EnOcean PTM215Z 2405 MHz - 2480 MHz transmitter User Manual

EnOcean GmbH 2405 MHz - 2480 MHz transmitter

Contents

User Manual

Download: EnOcean PTM215Z 2405 MHz - 2480 MHz transmitter User Manual
Mirror Download [FCC.gov]EnOcean PTM215Z 2405 MHz - 2480 MHz transmitter User Manual
Document ID2326615
Application IDehQPkIw7I/hNduiWfTnANw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize50.98kB (637236 bits)
Date Submitted2014-07-16 00:00:00
Date Available2014-07-16 00:00:00
Creation Date2014-06-10 16:55:33
Producing SoftwareMicrosoft® Office Word 2007
Document Lastmod2014-06-10 16:55:33
Document TitleUser Manual
Document CreatorMicrosoft® Office Word 2007
Document Author: Product Marketing

USER MANUAL V1.0
Pushbutton Transmitter Device
PTM 215 ZGPGP
June 10, 2014
Patent protected:
US 6,747,573
US 7,019,241
Further patents pending
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 1/18
USER MANUAL V1.0
PTM 215ZGP
REVISION HISTORY
The following major modifications and improvements have been made to the first version of
this document:
No
1.0
Major Changes
Initial Release
Published by EnOcean GmbH, Kolpingring 18a, 82041 Oberhaching, Germany
www.enocean.com, info@enocean.com, phone ++49 (89) 6734 6890
© EnOcean GmbH
All Rights Reserved
Important!
This information describes the type of component and shall not be considered as assured
characteristics. No responsibility is assumed for possible omissions or inaccuracies. Circuitry
and specifications are subject to change without notice. For the latest product specifications, refer to the EnOcean website: http://www.enocean.com.
As far as patents or other rights of third parties are concerned, liability is only assumed for
devices, not for the described applications, processes and circuits.
EnOcean does not assume responsibility for use of devices described and limits its liability
to the replacement of devices determined to be defective due to workmanship. Devices or
systems containing RF components must meet the essential requirements of the local legal
authorities.
The devices must not be used in any relation with equipment that supports, directly or indirectly, human health or life or with applications that can result in danger for people, animals or real value.
Components of the devices are considered and should be disposed of as hazardous waste.
Local government regulations are to be observed.
Packing: Please use the recycling operators known to you. By agreement we will take packing material back if it is sorted. You must bear the costs of transport. For packing material
that is returned to us unsorted or that we are not obliged to accept, we shall have to invoice you for any costs incurred.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 2/18
USER MANUAL V1.0
PTM 215ZGP
TABLE OF CONTENT
GENERAL DESCRIPTION.................................................................................... 4
1.1
Basic Functionality ........................................................................................... 4
1.2
Typical Applications .......................................................................................... 5
1.3
Technical Data ................................................................................................. 5
1.4
Mechanical Interface......................................................................................... 5
1.5
Environmental Conditions................................................................................ 10
1.6
Ordering Information ...................................................................................... 10
FUNCTIONAL DESCRIPTION............................................................................. 11
2.1
Block Diagram ............................................................................................... 11
2.2
Contact Nipples Designation ............................................................................ 12
2.3
Operating modes ........................................................................................... 12
2.3.1
Normal Mode .............................................................................................. 13
2.3.1.1
Security Parameters ................................................................................. 14
2.3.2
Commissioning Mode ................................................................................... 15
2.3.2.1
Radio Channel Selection............................................................................ 15
2.3.2.2
Join Request............................................................................................ 15
2.4
Construction of application specific Switch Rockers ............................................. 16
2.5
Device Mounting ............................................................................................ 16
2.6
Regulatory Notes ........................................................................................... 17
2.6.1
FCC Regulatory Statement ........................................................................... 17
Transmission Range ....................................................................................... 18
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 3/18
USER MANUAL V1.0
PTM 215ZGP
GENERAL DESCRIPTION
The radio transmitter device PTM 215ZGP from EnOcean enables the implementation of
wireless remote controls without batteries. Power is provided by a built-in electro-dynamic
power generator. The PTM 215ZGP device transmits data based on the 2.4GHz ZigBee
Green Power standard.
The outer appearance of PTM 215ZGP is shown on the picture below.
(1) Energy bow
on both device sides
(2) Contact nipples
for switch rocker
identification
Rotation axis for
pushbuttons or
switch rocker
Electro-dynamic powered radio transmitter device PTM 215ZGP
1.1
Basic Functionality
PTM 215ZGP devices contain an electro-dynamic energy transducer which is actuated by a
bow (1). This bow is pushed by an appropriate push button, switch rocker or a similar construction mounted onto the device. An internal spring will release the energy bow as soon
as it is not pushed down anymore.
When the energy bow is pushed down, electrical energy is created and a ZigBee Green
Power radio telegram is transmitted. Releasing the energy bow similarly generates energy
which is used to transmit a different ZigBee Green Power radio telegram. It is therefore
possible to distinguish between radio telegrams sent when the energy bar was pushed and
radio telegrams sent when the energy bar was released.
By identifying these different telegrams types and measuring the time between pushing
and releasing of the energy bar, it is possible to distinguish between “Long” and “Short”
push button presses. This enables simple implementation of applications such as dimming
control or blinds control including slat action.
The PTM 215ZGP radio telegram identifies the status (pressed or not pressed) of the four
contact nipples (2) when the energy bow was pushed or released. This enables the implementation of up to two switch rockers or up to four push buttons.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 4/18
USER MANUAL V1.0
PTM 215ZGP
1.2
Typical Applications
Typical applications are found in the following areas:

Building installation

Consumer electronics

Light and door switches
Key products include wall-mounted switches and handheld remote controls supporting up to
two rockers or up to four pushbuttons.
PTM 215ZGP pushbutton transmitters are self-powered (no batteries) and therefore
maintenance-free. They can be used in hermetically sealed systems or in remote (not easily
accessible) locations.
1.3
Technical Data
Power supply
Internal electro-dynamic power generator actuated by the energy bow
Antenna
Internal PCB antenna
Frequency
2.4GHz / IEEE 802.15.4 channels 11 … 26
(User selectable during commissioning)
Data rate
250 kbps (according to IEEE 802.15.4 standard)
Conducted output power
typ. 0dBm
Button inputs
ZigBee Device ID
Up to four buttons
0x02 (ZigBee on / off switch)
Security mode
Unique device security key
Transmission range
typ. 175 m free field / 20 m indoor
Device identifier
1.4
Individual 32-bit ZGPD SrcId (factory programmed)
Mechanical Interface
Device dimensions (inclusive rotation axis and energy bow)
Device weight
40.0 x 40.0 x 11.2 mm
20 g ± 1 g
Energy bow travel / operating force
1.8 mm / typ. 8 N
At room temperature
Only one of the two energy bows may be actuated at the same time!
Restoring force at energy bow
typ. 0.7 N to 4 N
Minimum restoring force of 0.5 N is required for correct operation
Number of operations at 25°C typ. 100.000 actuations tested according to VDE 0632 / EN 60669
Cover material
Hostaform (POM)
Energy bow material
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
PBT (50% GV)
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 5/18
USER MANUAL V1.0
PTM 215ZGP
PTM 215ZGP without antenna, tilted view (including rocker catwalks)
1) these catwalks are not needed when using one single rocker only 2) dimensions of rocker part
PTM 215ZGP, top view (note cut A, B and C marking)
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 6/18
USER MANUAL V1.0
PTM 215ZGP
PTM 215ZGP, cut A
2) dimensions of rocker part
PTM 215ZGP, cut B and C
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 7/18
USER MANUAL V1.0
PTM 215ZGP
Hatched areas: support planes
PTM 215ZGP rear view
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 8/18
USER MANUAL V1.0
PTM 215ZGP
2) dimensions of rocker part
PTM 215ZGP, side view
If the rocker is not mounted on the rotation axis of PTM 215 ZGP several tolerances have to be considered! The measure from support plane to top of the energy
bow is 7.70 mm +/- 0.3 mm!
The movement of the energy bow must not be limited by mounted rockers!
Catwalks of the switch rocker must not exert continuous forces on contact nipples!
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 9/18
USER MANUAL V1.0
PTM 215ZGP
1.5
Environmental Conditions
Operating temperature
Storage temperature
Humidity
1.6
-5 °C up to +45 °C
-25 °C up to +65 °C
0% to 95% r.h., non-condensing
Ordering Information
Type
PTM 215ZGP
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Ordering Code
S3171-A215
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 10/18
USER MANUAL V1.0
PTM 215ZGP
2.1
FUNCTIONAL DESCRIPTION
Block Diagram
Data
Status
Processor
HF
Contact Nipples
Pushed/Released
Ant
DC Power
Energy
Bow
Power
Converter
Block diagram of PTM 215ZGP
Energy Bow / Power Generator
Converts the motion of the energy bow into electrical energy.
Power Converter
Converts the energy of the power generator into a stable DC supply voltage for the device
electronics.
Processor
Determines the status of the contact nipples and the energy bow, encodes this status into a
data word, generates the proper radio telegram structure and sends it to the radio
transmitter.
Radio transmitter
Transmits the data in the form of a series of short ZigBee Green Power radio telegrams.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 11/18
USER MANUAL V1.0
PTM 215ZGP
2.2
Contact Nipples Designation
PTM 215ZGP devices provide four contact nipples. They are grouped into two channels
(Channel A and Channel B) each containing two contact nipples (State O and State I).
The state of all four contact nipples (pressed or not pressed) is transmitted together with a
unique device identification (fixed 32-bit ZGPD SrcId) whenever the energy bow is pushed
or released.
The picture below shows the arrangement of the four nipples and their designation:
STATE
CHANNEL
Contact nipple designation
2.3
Operating modes
PTM 215ZGP supports three operating modes:

Out of the box mode
This is the initial operation mode before PTM 215ZGP has sent a commissioning
telegram.

Normal mode
This is the normal operation mode of PTM 215ZGP.
In this mode, data telegrams are sent according to the button(s) pressed.
The data telegrams are authenticated using the device security key.

Commissioning mode
In this mode, the Radio channel can be changed according to user input and a
“Commissioning” telegram is transmitted in order to commission PTM 215ZGP into
an existing network.
These three operation modes are outlined in more detail in the following chapters.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 12/18
USER MANUAL V1.0
PTM 215ZGP
2.3.1 Out of the Box Mode
PTM 215ZGP operates in “Out of the Box” mode before it has joined an existing network for
the first time via the transmission of a Join request. In this mode, PTM 215ZGP can therefore only communicate without security measures.
The following correspondence between button event and data payload is implemented:
Button Event
Event Type
Command
NONE
Energy Bar only
Press
0x10 (SCENE 0)
Long release (>8s)
Decommissioning
Release
0x14 (SCENE 4)
Press
0x12 (SCENE 2)
Long release (>8s)
Commissioning
Release
0x16 (SCENE 6)
Press
0x11 (SCENE 1)
Release
0x15 (SCENE 5)
Press
0x13 (SCENE 3)
Release
0x17 (SCENE 7)
Press
0x21 (ON)
Release
Press
0x20 (OFF)
Release
A0
A1
B0
B1
A0 and B0
A1 and B1
2.3.1.1
Security Parameters
In Out of the Box mode, PTM 215ZGP transmits data without specific security mechanisms.
The Auto-Commissioning flag is set to 0b1 in this mode for all button actions except the
press of button A1 where it is set to 0b0.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 13/18
USER MANUAL V1.0
PTM 215ZGP
2.3.2 Normal Mode
In normal mode, PTM 215ZGP transmits secure data telegrams reflecting the state of the
four device buttons whenever the energy bar is pressed or released. The state of the four
buttons is encoded in one data byte of payload.
The data telegrams sent when the energy bar is pressed are different from the ones sent
when the energy bar is released.
The following correspondence between button event and data payload is implemented:
Button Event
Event Type
Command
NONE
Energy Bar only
Press
0x10 (SCENE 0)
Long release (>8s)
Decommissioning
Release
0x14 (SCENE 4)
Press
0x12 (SCENE 2)
Long release (>8s)
Commissioning
Release
0x16 (SCENE 6)
Press
0x11 (SCENE 1)
Release
0x15 (SCENE 5)
Press
0x13 (SCENE 3)
Release
0x17 (SCENE 7)
Press
0x21 (ON)
Release
Press
0x20 (OFF)
Release
A0
A1
B0
B1
A0 and B0
A1 and B1
2.3.2.1
Security Parameters
In normal mode, PTM 215ZGP transmits data in secured format in accordance with the
ZigBee Green Power Specification Revision 23, Version 1.0 using the following security parameters:
zgpSecurityLevel is 0b10
Full 4Byte frame counter and full 4Byte MIC
zgpSecurityKeyType is 0b100
Out of the box ZGPD Key
Each PTM 215ZGP device contains its own unique and random security key. This key will be
transmitted to the host system in the Commissioning request which is described in the following chapter.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 14/18
USER MANUAL V1.0
PTM 215ZGP
2.3.3 Commissioning Mode
In order to join an existing ZigBee Green Power compliant network, PTM 215ZGP devices
need to be configured for the correct radio channel and subsequently issue a properly formatted Commissioning Request outlining its device and security parameters. The combination of these tasks is referred to as “Commissioning”.
2.3.3.1
Radio Channel Selection
PTM 215 ZGP devices support sixteen radio channels in the 2.4GHz according to the IEEE
802.15.4 standard. These radio channels are referred to as channels 11 … 26, with the default radio channel of PTM 215ZGP being channel 15.
The radio channel can be changed and a Join request can be sent using a dedicated mode,
the so-called “Commissioning Mode”.
Entry into Commissioning Mode is triggered by pressing and holding button A1 for more
than 8 seconds before releasing it. Upon detecting such event, PTM 215ZGP will enter
Commissioning Mode and send a Commissioning request on the current radio channel.
The radio channel can be incremented by the user by pressing button A1 until the right radio channel has been reached. If the current radio channel is channel 26, then pressing
button A1 will update the radio channel to channel 11.
PTM 215ZGP will send a Commissioning request every time the radio channel is incremented.
The Commissioning mode can be exit by the user once the correct radio channel has been
reached and the Commissioning request was accepted. Exit from Commissioning mode is
triggered by pressing button A0.
2.3.3.2 Commissioning Request
Whenever a radio channel is selected in accordance to 2.3.3.1, PTM 215ZGP will issue a
Commissioning request. This Commissioning request will be sent as broadcast (destination
ID 0xFFFF) on the selected channel.
The Commissioning request will identify the PTM 215ZGP device as ZigBee on / off switch
(device ID 0x02) and contain the unique ZGPD SrcId as well as the unique device security
key encoded with the ZigBee Trust Center Link Key.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 15/18
USER MANUAL V1.0
PTM 215ZGP
2.4
Construction of application specific Switch Rockers
For CAD system development support, 3D construction data is available from EnOcean (IGS
data). Using this data, the mechanical interface is fixed, and the shape and surface of the
rocker(s) can be changed according to requirements.
Polycarbonate is recommended as rocker material since it is both buckling resistant and
wear-proof. It is also recommended to apply Teflon varnish in the areas of actuation.
It is recommended using non-conductive material for the rockers to ensure best
transmission range. Avoid if possible metallic materials or plastics with conducting
ingredients such as graphite.
2.5
Device Mounting
For mounting the PTM 215ZGP device into an application specific case, the package outline
drawings of the device are given in chapter 1.4.
More detailed 3D construction data is available from EnOcean in IGS format.
It is recommended not to mount the device directly onto metal surfaces or into
metal frames since this can lead to significant loss of transmission range.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 16/18
USER MANUAL V1.0
PTM 215ZGP
2.6
Regulatory Notes
PTM 215ZGP has been certified according to applicable regulations.
Changes or modifications not expressly approved by EnOcean could void the user's authority to operate the equipment.
2.6.1 FCC (United States) Regulatory Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
2.6.2 IC (Industry Canada) Regulatory Statement
This device complies with Industry Canada licence-exempt RSS standard(s).
Operation is subject to the following two conditions:
(1) this device may not cause interference, and
(2) this device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils
radio exempts de licence.
L'exploitation est autorisée aux deux conditions suivantes :
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.”
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 17/18
USER MANUAL V1.0
PTM 215ZGP
Transmission Range
The main factors that influence the system transmission range are:
- Type and location of the antennas of receiver and transmitter
- Type of terrain and degree of obstruction of the link path
- Sources of interference affecting the receiver
- “Dead spots” caused by signal reflections from nearby conductive objects.
Since the expected transmission range strongly depends on this system conditions, range
tests should always be performed to determine the reliably achievable range under the
given conditions.
The following figures should be treated as a rough guide only:
Line-of-sight connections
Typically 20 m range in corridors, up to 75 m in halls
Plasterboard walls / dry wood
Typically 20 m range, through max. 3 walls
Ferro concrete walls / ceilings
Typically 7 m range, through max. 1 ceiling
Fire-safety walls, elevator shafts, staircases and similar areas should be considered
as shielded
The angle at which the transmitted signal hits the wall is very important. The effective wall
thickness – and with it the signal attenuation – varies according to this angle. Signals
should be transmitted as directly as possible through the wall. Wall niches should be
avoided.
Other factors restricting transmission range include:
- Switch mounting on metal surfaces (up to 30% loss of transmission range)
- Hollow lightweight walls filled with insulating wool on metal foil
- False ceilings with panels of metal or carbon fibre
- Lead glass or glass with metal coating, steel furniture
The distance between the receiver and other transmitting devices such as computers, audio
and video equipment that also emit high-frequency signals should be at least 0.5 m.
EnOcean GmbH
Kolpingring 18a
82041 Oberhaching
Germany
Phone +49.89.67 34 689-0
Fax
+49.89.67 34 689-50
info@enocean.com
www.enocean.com
Subject to modifications
PTM 215ZGP User Manual | v1.0 | June 2014
Page 18/18

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 18
Language                        : de-DE
Tagged PDF                      : Yes
Author                          : Product Marketing
Creator                         : Microsoft® Office Word 2007
Create Date                     : 2014:06:10 16:55:33+02:00
Modify Date                     : 2014:06:10 16:55:33+02:00
Producer                        : Microsoft® Office Word 2007
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SZV-PTM215Z

Navigation menu