www.Fisher.com
Baumannt84000 Sanitary
Control Valves
The Baumann 84000 sanitary control valves are
designed to satisfy the stringent demands of the
pharmaceutical and biotechnology industries. These
valves are in compliance with 3A Sanitary Standards
Inc. requirements. Incorporating reliable class III
diaphragm technology, the 84000 valves can handle
temperatures up to 160_C(320_F). The uniquely
shaped diaphragm, unlike plug style sanitary valves,
results in low shear forces in the flow stream,
minimizing possible damage to delicate bio-media or
altering the consistency of end product.
Features
Electropolished internal surfaces
USP 24 Class VI PTFE, EPDM backed diaphragm
Designed for Clean-in-Place (CIP) and
Sanitize-in-Place (SIP) service
Self-draining in preferred mounting mode
Compact size, see figures 9 to 10 and tables 14 to
15
FDA approved epoxy powder-coated actuator with
stainless steel fasteners for maximum corrosion
resistance
Stainless steel spring case and yoke available
Multi-spring field-reversible actuators with reduced
deadband permits direct operation from remote
signal devices
FisherrFIELDVUEtdigital valve controller available
for remote calibration and diagnostics in facilities
utilizing the PlantWebtarchitecture
84000 Inline Sanitary Valve with Baumann 32 Actuator
W9838
84000 Angle Sanitary Valve with Baumann 32 Actuator
and FIELDVUE DVC2000 Digital Valve Controller
W9839
84000 Angle Sanitary Valve with Baumann 54 Actuator
and FIELDVUE DVC6000 Digital Valve Controller
W9840
84000 Valve
D103343X012
Product Bulletin
52.1:84000
November 2012
84000 Valve
D103343X012
Product Bulletin
52.1:84000
November 2012
2
Figure 1. Baumann 84000 NPS 1 Angle Valve Body
Sub-Assembly
E1314
Figure 2. Baumann 84000 NPS 1 Inline Valve Body
Sub-Assembly
E1315
Table 1. Materials of Construction for NPS 1 Angle and Inline Valves
Key
Number Description Material
1Valve Body ASTM A479 S31603 stainless steel, annealed
2Bonnet ASTM A479 S30400 Annealed
3Piston Stem Sub-assembly Stainless Steel
4Drive Mechanism Sub-assembly Multiple (predominantly stainless steel)
5Compressor S30300 or S30400 stainless steel
6Wave Spring S17700 stainless steel
7Retaining Ring S30200 stainless steel
8Diaphragm, Closure Member PTFE face with Aramid fabric reinforced EPDM backing and S30400 stainless steel insert.
Diaphragm assembly conforms to FDA 21CFR 177.1550 and USP24 Class VI standards.
9Drive Nut, Actuator Yoke S30400 stainless steel
11 Bonnet Flange ASTM A240 S30400 stainless steel
13 O-Ring, Stem FKM fluorocarbon
14 Tell Tale Port S31600 stainless steel
18 Hex Head Cap Screw Grade B8, Class 1
27 Locknuts S30400 stainless steel
58 Travel Indicator S30400 stainless steel
84000 Valve
D103343X012
Product Bulletin
52.1:84000
November 2012
3
Figure 3. Baumann 84000 NPS 1-1/2 and 2 Angle
Valve Body Sub-Assembly
E1316
Figure 4. Baumann 84000 Linkage Mechanism
E1317
Table 2. Materials of Construction for NPS 1-1/2 and 2 Angle Valves
Key
Number Description Material
1Valve Body ASTM A479 S31603 stainless steel, annealed
2Bonnet ASTM A479 S30400 Annealed
3Piston Stem Sub-assembly Stainless Steel
4Drive Mechanism Sub-assembly Multiple (predominantly stainless steel)
5Compressor S30300 or S30400 stainless steel
6Wave Spring S17700 stainless steel
7Retaining Ring S30200 stainless steel
8Diaphragm, Closure Member PTFE face with Aramid fabric reinforced EPDM backing and S30400 stainless steel insert.
Diaphragm assembly conforms to FDA 21CFR 177.1550 and USP24 Class VI standards.
9Drive Nut, Actuator Yoke S30400 stainless steel
11 Clamp S30400 stainless steel
13 O-Ring, Stem FKM fluorocarbon
14 Tell Tale Port S31600 stainless steel
15 O-Ring EPDM, conforming to FDA 21CFR 177.1550
27 Locknuts S30400 stainless steel
58 Travel Indicator S30400 stainless steel
84000 Valve
D103343X012
Product Bulletin
52.1:84000
November 2012
4
Table 3. Cv Values at Percent Plug Opening
VALVE
SIZE FLOW
DIRECTION
(1)
ACTUATOR
TRAVEL Cv VERSUS PERCENT OF ACTUATOR TRAVEL OPEN
NPS Inches 10 20 30 40 50 60 70 80 90 100
1
Angle &
Inline
AtoB
or
BtoA
0.50 0.02 0.09 0.20 0.40 0.64 0.90 1.16 1.44 1.72 2.00
0.50 0.03 0.16 0.36 0.90 1.20 1.75 2.30 2.90 3.50 4.00
0.75 0.04 0.24 0.62 1.20 2.00 3.10 4.20 5.50 6.80 8.00
1-1/2
Angle
AtoB 0.50 1.45 3.07 4.86 6.95 9.34 12.0 14.3 16.7 19.1 21.7
0.75 2.18 4.86 8.00 12.0 15.5 19.1 22.9 25.9 28.2 29.6
BtoA 0.50 1.82 3.61 5.39 7.42 9.66 12.1 13.4 14.6 15.7 17.1
0.75 2.73 5.39 8.43 12.1 14.1 15.7 17.8 20.2 22.5 24.2
2
Angle
AtoB 0.50 2.60 3.0 3.90 6.94 10.4 14.2 18.4 22.4 26.1 29.4
0.75 2.70 3.90 8.46 14.2 20.5 26.1 31.0 35.3 39.6 42.6
BtoA 0.50 0.50 0.80 1.35 2.49 5.81 11.3 14.6 17.9 21.5 23.5
0.75 0.50 1.35 3.06 11.3 16.2 21.5 24.5 26.0 29.2 32.5
1. Flow A to B is recommended for low discharge pressure. Low discharge pressure being defined as near or below atmospheric pressure.
Table 4. Kv Values at Percent Plug Opening
VALVE
SIZE FLOW
DIRECTION
(1)
ACTUATOR
TRAVEL Kv VERSUS PERCENT OF ACTUATOR TRAVEL OPEN
DN mm 10 20 30 40 50 60 70 80 90 100
25 Angle
&Inline
AtoB
or
BtoA
12.7 0.017 0.077 0.17 0.34 0.55 0.77 0.998 1.24 1.48 1.72
12.7 0.026 0.138 0.31 0.77 1.03 1.51 1.98 2.49 3.01 3.44
19.05 0.034 0.206 0.53 1.03 1.72 2.67 3.61 4.73 5.85 6.88
40
Angle
AtoB 12.7 1.25 2.64 4.18 5.98 8.03 10.32 12.29 14.36 16.43 18.66
19.05 1.88 4.18 6.88 10.32 13.33 16.43 19.69 22.27 24.25 25.46
BtoA 12.7 1.57 3.10 4.64 6.38 8.31 10.41 11.52 12.56 13.50 14.71
19.05 2.35 4.64 7.25 10.41 12.13 13.50 15.31 17.37 19.35 20.81
50
Angle
AtoB 12.7 2.24 3.0 3.35 5.97 8.94 12.21 15.82 19.26 22.45 25.28
19.05 2.33 3.35 7.28 12.21 17.63 22.45 26.66 30.36 34.06 36.64
BtoA 12.7 0.43 0.69 1.16 2.14 4.98 9.72 12.56 15.39 18.49 20.21
19.05 0.43 1.16 2.63 9.72 13.93 18.49 21.07 22.36 25.11 27.95
1. Flow A to B is recommended for low discharge pressure. Low discharge pressure being defined as near or below atmospheric pressure.
84000 Valve
D103343X012
Product Bulletin
52.1:84000
November 2012
5
Table 5. Technical Specifications
VALVE SIZE NPS 1 Angle & Inline NPS 1-1/2 Angle NPS 2 Angle
RATED
Installed with flow from
Port A to B
Cv 2 4 8 22 30 29 43
Kv 1.72 3.44 6.88 18.92 25.8 24.94 36.98
Installed with flow from
Port B to A
Cv 2 4 8 17 24 24 32
Kv 1.72 3.44 6.88 14.62 20.64 20.64 27.52
TRAVEL mm 12.7 12.7 19.05 12.7 19.05 12.7 19.05
inches 0.50 0.50 0.75 0.50 0.75 0.50 0.75
BONNET Bolted Clamped
ACTUATOR TYPE 32 or 54 54
RANGEABILITY 100:1
CHARACTERISTIC Modified Equal Percentage
SEAT LEAKAGE ASME/FCI 70-2, Class VI
MAXIMUM OPERATING PRESSURE 10.34 bar (150 Psi)
MAXIMUM OPERATING TEMPERATURE 160_C (320_F)
INTERNAL BODY FINISH (WETTED INTERIOR) <30RaMicroinch/0.76RaMicron(standard)
< 20 Ra Microinch / 0.51 Ra Micron (optional - or as required)
END CONNECTIONS Sanitary (optional welded ends)
Table 6. Actuator Specifications
TYPE 32 Multi-Spring Diaphragm (Single-Acting) 54 Multi-Spring Diaphragm (Single-Acting)
NOMINAL SIZE 32 in254 in2
AIR FAILURE Open or Closed
TRAVEL 12.7 to 19.05 mm (0.50 or 0.75 inches)
AMBIENT TEMPERATURE RANGE -29 to 82_C (-20 to 180_F)
MAXIMUM AIR PRESSURE 2.4 bar (35 psig)
DIAPHRAGM MATERIAL Nitrile / Polyester
SPRING CASES
JSteel, Powder Epoxy-Coated Appliance White per FDA 21 CFR 175.300
or
JStainless Steel
FASTENERS Stainless Steel
YOKE
JDuctile Iron, Powder Epoxy-Coated Appliance White per FDA 21 CFR 175.300
or
JCast Stainless Steel
84000 Valve
D103343X012
Product Bulletin
52.1:84000
November 2012
6
Figure 5. Preferred Flow Directions for Self-Draining
E1318 E1319
E1320
E1321
NPS 1 ANGLE VALVE BODY POSITIONED FOR
FORWARD FLOW SELF DRAINING FROM PORT A TO B
NPS 1 INLINE VALVE BODY POSITIONED FOR
FORWARD FLOW SELF DRAINING FROM PORT A TO B
NPS 1-1/2 AND 2 ANGLE VALVE BODY (RECOMMENDED FOR PROCESSES
WHERE ATMOSPHERIC OR SLIGHT VACUUM IS PRESENT DOWNSTREAM
OF PORT B [PORTS A AND B MUST BE DRAINED SEPARATELY)
NPS 1-1/2 AND 2 ANGLE VALVE BODY POSITIONED
FOR SELF DRAINING FROM PORT B TO A
84000 Valve
D103343X012
Product Bulletin
52.1:84000
November 2012
7
Table 7. Model Numbering System
VALVE SIZE MODEL NUMBER(1, 2) TRAVEL TYPE (Flow Direction) RATED
NPS DN Inches mm Cv Kv
1
Angle
25
Angle
32-84021SAB 0.50 12.7 ANGLE (Port A to B) 21.72
32-84041SAB 0.50 12.7 ANGLE (Port A to B) 43.44
54-84041SAB 0.50 12.7 ANGLE (Port A to B) 43.44
32-84081SAB 0.75 19.05 ANGLE (Port A to B) 86.88
54-84081SAB 0.75 19.05 ANGLE (Port A to B) 86.88
1
Inline
25
Inline
32-84021SIB 0.50 12.7 ANGLE (Port A to B) 21.72
32-84041SIB 0.50 12.7 ANGLE (Port A to B) 43.44
54-84041SIB 0.50 12.7 ANGLE (Port A to B) 43.44
32-84081SIB 0.75 19.05 ANGLE (Port A to B) 86.88
54-84081SIB 0.75 19.05 ANGLE (Port A to B) 86.88
1-1/2
Angle
40
Angle
54-84161SAB 0.50 12.7 ANGLE (Port A to B) 22 18.92
54-84351SAB 0.75 19.05 ANGLE (Port A to B) 30 25.8
54-84161SA 0.50 12.7 ANGLE (Port B to A) 17 14.62
54-84351SA 0.75 19.05 ANGLE (Port B to A) 24 20.64
2
Angle
50
Angle
54-84251SAB 0.50 12.7 ANGLE (Port A to B) 29 24.94
54-84431SAB 0.75 19.05 ANGLE (Port A to B) 43 36.98
54-84251SA 0.50 12.7 ANGLE (Port B to A) 24 20.64
54-84431SA 0.75 19.05 ANGLE (Port B to A) 32 27.52
1. Model descriptor SA designates an angle valve body. Model descriptor SI designates an inline valve body.
2. Tri-Clamp end connections are standard. For optional welded end connections, substitute (2) for (1) in the model number, i.e. 54-84161SA (Tri-Clamp Ends).
54-84162SA (Welded Ends).
84000 Valve
D103343X012
Product Bulletin
52.1:84000
November 2012
8
Figure 6. NPS 1 Angle and Inline Valve Body Orientations
NPS 1 ANGLE VALVE BODY POSITIONED FOR
FORWARD FLOW SELF DRAINING FROM PORT A TO B
NPS 1 INLINE VALVE BODY POSITIONED FOR
FORWARD FLOW SELF DRAINING FROM PORT A TO B
A
A
B
B
E1318
E1319
Table 8. Allowable Pressure Drops (bar): NPS 1 Angle and NPS 1 Inline Valves
VALVE
SIZE FLOW
DIREC-
TION
RATED Kv
TRAVEL ACTUATOR
TYPE
AIR-TO-OPEN ACTION AIR-TO-CLOSE ACTION
Bench
Spring
Range
Signal to Actuator
With
Positioner
(2)
Bench
Spring
Range
Signal to Actuator
With
Positioner
(2)
DN mm bar 0.2-1.0
bar
0.07-1.2
bar(1) bar bar 0.2-1.0
bar
0.07-1.2
bar(1) bar
25 AtoB
1.72 12.7 32 0.3-1.0 7.58 8.62 8.62 0.2-0.9 6.9 8.62 8.62
3.44 12.7 32 0.3-1.0 6.9 10.34 10.34 0.2-0.9 6.9 8.62 8.62
12.7 54 0.3-1.0 10.34 10.34 10.34 0.2-0.9 10.34 10.34 10.34
6.88 19.05 32 0.3-1.0 3.45 8.62 8.62 0.2-0.9 3.45 8.62 8.62
19.05 54 0.5-0.9 6.9 10.34 10.34 0.2-0.7 6.9 10.34 10.34
1. I/P transducer with 0.07 - 1.2 bar (1 - 17 psig) output signal per FCI 87.2.
2. Shutoff with positioner based on 1.4 bar (20 psi) air supply pressure.
Table 9. Allowable Pressure Drops (psi): NPS 1 Angle and NPS 1 Inline Valves
VALVE
SIZE FLOW
DIREC-
TION
RATED Cv TRAVEL ACTUATOR
TYPE
AIR-TO-OPEN ACTION AIR-TO-CLOSE ACTION
Bench
Spring
Range
Signal to Actuator
With
Positioner
(2)
Bench
Spring
Range
Signal to Actuator
With
Positioner
(2)
NPS Inches psig 3-15 psig 1-2 psig(1) psig psig 3-15 psig 1-2 psig(1) psig
1AtoB
2.00 0.50 32 5-15 110 125 125 3-13 100 125 125
4.00 0.50 32 5-15 100 150 150 3-13 100 125 125
0.50 54 5-15 150 150 150 3-13 150 150 150
8.00 0.75 32 5-15 50 125 125 3-13 50 125 125
0.75 54 7-13 100 150 150 3-10 100 150 150
1. I/P transducer with 0.07 - 1.2 bar (1 - 17 psig) output signal per FCI 87.2.
2. Shutoff with positioner based on 1.4 bar (20 psi) air supply pressure.
84000 Valve
D103343X012
Product Bulletin
52.1:84000
November 2012
9
Figure 7. NPS 1-1/2 and 2 Angle Valve Body
RECOMMENDED FOR PROCESSES WHERE ATMOSPHERIC OR
SLIGHT VACUUM IS PRESENT DOWNSTREAM OF PORT B.
(PORTS A AND B MUST BE DRAINED SEPARATELY)
A
B
E1320
Table 10. Allowable Pressure Drops (bar): Flow Direction A to B: NPS 1-1/2 and 2 Angle Valves
VALVE
SIZE FLOW
DIREC-
TION
RATED Kv
TRAVEL ACTUATOR
TYPE
AIR-TO-OPEN ACTION AIR-TO-CLOSE ACTION
Bench
Spring
Range
Signal to Actuator
With
Positioner
(2)
Bench
Spring
Range
Signal to Actuator
With
Positioner
(2)
DN mm bar 0.2-1.0
bar
0.07-1.2
bar(1) bar bar 0.2-1.0
bar
0.07-1.2
bar(1) bar
40 AtoB
18.92 12.7 54 0.3-1.0 1.99 3.99 3.99 0.2-0.9 1.99 3.99 6.96
18.92 12.7 54 0.6-1.0 4.96 6.96 6.96 0.2-0.7 4.96 6.96 9.99
25.8 19.05 54 0.3-1.0 1.99 3.99 3.99 0.2-0.9 1.99 3.99 6.96
25.8 19.05 54 0.5-0.9 3.99 5.99 5.99 0.2-0.7 4.92 6.96 9.99
50 AtoB
24.94 12.7 54 0.3-1.0 2.34 4.68 4.68 0.2-0.9 2.34 4.68 8.20
24.94 12.7 54 0.6-1.0 5.86 8.20 8.20 0.2-0.7 5.79 8.20 11.72
36.98 19.05 54 0.3-1.0 2.34 4.68 4.68 0.2-0.9 2.34 4.68 8.20
36.98 19.05 54 0.5-0.9 4.68 7.03 7.03 0.2-0.7 5.86 8.20 11.72
1. I/P transducer with 0.07 - 1.2 bar (1 - 17 psig) output signal per FCI 87.2.
2. Shutoff with positioner based on 1.4 bar (20 psi) air supply pressure.
Table 11. Allowable Pressure Drops (psi): Flow Direction A to B: NPS 1-1/2 and 2 Angle Valves
VALVE
SIZE FLOW
DIREC-
TION
RATED Cv TRAVEL ACTUATOR
TYPE
AIR-TO-OPEN ACTION AIR-TO-CLOSE ACTION
Bench
Spring
Range
Signal to Actuator
With
Positioner
(2)
Bench
Spring
Range
Signal to Actuator
With
Positioner
(2)
NPS Inches psig 3-15 psig 1-2 psig(1) psig psig 3-15 psig 1-2 psig(1) psig
1-1/2 AtoB
22 0.50 54 5-15 29 58 58 3-13 29 58 101
22 0.50 54 8-15 72 101 101 3-10 72 101 145
30 0.75 54 5-15 29 58 58 3-13 29 58 101
30 0.75 54 7-13 58 87 87 3-10 72 101 145
2AtoB
29 0.50 54 5-15 34 68 68 3-13 34 68 119
29 0.50 54 8-15 85 119 119 3-10 84 119 170
43 0.75 54 5-15 34 68 68 3-13 34 68 119
43 0.75 54 7-13 68 102 102 3-10 85 119 170
1. I/P transducer with 0.07 - 1.2 bar (1 - 17 psig) output signal per FCI 87.2.
2. Shutoff with positioner based on 1.4 bar (20 psi) air supply pressure.
84000 Valve
D103343X012
Product Bulletin
52.1:84000
November 2012
10
Figure 8. NPS 1-1/2 and 2 Angle Valve Body Positioned for Self Draining from Port B to A
E1321 A
B
Table 12. Allowable Pressure Drops (bar): Flow Direction B to A: NPS 1-1/2 and 2 Angle Valves
VALVE
SIZE FLOW
DIREC-
TION
RATED Kv
TRAVEL ACTUATOR
TYPE
AIR-TO-OPEN ACTION AIR-TO-CLOSE ACTION
Bench
Spring
Range
Signal to Actuator
With
Positioner
(2)
Bench
Spring
Range
Signal to Actuator
With
Positioner
(2)
DN mm bar 0.2-1.0
bar
0.07-1.2
bar(1) bar bar 0.2-1.0
bar
0.07-1.2
bar(1) bar
40 BtoA
14.62 12.7 54 0.3-1.0 5.10 10.20 10.20 0.2-0.9 5.10 10.20 17.86
14.62 12.7 54 0.6-1.0 12.76 17.86 17.86 0.2-0.7 12.76 17.86 25.58
20.64 19.05 54 0.3-1.0 5.10 10.20 10.20 0.2-0.9 5.10 10.20 17.86
20.64 19.05 54 0.5-0.9 10.20 15.31 15.31 0.2-0.7 12.76 17.86 25.58
50 BtoA
20.64 12.7 54 0.3-1.0 2.90 5.79 5.79 0.2-0.9 2.90 5.79 10.14
20.64 12.7 54 0.6-1.0 7.24 10.14 10.14 0.2-0.7 7.24 10.14 14.48
27.52 19.05 54 0.3-1.0 2.90 5.79 5.79 0.2-0.9 2.90 5.79 10.14
27.52 19.05 54 0.5-0.9 5.79 8.69 8.69 0.2-0.7 7.24 10.14 14.48
1. I/P transducer with 0.07 - 1.2 bar (1 - 17 psig) output signal per FCI 87.2.
2. Shutoff with positioner based on 1.4 bar (20 psi) air supply pressure.
Table 13. Allowable Pressure Drops (psi): Flow Direction B to A: NPS 1-1/2 and 2 Angle Valves
VALVE
SIZE FLOW
DIREC-
TION
RATED Cv TRAVEL ACTUATOR
TYPE
AIR-TO-OPEN ACTION AIR-TO-CLOSE ACTION
Bench
Spring
Range
Signal to Actuator
With
Positioner
(2)
Bench
Spring
Range
Signal to Actuator
With
Positioner
(2)
NPS Inches psig 3-15 psig 1-2 psig(1) psig psig 3-15 psig 1-2 psig(1) psig
1-1/2 BtoA
17 0.50 54 5-15 74 148 148 3-13 74 148 259
17 0.50 54 8-15 185 259 259 3-10 185 259 371
24 0.75 54 5-15 74 148 148 3-13 74 148 259
24 0.75 54 7-13 148 222 222 3-10 185 259 371
2BtoA
24 0.50 54 5-15 42 84 84 3-13 42 84 147
24 0.50 54 8-15 105 147 147 3-10 105 147 210
32 0.75 54 5-15 42 84 84 3-13 42 84 147
32 0.75 54 7-13 84 126 126 3-10 105 147 210
1. I/P transducer with 0.07 - 1.2 bar (1 - 17 psig) output signal per FCI 87.2.
2. Shutoff with positioner based on 1.4 bar (20 psi) air supply pressure.
84000 Valve
D103343X012
Product Bulletin
52.1:84000
November 2012
11
Figure 9. Dimensional Drawings for Baumann84000NPS1AngleandInlineValves
E1322
216 (48.5)
249 (9.8)
BAUMANN 32 ACTUATOR WITH
FIELDVUE DVC2000, TOP VIEW
216 (48.5)
31 (1.24)
227
(9.0)
85
(3.4)
32
(1.3) 148
(5.8)
166
(6.52)
127
(5.00)
85
(3.4)
84
(3.3)
40
(1.6)
84000 ANGLE VALVE BODY WITH
BAUMANN 32 ACTUATOR ATC/FO
ACTION, DUAL STOP AND FIELDVUE
DVC2000 DIGITAL VALVE CONTROLLER
84000 INLINE VALVE BODY WITH BAUMANN
32 ACTUATOR ATC/FC ACTION, DUAL STOP
AND 3660/3661 POSITIONER
mm
(inch)
Table14.ValveAssemblyandActuatorWeights
VALVE SIZE 84000 ANGLE ASSEMBLY 84000 IN-LINE ASSEMBLY ACTUATOR WEIGHTS
DN NPS kgs lbs kgs lbs TYPE kgs lbs
25 14.06 9.0 4.31 9.5 32 4.5 10
40 1-1/2 5.22 11.5 N/A 54 11.3 25
50 25.22 11.5 N/A
84000 Valve
D103343X012
Product Bulletin
52.1:84000
November 2012
12
Figure 10. Dimensional Drawing for Baumann 84000 NPS 1-1/2 and 2 Angle Valve with FIELDVUE DVC6010 Digital
Valve Controller
Note: Actuator removal requires 115mm (4.5 inches) vertical clearance.
E1323
279 (411.0)
359 (14.5)
276
(10.9)
mm
(inch)
C
D
E
FG
Table15.ValveAssemblyandActuatorWeights
VALVE SIZE C D E F G
DN NPS mm inch mm inch mm inch mm inch mm inch
40 1-1/2 152.4 6.0 50.8 2.00 82.55 3.25 50.39 1.984 34.44 1.356
50 2160 6.3 50.8 2.00 88.9 3.50 63.9 2.516 47.63 1.875
Emerson Process Management
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they arenot
to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
E2009, 2012 Fisher Controls International LLC. All rights reserved.
Baumann, Fisher, FIELDVUE, and PlantWeb are marks owned by one of the companies in the Emerson Process Management business unit of Emerson
Electric Co. Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are
the property of their respective owners.
Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance
of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Page 1 of 12 - Emerson Emerson-Fisher-Baumann-84000-Data-Sheet-  Emerson-fisher-baumann-84000-data-sheet
Page 2 of 12 - Emerson Emerson-Fisher-Baumann-84000-Data-Sheet-  Emerson-fisher-baumann-84000-data-sheet
Page 3 of 12 - Emerson Emerson-Fisher-Baumann-84000-Data-Sheet-  Emerson-fisher-baumann-84000-data-sheet
Page 4 of 12 - Emerson Emerson-Fisher-Baumann-84000-Data-Sheet-  Emerson-fisher-baumann-84000-data-sheet
Page 5 of 12 - Emerson Emerson-Fisher-Baumann-84000-Data-Sheet-  Emerson-fisher-baumann-84000-data-sheet
Page 6 of 12 - Emerson Emerson-Fisher-Baumann-84000-Data-Sheet-  Emerson-fisher-baumann-84000-data-sheet
Page 7 of 12 - Emerson Emerson-Fisher-Baumann-84000-Data-Sheet-  Emerson-fisher-baumann-84000-data-sheet
Page 8 of 12 - Emerson Emerson-Fisher-Baumann-84000-Data-Sheet-  Emerson-fisher-baumann-84000-data-sheet
Page 9 of 12 - Emerson Emerson-Fisher-Baumann-84000-Data-Sheet-  Emerson-fisher-baumann-84000-data-sheet
Page 10 of 12 - Emerson Emerson-Fisher-Baumann-84000-Data-Sheet-  Emerson-fisher-baumann-84000-data-sheet
Page 11 of 12 - Emerson Emerson-Fisher-Baumann-84000-Data-Sheet-  Emerson-fisher-baumann-84000-data-sheet
Page 12 of 12 - Emerson Emerson-Fisher-Baumann-84000-Data-Sheet-  Emerson-fisher-baumann-84000-data-sheet

Navigation menu