DownloadEmerson Emerson-Cornerstone-Cf1Orb01-Users-Manual- BP7250 CF1 Owner's Manual  Emerson-cornerstone-cf1orb01-users-manual
Open PDF In BrowserView PDF
READ AND SAVE THESE INSTRUCTIONS

1895
TM

®

TM

Model No.

CF1AB01
CF1PW01
CF1ORB01 CF1WB01
DATE CODE:
The date code of this fan may be found on
the box, stamped in ink on a white label.

Max. Weight: 27.0 Lbs.
With Blades

You should record this data above and keep
it in a safe place for future use.

CORNERSTONE® Series
Ceiling Fan Owner's Manual
Part No. F40BP73270000

Form No. BP7327
U.L. Model No.: CF1

!

WARNING

WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.

Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the
service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off
the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.

Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not
operate fan without blades.
2. All wiring must be in accordance with the National Electrical Codes “ANSI/NFPA 70-1999” and
Local Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling
fan must be grounded as a precaution against possible electrical shock. Electrical installation
should be made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least 50
pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support”, and use the mounting
screws provided with the outlet box. Most outlet boxes commonly used for support of light
fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified
electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan blade
clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental
contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do
not know enough about electrical wiring, have your fan installed by a licensed electrician.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not
specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any
accessories designated specifically for use with this product by Emerson Electric Co.. Substitution
of parts or accessories not designated for use with this product by Emerson Electric Co. could
result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the
blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.

This Manual Is Designed to Make it as Easy as Possible for You to
Assemble, Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver
Five wire connectors (supplied)

Installed Wire Length
Up to 50 ft.
50-100 ft.

One stepladder
One wire stripper

!

MATERIALS
Wiring outlet box and box connectors must be of type
required by the local code. The minimum wire would
be a 3-conductor (2-wire with ground) of the following
size:
2

Wire Size A.W.G.
14
12

WARNING

Before assembling your ceiling fan, refer to section on
proper method of wiring your fan (page 7). If you feel
you do not have enough wiring knowledge or
experience, have your fan installed by a licensed
electrician.

NOTE: Before discarding packaging material, be
certain all parts have been removed.

Unpacking Instructions
For your convenience, check-off boxes are
provided next to each step. As each step is
completed, place a check mark in the box. This
will insure that all steps have been completed and
will be helpful in finding your place should you be
interrupted.
!

FAN MOTOR AND
HOUSING ASSEMBLY
MOTOR
COVER

WARNING

Do not install or use fan if any part is damaged or
missing. Call Toll-Free:

1-800-654-3545
!

HANGER BALL/
DOWNROD
ASSEMBLY

LOOSE
PARTS
BAG

WARNING

HANGER
BRACKET

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal
injury or property damage.

BLADE FLANGES
(2-BLADE VERSION)
CEILING
COVER
TRIM
BLADE FLANGES
(4-BLADE VERSION)
CEILING
COVER

1. Open styrofoam unit containing fan. Remove top
half of styrofoam unit. Remove parts and check to
see that you have received the following:

UPPER
COVER
TRIM

DOWNROD
TRIM
BULB

a. Fan motor and housing assembly
b. One motor cover
c. One ceiling cover
d. One ceiling cover trim
e. Four blade flanges (14°)
f. Two blade flanges (20°)
g. One hanger ball/downrod assembly
h. One 18” downrod
i. One downrod trim
j. One decorative bulb
k. One hanger bracket
l. One upper cover trim
m.One lower trim assembly
n. One loose parts bag containing:
1. One setscrew
2. One setscrew wrench
3. Nine 10-32 x 5/8" oval head screws
4. Two 1” threaded studs
5. Two 1-1/4” threaded studs
6. Four knurled knobs
7. Four lockwashers
8. Five wire connectors
9. Seven 8-32 x 1/2" screws
10. One pull chain pendant and coupling
11. One hairpin clip
12. One clevis pin
13. Twenty-one 10-32 x 3/8" pan head
screws
14. Twenty-one flat washers

LOWER
TRIM
ASSEMBLY
18"
DOWNROD
DOWNROD TRIM

General Information
Your Cornerstone ® ceiling fan comes with two
sets of blade flanges. One set (consisting of two
flanges) allows you to use your fan with two
blades, as the original 1895 Ceiling Fan was
configured. The other set (consisting of four
flanges) allows you to use your fan with four
blades. Both sets of flanges, and the fan blades
you selected, are patterned after the original
1895 Ceiling Fan. If your ceiling is nine feet or
higher, you may use the 18-inch downrod, along
with the downrod trim and decorative bulb, to
further enhance the 1895 ceiling fan look.

NOTE: Place the parts from the loose parts bags
in small containers to keep them from being lost.
If any parts are missing, contact your local
retailer or catalog outlet for replacement before
proceeding.
3

Assembly Instructions
1. Remove the fan motor and housing assembly from
styrofoam packaging and position it so that the top
of the motor is facing you.
2.Remove the hanger ball from the downrod by
loosening the setscrew in the hanger ball until the
ball falls freely down the downrod (Figure 1).
Remove the pin from the downrod, then remove the
hanger ball. Retain the pin and hanger ball for
reinstallation in step 9.
PIN
HANGER BALL
DOWNROD

SETSCREW

!

WARNING

It is critical that the clevis pin in the motor coupling
is properly installed and the setscrew securely
tightened. Failure to verify that the pin and setscrew
are properly installed (as shown in Figure 3) could
result in the fan falling.

5. Install the setscrew (supplied) in the motor
coupling (Figure 3). While pulling up on the
downrod, tighten the setscrew using the setscrew
wrench (supplied).
NOTE: The setscrew must be properly installed as
described above, or fan wobble could result.

Figure 1

3. Separate, untwist and unkink the three motor
leads. Route the motor leads through the downrod
and seat the downrod in the motor coupling
(Figure 2).
NOTE: If your ceiling height is nine feet or higher,
you may use the 18-inch downrod, along with the
downrod trim and decorative bulb. If your ceiling
height is between eight and nine feet, you must
use the shorter 4-1/2” downrod.

MOTOR LEADS
(BLACK, WHITE,
AND BLUE)
DOWNROD
FAN MOTOR AND
HOUSING ASSEMBLY
SETSCREW
WRENCH

Figure 3
DOWNROD
HAIRPIN
CLIP
SETSCREW
MOTOR
COUPLING
CLEVIS PIN

WHITE LEAD
CONNECTED
BROWN LEADS
HAIRPIN
CLIP
CONNECTED
RED LEADS

DOWNROD
CLEVIS PIN
MOTOR
COUPLING

6. Screw two 1” threaded studs (supplied) into the
motor (Figure 4). Leave approximately 7/8” of the
stud extending above the motor. Slide the motor
cover over the downrod and rotate the cover until
the threaded studs protrude; install two
lockwashers and knurled knobs (supplied) to
secure the cover.
NOTE: Make sure the connected red leads, the
connected brown leads, and the white lead are
completely inside the motor cover and not
pinched between the motor cover and the motor.

KNURLED KNOB
LOCKWASHER

Figure 2

4. Align the clevis pin holes in the downrod with the
holes in the motor coupling. Install the clevis pin
and secure with the hairpin clip (Figure 3). (Pin and
clip are supplied in loose parts bag.) The clevis pin
must go through the holes in the motor coupling
and the holes in the downrod. Push the straight leg
of the hairpin clip through the hole near the end of
Figure 4
the clevis pin until the curved portion of the hairpin
clip snaps around the clevis pin. The hairpin clip
must be properly installed to prevent the clevis pin
from working loose. Pull up on the downrod to
make sure the clevis pin is properly installed.
4

MOTOR COVER

1" THREADED STUD
7/8"

MOTOR

7. If you have installed the
18” downrod, install the
downrod trim and
decorative bulb as
follows (Figure 5). Slide
the decorative trim
(grommet-end first) over
the downrod and seat
the grommet firmly
against the motor cover.
Then slide the decorative bulb (oriented as
shown) over the downrod, being certain that
the downrod trim seats
in the bottom grommet
of the decorative bulb.

12. Use the holes in the square recesses in the
motor hub marked with "4" and install the blade
assemblies in accordance with Steps 13 or 14.
13. FOUR-BLADE VERSION. Attach one blade
assembly to the motor hub using two 10-32 x 5/8"
oval head screws (supplied) (Figure 8). Do not
tighten completely at this time. Install remaining
blade assemblies in the same way. Gently snug
all flange screws to the motor hub, working
around the hub in a clockwise sequence. Next,
securely tighten all flange screws, again working
in a clockwise sequence. Failure to follow this
procedure could result in fan wobble.

18" DOWNROD
GROMMET
DECORATIVE
BULB

GROMMET

DOWNROD
TRIM
GROMMET
MOTOR COVER

14° FOUR-BLADE FLANGE

Figure 5

8. Position the ceiling cover trim and the ceiling cover
over the downrod. Be sure the cover is oriented
correctly, with the large opening at the top
(Figure 5).
9. Reinstall the hanger ball on the downrod (Figure 6)
as follows. Route the motor leads through the
hanger ball and slide the hanger ball over the
downrod. Install the pin through the holes at top of
the downrod and slide the hanger ball up the
downrod, aligning the ball so the pin is captured in
the groove in the top of the hanger ball. Pull the
hanger ball up tight against the pin and securely
tighten the setscrew in the hanger ball. A loose
setscrew could create fan wobble.

10-32 x 5/8"
OVAL HEAD SCREWS
(2 PER BLADE FLANGE)
MOTOR HUB

Figure 8

14. TWO-BLADE VERSION. Attach one blade
assembly to the motor hub using four
10-32 x 5/8” oval head screws (supplied)
(Figure 9). Install the other blade assembly in the
same manner. Gently snug all flange screws to
the motor hub. Make sure the ends of the flanges
are engaged, then securely tighten all flange
screws, working in a clockwise sequence.

PIN

20° TWO-BLADE FLANGE

HANGER BALL
DOWNROD

Figure 6

10-32 x 5/8"
OVAL HEAD SCREWS
(4 PER BLADE FLANGE)

10. The fan comes with blue, black and white leads
that are 80” long. Before installing fan, measure
up approximately 6 to 9-inches above the ball/
downrod assembly. Cut off excess leads and
strip back insulation 1/2-inch from end of leads.
11. Use five 10-32 x 3/8" pan head screws and flat
washers (supplied) to secure the flange to the
blade (Figure 7). Repeat for the remaining
blade(s).

!

WARNING

To reduce the risk of personal injury, do not bend the
blade flanges when installing the flanges, balancing
the blades or cleaning the fan. Do not insert foreign
objects between rotating fan blades.

15. Turn fan assembly over so the bottom is oriented
up. Partially install two 8-32 x 1/2” screws
(supplied) in the switch housing assembly (Figure
10). Slip the speed control switch chain through
the hole in the upper cover trim, then position the
cover trim on the switch housing assembly so
that the two screws protrude through the key hole
slots in the cover trim. Turn the cover trim fully
clockwise and then securely tighten the two
8-32 x 1/2” screws.

10-32 x 3/8"
PAN HEAD SCREW (5)
FLAT WASHER (5)
BLADE

BLADE
FLANGE

Figure 7

MOTOR HUB

Figure 9

5

How to Hang Your
Ceiling Fan

SWITCH HOUSING
ASSEMBLY

!

WARNING

The fan must be hung with at least 7' of clearance
from floor to blades (Figure 12).

TURN

TURN

UPPER COVER
TRIM

CEILING
HOLE FOR SPEED
CONTROL SWITCH
CHAIN
8-32 x1/2"
SCREW (2)

Figure 10

AT LEAST
7'

LOOKING UP INTO SWITCH HOUSING ASSEMBLY
FLOOR

Figure 12

16. Position the lower trim assembly on the upper
cover trim so that the tabs on the lower trim
assembly slide into the slots in the upper cover
trim (Figure 11). Then securely install four 8-32 x
1/2” screws (supplied).

!

WARNING

The outlet box must be securely anchored and capable
of withstanding a load of at least 50 lbs. Use only a U.L.
outlet box listed as “Acceptable for Fan Support”.
!

WARNING

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable
for Fan Support”, and use screws supplied with
outlet box. Most outlet boxes commonly used for
support of light fixtures are not acceptable for fan
support and may need to be replaced. Consult a
qualified electrician if in doubt.

UPPER
COVER
TRIM
SLOT

8-32 x 1/2"
SCREW (4)
LOWER TRIM
ASSEMBLY

1. Securely attach the hanger bracket to the outlet
box using the two screws supplied with the outlet
box. (Figure 13).

Figure 11

!

Electrical Requirements

WARNING

Hanger bracket must seat firmly against outlet box. If
the outlet box is recessed, remove wall board until
bracket contacts box. If bracket and/or outlet box are
not securely attached, the fan could wobble or fall.

Your new ceiling fan will require a grounded electrical
supply line of 120 volts AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored and
capable of withstanding a load of at least 50 pounds.
!

OUTLET
BOX

WARNING

To reduce the risk of fire, electric shock, or personal
injury, mount fan to outlet box marked “Acceptable
for Fan Support”, and use screws supplied with
outlet box. Most outlet boxes commonly used for
support of light fixtures are not acceptable for fan
support and may need to be replaced. Consult a
qualified electrician if in doubt.

TWO SCREWS
SUPPLIED WITH
OUTLET BOX

Figure 13

If your fan is to replace an existing ceiling light fixture,
turn electricity off at the main fuse box at this time
and remove the existing light fixture.
!

TAB

2. Carefully lift the fan and seat the hanger ball/
downrod assembly on the hanger bracket that was
just attached to the outlet box (Figure 14). Be sure
the groove in the ball is lined up with tab on the
hanger bracket (Figure 13).

WARNING

Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is turned
off at the main fuse box before wiring. All wiring must
be in accordance with national and local codes and
the ceiling fan must be properly grounded as a
precaution against possible electrical shock.

HANGER
BRACKET

!

WARNING

Failure to seat tab in groove could cause damage to
electrical wires and possible shock or fire hazard.

6

NOTE: CEILING COVER,
SUPPLY WIRES AND
FAN WIRES OMITTED
FOR CLARITY.

2. Securely connect the fan motor white wire to the
supply white (neutral) wire using wire connector
supplied (Figure 15). Securely connect the fan
motor black wire and blue wire to the supply black
(hot) wire using wire connector supplied
(Figure 16). After connections have been made,
turn leads upward and carefully push leads into the
outlet box, with the white and green leads on one
side of the outlet box and the black and blue leads
on the other side of the outlet box.

OUTLET
BOX

HANGER
BRACKET

Figure 14

HANGER BALL/
DOWNROD ASSEMBLY

!
!

WARNING

Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.

To avoid possible fire or shock, do not pinch wires
between the hanger ball/downrod assembly and the
hanger bracket.

3. Screw the two 1-1/4” threaded studs (supplied)
into the tapped holes in the hanger bracket
(Figure 16).

How to Wire Your
Ceiling Fan

4. Lift the ceiling cover and the ceiling cover trim up
to the threaded studs and turn until studs protrude
through the holes in the ceiling cover and trim
(Figure 16).

If you feel that you do not have enough electrical
wiring knowledge or experience, have your fan
installed by a licensed electrician.
1. Connect the green grounding lead from the hanger
ball and the green grounding lead from the hanger
bracket to the grounding conductor of supply (this
may be a bare wire or wire with green colored
insulation) (Figure 15). Securely connect wires
with wire connector supplied.
!

WARNING

5. Secure the ceiling cover and trim in place by
sliding lockwashers (supplied) over the threaded
studs and installing the two knurled knobs
(supplied) (Figure 16). Tighten the knurled knobs
securely until the ceiling cover fits snugly against
the ceiling and the hole in the ceiling cover is clear
of the downrod. Your fan is now wired to be turned
on and off from the fan switch.

WARNING

To avoid possible electrical shock, be sure electricity
is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is
grounded, contact a licensed electrician for advice,
as it must be grounded for safe operation.
1-1/4"
THREADED
STUD
SUPPLY
GROUND
WIRE

CEILING
COVER

BLACK AND BLUE
FAN WIRES

LISTED
WIRE
CONNECTOR (3)

LOCKWASHER

WHITE SUPPLY
(NEUTRAL)

KNURLED KNOB

CEILING
COVER
TRIM

Figure 16
GREEN WIRE
(GROUND) FROM
HANGER BRACKET
GREEN WIRE
(GROUND) FROM
HANGER BALL

!

WHITE FAN
WIRE

WARNING

To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box and
not pinched between the ceiling cover and the ceiling.

BLACK SUPPLY
(HOT)
NOTE: CEILING COVER
OMITTED FOR CLARITY.

Figure 15

NOTE: If you are using an Emerson Light Fixture
with your fan, see Light Fixture Owner’s Manual
for wiring.

7

Using Your Ceiling Fan

Attaching Light Kit

1. Restore electrical power to the outlet box by
turning the electricity on at the main fuse box.

To install an accessory light kit, first unscrew the finial
and remove the lower trim (Figure 18). Then remove
the center trim by removing four 8-32 x 1/2” screws.
Remove the threaded nipple from the center trim and
install the light kit in accordance with the light kit
Owner’s Manual.

2. Check the operation of the fan by gently pulling on
the 4-position speed control pull chain switch
(Figure 17). The operating sequence is as follows:

!

WARNING

To avoid possible electrical shock, be sure
electricity is turned off at the main fuse box before
wiring.

REVERSING
SWITCH

CENTER
TRIM

THREE-SPEED
1st Pull—HIGH
2nd Pull—Medium
3rd Pull—Low
4th Pull—OFF

SPEED
CONTROL
PULL CHAIN
SWITCH

8-32 x 3/8"
SCREW (4)

SPEED
CONTROL
PULL CHAIN
SWITCH

THREADED NIPPLE
LOWER TRIM

FINIAL

Figure 18

Figure 17

3. If airflow is desired in opposite direction, turn your
fan off and wait for the blades to stop turning, then
press the rocker switch located on top of the motor
housing, and turn the fan on again. The fan blades
will turn in the opposite direction and reverse
airflow.

8

Maintenance

Accessories

IMPORTANT CARE INSTRUCTIONS
for your Ceiling Fan

1. Ceiling Fan Light Kits (see store or catalog).
2. Downrod Extension Kits (see store or catalog).
3. Ceiling Fan Controls (see store or catalog).

Periodic cleaning of your new ceiling fan is the only
maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth
to avoid scratching the finish.

!

The use of any other control not specifically
approved for this fan could result in fire, shock and
personal injury.

Abrasive cleaning agents are not required and should
be avoided to prevent damage to finish.

!

WARNING

WARNING

!

Do not use water when cleaning your ceiling fan. It
could damage the motor or the blades and create the
possibility of an electrical shock.

WARNING

This product is designed to use only those parts
supplied with this product and/or any accessories
designated specifically for use with this product by
Emerson Electric Co. Substitution of parts or
accessories not designated for use with this product
by Emerson Electric Co. could result in personal
injury or property damage.

WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER
!
BEFORE TROUBLE SHOOTING YOUR FAN.

Trouble Shooting
TROUBLE
1. Fan will not start.

PROBABLE CAUSE

SUGGESTED REMEDY

1. Fuse or circuit breaker blown.

1. Check main and branch circuit fuses or circuit
breakers.

2. Loose power line connections to the fan, or loose
switch wire connections in the switch housing.

2. Check line wire connections to fan and switch
wire connections in the switch housing.

1. Blades not attached to fan.

1. Attach blades to fan before operating.

2. Loose screws in motor housing.

2. Check to make sure all screws in motor housing
are snug (not over-tight).

3. Screws securing fan blade flanges to motor hub
are loose.

3. Check to make sure the screws which attach
the fan flanges to the motor hub are tight.

!

2. Fan sounds noisy.

!

3. Fan wobbles
excessively.

WARNING: Make sure main power is turned off.

WARNING: Make sure main power is turned off.

4. Wire connectors inside switch housing rattling.

4. Check to make sure wire connectors in
switch housing are not rattling against each
other or against the interior wall of the switch
housing.

5

5. Tighten screws securely.

Screws holding blades to flanges are loose.

1. Setscrew in motor coupling is loose.

1. Raise motor cover and tighten setscrew securely.

2. Setscrew in hanger ball/downrod assembly is
loose.

2. Tighten the setscrew in the hanger ball/downrod
assembly.

3. Screws securing fan blade flanges to motor hub
are loose.

3. Check to be sure screws which attach the fan blade
flanges to the motor hub are tight.

4. Fan blade flanges not seated properly.

4. Check to be sure the fan blade flanges seat firmly and
uniformly to the surface of the motor hub. If flanges are
seated incorrectly, loosen the flange screws and
retighten according to step 13 in the section “Assembly
Instructions”.

5. Hanger bracket and/or ceiling outlet box is not
securely fastened.

5. Tighten the hanger bracket screws to the outlet box,
and/or secure outlet box.

6. Fan blades out of balance.

6. Interchanging an adjacent (side-by-side) blade pair can
redistribute the weight and result in smoother operation.
Or use supplied balancing kit to balance blades.

9

Repair Parts
Before discarding packaging material, be certain all parts have been removed.
2

How to Order
Repair Parts

1
3
18
16
38

6

WHEN ORDERING REPAIR PARTS,
ALWAYS GIVE THE FOLLOWING
INFORMATION:

17

• PART NUMBER
• PART DESCRIPTION
7

• NAME OF ITEM

18
19
15

19
20
37

• MODEL NUMBER
For repair parts, phone
1-800-654-3545.

27

39

40
35

5

4
26

23

25

24
8

33

9

28

34
10

21
12
11

36
29
24
22

14
13

31

30

10

32

Repair Parts Listing
Key
No.
—
1
2
3
6

Description
Hanger Pack, Containing:
Bracket, Hanger (1)
Hanger Ball Assembly (1)
Downrod (1)
Ceiling Canopy

Model No.
CF1AB01
761655-3
—
—
—
761620-3

Part Numbers
Model No.
Model No.
CF1ORB01
CF1PW01
761655-32
761655-22
—
—
—
—
—
—
761620-33
761620-30

Model No.
CF1WB01
761655-20
—
—
—
761620-26

7

Trim, Ceiling Cover

762077

762077-4

762077-2

762077-1

8

Hub, Rubber

760601

760601

760601

760601

9

Blade Assembly
(Sold Separately)

—

—

—

—

10

Flange Set
(Full set for four blades)

762108

762108-4

762108-2

762108-1

11

Flange Set
(Full set for two blades)

762109

762109-4

762109-2

762109-1

12

Switch Cup

761449

761449-27

761449-22

761449-20

15

Cover, Motor

761621-3

761621-25

761621-21

761621-17

25

Motor

762508

762508

762508

762508

4
5
13
14
16
17
18
19
20
21
22
23
24
26
27
28

Parts Bag Containing:
Pin, Clevis (1)
Clip, Hairpin (1)
Coupling (1)
Pendant (1)
Wire Connector (5)
Wrench, Setscrew (1)
Stud, Threaded 1-1/4” (2)
Lockwasher (4)
Knob, Knurled (4)
Screw, 10-32 x 5/8” (9)
Screw, 8-32 x 1/2” (7)
Screw, 10-32 x 3/8” (21)
Washer, Flat (21)
Setscrew (1)
Stud, Threaded, 1” (2)
Trim, Upper Cover

762462
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
762084

762462
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
762084-4

762462
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
762084-2

762462
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
762084-1

29

Trim, Center

762085

762085-4

762085-2

762085-1

30

Nipple, Threaded

760939-1

760939-1

760939-1

760939-1

31

Trim, Lower

762086

762086-4

762086-2

762086-1

32

Finial

762163

762163-4

762163-2

762163-1

33

Washer, 9/16”

—

—

—

—

34

Lockwasher, 9/16”

—

—

—

—

35

Aux. Capacitor

761453

761453

761453

761453

36

Harness, Wiring

762090

762090

762090

762090

37

Screw, #8 Washerhead,
8-32 x 3/8” (4)

—

—

—

—

38

Bulb, Decorative

762144

762144-4

762144-2

762144-1

39

Downrod, 18”

760239-40

760239-233

760239-161

760239-146

40

Trim, Downrod

762143

762143-4

762143-2

762143-1

—

Owner's Manual

BP7327

BP7327

BP7327

BP7327

11

LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in
workmanship and materials. You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this warranty will last for the lifetime of your ceiling fan. All other components and accessories are
covered by this warranty for one year from the date you purchased your ceiling fan. ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, MADE WITH RESPECT TO COMPONENTS AND
ACCESSORIES IS ALSO LIMITED TO ONE YEAR.
What Will Emerson Electric Co. Do To Correct Problems:
Emerson Electric Co. will replace a defective Emerson Air Comfort Ceiling Fan motor, blade, component or other accessory at no
charge to you. If repair of the motor or blades is not practical or possible within a reasonable time and no replacement can be
provided, Emerson will refund the actual purchase price of your fan. WE WILL SHIP THE REPAIRED PRODUCT OR
REPLACEMENT TO YOU AT NO CHARGE, BUT YOU ARE RESPONSIBLE FOR ALL COSTS OR REMOVAL, REINSTALLATION AND
SHIPPING OF THE PRODUCT TO EMERSON.
How Can You Get Service:
YOU MUST HAVE PROOF OF YOUR PURCHASE OF THE CEILING FAN TO OBTAIN LIMITED WARRANTY SERVICE. KEEP YOUR
RECEIPT OR OTHER PROOF OF PURCHASE. You can return the product to our factory or to your nearest
authorized service center.
• To return the product to the factory, obtain a return authorization and service identification tag by writing to
Air Comfort Products, Division of Emerson Electric Co., 8100 W. Florissant Ave., St. Louis, MO 63136. Include all model
numbers shown on the product with your request.
• To return the product to an authorized service center, call 1-800-654-3545 for the address of the nearest authorized service
center.
You will be responsible for all insurance, freight or other transportation charges to our factory or authorized service
center. Your Emerson Air Comfort Ceiling Fan should be properly packed to avoid damage in transit since we will not be
responsible for any such damage.
What Is Not Covered:
The glass globes and light bulbs of your ceiling fan are not covered by this warranty. This warranty also does not cover any
defects, malfunctions or failures caused by:
• Repairs by persons not authorized by Emerson Electric Co.,
• Use of parts or accessories not authorized by Emerson Electric Co.,
• Mishandling, improper installation, modifications or damage to your ceiling fan while in your possession, or
• Unreasonable use, misuse, abuse, including failing to do reasonable and necessary maintenance, and normal wear and tear.
Additionally, this warranty and any implied warranty of merchantability or fitness for a particular purpose are voided when:
• The original purchaser or user ceases to own the product, or
• The fan is moved from its original point of installation.
This warranty is only valid within the 50 states of the United States and the District of Columbia. No other written or oral
warranties apply, and no employee, agent, dealer or other person is authorized to give any warranties on behalf of Emerson
Electric Co.
REPAIR, REPLACEMENT OR A REFUND ARE THE EXCLUSIVE REMEDIES AVAILABLE UNDER THIS WARRANTY AND
EMERSON IS NOT RESPONSIBLE FOR DAMAGES OF ANY KIND, INCLUDING INCIDENTAL AND CONSEQUENTIAL
DAMAGES. Incidental damages include but are not limited to such damages as loss of time and loss of use. Consequential
damages include but are not limited to the cost of repairing or replacing other property which was
damaged if this product does not work properly.
How State Law Relates To The Warranty:
Some states do not allow the exclusion or limitation of incidental or consequential damages so the above exclusion or
limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary
from state to state.

Air Comfort Products
Printed in China 03/06
Part No. F40BP73270000

DIVISION OF EMERSON ELECTRIC CO.
8100 W. Florissant ¥ St. Louis, MO 63136
Form No BP7327



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.1
Linearized                      : No
Page Count                      : 12
Create Date                     : 2006:03:23 14:34:34
Producer                        : Acrobat Distiller 3.01 for Power Macintosh
Author                          : Kathleen Singleton
Creator                         : QuarkXPressª 4.04: PSPrinter 8.3.1
Title                           : BP7250 CF1 owner's manual
EXIF Metadata provided by EXIF.tools

Navigation menu