Y600A Series

Instruction Manual
Form 5458
December 2008

Y600A Series Pressure Reducing Regulators
Introduction
Scope of Manual
This manual describes and provides instructions,
installation, maintenance, and parts lists for
	
Types Y600A, Y600AM, and Y600AR pressure
regulators. Instructions and parts lists for other
equipment used with these regulators are found in
separate manuals.

Product Description
The Y600A Series pressure reducing regulators may be
applied as switching valves, relay or pressure loading
regulators, or monitoring regulator pilots, and are
described as follows:
Type Y600A—Direct-operated regulator with internal
registration requiring no downstream control line.
Type Y600AM—Direct-operated regulator with blocked
throat, O-ring stem seal to prevent leakage around
the stem, and diaphragm casing tapped 1/2-inch NPT for
control line connection.
Type Y600AR—Type Y600A with internal relief valve.

Specifications
Ratings and specifications for the Y600A Series
regulators are given in the Specifications section on
page 2. Individual regulator data is stamped on the
closing cap as it comes from the factory.

Installation
!

Warning

Figure 1. Type Y600A Pressure Regulator

regulator is over pressured or is installed
where service conditions could exceed
the limits given in the Specifications
section, or where conditions exceed
any ratings of the adjacent piping or
piping connections.
To avoid such injury or damage, provide
pressure-relieving or pressure-limiting
devices (as required by the appropriate
code, regulation, or standard) to prevent
service conditions from exceeding
those limits.
Additionally, physical damage to the
regulator could cause personal injury
or property damage due to escaping
gas. To avoid such injury or damage,
install the regulator in a safe and well
ventilated location.
Regulator operation within ratings does not preclude
the possibility of damage from debris in the lines or
from external sources. A regulator should be inspected
for damage periodically and after any overpressure
condition. Key numbers referenced in this section are
shown in Figures 3 through 6.
D102511X012

Personal injury, property damage,
equipment damage, or leakage due to
escaping gas or bursting of pressurecontaining parts may result if this

W7095

www.emersonprocess.com/regulators

Y600A Series
Specifications
Body Sizes (Inlet x Outlet) and End
Connection Style(1)
3/4 x 3/4 or 1 x 1-inch NPT

Outlet Pressure Ranges(2)
See Table 1
Flow Coefficients
See Table 2

Maximum Inlet Pressure (Body Rating)(2)
150 psig (10,3 bar)

Temperature Capabilities(2)
–20° to 180°F (–29° to 82°C)

Maximum Outlet Pressure (Casing)(2)
20 psig (1,38 bar)

Spring Case Vent Connection
1/4-inch NPT

Maximum Operating Inlet Pressure
See Table 2

Diaphragm Case Connection
1/2-inch NPT

Maximum Operating Outlet Pressure to Avoid Internal
Parts Damage(2)
2 psig (0,14 bar) above outlet pressure setting

Approximate Weight
13 pounds (5,9 kg)

  1.  End connections for other than U.S. standards can usually be provided; consult your local Sales Office.
  2.  The pressure/temperature limits in this instruction manual and any applicable standard or code limitation should not be exceeded.

Table 1. Outlet (Control) Pressure Ranges
Type
number

Y600A,
Y600AM,
Y600AR

approximate point above pressure
setting at which THE type y600ar
internal relief starts to discharge

spring
color

spring part
number

outlet pressure range with
spring case above diaphragm(1)

Red

1B653827052

Olive drab

1B653927022

Yellow

1B537027052

Light green

1B537127022

1.2 to 2.5 psig

(0,08 to 0,17 bar)

0.5 to 2 psig

(0,03 to 0,14 bar)

Light blue

1B537227022

2.5 to 4.5 psig

(0,17 to 0,31 bar)

0.5 to 3 psig

(0,03 to 0,21 bar)

Black

1B537327052

4.5 to 7 psig

(0,31 to 0,48 bar)

1 to 4 psig

(0,07 to 0,28 bar)

4 to 8-inches w.c.

(10 to 20 mbar)

7 to 16-inches w.c.

(17 to 40 mbar)

15-inches w.c. to 1.2 psig (37 to 83 mbar)

10 to 24-inches w.c.

(25 to 60 mbar)

10 to 26-inches w.c.

(25 to 65 mbar)

1.  Minimum outlet pressure setting may be approximately 1-inch w.c. (2 mbar) lower if spring case is below diaphragm.

Table 2. Maximum Operating Inlet Pressures
wide-open FLOW COEFFICIENTS
for external relief sizing

Maximum operating inlet pressure, psig (bar)
Orifice size,
inches (mm)

With 1.2 Psig
(0,08 bar) or Less
Outlet Pressure
Setting

With 1.2 to 2.5 Psig
(0,08 to 0,17 bar)
Outlet Pressure
Setting

With 4.5 to 7 Psig
(0,31 to 0,48 bar)
Outlet Pressure
Setting

cg

Cv

C1

1/8 (3,17)

150 (10,3)

150 (10,3)

150 (10,3)

150 (10,3)

12.3

0.35

35

3/16 (4,76)

150 (10,3)

150 (10,3)

150 (10,3)

150 (10,3)

27.6

0.79

35

1/4 (6,35)

75 (5,17)

150 (10,3)

150 (10,3)

150 (10,3)

50

1.43

35

3/8 (9,53)

35 (2,41)

60 (4,14)

60 (4,14)

60 (4,14)

110

3.14

35

1/2 (12,7)

8 (0,55)

10 (0,69)

12 (0,83)

12 (0,83)

200

5.71

35

9/16 (14,3)

5 (0,34)

6 (0,41)

8 (0,55)

8 (0,55)

250

7.14

35

Note
If the regulator is shipped mounted on
another unit, install that unit according to
the appropriate instruction manual.

2

With 2.5 to 4.5 Psig
(0,17 to 0,31 bar)
Outlet Pressure
Setting

  1.  Only personnel qualified through training and 	 	
experience should install, operate, and maintain a 	
regulator. For a regulator that is shipped separately, 	
make sure that there is no damage to, or foreign 	
material in the regulator. Also ensure that all tubing 	
and piping are free of debris.

Y600A Series
  2.  The regulator may be installed in any position as 	

long as the flow through the body is in the direction 	
indicated by the arrow cast on the body. If 	
continous operation is required during inspection or 	
maintenance, install a three-valve bypass around
	
the regulator.

!

Warning

A regulator may vent some gas to the
atmosphere. In hazardous or flammable
gas service, vented gas may accumulate
and cause personal injury, death, or
property damage due to fire or explosion.
Vent a regulator in hazardous gas service
to a remote, safe location away from air
intakes or any hazardous area. The vent
line or stack opening must be protected
against condensation or clogging.
  3.  Be certain that the vent (key 26) is not positioned 	
so that it can collect moisture which may drain into 	
the spring case. The diaphragm casing (key 4) may 	
be rotated to any of four positions with respect to the 	
body in order to obtain desired positioning. Perform 	
Body Area Maintenance procedure steps 1 and 4 	
through 8 to rotate the diaphragm casing.
  4.  The Type Y600AM regulator requires a downstream 	

control line. Be sure to install this control line before 	
putting the regulator into operation. The downstream 	
control line pipe should be at least 1/2-inch (12,7mm) 	
in diameter and connected to a straight section of 	
outlet piping at least 5 to 10 pipe diameters downstream	
of the regulator. If instability due to turbulence exists, 	
a hand valve can be installed in a straight section of 	
the control line. This hand valve can be throttled down 	
to dampen out pulsations.

Startup and Adjustment
A Y600A Series regulator can be placed in operation by
slowly introducing inlet pressure. The regulator takes
control when downstream pressure is established.
The regulator has been adjusted at the factory to provide
approximately the reduced pressure requested on the
order. With a spring-loaded regulator, the pressure
setting may be adjusted within the spring range shown
in Table 1. To adjust the pressure setting, perform the
following steps (key numbers are referenced in Figures 3
through 6):
  1.  Remove the closing cap (key 22).

  2.  Use a 1-inch (25,4 mm) hex rod or screwdriver to 	
turn the adjusting screw (key 35) either clockwise to 	
increase outlet pressure or counterclockwise to 	
decrease outlet pressure.

!

Warning

To avoid personal injury, property
damage, or equipment damage caused
by bursting of pressure containing parts
or explosion of accumulated gas, never
adjust the control spring to produce an
outlet pressure higher than the upper
limit of the outlet pressure range for
that particular spring. If the desired
outlet pressure is not within the range
of the control spring, install a spring
of the proper range according to the
Diaphragm and Spring Case Area section
of the Maintenance procedure.

  3.  After making the adjustment and replacing the 	 	

closing cap (key 22), the closing cap can be wired to 	
the spring case (key 3) to discourage tampering.

Shutdown
First close the nearest upstream shutoff valve and then
close the nearest downstream shutoff valve to vent the
regulator properly. Next, open the vent valve between
the regulator and the downstream shutoff valve closest to
it. All pressure between these shutoff valves is released
through the open vent valve, since a Y600A Series
regulator remains open in response to the decreasing
downstream pressure.

Maintenance
Regulator parts are subject to normal wear and must be
inspected and replaced as necessary. The frequency
of inspection and replacement of parts depends on
the severity of service conditions and upon applicable
codes and government regulations. Key numbers are
referenced in Figures 3 through 5 unless otherwise noted.

!

Warning

To avoid personal injury, property damage,
or equipment damage caused by sudden
release of pressure or explosion of
accumulated gas, do not attempt any
maintenance or disassembly without
first isolating the regulator from system
pressure and relieving all internal pressure
from the regulator.

3

Y600A Series
Body Area
This procedure is for gaining access to the disk assembly,
orifice, body O-ring, and pitot tube if used. All pressure
must be released from the diaphragm casing, and the
disk assembly must be open, before these steps can
be performed.

BODY SEAL
o-ring (Key 11)
Backup ring
(Key 48)
Body (Key 1)

  1.  Remove the cap screws (key 2) and separate the 	

diaphragm casing (key 4) from the body (key 1).

  2.  Remove and inspect the body seal O-ring (key 11) and 	
the backup ring (key 48). See Figure 2.
  3.  Inspect and replace the orifice (key 5) if necessary. 	
Protect the orifice seating surface during disassembly 	
and assembly. Lubricate the threads of the 	
	
replacement 	orifice with a good grade of light grease 	
and install with 29 to 37 foot-pounds (39 to 50 N•m) 	
of torque.
  4.  To replace the disk assembly (key 13), remove the 	
cotter pin (key 15). If not necessary, skip to step 7.
  5.  To replace the pitot tube (key 32, Figures 3 and 6) on 	
the Types Y600A and Y600AR, remove the machine 	
screws (key 33), install the new pitot tube, and secure 	
with the machine screws. Position the pitot tube so 	
that it points into the outlet of the body (key 1) by 	
rotating the guide insert (key 18).
  6.  Install the disk assembly (key 13) and secure it with 	
the cotter pin (key 15).
  7.  Place backup ring (key 48) into the body (key 1). 	
Then place the body seal O-ring (key 11) into the 	
body. See Figure 2.
  8.  Place the diaphragm casing (key 4) on the body
	
(key 1). Secure the the diaphragm casing to the body 	
with the cap screws (key 2) using 7 to 9 foot-pounds 	
(9 to 12 N•m).

Diaphragm and Spring Case Area
This procedure is for gaining access to the spring,
diaphragm, lever assembly stem, and Type Y600AM
stem O-ring. All pressure must be released from the
diaphragm casing before performing these steps.
Note
Any Type 662 remote control drive unit
used with a Y600A Series regulator must
be removed from the spring case (key 3)
before these steps can be performed.

4

Figure 2. Expanded View of the Body Area Showing
the Body Seal O-ring and Backup Ring Placement

1.  Remove the closing cap (key 22), and turn the 	 	
adjusting screw (key 35) counterclockwise to remove 	
the compression from the spring (key 6).
2.  If the only maintenance is to change the control 	
spring, take out the control spring and replace with 	
the desired spring. Turn the adjusting screw (key 35) 	
clockwise to compress the spring to the desired outlet 	
pressure setting. Skip to step 11.
  3.  If further maintenance to the internal diaphragm 	
casing parts is required, remove the hex nuts (key 23, 	
not shown) and cap screws (key 24). Remove the 	
diaphragm (key 10) plus attached parts by tilting 	
them so that the pusher post (key 8) slips off the lever 	
assembly (key 16). To separate the diaphragm from 	
the attached parts, unscrew the cap screw (key 38, 	
Figures 3 and 4) from the pusher post (key 8) 	
	
for a Type Y600A or Y600AM, or unscrew the relief 	
valve spring holder (key 37, Figure 6) from the pusher 	
post (key 8) for a Type Y600AR. If the only further 	
maintenance is to replace the diaphragm parts, skip 	
to step 7.
  4.  To replace the lever assembly (key 16), remove the 	
machine screws (key 17). To replace the stem
(key 14) or the Type Y600AM stem O-ring (key 30, 	
Figure 4), also perform Body Area Maintenance 	
procedure steps 1 and 4, and pull the stem (key 14) 	
out of the diaphragm casing (key 4). With a Type 	
Y600AM, grease the replacement stem O-ring
	
(key 30, Figure 4) with a good grade of lubricant and 	
install it on the tem (key 14).
  5.  Install the stem (key 14) into the diaphragm casing 	
(key 4) and perform Body Area Maintenance 	
	
procedure steps 6 through 8 as necessary.

Y600A Series
  6.  Install the lever assembly (key 16) into the stem 	
(key 14) and secure the lever assembly with the 	
machine screws (key 17).
  7.  For a Type Y600A or Y600AM (Figures 3 and 4), 	
hold the pusher post (key 8) and place diaphragm 	
assembly parts on the pusher post in the following 	
order: diaphragm (key 10), diaphragm head (key 7), 	
lower spring seat (key 50), and washer (key 36),
and secure with diaphragm cap screw (key 38)
using 7 to 9 foot-pounds (9 to 12 N•m) of torque or
for a Type Y600AR (Figure 6), secure the pusher
post (key 8) to the relief valve spring holder with
1 to 3 foot-pounds (1,4 to 4,1 N•m) of torque.
  8.  Install the pusher post (key 8) and attached parts 	
onto the lever (key 16).
  9.  Install the control spring (key 6) and spring case 	
(key 3) on the diaphragm casing (key 4) so that the 	
vent assembly (key 26) is correctly oriented, and 	
secure them with the cap screws (key 24) and hex 	
nuts (key 23) to finger tightness only.
  10.  Turn the adjusting screw (key 35) clockwise until 	
there is enough control spring (key 6) force to 	
provide proper slack to the diaphragm (key 10). 	
Using a crisscross pattern, finish tightening the cap 	
screws (key 24) and hex nuts to 5 to 6 foot-pounds 	
(6,8 to 8,1 N•m) of torque. Finish turning the 	
	
adjusting screw to the desired outlet pressure setting.
  11.  Install the closing cap (key 22) or the Type 662 	
remote control drive unit, if used.

To Convert Constructions
The Type Y600A to the Type Y600AM:
New parts required: keys 30, 31, and 33
  1.  Remove pipe plug (key 27) from the diaphragm 	
casing (key 4).
  2.  Refer to steps 1 and 5 in the Body Area Maintenance 	
section to remove the four machine screws (key 33) 	
and pitot tube (key 32, Figure 3).
  3.  Insert the throat O-ring (key 31, Figure 4) and one 	
machine screw (key 33, Figure 4).
  4.  Insert the stem O-ring (key 30, Figure 4) by following 	
steps 1 through 6 in the Diaphragm and Spring Case 	
Area Maintenance section.

The Type Y600AM to the Type Y600A:
New parts required: keys 27, 32, and 33

  1.  Insert pipe plug (key 27, Figure 4) in the diaphragm 	
casing (key 4).
  2.  Follow steps 1 through 4 in the Diaphragm and 	
Spring Case Area Maintenance section to remove 	
one machine screw (key 33, Figure 3), the stem
	
seal O-ring (key 30, Figure 4), and the throat seal 	
(key 31, Figure 4) blocking the registration port.
  3.  Insert pitot tube (key 32) and four machine screws
(key 33) as outlined in step 5 of the Body Area 	
Maintenance section.

Parts Ordering
When corresponding with your local Sales Office about
this regulator, include the type number and all other
pertinent information stamped on the closing cap.
Specify the eleven-character part number when ordering
new parts from the following parts list.

Parts List (Figures 3 through 6)
Key	 Description	
	
Parts Kit (keys 10, 11, 12, 13, 15, 30, and 31)
	  Types Y600A and Y600AM	
	  Type Y600AR	
  1	
Body, Cast iron	
	  3/4 x 3/4-inch	
	  1 x 1-inch	
  2	
Cap Screw (2 required), Plated steel 	
  3	
Spring Case Assembly, Cast iron	
  4	
Diaphragm Casing, Cast iron	
  5	
Orifice, Aluminum
	  1/8-inch (3,18 mm)	
	  3/16-inch (4,76 mm)	
	  1/4-inch (6,35 mm)	
	  3/8-inch (9,53 mm)	
	  1/2-inch (12,7 mm)	
	  9/16-inch (14,3 mm)	
  6	
Spring, Plated steel
	  4 to 8-inches w.c. (10 to 20 mbar)	
	  7 to 16-inches w.c. (17 to 40 mbar)	
	  15-inches w.c. to 1.2 psig (37 to 83 mbar)	
 	  1.2 to 2.5 psig (0,08 to 0,17 bar)	
	  2.5 to 4.5 psig (0,17 to 0,31 bar)	
	  4.5 to 7 psig (0,31 to 0,48 bar)	
  7	
Diaphragm Head
	  Types Y600A and Y600AM, 304 Stainless steel	
	  Type Y600AR, Plated steel	
  8	
Pusher Post
	  Types Y600A and Y600AM, Aluminum	
	  Type Y600AR, Zinc	
  10*	 Diaphragm, Nitrile (NBR)
	  Types Y600A and Y600AM	
	  Type Y600AR	
  11*	 Body Seal O-ring, Nitrile (NBR)	
  12*	 Insert Seal O-ring, Nitrile (NBR)	
  13*	 Disk Assembly, Aluminum Disk Holder
	  with Nitrile (NBR) disk	
  14	 Stem, Stainless Steel	
  15*	 Cotter Pin, Stainless steel	

Part Number
RY600AX0012
RY600ARX012
1E987119012
1E987319012
1C856228992
1B6365X0342
47B2271X012
1A936709012
00991209012
0B042009012
0B042209012
1A928809012
1C4252X0012
1B653827052
1B653927022
1B537027052
1B537127022
1B537227022
1B537327052
17B9723X032
1B541425072
17B9734X032
2B541944012
17B9726X012
1C942902072
1H993806992
1B885506992
1C4248X0212
17B3423X012
1A866537022

* Recommended spare part.

5

Y600A Series

A7141_1

Figure 3. Type Y600A Regulator Assembly

Key	 Description	
16	 Lever Assembly, Plated steel	
  17	 Machine Screw (2 required), Stainless steel	
  18	 Guide Insert, Delrin	
  22	 Closing Cap, Thermoplastic	
  23	 Hex Nut, not shown (8 required), Plated steel	
  24	 Cap Screw (8 required), Plated steel	
  26	 Type Y602 Vent Assembly
	  Spring case up (standard)	
	  Spring case down	
  27	 Pipe Plug, Plated steel
	  (Types Y600A and Y600AR only)	
  30*	 Stem O-Ring (Type Y600AM only),
	  Nitrile (NBR) 	
  31*	 Throat Seal O-Ring (Type Y600AM only),
	  Nitrile (NBR) 	
* Recommended spare part.

6

Part Number
1B5375X0082
19A7151X022
27B4028X012
T13524T0062
1E985324142
T1070824912
17A5515X012
17A6570X012
1A369224492
1H292606992
1D682506992

Key	 Description	
32	 Pitot Tube (Types Y600A and Y600AR only),
	  304 Stainless steel	
  33	 Machine Screw, Stainless steel
	  Type Y600AM (1 required)	
	  Types Y600A and Y600AR (4 required)	
  35	 Adjusting Screw, Zinc	
  36	 Washer	
  37	 Spring Holder (Type Y600AR only),
	  Plated steel 	
  38	 Diaphragm Cap Screw (Types Y600A and
	  Y600AM only), Plated steel 	
  39	 Relief Valve Spring (Type Y600AR only),
	  Plated steel	
  48	 Back Up Ring, Stainless Steel	
  50	 Lower Spring Seat (Types Y600A and
	  Y600AM only), Plated steel	

Part Number
17B4479X012
18A0703X022
19A7151X022
1B537944012
18B3440X012
1C323114012
1B290524052
1B541327022
18B3446X012
1B636325062

Y600A Series

A7142_1

Figure 4. Type Y600AM Regulator Assembly

2
A7144

Figure 5. Diaphragm Casing Cap Screw Location

7

Y600A Series

48
A7143

Figure 6. Type Y600AR Regulator Assembly

Industrial Regulators

Natural Gas Technologies

TESCOM

Emerson Process Management
Regulator Technologies, Inc.

Emerson Process Management
Regulator Technologies, Inc.

Emerson Process Management
Tescom Corporation

USA - Headquarters
McKinney, Texas 75069-1872 USA
Tel: 1-800-558-5853
Outside U.S. 1-972-548-3574

USA - Headquarters
McKinney, Texas 75069-1872 USA
Tel: 1-800-558-5853
Outside U.S. 1-972-548-3574

USA - Headquarters
Elk River, Minnesota 55330-2445 USA
Tel: 1-763-241-3238

Asia-Pacific
Shanghai, China 201206
Tel: +86 21 2892 9000

Asia-Pacific
Singapore, Singapore 128461
Tel: +65 6777 8211

Europe
Bologna, Italy 40013
Tel: +39 051 4190611

Europe
Bologna, Italy 40013
Tel: +39 051 4190611
Gallardon, France 28320
Tel: +33 (0)2 37 33 47 00

Middle East and Africa
Dubai, United Arab Emirates
Tel: +971 4811 8100

Europe
Selmsdorf, Germany 23923
Tel: +49 (0) 38823 31 0

For further information visit www.emersonprocess.com/regulators
The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls, Inc., a
business of Emerson Process Management.
The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or
guarantees, express or implied, regarding the products or services described herein or their use or applicability. We reserve the right to modify or improve the designs or specifications of such
products at any time without notice.
Emerson Process Management does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson
Process Management product remains solely with the purchaser.

©Emerson Process Management Regulator Technologies, Inc., 1999, 2008; All Rights Reserved



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c006 1.236519, Wed Jun 14 2006 08:31:24
Create Date                     : 2008:12:04 18:00:39+08:00
Metadata Date                   : 2008:12:04 18:00:44+08:00
Modify Date                     : 2008:12:04 18:00:44+08:00
Creator Tool                    : Adobe InDesign CS3 (5.0)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 10502 bytes, use -b option to extract)
Instance ID                     : uuid:ec422f8f-0c9d-4d04-aaea-aca903599d26
Document ID                     : adobe:docid:indd:95cfff38-36f5-11dd-90dd-8662aff47c7e
Rendition Class                 : proof:pdf
Derived From Instance ID        : 95cfff37-36f5-11dd-90dd-8662aff47c7e
Derived From Document ID        : adobe:docid:indd:6672e2a1-30e1-11db-bade-f0c5ff0eb00e
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 300.00, 762.00, 762.00, 300.00, 72.00, 72.00, 762.00
Manifest Placed Y Resolution    : 72.00, 300.00, 762.00, 762.00, 300.00, 72.00, 72.00, 762.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:f8cb9cde-23c5-11da-bf8f-000a95badf96, uuid:97D7799DE332DD119926FF92D50A23B1, uuid:453ACEB4E332DD119926FF92D50A23B1, uuid:423ACEB4E332DD119926FF92D50A23B1, uuid:3F3ACEB4E332DD119926FF92D50A23B1, uuid:811825a1-1262-4d50-9cec-47d2cdd9cb38, uuid:f8cb9cde-23c5-11da-bf8f-000a95badf96, uuid:9DD7799DE332DD119926FF92D50A23B1
Manifest Reference Document ID  : adobe:docid:photoshop:7bb7ea4a-04c3-11da-8ed8-be64f00ad377, adobe:docid:photoshop:7bb7ea4e-04c3-11da-8ed8-be64f00ad377, adobe:docid:photoshop:10593b03-0563-11da-821d-e87be5b5d786, adobe:docid:photoshop:10593b07-0563-11da-821d-e87be5b5d786, uuid:86790746863BDD11BBC98F27EBA60EE5, adobe:docid:photoshop:070979c0-0568-11da-821d-e87be5b5d786
Format                          : application/pdf
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
Page Count                      : 8
Creator                         : Adobe InDesign CS3 (5.0)
EXIF Metadata provided by EXIF.tools

Navigation menu