Fisher easy-Drive Electric Actuators
®

™

Low Power, High Reliability

Fisher easy-Drive Electric Actuators
®

™

Fisher D4 valve with
easy-Drive electric actuator

Environmental Stewardship

Fisher® easy-Drive™ electric actuators are specifically designed
for upstream natural gas applications. They can be installed
on Fisher D4 or D3 valves and give you the ability to use
proven, robust, globe valve technology while protecting the
environment from methane gas venting.

Fisher D3 valve with
easy-Drive electric actuator

Benefits

n No venting of product to atmosphere.
n Eliminates maintenance issues arising from wet

or dirty well gas.
n Highly responsive—valve strokes from fully open

to fully closed in less than five seconds.
n Easy to commission. Calibrate by opening and

Improved Reliability

Gas quality is not always consistent and particulates can be
a maintenance problem for pneumatic actuators. Electric
actuators avoid this maintenance issue.

Improved Profitability

Traditionally, valves and instrumentation in natural gas
applications have been powered by the pressure of the gas
itself. This means that gas must be vented to atmosphere—the
same gas that would be otherwise sold.

Technical

Fisher easy-Drive electric actuator specifications include low
energy requirements of 12 or 24VDC operation, maximum
current draw of 3.5A when moving, and an at-rest power draw
below 1W. The control signal can be Modbus RTU (RS-485),
4-20 mA, 1-5V, or dry contact, configurable within the Modbus
registers. Operating temperature range is -20°C to 70°C
(-4°F to 158°F.)
The easy-Drive electric actuator can control pressures up
to 4250 psi on the D4 valve and maintain a Class IV shutoff
indefinitely without power.

closing—no switches to set.
n No power is required to maintain shutoff. The unit

can be disconnected and seat load will remain.
n Easy to use.
n Diagnostics available over Modbus.

Complete Electric Wellhead
from Emerson Process Management

Fully integrated and supported electric wellhead
solutions are available from your local Emerson
sales office.
n Fisher electric level solution—easy-Drive electric

actuator and L2e electric level controller
n ROC, FloBoss,™ and ControlWave RTUs and

flow computers
n Rosemount™ pressure, level, and

temperature sensors
n Daniel™ and Micro Motion™ flow meters

is exactly what we are looking
“Tforheoneasy-Drive
our wells with dirty and wet gas.
”
- HSE manager, Natural Gas Producer

Yellow and green represent responsible natural gas control backed by Fisher product reliability.

Flexible Control
Modbus RTU (RS-485),
4-20mA, 1-5V, or dry contact.
Ease of Use
Calibrate by opening and
closing. No switches to set.
Low Power Consumption
Capable of being operated
from solar charged battery
systems at 12 or 24VDC.
Reliable Brushless DC Motor
Motor and controls are
designed for remote field
operation.
Sealed Gearbox
The permanently lubricated
gearbox eliminates the need
for cleaning and regreasing.
Explosion-Proof Housing
Approved for Class I, Division 1,
Groups C, D (Zone 1, IIA EXd,
ATEX). IP66/NEMA 4X.
Field-Selectable Flow Rates
FloPro feature allows field
adjustment of capacity without
changing the trim on D3 valve.
Easy and Safe Maintenance
Deep-bore hammer nut for
easy removal of actuator/
bonnet assembly to access
the plug and seat. Maintains
thread engagement until
after process boundary is
broken for user safety.
Excellent Emissions Control
ENVIRO-SEAL™ packing
technology provides an
improved stem seal to
minimize fugitive emissions.

If you found this brochure valuable,
may we also recommend the following:
“Fisher® L2e Electric Level Controller”

“Fisher® FIELDVUE™ DVC6000 Natural
Gas Certified: Integrated Primary
Process Seal”

“Fisher® C1 Pneumatic Controller:
Reduces Energy Use, Increases Profits”

“Fisher® i2P-100 Electro-Pneumatic
Transducer: For Safer Operations
and Improved Up-Time”

“Earn More Revenue from
Natural Gas Production”

YOUTUBE LOGO SPECS

PRINT
main red

gradient bottom

C0 M96 Y90 K2

C13 M96 Y81 K54

white

black

C0 M0 Y0 K0

C100 M100 Y100 K100

PMS 1795C

WHITE

on light backgrounds

on dark backgrounds

standard

standard

no gradients

no gradients

watermark

watermark

PMS 1815C

BLACK

stacked logo (for sharing only)

stacked logo (for sharing only)

http://www.Facebook.com/FisherValves

http://www.YouTube.com/user/FisherControlValve

http://www.Twitter.com/FisherValves

http://www.LinkedIn.com/groups/Fisher-3941826

To find the
Emerson sales
contact in
your area, scan
this code.

© 2010, 2013 Fisher Controls International LLC. All rights reserved.
Fisher, easy-Drive, FloBoss, Rosemount, Daniel, Micro Motion, ENVIRO-SEAL, and FIELDVUE are marks
owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co.
Emerson Process Management, Emerson, and the Emerson logo are trademarks and service marks of
Emerson Electric Co. All other marks are the property of their respective owners.
Emerson Process Management
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore
www.Fisher.com

D351901X012 / MZ79 / Apr13

The contents of this publication are presented for informational purposes only, and while every
effort has been made to ensure their accuracy, nothing herein is to be construed as a warranty
or guarantee, express or implied, regarding the products or services described herein or their
use, performance, merchantability or fitness for a particular purpose. Individual results may vary.
All sales are governed by our terms and conditions, which are available upon request. We reserve
the right to modify or improve the designs or specifications of our products at any time without
notice. Responsibility for proper selection, use and maintenance of any product or service remains
solely with the purchaser and end user.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Page Count                      : 4
Page Layout                     : TwoColumnRight
XMP Toolkit                     : XMP toolkit 3.0-28, framework 1.6
About                           : uuid:22612b7f-0656-46aa-b8d1-37e42d462bbe
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Create Date                     : 2013:04:02 15:31:16-05:00
Modify Date                     : 2013:04:18 12:06:47-05:00
Metadata Date                   : 2013:04:18 12:06:47-05:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Original Document ID            : adobe:docid:indd:9efbecba-1269-11de-a70a-8c14f7291d5c
Document ID                     : xmp.id:634F42C7D29BE2119AAE86CCC544FC69
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:681240A5D29BE2119AAE86CCC544FC69
Derived From Document ID        : xmp.did:6B568DD4AF9BE211884C83ADBA8A5E89
Derived From Original Document ID: adobe:docid:indd:9efbecba-1269-11de-a70a-8c14f7291d5c
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2013:04:02 15:31:16-05:00
Instance ID                     : uuid:22612b7f-0656-46aa-b8d1-37e42d462bbe
Format                          : application/pdf
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu