Instruction Manual

V260 Valve

D102178X012

September 2012

Fisherr V260 Rotary Pipeline Ball Valve
Contents

Figure 1. Fisher V260 Sectional View

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Scope of Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Packing Maintenance . . . . . . . . . . . . . . . . . . . . . . . . 5
Stopping Leakage . . . . . . . . . . . . . . . . . . . . . . . . 5
Replacing Packing . . . . . . . . . . . . . . . . . . . . . . . . 5
Seal Ring Maintenance
Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Actuator Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Determining Mounting Position . . . . . . . . . . . . . . . 12
Determining Closed Position . . . . . . . . . . . . . . . . . 12
Parts Ordering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

W6365-2

Introduction
Scope of Manual
This instruction manual provides installation, operation, maintenance, and parts information for the Fisher V260
control valve. Refer to separate manuals for information concerning the actuator, positioner, and accessories (see
figure 1).
Do not install, operate, or maintain a V260 valve without being fully trained and qualified in valve, actuator, and
accessory installation, operation, and maintenance. To avoid personal injury or property damage, it is important to
carefully read, understand, and follow all the contents of this manual, including all safety cautions and warnings. If you
have any questions about these instructions, contact your Emerson Process Management sales office before
proceeding.

Description
V260 throttling ball valves are available in single-seal, double block-and-bleed, dual-seal, and bidirectional flow
constructions with or without attenuators. Valves with dome-style attenuators combine the efficiency of a rotary valve
with the noise reducing capability of a special trim (figure 4). Valves without attenuators present little or no restriction
to flow at full travel.

www.Fisher.com

Instruction Manual

V260 Valve
September 2012

D102178X012

Table 1. Specifications
Valve Body Size and End Connection Styles(1)
NPS 8, 10, 12, 16, 20, and 24 flanged valves with
CL150, CL300, and CL600 raised-face or ring-type
joint flanges compatible with ASME B16.5. See table 2
for face-to-face dimensions. Consult factory for other
pressure ratings.
Maximum Inlet Pressures and Temperatures(1)
Consistent with CL150, CL300, and CL600
pressure-temperature ratings per ASME B16.34
Maximum Allowable Shutoff Pressure Drop(1)
For Single-Seal and Dual-Seal Construction:
(Except where further limited by the
pressure-temperature rating of valve body material)
For LF2 valve body material:
CL150: 19.6 bar (285 psi) at 38_C (100_F)
CL300: 51 bar (740 psi) at 38_C (100_F)
CL600: 103 bar (1480 psi) at 38_C (100_F)
Seal Material and Temperature Capability(1)
J POM (polyoxymethylene) (Standard) -29 to 82_C
(-20 to 180_F)
J PTFE/PEEK(2)(3) (Optional) -29 to 93_C (-20 to
200_F)
Flow Characteristic
Modified equal percentage

Flow and Shutoff Direction
Unidirectional flow for Fisher V260 is forward flow.
Seal is upstream.
J Single Seal Constructions: Should be used for
unidirectional flow and unidirectional shutoff only.
J Dual Seal Constructions: V260A and V260C may be
used for unidirectional or bidirectional flow. V260B
should be used for unidirectional flow only for most
effective anti-cavitation protection. Bidirectional
shutoff requires the dual seal construction.
Shutoff Classification
Single-Seal Composition Constructions: 0.001% of
maximum valve capacity (less than 10% of ANSI/FCI
70-2 Class IV and IEC 60534-4)
Dual-Seal Composition Constructions: 0.001% of
maximum valve capacity (less than 10% of ANSI/FCI
70-2 Class IV and IEC 60534-4)
Maximum Ball Rotation
90 degrees
Actuator Mounting
Right-hand or left-hand mounted as viewed from the
valve inlet for forward flow
Approximate Weight
See table 2

1. The pressure-temperature limits in this instruction manual and any applicable standard or code limitation for valve should not be exceeded.
2. PTFE stands for Polytetrafluorethylene, and PEEK stands for Polyetheretherketone.
3. Temperature limits of PTFE/PEEK is limited due to standard nitrile O-ring. Contact your Emerson Process Management sales office for higher temperature options, up to 232_C (450_F).

Installation
WARNING
D To avoid personal injury, always wear protective gloves, clothing, and eyewear when performing any installation
operations.
D To avoid personal injury or property damage resulting from the bursting of pressure retaining parts, be certain the
service conditions do not exceed the limits given in this manual.
D To avoid personal injury or property damage that can result from the sudden release of process pressure if valve or
mating pipe flange pressure ratings are exceeded, provide a relief valve for over-pressure protection as required by
government or accepted industry codes and good engineering practices.
D Service conditions are limited for valve and trim material combinations. Do not apply any other service condition to the
valve without first contacting your Emerson Process Management sales office.
D Personal injury could result from packing leakage. The valve packing was tightened before shipment however, the
packing might require some readjustment to meet specific service conditions.

2

Instruction Manual

V260 Valve

D102178X012

September 2012

D Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
D If installing into an existing application, also refer to the WARNING at the beginning of the Maintenance section in this
instruction manual.
D To avoid personal injury or property damage, a minimum of two swivel hoists must be used when lifting NPS 24 CL600
assemblies.

Table 2. Face-to-Face Dimensions and Approximate Weights
VALVE SIZE, NPS
(CL600(1))

FACE-TO-FACE
DIMENSIONS

APPROXIMATE WEIGHT

mm

kg

8

661

424

10

788

653

12

840

882

16

990.6

2472

20

1144

4313

24

1397

7257

Inches

Pounds

8

26.04

975

10

31.04

1550

12

33.07

2025

16

39.0

5450

20

47.0

9500

24

55.0

16000

1. For CL150 and CL300 valves, face-to-face dimensions are the same as CL600 valves.

Key number locations are shown in figure 6, unless otherwise noted.
1. Install a three-valve bypass around the control valve assembly if continuous operation will be necessary during
inspection and maintenance of the valve.
2. The valve is normally shipped as part of a control valve assembly, with an actuator mounted on the valve. The
valve/actuator assembly is adjusted at the factory before the unit is shipped.
If the valve or actuator has been purchased separately or if the actuator has been removed, mount the actuator
according to the Actuator Mounting section and the appropriate actuator instruction manual. Make any necessary
adjustments on the bench before installing the valve in the pipeline. With the valve in the pipeline, you cannot see the
exact position of the ball to determine the fully open or closed positions.
3. Standard flow direction is shown in figure 6. If possible, install the valve in a horizontal pipeline with the drive shaft
horizontal. The actuator can be right- or left-hand mounted in any of the positions shown in the actuator instruction
manual. If necessary, refer to the appropriate actuator instruction manual for installation and adjustment
procedures.
4. Be certain the valve and adjacent pipelines are free of any foreign material that could damage the valve sealing
surfaces. Impurities or entrained solids in the process fluid could plug the passages in the trim. If the process fluid is
not clean, install a filter upstream to keep the pipeline free of impurities or entrained solids.
5. Provide appropriate flange gaskets, and place the valve in the pipeline. Tighten flange bolting in a criss-cross
sequence to ensure the flange gaskets are loaded evenly.

3

Instruction Manual

V260 Valve
September 2012

D102178X012

Note
Standard Fisher V260 valve packings (key 105) are composed of:
D Conductive packing ring (graphite ribbon packing), or
D Partially conductive packing rings (For example: a carbon-filled PTFE female adaptor with PTFE V-ring packing or a
graphite-composition packing ring with PTFE/composition packing ring)
In order to electrically bond the drive shaft to the valve body for hazardous area service, an alternate shaft-to-body bonding strap
can be provided by using the following step.

Figure 2. Optional Shaft-to-Body Bonding Strap Assembly
VALVE BODY

37A6528-A
A3143-2

VIEW A-A

ACTUATOR
A

A

6. For hazardous applications, attach the optional bonding strap assembly (key 131) to the valve drive shaft (key 6)
with the clamp (key 130) and connect the other end of the bonding strap assembly to the valve body with the
mounting cap screw as shown in figure 2.
7. Connect pressure lines to the actuator as indicated in the actuator instruction manual. When an auxiliary manual
actuator is used with a power actuator, install a bypass valve on the power actuator (if one is not supplied) for use
during manual operation.
8. If the valve has ENVIRO-SEAL™ live-loaded packing installed, an initial re-adjustment may not be required,
depending on your application. See the Fisher instruction manual titled ENVIRO-SEAL Packing System for Rotary
Valves, D101643X012, for packing instructions and adjustments (see figure 3).

Maintenance
Valve parts are subject to normal wear and must be inspected and replaced as necessary. The frequency of inspection
and replacement depends upon the severity of service conditions.
Key numbers are shown in figure 6, unless otherwise noted.

WARNING
Avoid personal injury or equipment damage from sudden release of process pressure or uncontrolled movement of parts.
Before performing any maintenance operations:

4

Instruction Manual
D102178X012

V260 Valve
September 2012

D Do not remove the actuator from the valve while the valve is still pressurized.
D Always wear protective gloves, clothing, and eyewear when performing any maintenance operations to avoid personal
injury.
D Disconnect any operating lines providing air pressure, electric power, or a control signal to the actuator. Be sure the
actuator cannot suddenly open or close the valve.
D Vent the power actuator loading pressure and relieve any actuator spring precompression.
D Use bypass valves or completely shut off the process to isolate the valve from process pressure. Relieve process pressure
from both sides of the valve. Drain the process media from both sides of the valve.
D Dual-seal valve constructions can retain pressure and process fluid even after process pressure has been removed from
both sides of the valve. Relieve this pressure before disassembling or removing the valve from the line. Take additional
care if the process fluid is hot, flammable, caustic, or hazardous.
D Carefully secure the valve in an upright position. The roundness of the flanges and valve body allow it to easily roll from
side-to-side. The combined weight of the valve/actuator assembly could cause injury or property damage when falling
to the side.
D Use lock-out procedures to be sure that the above measures stay in effect while you work on the equipment.
D The valve packing box may contain process fluids that are pressurized, even when the valve has been removed from the
pipeline. Process fluids may spray out under pressure when removing the packing hardware or packing rings, or when
loosening the packing box pipe plug.
D Avoid injury by keeping hands, tools, and other objects away from the ball while stroking the valve.
D Check with your process or safety engineer for any additional measures that must be taken to protect against process
media.
D To avoid personal injury or property damage, a minimum of two swivel hoists must be used when lifting NPS 24 CL600
assemblies.

Packing Maintenance
Note
For the ENVIRO-SEAL Packing System, refer to the separate ENVIRO-SEAL Packing System for Rotary Valves instruction manual,
D101643X012, for maintenance instructions.

Stopping Leakage
For standard PTFE V-ring packing, leakage around the packing follower may be stopped by tightening the packing
follower nuts.
If the packing is relatively new and tight on the drive shaft, and if tightening the packing follower nuts does not stop
the leakage, the drive shaft may be worn or nicked so that a seal cannot be made. If the leakage comes from the
outside diameter of the packing, the leakage may be caused by nicks or scratches on the packing box wall. Inspect the
drive shaft and packing box wall for nicks or scratches while performing the following procedure.

Replacing Packing
Replacing the packing requires bleeding off the system and removing the actuator from the valve. Valve/actuator
adjustments cannot be made correctly without observing the fully open or closed position of the ball (key 11). It is not
necessary to remove the valve from the pipeline, if care is taken to note the position and alignment of the lever and
shaft and to not disturb the turnbuckle position.

5

Instruction Manual

V260 Valve
September 2012

D102178X012

Figure 3. Packing Arrangement Details
DRIVE SHAFT
(KEY 20)

PACKING STUD
AND NUT
(KEYS 100 AND 101)

PACKING FLANGE
(KEY 102)
PACKING
FOLLOWER
(KEY 114)

TYPICAL PTFE
V-RING PACKING
SET (KEY 105)

TYPICAL
ENVIRO-SEAL
PTFE V-RING
PACKING SET

PACKING BOX
RING (KEY 107)

94BA02200-D
B2472-1

STANDARD
ENVIRO-SEAL
PACKING ARRANGEMENT PACKING ARRANGEMENT

Disassembly
1. Isolate the control valve from the line pressure, release pressure from both sides of the valve body, and drain the
process media from both sides of the valve. If using a power actuator, shut off all pressure lines (or other power
source) to the power actuator, release pressure from the actuator, and disconnect the pressure lines from the
actuator. Use lock-out procedures to be sure that the above measures stay in effect while you work on the
equipment.
See the WARNING at the beginning of the Maintenance section for more information before removing the valve from
the pipeline.
2. Remove line bolting, remove the control valve from the pipeline, and place the actuator/valve assembly on a flat
surface.
3. Remove the actuator cover. Note and mark the orientation of the actuator with respect to the valve body and the
lever orientation with respect to the valve drive shaft, to assist with reassembly.
4. Loosen the lever locking device cap screw. Loosening the lever turnbuckle adjustment is not necessary during
disassembly. When remounting the actuator, the turnbuckle will be used for actuator adjustments.
5. Removing the actuator from the valve:
a. Remove the actuator mounting screws, bolts, or nuts.

CAUTION
When removing the actuator from the valve, do not use a hammer or similar tool to drive the lever or actuator off the valve
shaft. Driving the lever or actuator off the valve shaft could damage the ball, seal(s), and valve.
If necessary, use a wheel puller to remove the lever or actuator from the valve shaft. Tap the wheel puller screw lightly to
loosen the lever or actuator. Do not hit the screw with excessive force. Using excessive force could damage the ball, seal(s),
and valve.

6

Instruction Manual
D102178X012

V260 Valve
September 2012

b. Slide the lever along the valve shaft while removing the actuator from the valve.
6. If necessary, remove the bonding strap assembly, shown in figure 2, from the valve before attempting to remove
the packing box parts.
7. Remove the packing follower nuts, packing flange, and packing follower (keys 101, 102, and 114, figure 3).
8. Remove the packing parts:
a. If the packing housing (key 16) is mounted on the valve: Use a formed wire hook with a sharp end to pierce the
packing rings, and pull the rings out of the packing box. Do not scratch the drive shaft or packing box wall.
Scratching these surfaces could cause leakage. Clean, inspect, and obtain replacement parts as necessary for
reassembly.
b. If the packing housing is removed from the valve: Remove the drive shaft (key 20) from the packing housing.
With the drive shaft removed, remove all internal parts. Clean, inspect, and obtain replacement parts as
necessary for reassembly.
The packing sets (key 105) listed in the parts list do not include any metal parts. Either clean and reuse metal packing
parts or obtain replacements by ordering them individually.

Assembly
If the valve is equipped with the ENVIRO-SEAL packing system, refer to the ENVIRO-SEAL Packing System Rotary Valves
instruction manual for assembly.
1. If the packing housing assembly (key16) is removed from the valve, use the valve assembly steps to reinstall the
drive shaft (key 20) and packing housing assembly on the valve.
2. For standard packing arrangements, install the new packing parts using the parts sequence shown in figure 3.
3. Secure the packing follower and packing flange with the packing nuts (keys 114, 102, and 101). Tighten the nuts far
enough to stop leakage during operating conditions.
4. If necessary, install the bonding strap assembly shown in figure 2.
5. Use the steps provided in the Actuator Mounting section to install the actuator on the valve. For actuator travel
adjustments, refer to the appropriate actuator instruction manual.
6. When the control valve is installed in the pipeline and in operation, check around the packing follower for leakage
and retighten the packing nuts as necessary.

Seal Ring Maintenance
Disassembly
WARNING
For valves with dual-seals, fluid and/or a hazardous material may be trapped under pressure in the valve body cavity. To
avoid personal injury, relieve the pressure, and drain any remaining fluid or hazardous material from the valve body cavity.
If necessary, disassemble the valve in a safe area for cleaning.
See the WARNING at the beginning of the Maintenance section for more information before removing the valve from the
pipeline.

Disassemble the valve only to the extent necessary to accomplish the needed inspection and repairs. For some repairs
(for example, the trim parts only) complete disassembly of the valve is not necessary. Follow the disassembly

7

V260 Valve

Instruction Manual

September 2012

D102178X012

procedures to the point necessary to accomplish the repair, then skip to the appropriate assembly steps to complete
the reassembly of the valve. Always clean and protect sealing surfaces from damage.
Mark parts as necessary to allow them to be returned to the same position as removed. For example: Be sure to return
the tailpiece to the same end of the valve from which it was removed. Also, the seal assembly within the tailpiece
should be returned to the same tailpiece from which it was removed. The bearing plates should be marked and
reinstalled on the ball in the same position as they were, when removed.
1. Isolate the control valve from the line pressure, release pressure from both sides of the valve body, and drain the
process media from both sides of the valve. If using a power actuator, shut off all pressure lines to the power
actuator, release pressure from the actuator, and disconnect the pressure lines from the actuator. Use lock-out
procedures to be sure that the above measures stay in effect while you work on the equipment.
2. Remove line bolting, remove the control valve from the pipeline, and clean all valve surfaces. Place the
actuator/valve assembly on a flat working surface.
3. Mark parts as necessary to allow them to be returned to the same position during re-assembly.
4. Perform the procedure in the Packing Maintenance section to remove the actuator from the valve. When valve
maintenance is complete, refer to the Mounting Actuator procedure at the end of the Maintenance section to
re-install the actuator on the valve.
5. Provide a clean soft working surface to protect the tailpiece-flange sealing surface.
a. If the valve does not have an attenuator dome, lift the valve and place it on its side with either tailpiece flange
resting on the flat surface. Be sure the valve is in a stable, upright position before releasing the hoist connection.
b. If the valve has a single attenuator dome, it is best to position the valve body so the tailpiece with the dome is in
the down position. Be sure the valve is stable, in an upward position before releasing the hoist connection.

Note
If the packing is in good condition, it is possible to remove and replace the seal assembly, or dome assembly without removing the
packing box assembly. However, the packing assembly must be removed to remove the ball (key 11) from the valve body.

6. Remove the packing housing nuts (key 23). Remove the packing housing assembly from the valve. The assembly
includes all the packing box parts, drive shaft, O-ring seals, bearing, and other parts.
7. Remove the nuts from the studs (keys 19 and 3) to remove the tailpiece/valve connection. (Refer to figure 6).

Note
While lifting the tailpiece (key 2 or 6) from the valve body, check to see if the seal assembly is lifting with the tailpiece. (Note:
Some valve constructions do not have a seal assembly installed in the tailpiece.) If it is, slide something between the ball and
tailpiece to protect the ball in case the seal assembly falls out of the tailpiece.

8. If the valve has dual attenuator domes, tap the dome to loosen it from the top tailpiece before the top tailpiece is
lifted from the valve body.
9. Turn the tailpiece over so the seal assembly is facing up, and place it on a clean soft surface with the flange face
down.
10. From the tailpiece assembly or from the valve, remove the seal assembly, wave spring, and O-ring seal (keys 8 and
7). Clean and protect all sealing surfaces.

8

Instruction Manual
D102178X012

V260 Valve
September 2012

WARNING
In the next step, be sure to secure the bearing plates on the ball to prevent them from falling. When lifting the ball, the
bearing plates may slide-off the ball trunnions which may cause personal injury or property damage.

11. Turn the ball (key 11) to the closed position. Use a nylon sling through the ball bore to lift the ball out of the valve
body. Lift the ball and set it on a clean soft surface.
12. Remove the two bearing plates and thrust washers (key 4 and 30) from the ball (key 11). Inspect the bearing in the
bearing plates and thrust washers (keys 29 and 30). If necessary, remove and replace the bearings (key 29).
13. Evenly loosen the hex nuts from the studs on the lower tailpiece (key 2 or 6). Remove the valve body from the
tailpiece.
14. Remove from the tailpiece assembly, the dome assembly and/or the seal assembly, wave spring, and O-ring seal.
Clean and protect all sealing surfaces.

Assembly
Be sure to replace valve parts in the same position that they were removed. Use the following suggested sequence to
reassemble the valve.

Note
Clean and protect all sealing surfaces from damage while installing parts. Lubricate parts when necessary as an aid for installing
parts, and to help protect sealing surfaces.

Key number locations are shown in figure 6.
1. Place the tailpiece (key 2 or 6), pipe flange end down on a clean soft surface with the seal assembly or attenuator
dome cavity facing up.
2. Lubricate and install the O-rings (key 12) on both tailpieces.
For characterized domes, install the grooved end of the dome groove pin (key 33) into the tailpiece, as far as it will go.
Use only a light tapping force, taking care not to bend the pin. This groove pin will prevent the attenuator dome from
rotating with respect to the tailpiece.
3. Install the inlet end attenuator dome (key 28 or 10) into the tailpiece (key 6). Use the lifting lugs in the two
threaded holes for ease of handling.
For characterized attenuators, align the pin hole in the dome with the groove pin (key 33) placed in the tailpiece in
step 3. High Density attenuators don't require this orientation.
For dual seal V260A or V260B constructions, lubricate and install the O-ring (key 15) on the dome spacer (key 13). If a
dual dome is being assembled, install the dome spacer into the tailpiece, using the two threaded holes as lifting lugs.
4. Apply thread locking adhesive to and install the two cap screws (key 36) that hold the washers (key 37) which help
retain the dome or dome spacer (if applicable) in the tailpiece.
For constructions with dual dome and/or dual seals, lubricate and install the O-ring (key 7) in the groove on the inlet
seal (key 9). Install the wave spring (key 8) over the end of the seal. Install the seal assembly O-ring (key 7) between the
dome spacer and the dome (key 10).

Note
D Verify that the ball opens into the dome windows last. (See figure 5)

9

V260 Valve

Instruction Manual

September 2012

D102178X012

D If not, remove the dome and tailpiece and turn it 180 degrees to allow the windows to open last.

5. Install the grooved end of the groove pins (key 5) into the bearing plates (key 4) as far as they will go. Use only a
light tapping force, taking care not to bend the pins.
6. Apply dry film lubrication between the trunnion surfaces on the ball and the trunnion bearings.
7. Install new bearings (key 29) in the bearing plates (key 4).

WARNING
In the next step, be sure to secure the bearing plates on the ball to prevent them from falling. When lifting the ball, the
bearing plates may slide off the ball trunnions which may cause personal injury or property damage.

8. Lift the ball with a nylon sling through the bore and turn the ball until the port and trunnions are horizontal.
9. Slide one ball thrust washer (key 30) onto each side of the ball trunnions, and install a bearing plate (key 4) on each
side of the ball trunnions.
10. Carefully lower the ball and bearing plates onto the lower (inlet) tailpiece taking care not to damage the ball
surface.
While lowering the ball, guide the groove pins in the bearing plates into their proper location in the tailpiece. To
determine the proper location for Right Hand Mounting, turn the splined trunnion so that it is on your right hand side
when the attenuator dome is in front of you and the bottom of the valve is nearest you.
11. Install the grooved end of the groove pin (key 18) into the valve body, as far as it will go. Use only a light tapping
force, taking care not to bend the pin. Install the body studs (key 3) in the valve body and install two swivel hoists for
lifting the valve body.
12. Lift the valve body, using the swivel hoists, so it is centered over the ball and bearing plates. Be sure the shaft hole
is aligned with the splined trunnion on the ball. When lowering the valve body, take care not to damage the ball.
Guide the groove pins in the valve body into their proper location in the tailpiece.
13. Install the hex nuts(key 19) on the studs (key 3) and hand-tighten them.
14. Lubricate and install the O-ring (key 14) on the packing housing (key 16). Install the shaft bearing (key 32) in the
packing box housing.
15. Install the packing housing studs (key 22) in the valve body.
16. Apply anti-seize lubricant to the large spline on the shaft. Line-up the missing spIine tooth with the appropriate
space in the ball, and install the drive shaft (key 20) into the ball.
17. Install the shaft thrust washer (key 24) onto the shaft.
18. Install the packing housing (key 16) and nuts (key 23), and tighten them evenly. Orient the length of the packing
box housing perpendicular to the bore of the valve body.

WARNING
Refer to table 3 for bolt torque requirements. Exceeding any torque requirements could damage the valve and impair safe
operation.

10

Instruction Manual

V260 Valve

D102178X012

September 2012

Table 3. Torque Values
VALVE SIZE, NPS

8

10

12

16

20

24

VALVE BODY HEX NUT (KEY 19)

PRESSURE
RATING

NSm

lbf-ft

CL150

393

290

CL300

549

405

CL600

746

550

CL150

549

405

CL300

746

550

CL600

990

730

CL150

549

405

CL300

990

730

CL600

990

730

CL150

746

550

CL300

1750

1290

CL600

1750

1290

MOUNTING FLANGE HEX NUT (KEY 23)
NSm

lbf-ft

271

200

746

550

990

730
730

CL150

990

730

CL300

2237

1650

CL600

3470

2560

CL150

1749

1290

990

CL300

3470

2560

990

730

CL600

6088

4490

1749

1290

19. Assemble the seal and install the second tailpiece using the following steps.
For dual seal and dual dome constructions, it is easier to lay the valve assembly on its side while installing the second
tailpiece.
20. Install the dome, dome spacer, and alignment groove pins (if a characterized attenuator is used) in the tailpiece.
21. Lubricate and install the seal assembly O-ring (key 7) in the groove of the seal as shown in figure 6.
22. Install the wave spring (key 8) over the end of the seal (key 17 or 9). Note that the spring is not required with the
attenuator dome (key 28, figure 6).
23. For single seal constructions, place the seal ring assembly into the tailpiece, taking care not to damage the O-ring
(key 7) while sliding it into the tailpiece. Also, be careful to protect all sealing surfaces.
For dual seal constructions, place the seal assembly (key 17) into the dome, dome spacer and tailpiece.
24. Lift the second tailpiece assembly and align it with the valve body studs and pins. Slide the tailpiece onto the studs
and bearing plate pins. The groove pins in the valve body should be guided into the pin holes in the tailpiece. Pull it
up tightly, taking care not to damage the tailpiece O-ring as it is pulled into the valve body.
25. Install the hex nuts (key 19) on the studs (key 3) and hand-tighten them. Torque all the hex nuts evenly.

WARNING
Refer to table 3 for bolt torque requirements. Exceeding any torque requirements could damage the valve and impair safe
operation.

26. Refer to the Packing Maintenance section to install the packing parts.

Actuator Mounting
Use the appropriate actuator instruction manual when mounting the actuator or changing actuator styles and
positions.

11

V260 Valve
September 2012

Instruction Manual
D102178X012

Determining Mounting Position
The actuator can be either right- or left-hand mounted.

Note
D Right-hand mounting means that the actuator is mounted on the right side of the valve when viewed from the valve inlet.
D Left-hand mounting means that the actuator is mounted on the left side of the valve when viewed from the valve inlet.

Right- or left-hand mounting can change the actuator action from push-down-to-close to push-down-to-open, or
vice-versa.

Determining Closed Position
1. You must remove the valve from the pipeline to check the position of the ball.
2. Adjust the actuator linkage or travel stops as described in the actuator instruction manual. Adjust the actuator so
that the valve ball will be fully open or closed when the actuator is at the end of its stroke, depending on the
actuator action selected.

Parts Ordering
A serial number is assigned to each valve and stamped on the nameplate. Always refer to the valve serial number when
corresponding with your Emerson Process Management sales office regarding spare parts or technical information.
When ordering replacement parts, also specify the part name and desired material.

WARNING
Use only genuine Fisher replacement parts. Components that are not supplied by Emerson Process Management should
not, under any circumstances, be used in any Fisher valve, because they may void your warranty, might adversely affect the
performance of the valve, and could cause personal injury and property damage.

12

Instruction Manual

V260 Valve

D102178X012

September 2012

Figure 4. Ball Attenuator Construction Details

E0816

HI-DENSITY
ATTENUATOR

CHARACTERIZED
ATTENUATOR

Figure 5. Exploded View of Dome, Ball, Tailpiece and Bearing Plates

E0817

13

Instruction Manual

V260 Valve
September 2012

D102178X012

Parts List

Key
23
24*

Note
Part numbers are shown for recommended spares only. For part
numbers not shown, contact your Emerson Process Management sales
office.

Key

Description

1

Valve Body
If you need a valve body as a replacement part, order the
valve size, pressure rating, serial number, and desired
material. Contact your Emerson Process Management
sales office.

2
3
4
5
6
7*

Inlet Tailpiece
Body Stud
Bearing Plate (2 req'd)
Dowel Pin (8 req'd)
Outlet Tailpiece
Seal Assembly O-Ring (1 req'd for single, 2 req'd for dual seal)
NPS 8
17B1353X012
NPS 10
17B1354X012
NPS 12
17B1355X012
NPS 16
17B4974X012
NPS 20
17B7414X012
NPS 24
GE00497X012
Wave Spring (1 req'd for single, 2 req'd for dual-seal)
Outlet Seal Assembly
See following table
Attenuator Dome for Dual Seal
See following table
Ball
Tailpiece O-Ring (2 req'd)
NPS 8
18B8211X012
NPS 10
18B8212X012
NPS 12
18B8213X012
NPS 16
18B8214X012
NPS 20
18B8215X012
NPS 24
GE00724X012
Dome Spacer
Packing Box O-Ring
NPS 8
17B1364X012
NPS 10
1D7104X0012
NPS 12
1D7104X0012
NPS 16
K18791X0012
NPS 20
17B7416X012
NPS 24
CL150 and CL300
17B7416X012
CL600
GE36050X012
Dome Spacer O-Ring
Packing Box Housing
Inlet Seal Assembly
See following table
Dowel Pin (4 req'd)
NPS 8
17B1374X012
NPS 10
1C7729X0012
NPS 12
1C7729X0012
NPS 16
1C7729X0012
NPS 20
17B7413X012
NPS 24
17B7413X012
Body Hex Nut
Drive Shaft
Actuator Mounting Cap Screw (4 req'd)
Packing Housing Stud, Steel

8
9*
10*
11
12*

13
14*

15
16
17*
18*

19
20
21
22

14

Description

Part Number

Part Number

Packing Housing Nut, Steel
Shaft Thrust Washer
NPS 8
17B1343X012
NPS 10 & 12
17B1345X012
NPS 16
17B4965X012
NPS 20
17B5026X012
NPS 24
CL150 and CL300
17B5026X012
CL600
GE36303X022
25
Pipe Plug (not shown)
26
Flow Arrow
27
Drive Screw, for nameplate
28*
Attenuator Dome for Single Seal
See following table
29*
Trunnion Bearing (2 req'd)
NPS 8
17B1359X012
NPS 10
17B1360X012
NPS 12
17B1361X012
NPS 16
17B4977X012
NPS 20
17B5027X012
NPS 24
CL150 and CL300
17B5027X012
CL600
GE36300X012
30*
Ball Thrust Washer (2 req'd)
NPS 8
17B1342X012
NPS 10
17B1344X012
NPS 12
17B1346X012
NPS 16
17B4966X012
NPS 20
17B5028X012
NPS 24
CL150 and CL300
17B5028X012
CL600
GE36360X012
32*
Shaft Bearing
NPS 8
17B1362X012
NPS 10 & 12
17B1363X012
NPS 16
17B4978X012
NPS 20
17B5029X012
NPS 24
CL150 and CL300
17B5029X012
CL600
GE36302X012
33
Pin, Attenuator Dome (not shown)
34
Nameplate (not shown)
36
Drive Screw (not shown)
37
Washer (not shown)
100
Packing Stud (2 req'd for NPS 8-12, 4 req'd for NPS 16-24)
101
Packing Nut (2 req'd for NPS 8-12, 4 req'd for NPS 16-24)
102
Packing Flange
105* Packing Set
ENVIRO-SEAL
PTFE/Carbon-Filled PTFE
NPS 8
14B3049X012
NPS 10 & 12
14B3060X012
NPS 16
14B5652X012
NPS 20
14B5730X012
Standard
PTFE/Carbon Filled PTFE
NPS 8
12A9057X022
NPS 10 & 12
1R6699X0012
NPS 16
14B5652X012
NPS 20
14B5730X012
NPS 24
17B5129X012
106
Anti-Extrusion Ring, PTFE
107
Packing Box Ring
116
Clamp (grounding strap assembly)
117
Grounding Strap Assembly

*Recommended spare parts

Instruction Manual

V260 Valve

D102178X012

September 2012

Figure 6. Fisher V260 Valve Assembly

STANDARD
FLOW
DIRECTION

NOTE: KEY NUMBERS 25, 33, AND 34 ARE NOT SHOWN.

54B9811-D

ATTENUATOR
DOME
WITH NO SEAL

15

Instruction Manual

V260 Valve
September 2012

D102178X012

Keys 9* & 17* Seal Assembly(1)
SEAL PART NUMBER
VALVE
SIZE, NPS

Key 9 (Outlet) - for dual seal constructions

Key 17 (Inlet) - for single and dual seal constructions

PTFE/PEEK

POM(2)

NACE
PTFE/PEEK

NACE POM

PTFE/PEEK

POM

NACE
PTFE/PEEK

NACE POM

8

28B1218X032

28B1218X012

28B1218X062

28B1218X052

27B1350X032

27B1350X012

27B1350X062

27B1350X052

10

28B1219X032

28B1219X012

28B1219X062

28B1219X052

27B1351X032

27B1351X012

27B1351X062

27B1351X052

12

28B1220X032

28B1220X012

28B1220X062

28B1220X052

27B1352X032

27B1352X012

27B1352X062

27B1352X052

16

37B4961X032

37B4961X012

37B4961X062

37B4961X052

37B4961X032

37B4961X012

37B4961X062

37B4961X052

20

37B5019X032

37B5019X012

37B5019X062

37B5019X052

37B5019X032

37B5019X012

37B5019X062

37B5019X052

24 CL150
& CL300

GE00488X032

GE00488X022

---

---

GE00488X032

GE00488X022

---

---

24 CL600

GE02813X022

GE02813X012

GE02813X032

GE02813X042

GE02813X022

GE02813X012

GE02813X032

GE02813X042

1. The V260C uses Key 17 in both the inlet and outlet.
2. POM (polyoxymethylene).

Keys 10* & 28* Attenuator Dome, S17400 SST
ATTENUATOR DOME PART NUMBER
VALVE

VALVE SIZE, NPS

Key 28 For single seal constructions

Key 10 For dual seal constructions

Characterized

High Density

Characterized

High Density

8

47B1312X012

47B1309X012

48B0916X012

48B0915X012

10

47B1313X012

47B1310X012

48B0918X012

48B0917X012

12

47B1314X012

47B1311X012

48B0920X012

48B0919X012

16

57B4946X012

57B4980X012

57B4982X012

57B4981X012

20

47B4990X012

47B4991X012

47B4992X012

47B4993X012

24 CL150 & CL300

GE39617X012

---

---

---

24 CL600

GG03694X012

GG03697X012

GG03695X012

GG03696X012

V260A

8

47B3510X012

47B3509X012

48B0922X012

48B0921X012

10

47B3514X012

47B3531X012

48B0924X012

48B0923X012

12

47B3518X012

47B3517X012

48B0988X012

48B0987X012

16

57B4984X012

57B4983X012

57B4986X012

57B4985X012

20

47B5033X012

47B5032X012

47B5031X012

47B5030X012

24 CL150 & CL300

GE00545X012

GE07146X012

GE00699X012

GE07157X012

24 CL600

GG02722X012

GG03691X012

GG02718X012

GG03688X012

V260B

*Recommended spare parts

Neither Emerson, Emerson Process Management, nor any of their affiliated entities assumes responsibility for the selection, use or maintenance
of any product. Responsibility for proper selection, use, and maintenance of any product remains solely with the purchaser and end user.
Fisher and ENVIRO-SEAL are marks owned by one of the companies in the Emerson Process Management business unit of Emerson Electric Co. Emerson
Process Management, Emerson, and the Emerson logo are trademarks and service marks of Emerson Electric Co. All other marks are the property of their
respective owners.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not
to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are
governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
Emerson Process Management
Marshalltown, Iowa 50158 USA
Sorocaba, 18087 Brazil
Chatham, Kent ME4 4QZ UK
Dubai, United Arab Emirates
Singapore 128461 Singapore

www.Fisher.com
16
E 1995, 2012 Fisher Controls International LLC. All rights reserved.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Producer                        : Acrobat Distiller 9.5.1 (Windows)
Modify Date                     : 2012:08:16 11:18:36-05:00
Create Date                     : 2012:08:16 11:18:07-05:00
Metadata Date                   : 2012:08:16 11:18:36-05:00
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:3f9ecf17-e0db-4a69-889f-98b69470ab07
Instance ID                     : uuid:2d462c39-e137-4607-bd8d-0a6b07761769
Page Count                      : 16
EXIF Metadata provided by EXIF.tools

Navigation menu