Emerson Type 627F Pressure Reducing Regulator Installation Guide 627F_IG_pr.p65
2015-03-30
: Emerson Emerson-Type-627F-Pressure-Reducing-Regulator-Installation-Guide-681394 emerson-type-627f-pressure-reducing-regulator-installation-guide-681394 emerson pdf
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
Installation Guide English – May 2002 Type 627F Introduction Installation This installation guide provides instructions for installation, startup, and adjustment. To receive a copy of the instruction manual, contact your local Fisher Sales Office or Sales Representative or view a copy at www.FISHERregulators.com. For further information refer to: Only qualified personnel should install or service a regulator. Regulators should be installed, operated, and maintained in accordance with international and applicable codes and regulations, and Fisher instructions. Type 627F Instruction Manual, form 5282, D101545X012. P.E.D. Categories If the regulator vents fluid or a leak develops in the system, it indicates that service is required. Failure to take the regulator out of service immediately may create a hazardous condition. This product may be used as a safety accessory with pressure equipment in the following Pressure Equipment Directive 97/23/EC categories. It may also be used outside of the Pressure Equipment Directive using sound engineering practice (SEP) per table below. PRODUCT SIZE CATEGORIES DN 20, 25, (3/4, 1-inch) SEP DN 50 (2-inch) II Personal injury, equipment damage, or leakage due to escaping fluid or bursting of pressure-containing parts may result if this regulator is overpressured or is installed where service conditions could exceed the limits given in the Specifications section, or where conditions exceed any ratings of the adjacent piping or piping connections. FLUID TYPE 1 Specifications To avoid such injury or damage, provide pressurerelieving or pressure-limiting devices (as required by the appropriate code, regulation, or standard) to prevent service conditions from exceeding limits. Body Sizes(1) DN 20, 25, or 50 (3/4, 1, or 2-inch) End Connection Styles(1) DN 20 (3/4-inch): NPT DN 25 or 50 (1 or 2-inch): NPT; ANSI Class 300RF or 600RF flanged Additionally, physical damage to the regulator could result in personal injury and property damage due to escaping fluid. To avoid such injury and damage, install the regulator in a safe location. Maximum Inlet and Differential Pressures(1) See table 1 Clean out all pipelines before installation of the regulator and check to be sure the regulator has not been damaged or has collected foreign material during shipping. For NPT bodies, apply pipe compound to the male pipe threads. For flanged bodies, use suitable line gaskets and approved piping and bolting practices. Install the regulator in any position desired, unless otherwise specified, but be sure flow through the body is in the direction indicated by the arrow on the body. Minimum Differential Pressures(1) Low Differential Actuator Spring 0,34 to 2,4 bar (5 to 35 psig): 0,69 bar (10 psi) 2,4 to 6,9 bar (35 to 100 psig): 1,4 bar (20 psi) High Differential Actuator Spring 0,34 to 2,4 bar (5 to 35 psig): 1,4 bar (20 psi) 2,4 to 6,9 bar (35 to 100 psig): 1,4 bar (20 psi) Maximum Emergency Outlet Pressure(1) 17,2 bar (250 psig) Outlet Pressure Ranges 0,34 to 2,4 bar (5 to 35 psig) 2,4 to 6,9 bar (35 to 100 psig) Note It is important that the regulator be installed so that the vent hole in the spring case is unobstructed at all times. For outdoor installations, the regulator should be located away from vehicular traffic and positioned so that water, ice, and other foreign materials cannot enter the spring case through the vent. Avoid placing the regulator beneath eaves or downspouts, and be sure it is above the probable snow level. Proof Test Pressure All Pressure Retaining Components have been proof tested per Directive 97/23/EC - Annex 1, Section 7.4 Temperature Capabilities -29 to 82°C (-20 to 180°F) 1. The pressure/temperature limits in this installation guide and any applicable standard or code limitation should not be exceeded. Table 1. Maximum Inlet and Differential Pressures 9,5 x 3,2 (3/8 x 1/8) 9,5 x 6,4 (3/8 x 1/4) 9,5 (3/8) 12,7 (1/2) LOW DIFFERENTIAL MAIN SPRING (SILVER), bar (PSIG) Maximum Inlet 6,9 6,9 6,9 4,1 (100) (100) (100) (60) HIGH DIFFERENTIAL MAIN SPRING (RED), bar (PSIG) Maximum Differential 6,9 6,9 6,9 4,1 (100) (100) (100) (60) www.FISHERregulators.com Maximum Inlet 17,2 17,2 17,2 8,6 (250) (250) (250) (125) Maximum Differential 17,2 17,2 17,2 8,6 (250) (250) (250) (125) D101545XENG ORIFICE SIZE, mm (INCHES) Type 627F Overpressure Protection The recommended pressure limitations are stamped on the regulator nameplate. Some type of overpressure protection is needed if the actual inlet pressure exceeds the maximum operating outlet pressure rating. Overpressure protection should also be provided if the regulator inlet pressure is greater than the safe working pressure of the downstream equipment. Regulator operation below the maximum pressure limitations does not preclude the possibility of damage from external sources or debris in the line. The regulator should be inspected for damage after any overpressure condition. properly adjusted, slowly open the upstream and downstream shutoff valves. Adjustment To change the outlet pressure, remove the closing cap or loosen the locknut and turn the adjusting screw clockwise to increase outlet pressure or counterclockwise to decrease pressure. Monitor the outlet pressure with a test gauge during the adjustment. Replace the closing cap or tighten the locknut to maintain the desired setting. Taking Out of Service (Shutdown) Startup The regulator is factory set at approximately the midpoint of the spring range or the pressure requested, so an initial adjustment may be required to give the desired results. With proper installation completed and relief valves To avoid personal injury resulting from sudden release of pressure, isolate the regulator from all pressure before attempting disassembly. Type 627F Parts List Key Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 23 24 29 31 32 34 36 37 39 53 54 55 56 58 59 60 61 62 63 Body Orifice Cap Screw Diaphragm Case O-Ring Diaphragm Case Boost Body O-Ring Stem Guide Disk Assembly Stem Stem O-Ring Stem Backup Ring Hair Pin Clip Drive Pin Lever Lever Retainer Lever Pin Lever Cap Screw Pusher Post Diaphragm Diaphragm Head Spring Case Lower Spring Seat Tension Spring Locknut Closing Cap Spring Case Cap Screw Nameplate Spring Retainer Diaphragm Connection Gasket Reducing Nipple Pipe Plug Elbow Pilot Supply Tubing Spring Seat Bolt Washer Closing Cap Gasket 32B3310-D Figure 1. Type 627F Assembly 2 Type 627F Type 6351F Parts List Key Description 1 2 3 4 6 7 8 9 10 11 22 23 24 28 35 44 Body Assembly Spring Case Body Plug Inner Valve Assembly Valve Spring Diaphragm Assembly Upper Spring Seat Control Spring Adjusting Screw Locknut Pipe Nipple Body Plug Gasket P590 Filter (Optional) Closing Cap Vent Assembly Restriction 32B3797-D Figure 2. Type 6351F Assembly P590 Series Parts List Key Description 1 2 3 4 5 6 7 Filter Body Filter Element Filter Head Machine Screw Washer Spring Washer Gasket A7008 Figure 3. Standard P590 Series Filter Assembly 3 Type 627F ©Fisher Controls International, Inc., 2002; All Rights Reserved Fisher and Fisher Regulators are marks owned by Fisher Controls International, Inc. The Emerson logo is a trade mark and service mark of Emerson Electric Co. All other marks are the property of their respective owners. The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such products at any time without notice. For information, contact Fisher Controls, International: Within USA (800) 588-5853 – Outside USA (972) 542-0132 Italy – (39) 051-4190-606 Singapore – (65) 770-8320 Mexico – (52) 57-28-0888 Printed in U.S.A. www.FISHERregulators.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 4 XMP Toolkit : XMP toolkit 3.0-28, framework 1.6 About : uuid:0a02189c-0c7f-4f32-b3af-296823e05203 Producer : Acrobat Distiller 5.0.5 (Windows) Create Date : 2002:06:18 15:07:56-05:00 Modify Date : 2010:05:07 14:32:52-05:00 Metadata Date : 2010:05:07 14:32:52-05:00 Creator Tool : PageMaker 6.5 Document ID : uuid:0a02189c-0c7f-4f32-b3af-296823e05203 Instance ID : uuid:0a02189c-0c7f-4f32-b3af-296823e05203 Creator : KDKOOZ Title : 627F_IG_pr.p65 Format : application/pdf Author : KDKOOZEXIF Metadata provided by EXIF.tools