/ISA 12.27.01 Meets requirements for a Single Seal device as defined by ANSI/ISA 12.27.01. Installation must adhere to the following process temperature limits. Process Temperature (at transmitter isolator flange): Standard Silicone Fill Sensor: -40 to 100°C (-40 to 212°F). Inert Fill Sensor: -18 to 85°C (0 to 185°F). Note: Process temperatures above 85°C (185°F) require you to lower the product’s maximum ambient temperature rating by a 1.5:1 ratio. To determine the adjusted maximum temperature rating, perform the following calculation: Adjusted max Tamb = Product Max Tamb - [(Actual Process Tamb - 85°C (185°F)) * 1.5]. Example: Adjusted Max Tamb = 75°C – [(95°C – 85°C) * 1.5] = 60°C. DIMENSIONS 147 mm H by 163 mm W by 84 mm D (5.8 in. H by 6.4 in. W by 3.3 in. D). VIBRATION EFFECT Sensor outputs will not shift more than +0.1% of URL per g from 5 to 2000 Hz in any axis when tested per IEC 770, Section 6.2.14. 1. Consult factory for special ranges and materials which may be available. For example: 0 to 6.22 kPa (0 to 25" H2O) at ±0.10% reference accuracy. 2.5:DVS205 Page 3 Specification Sheet DVS205 Dual-Variable Sensor Specifications (continued) CONSTRUCTION Standard: Transducer is all stainless steel construction with silicone fill fluid, 316L diaphragms and glass-filled PTFE o-rings. Coupling is A360 Aluminum with urethane coating. Optional: Transducer includes Hastelloy C-276 wetted parts (construction is NACE compliant per MR0103 and ISO15156/MR0175), inert fill fluid. Coupling is available in 316 stainless steel (CF8M). MOUNTING Factory-installed on enclosure of FB103, FB107E, and FB503. See respective specification sheet for unit mounting options. CONNECTIONS Process: 1/4-18 NPT on 2-1/8 inch centers (on coplanar flange). APPROVALS Same as the FloBoss unit in which it is installed. Specification Sheet 2.5:DVS205 Page 4 Bristol, Inc., Bristol Canada, BBI SA de CV and Emerson Process Management Ltd, Remote Automation Solutions division (UK), are wholly owned subsidiaries of Emerson Electric Co. doing business as Remote Automation Solutions (“RAS”), a division of Emerson Process Management. FloBoss, ROCLINK, Bristol, Bristol Babcock, ControlWave, TeleFlow and Helicoid are trademarks of RAS. AMS, PlantWeb and the PlantWeb logo are marks of Emerson Electric Co. The Emerson logo is a trademark and service mark of the Emerson Electric Co. All other marks are property of their respective owners. The contents of this publication are presented for informational purposes only. While every effort has been made to ensure informational accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. RAS reserves the right to modify or improve the designs or specifications of such products at any time without notice. All sales are governed by RAS’ terms and conditions which are available upon request. RAS does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any RAS product remains solely with the purchaser and end-user. Emerson Process Management Remote Automation Solutions Marshalltown, IA 50158 U.S.A. Houston, TX 77041 U.S.A Pickering, North Yorkshire UK Y018 7JA © 2008-2009 Remote Automation Solutions, division of Emerson Process Management. All rights reserved.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Page Count : 4 Page Layout : OneColumn XMP Toolkit : XMP toolkit 3.0-28, framework 1.6 About : uuid:19012e80-0a2d-401b-ab20-4c9865c871dc Producer : Acrobat Distiller 8.1.0 (Windows) Company : Fisher Controls Source Modified : D:20090105153346 Creator Tool : Acrobat PDFMaker 8.1 for Word Modify Date : 2009:01:05 09:42:23-06:00 Create Date : 2009:01:05 09:34:16-06:00 Metadata Date : 2009:01:05 09:42:23-06:00 Document ID : uuid:a74e8270-6f57-4416-9c77-5cca010b8110 Subject : 56 Instance ID : uuid:19012e80-0a2d-401b-ab20-4c9865c871dc Format : application/pdf Creator : Jan Mulder Title : HART Interface Module Tagged PDF : Yes Author : Jan MulderEXIF Metadata provided by EXIF.tools