Emerson Cf925Bk00 Owners Manual BP72 COOLER

CF925WW00 7ab6e915-84d0-44b9-adff-578527e6467f

2015-01-05

: Emerson Emerson-Cf925Bk00-Owners-Manual-164610 emerson-cf925bk00-owners-manual-164610 emerson pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

DownloadEmerson Emerson-Cf925Bk00-Owners-Manual- BP72 COOLER  Emerson-cf925bk00-owners-manual
Open PDF In BrowserView PDF
READ AND SAVE THESE INSTRUCTIONS

®

COOLER

™

Ceiling Fan
Owner's Manual
Net Weight:

26.8

Lbs.

Model No.

CF925BK 00
CF925BS 00
CF925WW 00
CF925OB 00

LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for thirty years from the date you purchased your ceiling fan. All other components and accessories are
covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Company Do To Correct Problems:
Emerson Company will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no charge to you. If repair of the
motor or blades is not practical or possible within a reasonable time and no replacement can be provided, Emerson Company will refund the actual purchase
price of your fan. We will ship the repaired product or replacement to you at no charge, but you are responsible for all costs or removal, reinstallation and
shipping of the product to Emerson Company.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR RECEIPT OR OTHER PROOF
OF PURCHASE. You can return the product to our factory or to your nearest authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to Air Comfort Products, Division of Emerson
Company, 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model numbers shown on the product with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service center. Your Emerson Air Comfort
Ceiling Fan should be properly packed to avoid damage in transit since we will not be responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any defects, malfunctions or failures
caused by:
• Repairs by persons not authorized by Emerson Company,
• Use of parts or accessories not authorized by Emerson Company,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral warranties apply, and no employee,
agent, dealer or other person is authorized to give any warranties on behalf of Emerson Company.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND EMERSON IS NOT RESPONSIBLE
FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL DAMAGES. Incidental damages include but are not limited to such damages
as loss of time and loss of use. Consequential damages include but are not limited to the cost of repairing or replacing other property which was damaged if
this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or limitation may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Part No. F40BP72050004

Form No. BP7205-4

!

WARNING

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting
means to prevent power from being switched on accidentally. When the service disconnecting means cannot
be locked, securely fasten a warning device, such as a tag, to the service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to
the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan
without blades.
2. All wiring must satisfy National and Local Electrical Codes. Use the National Electrical Code if Local Codes do
not exist. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical
installation should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted an capable of reliably supporting a least 50 pounds. Use
only U.L. outlet boxes listed as acceptable for fan support, and use the mounting screws provided with the
outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified electrician if in doubt.
4. The downrod furnished with the fan proves the minimum recommended floor to fan blade clearance for an
8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the
fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not know
enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not specifically
approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any accessories
designated specifically for use this product by Emerson Company could result in personal injury or property
damage.
WARNING: To Reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges,
balancing the blades or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

DATE CODE:

The date code of this fan may be found on
the box, stamped in ink on a white label.
You should record this data above and keep
it in a safe place for future use.

2

This Manual Is Designed to Make it as Easy as Possible for You to
Assemble, Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver
One 1/4” blade screwdriver
Three wire connectors (supplied)
One 3/16” hex wrench (supplied)

Installed Wire Length
Up to 50 ft.
50-100 ft.

One stepladder
One wire stripper

!

MATERIALS

Wire Size A.W.G.
14
12

WARNING

Before assembly your ceiling fan, refer to section on
proper method of wiring your fan (page 6). If you feel
you do not have enough wiring knowledge or
experience, have your fan installed by a licensed
electrician.

Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would
be a 3-conductor (2-wire with ground) of the following
size:

Unpacking Instructions
For your convenience, check-off boxes are provided next to each step. As each step is
completed, place a check mark in the box. This will insure that all steps have been
completed and will be helpful in finding your place should you be interrupted.
!

NOTE: Place the parts from the loose parts bags
in a small container to keep them from being lost.
If any parts are missing, contact your local
retailer or catalog outlet for replacement before
proceeding.

WARNING

Do not install or use fan if any part is damaged or
missing. Call Toll-Free:

1-800-654-3545
!

2. Remove the fan assembly from the protective
plastic bag. Place the fan assembly into the upper
foam pad with the top of the motor facing up.

WARNING

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Company. Substitution of parts or
accessories not designated for use with this product
by Emerson Company could result in personal injury
or property damage.

The upper foam pad serves as a holder for the fan
during the first stages of assembly.

COUPLER
COVER

FAN
ASSEMBLY

1. Check to see that you have received the following
parts:
NOTE: If you are uncertain of part description,
refer to exploded view illustration.
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
k.
l.

Fan motor assembly
One ceiling cover
Five fan blades
Five blade flanges
One hanger ball/downrod assembly
One hanger bracket
One glass globe
One SR100 fan/light control
One light kit plate
One adapter plate
One coupler cover
One loose parts bag containing:
1. Sixteen 3/16-24 x 5/16” slotted Phillips
washer head blade screws
2. Sixteen Fiber blade washers
3. Eleven 1/4-20 x 3/8” Phillips oval head
flange screws
4. Three wire connectors
5. Two 3/4" threaded studs
6. Two lockwashers
7. Two knurled knobs
8. One clevis pin
9. One hairpin clip
10. One 3/16” hex wrench
11. Three 3/16-24 nuts

HANGER
BRACKET

HANGER BALL/
DOWNROD
ASSEMBLY
CEILING
COVER

LIGHT KIT
PLATE

LOOSE
PARTS
BAG

ADAPTER PLATE

MED

HI

GLASS
BOWL

LOW

OFF

SR100
FAN/LIGHT
CONTROL

BLADE
FLANGES

FAN BLADES

3

How to Put Your Ceiling Fan Together
1. Remove the hanger ball by loosening the setscrew
in the hanger ball until the ball falls freely down the
downrod (Figure 1). Remove the clevis pin from the
downrod, then remove the hanger ball. Retain the
pin and hanger ball for reinstallation in step 5.

4. Make sure the grommet is properly installed in the
coupling cover then slide the coupler cover on the
downrod until it rests on the motor housing. Place
the ceiling cover over the downrod. Be sure both
the ceiling cover and the coupler cover are
oriented correctly (Figure 3).

PIN
HANGER
BALL
CEILING
COVER

COUPLER
COVER
CLEVIS
PIN

DOWNROD

SETSCREW

Figure 1

CLEVIS
PIN
HAIRPIN
CLIP

SETSCREW

2. Loosen setscrew in motor coupling if necessary.
Separate, untwist and unkink the three 80” motor
leads. Route the motor lead wires through the
downrod. Align the clevis pin holes in the downrod
with the holes in the motor coupling. Install the
clevis pin and secure with the hairpin clip (Figure
2). The clevis pin must go through the holes in the
motor coupling and the holes in the downrod. Be
sure to push the straight leg of the hairpin clip
through the hole near the end of the clevis pin until
the curved portion of the hairpin clip snaps around
the clevis pin. The hairpin clip must be properly
installed to prevent the clevis pin from working
loose. Pull on the downrod to make sure the clevis
pin is properly installed.
!

MOTOR
COUPLING

Figure 3

5. Reinstall the hanger ball (Figure 4) on the downrod
as follows. Route the motor leads through the
downrod. Position the pin through the two holes in
the downrod and align the ball so the pin is captured
in the groove in the top of the hanger ball. Pull the
hanger ball up tight against the pin and securely
tighten the setscrew in the hanger ball. A loose
setscrew could create fan wobble.
!

WARNING

It is critical that the pin in the hanger ball is properly
installed and the setscrew securely tightened.
Failure to verify that the pin and setscrew are
properly installed could result in the fan falling.

WARNING

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrew securely
tightened. Failure to verify that the pin and setscrew
are properly installed (as shown in Figure 2) could
result in the fan falling.

PIN
HANGER
BALL

DOWNROD

SETSCREW

DOWNROD
HAIRPIN
CLIP

Figure 4

SETSCREW

6. The fan comes with blue, black and white leads
that are 80” long. Before installing fan, measure up
approximately 6 to 9-inches above top of hanger
ball/downrod assembly. Cut off excess leads and
strip back insulation 1/2-inch from end of leads.

CLEVIS PIN

Figure 2

MOTOR
COUPLING

7. Mount blade flanges to fan blades using three
3/16-24 x 5/16” slotted Phillips washer head blade
screws and three fiber blade washers (Figure 5).

3. While pulling up on the downrod, securely tighten
the setscrew in the motor coupling (Figure 3).
NOTE: The setscrew must be properly installed as
described above, or fan wobble could result.
4

FIBER
BLADE
WASHER

11. Connect the white wire from the light kit plate to
the white wire from the motor; connect the black
wire from the light kit plate to the blue wire from
the motor (Figure 7). Make sure the connectors
are fully engaged.

3/16-24 x 5/16" SLOTTED
PHILLIP WASHER HEAD
BLADE SCREW (3)

12. Position the light kit plate so that the studs on the
adapter plate protrude through the three holes in
the light kit plate. Install a 3/16-24 nut on each
stud.

FAN BLADE

Figure 5

BLADE FLANGE

NOTE: Be sure the wires are not pinched between
the light kit plate and the spacers or motor shaft.

8. Turn fan assembly upside down in preparation for
mounting fan blade assemblies.

LIGHT KIT PLATE

NOTE: Take care not to scratch fan housing when
installing blades.
9.Attach blade assembly to motor hub using two 1/420 x 3/8” Phillips oval head flange screws. Make
sure the screws are tightened securely (Figure 6).
Repeat this procedure for other four blade
assemblies.

3/16-24 NUT (3)

Figure 8

Electrical Requirements
MOTOR
HUB

Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and
capable of withstanding a load of at least 50 pounds.

1/4-20 x 3/8"
FLANGE SCREWS
FLANGE

!

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician if in doubt.

Figure 6
!

WARNING

To reduce the risk of personal injury, do not bend the
blade flanges when installing the blades or cleaning
the fan. Do not insert foreign objects between
rotating fan blades.

If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time and
remove the existing light fixture.

10. Using the 3/16” hex wrench (supplied), loosen the
setscrew in the adapter plate collar. Pass the blue
and white leads through the collar and tightly
screw the adapter plate onto the motor shaft
(Figure 7). Securely tighten the setscrew in the
adapter plate collar.

!

WARNING

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse box before wiring. All
wiring must be in accordance with National and
Local codes and the ceiling fan must be properly
grounded as a precaution against possible electrical
shock.

NOTE: The setscrew must be securely tightened
to prevent the adapter plate from loosening when
the glass bowl is installed.
CONNECTORS
LIGHT
KIT PLATE

!

WARNING

To avoid fire or shock, follow all wiring instructions
carefully.
Any electrical work not described in these
instructions should be done or approved by a
licensed electrician.

SETSCREW
SPACER
ADAPTER
PLATE

Figure 7

WARNING

5

How to Hang Your
Ceiling Fan
!

NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.

OUTLET
BOX

WARNING

The fan must be hung with at least 7' of clearance
from floor to blades (Figure 9).

HANGER
BRACKET

CEILING

Figure 11

HANGER BALL/
DOWNROD ASSEMBLY

How to Wire Your Ceiling Fan

AT LEAST
7'

Figure 9

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.

FLOOR

!

WARNING

1. Your ceiling fan is supplied with an Emerson
SR100 Fan/Light Control. Wire your ceiling fan in
accordance with the Owner’s Manual supplied with
the SR100 Fan/Light Control. After splices have
been made, carefully push splices up into the outlet
box.

The outlet box must be securely anchored and capable
of withstanding a load of at least 50 lbs.
!

WARNING

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked acceptable for
fan support, and use screws supplied with outlet
box. Most outlet boxes commonly used for support
of light fixtures are not acceptable for fan support
and may need to be replaced. Consult a qualified
electrician in in doubt.

!

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

1. Securely attach the hanger bracket to the outlet
box using the two screws supplied with the outlet
box. (Figure 10.)

2. After completion of wiring, install the ceiling cover
as follows. Screw the two 3/4” threaded studs
(provided) into the tapped holes in the hanger
bracket.

OUTLET
BOX

3. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 12).

HANGER
BRACKET
TWO SCREWS
SUPPLIED WITH
OUTLET BOX

4. Secure the ceiling cover in place by sliding
lockwashers over the threaded studs and installing
the two knurled knobs (supplied). (Figure 12.)
Tighten the knurled knobs securely until the ceiling
cover fits snugly against the ceiling and the hole in
the ceiling cover is clear of the downrod. Your fan
is now wired to be turned on and off from the fan
switch.

TAB

Figure 10
!

WARNING

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

CEILING COVER

2.Carefully lift the fan and seat the hanger
ball/downrod assembly on the hanger bracket that
was just attached to the outlet box (Figure 11). Be
sure the groove in the ball is lined up with tab on
the hanger bracket (Figure 10).
!

KNURLED KNOB

Figure 12

WARNING

!

WARNING

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.

WARNING

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and
hanger bracket.

LOCKWASHERS (2)

3/4"
THREADED STUD

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.
!

WARNING

6

Installing Glass Globe
1. Install three candelabra base bulbs in sockets.
2. Place the glass bowl into the opening in the light kit
plate, aligning the three flat areas on the top edge
of the glass with the three raised dimples on the
light kit plate and turn the glass bowl clockwise until
it stops (Figure 13).

LIGHT KIT
PLATE

RAISED
DIMPLES

NOTE: periodically check that the glass bowl is
seated fully clockwise in the light kit plate.

FLAT AREA

Figure 13

Using Your Ceiling Fan
1. Restore electrical power to the outlet box by turning
the electricity on at the main fuse box or circuit
breaker panel.

turning, then slide the reversing switch to (located
at the top of the motor housing) opposite position,
and turn fan on again. The fan blades will turn in
the opposite direction and reverse the airflow.

2. All fans are shipped from the factory with the
reversing switch positioned to circulate air
downward. If airflow is desired in opposite direction,
turn your fan off and wait for the blades to stop

3. Refer to the Owner’s Manual supplied with the
SR100 Fan/Light Control for operation of the fan
and light.

WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER
BEFORE TROUBLE SHOOTING YOUR FAN.

Trouble Shooting
TROUBLE
1. Fan will not start.

PROBABLE CAUSE

SUGGESTED REMEDY

1. Fuse or circuit breaker blown.
2. Loose power line connections to the fan, or loose
switch wire connections in the switch housing.
3. Reversing switch in neutral position.

2. Fan sounds noisy.

3. Fan wobbles
excessively.

1. Check main and branch circuit fuses or circuit breakers.
2. Check line wire connections to fan and switch wire
connections in the switch housing.
CAUTION: Make sure main power is turned off.
3. Make sure reversing switch position is all the way to one
side.

1. Blades not attached to fan.
2. Screws securing fan blade flanges to motor are
loose.
3. Screws holding blades to flanges are loose.

1. Attach blades to fan before operating.
2. Check to make sure the screws which attach the fan
flanges to the motor are tight.
3. Tighten screws securely.

4. Glass bowl loose.

4. Tighten the glass bowl securely.

1. Setscrew in motor coupling is loose.
2. Setscrew in hanger ball/downrod assembly is
loose.
3. Screws securing fan blade flanges to motor are
loose.
4. Fan blade flanges not seated properly.

1. Raise coupler cover and tighten the setscrew securely.
2. Tighten the setscrew in the hanger ball/downrod assembly.

5. Hanger bracket and/or ceiling outlet box is not
securely fastened.
6. Fan blades out of balance.

7

3. Check to be sure screws which attach the fan blade
flanges to the motor are tight.
4. Check to be sure the fan blade flanges seat firmly and
uniformly to the surface of the motor. If flanges are
seated incorrectly, loosen the flange screws and retighten
according to the procedure in the section on "How to Put
Your Ceiling Fan Together".
5. Tighten the hanger bracket screws to the outlet box, and/or
secure outlet box.
6. Interchanging an adjacent (side-by-side) blade pair can
redistribute the weight and result in smoother operation.

Maintenance
IMPORTANT CARE INSTRUCTIONS
for your Ceiling Fan

Abrasive cleaning agents are not required and should
be avoided to prevent damage to finish.

Periodic cleaning of your new ceiling fan is the only
maintenance that is needed.

WARNING

!

When cleaning, use only a soft brush or lint free cloth
to avoid scratching the finish.

Do not use water when cleaning your ceiling fan. It
could damage the motor or the blades and create the
possibility of an electrical shock.

Accessories
1. Downrod Extension Kits (see store or catalog).
!

WARNING

!

WARNING

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Company. Substitution of parts or
accessories not designated for use with this product
by Emerson Company could result in personal injury
or property damage.

The use of any other control not specifically
approved for this fan could result in fire, shock and
personal injury.

Repair Parts Listing
Key
No.
—

Description

CF925WW 00

Model No.
CF925BK 00 CF925BS 00 CF925OB 00

761655

761655-1

761655-17

761655-9

1
2
3

Hanger Ball Assembly,
Consisting of:
Hanger Bracket
Hanger Ball
Downrod

—
—
—

—
—
—

—
—
—

—
—
—

—
4
5
6
7
8
9
11
13
15
16
23

Parts Bag Containing:
Wire Connector (3)
Stud, Threaded, 3/4" (2)
Lockwashers (2)
Knob, Knurled (2)
Pin, Clevis
Clip, Hairpin
Hex Wrench, 3/16”
Nut, 3/16-24 (3)
Screw, 1/4-20 x 3/8” (11)
Screw, 3/16-24 x 5/16” (16)
Fiber Blade Washer (16)

761729
—
—
—
—
—
—
—
—
—
—
—

761729-1
—
—
—
—
—
—
—
—
—
—
—

761729-2
—
—
—
—
—
—
—
—
—
—
—

761729-1
—
—
—
—
—
—
—
—
—
—
—

10

Adapter Plate

761696

761696-1

761696-2

761696-3

12

Light Kit Plate Assembly

761732

761732

761732

761732

14

Glass Globe

761670

761670

761670

761670

17

Blade (set of 5)

761727-1

761727

761727-2

761727-3

18

Flange (set of 5)

761728

761728-1

761728-2

761728-3

19

Canopy, Ceiling

761504-3

761504-9

761504-12

761504-11

20

Wiring Harness with Capacitor

761730

761730

761730

761730

21

Coupler Cover

761760

761760-1

761760-2

761760-3

22

SR100 Fan/Light Control

—

Owner's Manual

*

*

*

*

BP7205-4

BP7205-4

BP7205-4

BP7205-4

* Contact your nearest authorized Emerson fan dealer for replacement SR100 Fan/Light Control.

22

2
1

11

3
5
19

4
6
7

21
8

9

16
23

20

10
17
18
MED

HI

12
15

LOW

OFF

22

13
14

Before discarding packaging material, be certain all parts
have been removed.

HOW TO ORDER REPAIR PARTS
WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE
FOLLOWING INFORMATION:
• PART NUMBER
• PART DESCRIPTION
• NAME OF ITEM
• MODEL NUMBER
The model number of your Fan will be found on a label attached to
the top housing.
For repair parts, phone 1-800-654-3545.
Part No. F40BP72050004

Printed in Taiwan 09/99

EMERSON
Air Comfort Products
DIVISION OF EMERSON COMPANY
8100 W. Florissant, St. Louis, MO 63136
Form No. BP7205-4



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Page Count                      : 8
Create Date                     : 2001:03:15 15:53:01
Producer                        : Acrobat Distiller 3.01 for Power Macintosh
Author                          : Kathleen Singleton
Creator                         : QuarkXPressª 4.04: PSPrinter 8.3.1
Title                           :  BP72 COOLER
EXIF Metadata provided by EXIF.tools

Navigation menu