EnGenius Technologies ENH710EXT N600 2T2R Base Station User Manual
EnGenius Technologies N600 2T2R Base Station
User manual
Business Solutions User Manual ENH710EXT version 1.0 Dual Band Long Range Wireless N600 Outdoor Access Point IMPORTANT To install this Access Point please refer to the Quick Installation Guide included in the product packaging. Table of Contents Chapter 1 Product Overview............................................... 4 Key Features/Introduction........................................................ 5 System Requirements............................................................... 6 Package Contents......................................................................... 7 Technical Specifications.............................................................. 8 Physical Interface.......................................................................... 10 Wireless Security.......................................................................... 41 Wireless MAC Filtering............................................................... 42 Wireless Advanced..................................................................... 43 WPS Mixed-Enterprise: AP/WDS AP Mode........................... 44 WDS Link Settings....................................................................... 45 Client Bridge Settings.............................................................. 46 Guest Network Settings............................................................ 47 Chapter 2 Before You Begin................................................. 11 Computer Settings....................................................................... 12 Hardware Installation................................................................. 15 Mounting the ENH710EXT...................................................... 16 Chapter 8 Management ........................................................ 48 Management VLAN Settings.................................................. 49 Advanced Settings....................................................................... 50 CLI Settings/Email Alert............................................................. 51 Time Zone........................................................................................ 53 Auto Reboot Settings................................................................ 54 Wi-Fi Scheduler............................................................................... 55 Tools.................................................................................................. 56 Account/Firmware........................................................................ 58 Backup/Restore ............................................................................. 59 Log...................................................................................................... 61 Logout/Reset................................................................................. 62 Appendix................................................................................. 63 FCC Interference Statement................................................... 64 CE Interference Statement...................................................... 65 IC Interference Statement....................................................... 68 Professional Installation Instruction.................................... 69 Instructions d’installation professionnelle...................... 70 Detachable Antenna Usage.................................................... 71 Chapter 3 Configuring Your Access Point......................... 20 Default Settings./Web Configuration................................ 21 Chapter 4 Building a Wireless Network........................... 22 Access Point Mode...................................................................... 23 Client Bridge Mode...................................................................... 24 WDS AP Mode.............................................................................. 25 WDS Bridge Mode........................................................................ 26 WDS Station Mode....................................................................... 27 Chapter 5 Status.................................................................... 28 Main Status..................................................................................... 29 Connection...................................................................................... 31 Chapter 6 Network .............................................................. 33 Basic IP Settings............................................................................ 34 Spanning Tree Protocol Setting............................................. 35 Chapter 7 2.4 GHz/5 GHz Wireless....................................... 36 Wireless Settings............................................................................ 37 2.4 GHz/5 GHz Wireless Network........................................... 38 2.4GHz/5 GHz SSID Profile...................................................... 40 Chapter 1 Product Overview Introduction Key Features • Up to 27 dBm transmit power enabling long range connectivity • Supports IEEE802.11a/b/g/n wireless standards with up to 300 Mbps data rate on each band. • Two detachable 5 dBi 2.4 GHz Omni-directional antennas • Two detachable 7 dBi 5 GHz Omni-directional antennas • Can be used with included power adapter or via PoE with PoE 802.3at - capable switches or injectors • Band Steering shifts dual band clients to 5 GHz for better throughput performance • Secured Guest Network option available Introduction The ENH710EXT is a high-powered, long-range 2x2 DualBand Wireless 802.11a/b/g/n Outdoor Access Point with speeds up to 450 Mbps on both its high-powered 2.4 GHz and 5 GHz radios. It can be configured as an: Access Point, Client Bridge or WDS (AP, Station & Bridge). The ENH710EXT is designed to operate in a variety of outdoor environments. Its high-powered, long-range characteristics make it a cost effective alternative to ordinary Access Points that don’t have the range and reach to connect to a growing number of wireless users who wish to connect to a business network. The ENH710EXT supports the 2.4 GHz frequency band under 802.11 b/g/n mode while at the same time providing the 5 GHz band for communicating to and from other 5 GHz capable computers, tablets or smart phones or transferring files. Several ENH710EXTs can be deployed in a campus setting using the 5 GHz band as Maximum data rates are based on IEEE 802.11 standards. Actual throughput and range may vary depending on many factors including environmental conditions, distance between devices, radio interference in the operating environment, and mix of devices in the network. Features and specifications subject to change without notice. Trademarks and registered trademarks are the property of their respective owners. For United States of America: Copyright © 2014 EnGenius Technologies, Inc. All rights reserved. System Requirements a backhaul to provide multiple 2.4 GHz wireless cells for computers or mobile devices in common outdoor areas. The ENH710EXT is easy to install in virtually any location with its included PoE (Power over Ethernet) injector for quick outdoor installation. The ENH710EXT enables network administrators to control its transmit power and features settings for selecting narrow bandwidth and traffic shaping. The ENH710EXT also supports wireless encryption including Wi-Fi Protected Access (WPA-PSK/ WPA2-PSK) Encryption and IEEE 802.1X with RADIUS.) The following are the Minimum System Requirements in order to configure the device. • Computer with an Ethernet interface or wireless network capability • Windows OS (XP, Vista, 7, 8), Mac OS, or Linux-based operating systems • Web-Browsing Application (i.e.: Internet Explorer, Firefox, Safari, or another similar browser application) Package Contents The ENH710EXT package contains the following items:* • ENH710EXT Access Point • 2 detachable 5 dBi 2.4 GHz Omni-directional Antenna • 2 detachable 7 dBi 5 GHz Omni-directional Antenna • Power Adapter • PoE Injector (EPE-48GR) • Grounding Cable • Pole Mount Bracket • Wall Mount Base • Mounting Screw Set • Quick Installation Guide *(all items must be in package to issue a refund): Technical Specifications WDS Detail WDS AP WDS Bridge WDS Station Standard: IEEE802.11a/n on 5 GHz IEEE802.11b/g/n on 2.4 GHz IEEE802.3at Antenna 4 External N-type Antennas 2 x detachable 5dBi 2.4GHz Omni-directional Antennas 2 x detachable 7dBi 5GHz Omni-directional Antennas Optimal Performance Distance Control (Ack Timeout) Multicast Supported Band Steering Fast Roaming Auto Channel Selection BSSID Support Physical Interface 2 x 10/100/1000 Gigabit Ethernet Port with PoE support LAN1 Port supports IEEE802.3at PoE Input LED Indicator Power LAN 1 LAN 2 2.4 GHz 5 GHz Easily Management VLAN Tag / VLAN Pass-through Guest Network QoS: Complaint with IEEE 802.11e /WMM RADIUS Accounting Wireless STA (Client) connection list Traffic Shaping (Per SSID, Per user) Power Requirements External Power Adapter, DC IN, 48V/0.8A IEEE802.3at support Intuitive Tools SNMP v1/v2c/v3 support MIB I/II, Private MIB Save Configuration as Default CLI Support WiFi-Scheduler/Auto Reboot E-mail Alert Operation Modes Access Point Client Bridge WDS Reinforcement Security WEP Encryption-64/128/152 bit WPA/WPA2 Enterprise (WPA-EAP using TKIP or AES) Hide SSID in beacons MAC address filtering up to 32 MACs per SSID Https Support SSH QoS (Quality of Service) Complaint with IEEE 802.11e standard Physical/Environment Conditions Operating: Temperature: -4 °F to 158 °F (-20 °C to 70 °C) Humidity (non-condensing): 90% or less Storage: Temperature: -22 °F to 176 °F (-30 °C to 80 °C) Humidity (non-condensing): 90% or less Physical Interface Dimensions and Weights Length: 280.48mm (11.22”) Width: 217.65mm (8.58”) Depth: 55.50mm (2.1”) Weight: 1.88Kg (4.17 lbs) 1 2.4 GHz Antennas: Detachable 5 dBi 2.4 GHz Omni-directional 2 5 GHz Antennas: Detachable 7 dBi 5 GHz Omni-directional 3 LAN Port 1 (802.3at PoE Input): Ethernet port for RJ-45 cable. 4 LAN Port 2: Ethernet port for RJ-45 cable. 5 LED Indicators: LED lights for Power, LAN Port 1, LAN Port 2, 2.4 GHz Connection and 5 GHz Connection. 6 Ground 7 Mounting Holes: Using the provided hardware, the ENH710EXT can be attached to a wall or pole. 10 Chapter 2 Before You Begin 11 Computer Settings Windows XP/Windows 7/Windows 8 1b. Move your mouse to the lower right hot corner to display the Charms Bar and select the Control Panel in Windows 8 OS. In order to use the ENH710EXT, you must first configure the TCP/IPv4 connection of your Windows OS computer system. 1a. Click the Start button and open the Control Panel 2a. In Windows XP, click Network Connections. Windows XP Windows 7 2b. In Windows 7/Windows 8, click View Network Status and Tasks in the Network and Internet section, then select Change adapter settings. 12 3. Right click on Local Area Connection and select Properties. 5. Select Use the following IP address and enter an IP address that is different from the ENH710EXTand Subnet mask, then click OK. Note: Ensure that the IP address and Subnet mask are on the same subnet as the device. For example: ENH710EXT IP address: 192.168.1.1 PC IP address: 192.168.1.2 – 192.168.1.255 PC Subnet mask: 255.255.255.0 4. Select Internet Protocol Version 4 (TCP/IPv4) and then select Properties. 13 Apple Mac OS X 1. Go to System Preferences (Which can be opened in the Applications folder or selecting it in the Apple Menu). 4. In Configure IPv4, select Manually. 5. Enter an IP address that is different from the ENH710EXT and Subnet mask then press OK. 2. Select Network in the Internet & Network section. Note: Ensure that the IP address and Subnet mask are on the same subnet as the device. For example: ENH710EXT IP address: 192.168.1.1 PC IP address: 192.168.1.2 – 192.168.1.255 PC Subnet mask: 255.255.255.0 6. Click Apply when done. 3. Highlight Ethernet. 14 Hardware Installation 1. Connect one end of the Ethernet cable into the main LAN port (PoE) of the Access Point and the other end to the AP Ethernet port on the PoE injector. This diagram depicts the hardware configuration. 2. Connect the Power Adapter to the DC-IN port of the PoE injector and plug the other end in to an electrical outlet. 3. Connect the second Ethernet cable into the LAN port of the PoE injector and the other end to the Ethernet port on the computer. 4. Screw on the provided antennas to the device. Once both connections are secure, verify the following: PoE Injector/ PoE Swtich a) Ensure that the POWER light is on (it will be green). Ethernet b) Ensure that the 2.4 GHz/5 GHz WLAN light is on (it will be green for both 5 GHz and 2.4 GHz). PC Power Outlet c) Ensure that the LAN (Computer/ENH710EXT Connection) light is on (it will be green). Note: The Access Point supports both IEEE 802.3at PoE (Power over Ethernet) or the included power injector. You may use either one as the power source. Do NOT use both at the same time. d) Once all three lights are on, proceed to set up the Access Point using the computer. 15 Mounting the ENH710EXT Using the provided hardware, the ENH710EXT can be attached to a wall or a pole. 1. Wall Mount Kit: 260x180x7 (mm) (10.2" x 7.09" x 0.28") 3. Pipe 63.5 (D) x 12.7 (mm) (2.5"(D) x 0.5") 2. Pole Mount Kit 140x112x33 (mm) (5.51" x 4.41" x 1.30") 4. Tool 20(D) x 6 (mm) (0.79"(D) x 0.24") 16 5. Screws: 6.5(D) x 9.95 (mm) (0.26"(D) x 0.39") To attach the ENH710EXT to a wall using wall mounting kit. 1. Mark the four locations of the mounting holes on the flat mounting surface. 3. Place the lock and flat washers on the four hex cap screws and drive the screws to attach the bracket to the back of the Access Point. 2. Drill a 37 mm deep 8 mm hole in the markings and hammer the bolts into the openings. 4. Tighten the flat washers to secure the bracket to the mounting surface. 3. 1. 2. 4. 17 To attach the ENH710EXT to a pole using the provided pole mounting kit: tabs on the Pole Mount Bracket . 4. Lock and tighten the Pole Strap to secure the Pole Mount Bracket to the pole. 1. Place the lock and flat washers on the four hex cap screws and drive the screws to attach the bracket to the back of the Access Point. Note: See diagram below for vertical and horizonal placements. 2. Drive the four round head screws to attach the Pole Mount Bracket to the bracket. 3. Thread the open end of the Pole Strap through the two vertical placement horizontal placement 18 To install the ground cable on the ENH710EXT 1. Use the attached screws to pass the ground cable as shown in the figure below. 2. Assemble the ground cable on the device. Length: 1.8m (5.9”) 19 Chapter 3 Configuring Your Access Point 20 Configuring Your Access Point 2. The default username and password are admin. Once you have entered the correct username and password, click the Login button to open the web-base configuration page. This section will show you how to configure the device using the web-based configuration interface. Default Settings Please use your Ethernet port or wireless network adapter to connect the Access Point. IP Address 192.168.1.1 Username / Password admin / admin Web Configuration 1. Open a web browser (Internet Explorer/Firefox/Safari/ Chrome) and enter the IP Address http://192.168.1.1 3. If successful, you will be logged in and see the ENH710EXT User Interface. Note: If you have changed the default LAN IP Address of the Access Point, ensure you enter the correct IP Address. 21 Chapter 4 Building a Wireless Network 22 The ENH710EXT has the ability to operate in various modes. This chapter describes the operating modes of the ENH710EXT. Access Point Mode In Access Point Mode, ENH710EXT behaves likes a central connection for stations or clients that support IEEE 802.11a/b/g/n networks. The stations and clients must be configured to use the same SSID (Service Set Identifier) and security password to associate with the ENH710EXT. The ENH710EXT supports up to eight (8) SSIDs per band at the same time for secure access. 23 Client Bridge Mode The ENH710EXT essentially acts as a wireless adapter that connects to an access point to allow a system of wireless access to the network in the Client Bridge mode. Since the computers are on the same subnet, the ENH710EXT can broadcast to reach all end-devices. If you use the client bridge mode in the ENH710EXT, you can use the AP Detection feature to scan for Access Points within range. When you find an Access Point, configure the ENH710EXT to use the same SSID and Security Password as the Access Point to associate with it. 24 WDS AP Mode The ENH710EXT also supports WDS AP mode. This operating mode allows wireless connections to the ENH710EXT using WDS technology. In this mode, configure the MAC addresses in both Access Points to enlarge the wireless area by enabling WDS Link settings. WDS supports up to four (4) AP MAC addresses. 25 WDS Bridge Mode In WDS Bridge Mode, the ENH710EXT can wirelessly connect different LANs by configuring the MAC address and security settings of each ENH710EXT device. Use this mode when two wired LANs located a small distance apart want to communicate with each other. The best solution is to use the ENH710EXT to wirelessly connect two wired LANs, as shown in the following diagram. WDS Bridge Mode can establish up to four WDS links, creating a star-like network. Note: WDS Bridge Mode does not act as an Access Point. Access Points linked by WDS are using the same frequency channel. More Access Points connected together may lower throughput. This configuration can be susceptible to generate endless network loops in your network, so it is recommended to enable the Spanning Tree function to prevent this from happening. 26 WDS Station Mode Station mode expands the WDS by receiving a wireless signal/service and sharing it through the Ethernet port. 27 Chapter 5 Status 28 Main Status Save Changes Device Status This page lets you save and apply the settings shown under Unsaved changes list, or cancel the unsaved changes and revert to the previous settings that were in effect. Clicking the Device Status link under the Overview menu shows the status information about the current operating mode. • The Device Information section shows general system information such as Device Name, MAC Address, Current Time, Firmware Version, and Management VLAN ID Note: VLAN ID information is only applicable in Access Point or WDS AP mode. 29 • The LAN Information section shows the Local Area Network settings such as the LAN IP Address, Subnet mask, and DNS Address. SSID, MAC address, RX and TX. • The Wireless LAN Information 2.4 GHz/5 GHz section shows wireless information such as Operating Mode, Frequency, and Channel. Since the ENH710EXT supports multiple-SSIDs, information about each SSID, the ESSID, and security settings, are displayed Note: Profile Settings are only applicable in Access Point and WDS AP modes. • The Statistics section shows Mac information such as 30 Connection 2.4 GHz/5 GHz Connection List 2.4 GHz/5 GHz WDS Link List Click the connection link under the Overview menu displays the connection list of clients associated to the ENH710EXT’s 2.4 GHz/5 GHz, along with the MAC addresses and signal strength for each client. Clicking Refresh updates the client list. Click the connection link under the Overview menu. This page displays the current status of the WDS link, including WDS Link ID, MAC Address, Link Status and RSSI. Note: Only applicable in WDS AP and WDS Bridge modes. Note: Only applicable in Access Point and WDS AP modes. 31 Client Bridge Connection Status Click the connection link under the Overview menu. This page displays the connection status between Access Point, including associated SSID, BSSID, connection status, wireless mode, current channel, security, Tx Data Rate(Mbps), Current noise level and signal strength. 32 Chapter 6 Network 33 Basic IP Settings IPv4/IPv6 Settings IP Network Settings: Select whether the device IP address will use a static IP address specified in the IP address field or be obtained automatically when the device connects to a DHCP server. This page allows you to modify the device’s IP settings. IP Address: The IP address of this device. Subnet Mask: The IP Subnet mask of this device. Gateway: The Default Gateway of this device. Leave it blank if you are unsure of this setting. Primary/Secondary DNS: The primary/secondary DNS address for this device. Save: Click Save to confirm the changes. 34 Spanning Tree Protocol (STP) Settings This page allows you to modify the Spanning Tree settings. Enabling the Spanning Tree protocol will prevent network loops in your LAN network. Spanning Tree Status: Enables or disables the Spanning Tree function. Hello Time: Specifies Bridge Hello Time in seconds. This value determines how often the device sends handshake packets to communicate information about the topology throughout the entire Bridged Local Area Network. Max Age: Specifies Bridge Max Age in seconds. If another bridge in the spanning tree does not send a hello packet for a long period of time, it is assumed to be inactive. Forward Delay: Specifies Bridge Forward Delay in seconds. Forwarding delay time is the time spent in each of the Listening and Learning states before the Forwarding state is entered. This delay is provided so that when a new bridge comes onto a busy network, it analyzes data traffic before participating in the network. Priority: Specifies the Priority Number. A smaller number has a greater priority than a larger number. Save: Click Save to confirm the changes. 35 Chapter 7 2.4 GHz & 5 GHz Wireless 36 Wireless Wireless Settings Device Name: Enter a name for the device. The name you type appears in SNMP management. This name is not the SSID and is not broadcast to other devices. Band Steering: Enable Band Steering to send 802.11n clients to the 5 GHz band, where 802.11b/g clients cannot go, and leave 802.11b/g clients in 2.4GHz to operate at their slower rates. Band Steering works within the Access Point by directing 5 GHz-capable clients to that band. Save: Click Save to confirm the changes. 37 This page displays the current status of the Wireless settings of the ENH710EXT. Extension Channel: Select the upper or lower channel. Your selection may affect the Auto channel function. 2.4 GHz/5 GHz Wireless Network Channel: Select the approriate channel and frequency. Select Auto to enable auto-channel selection. Transmit Power: Sets the power output of the wireless signal. Data Rate: Select a data rate from the drop-down list. The data rate affects throughput of data in the ENH710EXT. Select the best balance for you and your network but note that the lower the data rate, the lower the throughput, though transmission distance is also lowered. RTS/CTS Threshold: Specifies the threshold package size for RTC/CTS. A small number causes RTS/CTS packets to be sent more often and consumes more bandwidth. Operation Mode: Select Operation Mode. The ENH220EXT supports multi-operation modes: Access Point, Client Bridge, or WDS(WDS AP, WDS Bridge, and WDS Station). Client Limits: Limits the total number of clients. Wireless Mode: Supports 802.11b/g/n mixed mode in 2.4 GHz and 802.11a/n mixed mode in 5 GHz. Aggregation: Merges data packets into one packet. This option reduces the number of packets, but also increases packet sizes. Channel HT Mode: The default channel bandwidth is 20 MHz/ 40 MHz. The larger the channel, the greater the transmission quality and speed. AP Detection: AP Detection can select the best channel to use by scanning nearby areas for Access Points. 38 Distance: Specifies the distance between Access Points and clients. Note that longer distances may drop higherspeed connections. Save: Click Save to confirm the changes or Cancel to cancel and return to previous settings. 39 2.4 GHz/5 GHz SSID Profile Current Profile: You can configure up to sixteen (16) different SSIDs (eight (8) per band). If multiple client devices will be accessing the network, you can arrange the devices into SSID groups. Click Edit to configure the profile and check whether you want to enable extra SSID. SSID: Specifies the SSID for the current profile. Suppressed SSID: Check this option to hide the SSID from clients. If checked, the SSID will not appear in the site survey. Station Separation: Click the appropriate radio button to allow or prevent communication between client devices. VID: Specifies the VLAN tag for each profile. If your netowrk includes VLANs, you can specify a VLAN ID for packets pass through the Access Point with a tag. Wireless Security: See the Wireless Security section. Isolation: Restrict clients communicating with different VIDs by selecting the radio button. Save: Click Save to accept the changes. 40 Wireless Security Auth Type: Select Open System or Shared Key. The Wireless Security section lets you configure the ENH710EXT’s security modes: WEP, WPA-PSK, WPA2-PSK, WPA-PSK Mixed, WPA, WPA2, and WPA Mixed. It is strongly recommend that you use WPA2-PSK. Input Type: ASCII: Regular Text (recommended) Hexadecimal Numbers (For advanced users) Key Length: Select the desired option and ensure that wireless clients use the same setting. Your choices are 64, 128, and 152-bit password lengths. Default Key: Select the Key you wish to be the default. Transmitted data is ALWAYS encrypted using the Default Key; the other Keys are for decryption only. You must enter a Key Value for the Default Key. Encryption Key Number: Enter the Key Value or values you wish to use. Only the Key selected as Default is required. The others are optional. 41 Wireless MAC Filtering Wireless MAC Filtering is used to allow or deny network access to wireless clients (computers, tablet PCs, NAS, smartphones, etc.) according to their MAC addresses. You can manually add a MAC address to restrict permission to access the ENH710EXT. The default setting is: Disable Wireless MAC Filter. ACL Mode: Determines whether network access is granted or denied to clients whose MAC addresses appear in the MAC address table on this page. Your choices are: Disabled, Deny MAC in the list, or Allow MAC in the list. Note: Only applicable in Access Point and WDS AP modes. Add: Click Add to add the MAC address to the MAC address table. MAC Address: Enter the MAC address of the wireless client. Delete: Delete the selected entries. Save: Click Save to apply the changes. 42 Wireless Advanced WPA-PSK (WPA Pre-Shared Key) Encryption: Wireless Traffic Shaping Traffic shaping regulates the flow of packets leaving an interface to deliver improved Quality of Service. Encryption: Select the WPA encryption type you would like. Please ensure that your wireless clients use the same settings. Passphrase: Wireless clients must use the same Key to associate the device. If using ASCII format, the Key must be from 8 to 63 characters in length. If using HEX format, the Key must be 64 HEX characters in length. Enable Traffic Shaping: Check this option to enable Wireless Traffic Shaping. Download Limit: Specifies the wireless transmission speed used for downloading. Group Key Update Interval: Specifies how often, in seconds, the Group Key changes. Upload Limit: Specifies the wireless transmission speed used for uploading. Save: Click Save to confirm the changes. 43 WPA Mixed-Enterprise: Access Point / WDS AP mode Group Key Update Interval: Specifies how often, in seconds, the Group Key changes. Radius Accounting: Enable or disable accounting feature. Radius Accounting Server: Enter the IP address of the Radius accounting server. Radius Accounting Port Enter the port number used for connections to the Radius accounting server. Radius Accounting Secret: Enter the secret required to connect to the Radius accounting server. Interim Accounting Interval: Specifies how often, in seconds, the accounting data sends. Note: 802.11n does not allow WEP/WPA-PSK TKIP/ WPA2-PSK TKIP security mode. The connection mode will automatically change from 802.11n to 802.11g. Encryption: Select the WPA encryption type you would like. Please ensure that your wireless clients use the same settings. Radius Server: Enter the IP address of the Radius server. Fast Roaming: Enable Fast Roaming to serve mobile client devices that roam from Access Point to Access Point. Some applications running on Client devices require fast reassociation when they roam to a different Access Point. Voice application. Radius Port: Enter the port number used for connections to the Radius server. Radius Secret: Enter the secret required to connect to the Radius server. 44 WDS Link Settings 2.4 GHz/5 GHz WDS Link Settings Using the WDS (Wireless Distribution System) feature will allow a network administrator or installer to connect to Access Points wirelessly. Doing so will extend the wired infrastructure to locations where cabling is not possible or inefficient to implement. Note: Compatibility between different brands and models of Access Points is not guaranteed. It is recommended that the WDS network be created using the same models for maximum compatibility. Also note: All Access Points in the WDS network need to use the same Channel and Security settings. Security: Select None or AES from the drop-down list. To create a WDS network, please enter the MAC addresses of the Access Points that you want included in the WDS. There can be a maximum of four Access Points. AES Passphrase: Enter the Key Values you wish to use. Other Access Points must use the same Key to establish a WDS link. Note: Only applicable in WDS AP and WDS Bridge modes. MAC Address: Enter the Access Point’s MAC address to where you want to extend the wireless area. Mode: Select to disable or enable from the drop-down list. Save: Click Save to confirm the changes. 45 Client Bridge Setting Security Mode: Select the correct security mode and insert the correct encryption type. Please refer the wireless security section in page 42. No.: Display the setting value Save: Click Save to accept the changes SSID: You can implement the AP detection to select the proper SSID. Edit: Click it to implement the advanced settings Prefer BSSID: You can insert the prefer BSSID or enter the specific SSID to be associated with the Access Point. SSID: You can implement the AP detection to select the proper SSID. 46 Guest Network Settings Ending IP Address: The last IP Address in the range of addresses assigned by the DHCP server. Adding a guest network allows visitors to use the Internet without giving out your office or company wireless security key. You can add a guest network to each wireless network in the 2.4 GHzb/g/n and 5 GHza/n frequencies. Fast Handover Fast Handover: Enable the Fast Handover feature by ensuring that each client is served by at least one Access Point at any time. Access Points continuously monitor the connectivity quality of any client in their range and efficiently share this information with other Access Points in the vincinity of that client to coordinate which of them should serve the client best. SSID: Specifies the SSID for the current profile. Suppressed SSID: Check this option to hide the SSID from clients. If checked, the SSID will not appear in the site survey. RSSI: Enter the RSSI (Received Signal Strength Index) in order to determine the handover procedure which the current wireless link will terminate. RSSI is an indication of the power level being received by the antenna. Therefore, the higher the RSSI number, the stronger the signal. Station Separation: Click the appropriate radio button to allow or prevent communication between client devices. IP Address: The IP Address of this device. Subnet Mask: The IP Subnet mask of this device. Starting IP Address: The first IP Address in the range of the addresses by the DHCP server. 47 Chapter 8 Management 48 Management VLAN Settings Management VLAN: If your network includes VLANs, you can enable Management VLAN ID for packets passing through the Access Point with a tag. This page allows you to assign a VLAN tag to packets sent over the network. A VLAN is a group of computers on a network whose software has been configured so that they behave as if they were on a separate Local Area Network (LAN). Computers on VLAN do not have to be physically located next to one another on the LAN. Save: Click Save to confirm the changes or Cancel to cancel and return to previous settings. Note: If you reconfigure the Management VLAN ID, you may lose your connection to the ENH710EXT. Verify that the DHCP server supports the reconfigured VLAN ID and then reconnect to the ENH710EXT using the new IP address. Note: Only applicable in Access Point and WDS AP modes. 49 Advanced Settings SNMP Settings Location: Specifies the location of the device. This page allows you to assign the Contact Details, Location, Community Name, and Trap Settings for a Simple Network Management Protocol (SNMP). SNMP is a networking management protocol used to monitor network attached devices. SNMP allows messages (called protocol data units) to be sent to various parts of the network. Upon receiving these messages, SNMP compatible devices (called agents) returns the data stored in their Management Information Bases. Community Name (Read Only): Specifies the password for the SNMP community for read only access. Community Name (Read/Write): Specifies the password for the SNMP community with read/write access. Trap Destination Address: Specifies the IP address of the computer that will receive the SNMP traps. Trap Destination Community Name: Specifies the password for the SNMP trap community. SNMPv3: Enables or disables the SNMPv3 feature. User Name: Specifies the username for SNMPv3. Auth Protocol: Selects the authentication protocol type: MDS or SHA. Auth Key: Specifies the authentication key. Priv Protocol: Selects the privacy protocol type: DES. Priv Key: Specifies the privacy key for privacy. Engine ID: Specifies the engine ID for SNMPv3. SNMP Enable/Disable: Enables or disables the SNMP feature. Apply Save: Click Apply Save to apply the changes. Contact: Specifies the contact details of the device. 50 CLI Settings Email Alert You can use the Email Alert feature to send messages to the configured email address when particular system events occur. Note: Do NOT use your personal email address as it can unnecessarily expose your personal email login credentials. Use a separate email account made for this feature instead CLI: The Command Line Interface (CLI) allows you to type commands instead of choosing them from a menu or selecting an icon. SSH: Enable Secure Shell (SSH) to make secure, encrypted connections in the network. Secure Shell is a network protocol that allows data to be exchanged using a secure channel between two network devices. HTTPS: Enable HTTPS to transfer and display web content securely. The Hypertext Transfer Protocol over SSL (Secure Socket Layer) is a TCP/IP protocol used by web servers to transfer and display web content securely. From: Enter the email address to show the sender of the email. To: Enter the address that you wish to send emails to. Subject: Enter the text that you wish to appear in the email’s subject line. 51 Username: Enter the username for the email account that will be used to send emails. Password: Enter the password for the email account that will be used to send emails. SMTP Server: Enter the IP address or hostname of the outgoing SMTP server. Port: Enter the SMTP port number to use for outbound emails. 52 Time Zone Time Setting Start: Select the day, month, and time when daylight savings time starts. This page allows you to set the internal clock of the ENH710EXT. End: Select the day, month, and time when daylight savings times ends. Manually Set Date and Time: Manually specify the date and time. Automatically Get Date and Time: Select and check whether you wish to enter the IP address of an NTP server or use the default NTP server to have the internal clock set automatically. Enable Daylight Saving: Check whether daylight savings applies to your area. 53 Auto Reboot Settings You can specify how often you wish to reboot the ENH710EXT. Auto Reboot Setting: Enables or disables the Auto Reboot function. Frequency of Auto Reboot: Specifies how often you wish to reboot the ENH710EXT by Min, Hour, Day or Week. Timer: Select the day and enter the time you would like to reboot automatically. Save: Click Save to apply the changes. 54 Wi-Fi Scheduler drop-down list. The Wi-Fi Scheduler can be created for use in enforcing rules. For example, if you wish to restrict web access to Mon-Fri from 3pm to 8pm, you could create a schedule selecting Mon, Tue, Wed, Thu and Fri while entering a Start time of 3pm and End Time of 8pm to limit access to these times. Day(s): Place a checkmark in the boxes for the desired days or select the All Week radio button to select all seven days of the week. Duration: The Start Time is entered in two fields. The first box is for hours and the second box is for minutes. The End Time is entered in the same format as the Start time. Status: Enables or disables the Wi-Fi scheduler function. Wireless Radio: Select 2.4 GHz or 5 GHz from the dropdown list for the preferred band type. SSID Selection: Select a SSID from the drop-down list. Schedule Templates: Select a schedule template from the 55 Tools Ping Test Parameters Start Ping: Click Start Ping to begin pinging the target device (via IP). This page allows you to analyze the connection quality of the ENH710EXT and trace the routing table to a target in the network. Traceroute Target: Enter the IP address or domain name you wish to trace. Start Traceroute: Click Start Traceroute to begin the trace route operation. Target IP: Enter the IP address you would like to search. Ping Packet Size: Enter the packet size of each ping. Number of Pings: Enter the number of times you wish to ping. 56 Speed Test Parameters / LED Control indicator. This page allows you to control LED on/off for Power, LAN interface, or 2.4 GHz/5 GHz WLAN interface. WLAN-5 GHz: Enables or disables the WLAN-5 GHz LED indicator. Device Discovery This page allows you to discover devices from network for Operation Mode, IP Address, System MAC Address and Firmware version. LED Control Power: Enables or disables the Power LED indicator. LAN: Enables or disables the LAN LED indicator. WLAN-2.4 GHz: Enables or disables the WLAN-2.4 GHz LED 57 Account Firmware This page allows you to change the ENH710EXT username and password. By default, the username is: admin and the password is: admin. The password can contain from 0 to 12 alphanumeric characters and is case sensitive. Firmware Upgrade This page allows you to upgrade the firmware of the ENH710EXT. Account Settings To Perform the Firmware Upgrade: 1. Click the Choose File button and navigate the OS file system to the location of the upgrade file. Administrator Username: Enter a new username for logging in to the New Name entry box. 2. Select the upgrade file. The name of the file will appear in the Upgrade File field. Current Password: Enter the old password for logging in to the Old Password entry box. 3. Click the Upload button to commence the firmware upgrade. New Password: Enter the new password for logging in to the New Password entry box. Note: The device is unavailable during the Firmware upgrade process and must restart when the upgrade is completed. Any connections to or through the device will be lost. Verify Password: Re-enter the new password in the Confirm Password entry box for confirmation. Apply: Click Apply to apply the changes. 58 Backup/Restore Factory Setting Backup Setting: Click Export to save the current configured settings. The function allows you to export the current device configurations. When you export your configurations, you also can reload the saved configurations into the device through the Restore Saved Settings from a file section. If extreme problems occur, or if you have set the ENH710EXT incorrectly, you can use the Reset button in the Revert to Factory Default Settings section to restore all the configurations of the ENH710EXT to the original default settings. Restore New Setting: To restore settings that have been previously backed up, click Browse, select the file, and click Restore. Restore to Default: Click Reset button to restore the ENH710EXT to its factory default settings. 59 User Setting Back Up Setting as Default: Click Backup to backup the user settings you would like to the device’s memory for the default settings. The function allows you to backup the current device configurations into the ENH710EXT as the default value. If extreme problems occur, or if you have set the ENH710EXT incorrectly, you can push the Reset button to revert all the configurations of the ENH710EXT to the user default. Restore to User Default: Click Restore to restore user settings to the factory standard settings. Note1: After setting the current settings as the default, you should click the Restore to Default on the web interface for reverting the settings into the factory default instead of pushing the reset button. Note2: Please write down your account and password before saving. The user settings will now become the new default settings at the next successful login. 60 Log System Log Remote Log The ENH710EXT automatically logs (records) events of possible interest in its internal memory. To view the logged information, click the Log link under the System Manager menu. If there is not enough internal memory to log all events, older events are deleted from the log. When powered down or rebooted, the log will be cleared. This page allows you to setup the Remote Log functions for the ENH710EXT. Syslog: Enables or disables the syslog function. Log Server IP Address: Enter the IP address of the log server. Remote Log: Enable or disable the remote log service. Apply: Click Apply to apply the changes. 61 Logout Reset Click Logout in Management menu to logout. In some circumstances, it may be required to force the device to reboot. Click on Reset to reboot the ENH710EXT. 62 Appendix 63 Appendix A Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. IMPORTANT NOTE: Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20 cm between the radiator & your body. 64 Appendix B - CE Interference Statement Europe – EU Declaration of Conformity This device complies with the essential requirements of the R&TTE Directive 1999/5/EC. The following test methods have been applied in order to prove presumption of conformity with the essential requirements of the R&TTE Directive 1999/5/EC: • EN60950-1 Safety of Information Technology Equipment • EN50385 Generic standard to demonstrate the compliance of electronic and electrical apparatus with the basic restrictions related to human exposure to electromagnetic fields (0 Hz - 300 GHz) • EN 300 328 Electromagnetic compatibility and Radio spectrum Matters (ERM); Wideband Transmission systems; Data transmission equipment operating in the 2,4 GHz ISM band and using spread spectrum modulation techniques; Harmonized EN covering essential requirements under article 3.2 of the R&TTE Directive • EN 301 893 Broadband Radio Access Networks (BRAN); 5 GHz high performance RLAN; Harmonized EN covering essential requirements of article 3.2 of the R&TTE Directive • EN 301 489-1 Electromagnetic compatibility and Radio Spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common technical requirements • EN 301 489-17 Electromagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 17: Specific conditions for 2,4 GHz wideband transmission systems and 5 GHz high performance RLAN equipment 65 This device is a 5GHz wideband transmission system (transceiver), intended for use in all EU member states and EFTA countries, except in France and Italy where restrictive use applies. In Italy the end-user should apply for a license at the national spectrum authorities in order to obtain authorization to use the device for setting up outdoor radio links and/or for supplying public access to telecommunications and/or network services. This device may not be used for setting up outdoor radio links in France and in some areas the RF output power may be limited to 10 mW EIRP in the frequency range of 2454 – 2483.5 MHz. For detailed information the end-user should contact the national spectrum authority in France. Česky [Czech] [Jméno výrobce] tímto prohlašuje, že tento [typ zařízení] je ve shodě se základními požadavky a dalšími příslušnými ustanoveními směrnice 1999/5/ES. Dansk [Danish] Undertegnede [fabrikantens navn] erklærer herved, at følgende udstyr [udstyrets typebetegnelse] overholder de væsentlige krav og øvrige relevante krav i direktiv 1999/5/EF. Deutsch [German] Hiermit erklärt [Name des Herstellers], dass sich das Gerät [Gerätetyp] in Übereinstimmung mit den grundlegenden Anforderungen und den übrigen einschlägigen Bestimmungen der Richtlinie 1999/5/EG befindet. Eesti [Estonian] Käesolevaga kinnitab [tootja nimi = name of manufacturer] seadme [seadme tüüp = type of equipment] vastavust direktiivi 1999/5/EÜ põhinõuetele ja nimetatud direktiivist tulenevatele teistele asjakohastele sätetele. English Hereby, [name of manufacturer], declares that this [type of equipment] is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. Español [Spanish] Por medio de la presente [nombre del fabricante] declara que el [clase de equipo] cumple con los requisitos esenciales y cualesquiera otras disposiciones aplicables o exigibles de la Directiva 1999/5/CE. Ελληνική [Greek] ΜΕ ΤΗΝ ΠΑΡΟΥΣΑ [name of manufacturer] ΔΗΛΩΝΕΙ ΟΤΙ [type of equipment] ΣΥΜΜΟΡΦΩΝΕΤΑΙ ΠΡΟΣ ΤΙΣ ΟΥΣΙΩΔΕΙΣ ΑΠΑΙΤΗΣΕΙΣ ΚΑΙ ΤΙΣ ΛΟΙΠΕΣ ΣΧΕΤΙΚΕΣ ΔΙΑΤΑΞΕΙΣ ΤΗΣ ΟΔΗΓΙΑΣ 1999/5/ΕΚ. 66 Français [French] Par la présente [nom du fabricant] déclare que l’appareil [type d’appareil] est conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999/5/CE. Italiano [Italian] Con la presente [nome del costruttore] dichiara che questo [tipo di apparecchio] è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1999/5/CE. Latviski [Latvian] Ar šo [name of manufacturer / izgatavotāja nosaukums] deklarē, ka [type of equipment / iekārtas tips] atbilst Direktīvas 1999/ 5/EK būtiskajām prasībām un citiem ar to saistītajiem noteikumiem. Lietuvių [Lithuanian] Šiuo [manufacturer name] deklaruoja, kad šis [equipment type] atitinka esminius reikalavimus ir kitas 1999/5/EB Direktyvos nuostatas. Nederlands [Dutch] Hierbij verklaart [naam van de fabrikant] dat het toestel [type van toestel] in overeenstemming is met de essentiële eisen en de andere relevante bepalingen van richtlijn 1999/5/EG. Malti [Maltese] Hawnhekk, [isem tal-manifattur], jiddikjara li dan [il-mudel tal-prodott] jikkonforma mal-ħtiġijiet essenzjali u ma provvedimenti oħrajn relevanti li hemm fid-Dirrettiva 1999/5/EC. Magyar [Hungarian] Alulírott, [gyártó neve] nyilatkozom, hogy a [... típus] megfelel a vonatkozó alapvetõ követelményeknek és az 1999/5/EC irányelv egyéb elõírásainak. Polski [Polish] Niniejszym [nazwa producenta] oświadcza, że [nazwa wyrobu] jest zgodny z zasadniczymi wymogami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999/5/EC. Português [Portuguese] [Nome do fabricante] declara que este [tipo de equipamento] está conforme com os requisitos essenciais e outras disposições da Directiva 1999/5/CE. Slovensko [Slovenian] [Ime proizvajalca] izjavlja, da je ta [tip opreme] v skladu z bistvenimi zahtevami in ostalimi relevantnimi določili direktive 1999/5/ES. Slovensky [Slovak] [Meno výrobcu] týmto vyhlasuje, že [typ zariadenia] spĺňa základné požiadavky a všetky príslušné ustanovenia Smernice 1999/5/ES. Suomi [Finnish] [Valmistaja = manufacturer] vakuuttaa täten että [type of equipment = laitteen tyyppimerkintä] tyyppinen laite on direktiivin 1999/5/EY oleellisten vaatimusten ja sitä koskevien direktiivin muiden ehtojen mukainen. 67 Appendix C - IC Interference Statement Industry Canada statement This device complies with RSS-210 of the Industry Canada Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Ce dispositif est conforme à la norme CNR-210 d’Industrie Canada applicable aux appareils radio exempts de licence. Son fonctionnement est sujet aux deux conditions suivantes: (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. IC Caution: High-power radars are allocated as primary users (i.e. priority users) of the bands 5250-5350 MHz and 5650-5850 MHz and that these radars could cause interference and/or damage to LE-LAN devices. Avertissement: De plus, les utilisateurs devraient aussi être avisés que les utilisateurs de radars de haute puissance sont désignés utilisateurs principaux (c.-à-d., qu’ils ont la priorité) pour les bandes 5250-5350 MHz et 5650-5850 MHz et que ces radars pourraient causer du brouillage et/ou des dommages aux dispositifs LAN-EL. IMPORTANT NOTE: Radiation Exposure Statement This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 25cm between the radiator & your body. Déclaration d’exposition aux radiations Cet équipement est conforme aux limites d’exposition aux rayonnements IC établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20cm de distance entre la source de rayonnement et votre corps. 68 Appendix D - Professional Installation Instruction Installation Personal This product is designed for specific application and needs to be installed by a qualified personal who has RF and related rule knowledge. The general user shall not attempt to install or change the setting. Installation Location The product shall be installed at a location where the radiating antenna can be kept 20cm from nearby person in normal operation condition to meet regulatory RF exposure requirement. External Antenna Use only the antennas which have been approved by the applicant. The non-approved antenna(s) may produce unwanted spurious or excessive RF transmitting power which may lead to the violation of FCC/IC limit and is prohibited. Installation Procedure Please refer to user’s manual for the detail. Warning: Please carefully select the installation position and make sure that the final output power does not exceed the limit set force in relevant rules. The violation of the rule could lead to serious federal penalty. 69 Appendix E - Instructions d’installation professionnelle Installation CCe produit est destine a un usage specifique et doit etre installe par un personnel qualifie maitrisant les radiofrequences et les regles s’y rapportant. L’installation et les reglages ne doivent pas etre modifies par l’utilisateur final.final. Emplacement d’installation En usage normal, afin de respecter les exigences reglementaires concernant l’exposition aux radiofrequences, ce produit doit etre installe de facon a respecter une distance de 20cm entre l’antenne emettrice et les personnes. Antenn externe Utiliser uniiquement les antennes approuvees par le fabricant. L’utilisation d’autres antennes peut conduire a un niveau de rayonnement essentiel ou non essentiel depassant les niveaux limites definis par FCC/IC, ce qui est interdit. Procedure d’installation Consulter le manuel d’utilisation. Avertissement: Choisir avec soin la position d’installation et s’assurer que la puissance de sortie ne depasse pas les limites en vigueur. La violation de cette regle peut conduire a de serieuses penalites federales. 70 Appendix F - Detachable Antenna Usage This device has been designed to operate with an antenna having a maximum gain of 7 dB. Antenna having a higher gain is strictly prohibited per regulations of Industry Canada. The required antenna impedance is 50 ohms. Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. This radio transmitter (IC: 10103A-ENH710EXT / Model: ENH710EXT) has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device. Ce dispositif a été conçu pour fonctionner avec une antenne ayant un gain maximal de dB 7. Une antenne à gain plus élevé est strictement interdite par les règlements d’Industrie Canada. L’impédance d’antenne requise est de 50 ohms. Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peutfonctionner avec une antenne d’un type et d’un gain maximal (ou inférieur) approuvé pourl’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectriqueà l’intention des autres utilisateurs, il faut choisir le type d’antenne et son gain de sorte que lapuissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité nécessaire àl’établissement d’une communication satisfaisante. Le présent émetteur radio (IC: 10103A-ENH710EXT / Model: ENH710EXT) a été approuvé par Industrie Canada pour fonctionner avec les types d’antenne énumérés ci-dessous et ayant un gain admissible maximal et l’impédance requise pour chaque type d’antenne. Les types d’antenne non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l’exploitation de l’émetteur. Approved Antenna(s) List Type : Dipole Gain : 5dBi for 2.4GHz / 7dBi for 5GHz 71
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Warning : Invalid xref tableEXIF Metadata provided by EXIF.tools