1F78-144
1F78-151

CONFIGURATION AND
TYPICAL WIRING DIAGRAMS
CONFIGURATION

W

RH

B

RC

G

O

Y

W904

W905
Clip for
Hydronic
System

W905

ELEC

W904
Clip for
Celsius Display

GAS

Electric/Gas
Switch

TYPICAL WIRING DIAGRAMS
JUMPER
WIRE
B

Y

O

G

Cooling
System

W

RC

B

THERMOSTAT

RH

Y

G

W

Cooling
System

Fan
Relay

Heating
System

O

RC

RH

THERMOSTAT
SYSTEM

SYSTEM

Fan
Relay

Hot
24 VAC

120 VAC

Hot
24 VAC

Neutral

120 VAC

HEATING TRANSFORMER

Neutral

Hot

Cool only, 3-wire, single transformer systems

24 VAC

120 VAC
Neutral

COOLING TRANSFORMER

Heat/cool, 5-wire, two-transformer systems

JUMPER
WIRE
B

O

Y

NOTE
For 2-wire Heat only
attach to RH and W

G

W

Fan
Relay

Heating
System

RC

THERMOSTAT

RH

SYSTEM

Hot
24 VAC

JUMPER
WIRE
B

Y

O

JUMPER
WIRE

G

W

RC

RH

THERMOSTAT
SYSTEM

120 VAC
Neutral

TRANSFORMER

Heat only, 3-wire, single transformer systems

Reversing Compressor Fan
Valve*
Contactor Relay

Hot
24 VAC

* Reversing valve is energized when the
system switch is in the COOL position

120 VAC

Neutral
TRANSFORMER

TECHNICAL HELP

Heat pump with cool active reversing valve
JUMPER
WIRE
B

O

NOTE
RED jumper wire (provided
with thermostat) must be
connected between thermostat's RH and RC terminals
for proper thermostat operation with this system.

Y

Cooling
System

G

Fan
Relay

W

RC

RH

SYSTEM

Heating
System

Hot
24 VAC

120 VAC
Neutral

TRANSFORMER

Heat/cool, 4-wire, single transformer systems
190

JUMPER
WIRE

THERMOSTAT

www.white-rodgers.com

B

Reversing
Valve*

O

Y

G

JUMPER
WIRE
W

RC

THERMOSTAT

RH

SYSTEM

Compressor Fan
Contactor Relay

Hot
24 VAC

* Reversing valve is energized when the
system switch is in the HEAT position

120 VAC

Neutral
TRANSFORMER

Heat pump with heat active reversing valve



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Producer                        : itext-paulo (lowagie.com)[JDK1.1] - build 126
Modify Date                     : 2006:08:15 14:00:46-06:00
Create Date                     : 2006:08:15 14:00:46-06:00
Page Count                      : 1
EXIF Metadata provided by EXIF.tools

Navigation menu