Endress and Hauser SE KG FMR2XKF Level-probing Radar User Manual Micropilot FMR20
Endress and Hauser GmbH and Co Level-probing Radar Micropilot FMR20
Contents
- 1. User Manual FRM10
- 2. User Manual FRM20
User Manual FRM20
Products Solutions Services Technical Information Micropilot FMR20 Free space radar Level measurement for liquids Application • • • • • • Ingress protection: IP66/68 / NEMA 4X/6P Measuring range: up to 20 m (66 ft) Process temperature: –40 to 80 °C (–40 to 176 °F) Process pressure: –1 to 3 bar (–14 to 43 psi) Accuracy: up to ± 2 mm (0.08 in) International explosion protection certificates Your benefits • Level measurement for liquids in storage tanks, open basins, pump shafts and canal systems • Radar measuring device with Bluetooth® wireless technology and HART communication • Simple, safe and secure wireless remote access – ideal for installation in hazardous areas or places difficult to reach • Commissioning, operation and maintenance via free iOS / Android app SmartBlue – saves time and reduces costs • Full PVDF body – for a long sensor lifetime • Hermetically sealed wiring and fully potted electronics – eliminates water ingress and allows operation under harsh environmental conditions • Most compact radar due to unique radar chip design – fits in limited space installations • Best price-performance-ratio radar Micropilot FMR20 Table of contents Important document information . . . . . . . . . . . . . . . 3 Symbols for certain types of information . . . . . . . . . . . . . . Safety symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Symbols in graphics . . . . . . . . . . . . . . . . . . . . . . . . . . . . Terms and abbreviations . . . . . . . . . . . . . . . . . . . . . Registered trademarks . . . . . . . . . . . . . . . . . . . . . . . 5 Product life cycle . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Engineering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Procurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Retirement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Measuring principle . . . . . . . . . . . . . . . . . . . . . . . . . 7 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Input . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Measured variable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Measuring range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operating frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmission power . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Output signal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Signal on alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Linearization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Protocol-specific data . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical connection . . . . . . . . . . . . . . . . . . . . . . . Cable assignment . . . . . . . . . . . . . . . . . . . . . . . . . . . . Supply voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . Current consumption . . . . . . . . . . . . . . . . . . . . . . . . . . Starting time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power supply failure . . . . . . . . . . . . . . . . . . . . . . . . . . Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overvoltage protection . . . . . . . . . . . . . . . . . . . . . . . . . 10 10 10 10 10 10 11 11 13 13 Performance characteristics . . . . . . . . . . . . . . . . . . 14 Reference operating conditions . . . . . . . . . . . . . . . . . . . Maximum measured error . . . . . . . . . . . . . . . . . . . . . . . Measured value resolution . . . . . . . . . . . . . . . . . . . . . . Response time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Influence of ambient temperature . . . . . . . . . . . . . . . . . 14 14 14 15 15 Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Ambient temperature range . . . . . . . . . . . . . . . . . . . . . Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . Climate class . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation height as per IEC 61010-1 Ed.3 . . . . . . . . . . . Degree of protection . . . . . . . . . . . . . . . . . . . . . . . . . . Vibration resistance . . . . . . . . . . . . . . . . . . . . . . . . . . . Electromagnetic compatibility (EMC) . . . . . . . . . . . . . . . 23 23 23 23 23 23 23 Process . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Process temperature, process pressure . . . . . . . . . . . . . . . 24 Dielectric constant . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Mechanical construction . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 25 31 32 32 Operability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Operating concept . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Via Bluetooth® wireless technology . . . . . . . . . . . . . . . . 33 Via HART protocol . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Certificates and approvals . . . . . . . . . . . . . . . . . . . CE mark . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RoHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . EAC conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RCM-Tick marking . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ex approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Explosion-protected smartphones and tablets . . . . . . . . . . Pressure equipment with allowable pressure ≤ 200 bar (2 900 psi) . . . . . . . . . . . . . . . . . . . . . . . . . . EN 302729-1/2 radio standard . . . . . . . . . . . . . . . . . . . FCC / Industry Canada . . . . . . . . . . . . . . . . . . . . . . . . . Other standards and guidelines . . . . . . . . . . . . . . . . . . . 34 34 34 34 34 34 34 34 35 36 37 Ordering information . . . . . . . . . . . . . . . . . . . . . . . 37 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Device-specific accessories . . . . . . . . . . . . . . . . . . . . . . Communication-specific accessories . . . . . . . . . . . . . . . . Service-specific accessories . . . . . . . . . . . . . . . . . . . . . . System components . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 50 51 51 Supplementary documentation . . . . . . . . . . . . . . . 52 Standard documentation . . . . . . . . . . . . . . . . . . . . . . . . 52 Supplementary documentation . . . . . . . . . . . . . . . . . . . 52 Safety Instructions (XA) . . . . . . . . . . . . . . . . . . . . . . . . 52 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Installation conditions . . . . . . . . . . . . . . . . . . . . . . . . . 16 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Important document information Symbols for certain types of information Symbol Meaning Permitted Procedures, processes or actions that are permitted. Preferred Procedures, processes or actions that are preferred. Forbidden Procedures, processes or actions that are forbidden. Tip Indicates additional information. Reference to documentation Reference to page Reference to graphic Visual inspection Safety symbols Symbol Meaning DANGER DANGER! This symbol alerts you to a dangerous situation. Failure to avoid this situation will result in serious or fatal injury. WARNING! WARNING This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in serious or fatal injury. CAUTION NOTE! This symbol contains information on procedures and other facts which do not result in personal injury. NOTICE Electrical symbols Symbols in graphics Symbol Meaning Symbol Meaning Direct current Alternating current Direct current and alternating current Ground connection A grounded terminal which, as far as the operator is concerned, is grounded via a grounding system. Protective ground connection A terminal which must be connected to ground prior to establishing any other connections. Equipotential connection A connection that has to be connected to the plant grounding system: This may be a potential equalization line or a star grounding system depending on national or company codes of practice. Symbol Meaning 1, 2, 3 ... Item numbers 1. , 2. , 3. … Series of steps A, B, C, ... Views A-A, B-B, C-C, ... Endress+Hauser CAUTION! This symbol alerts you to a dangerous situation. Failure to avoid this situation can result in minor or medium injury. Sections V. 5, Rev. 3, 20-12-2016 Micropilot FMR20 Symbol Meaning Hazardous area Indicates a hazardous area. Safe area (non-hazardous area) Indicates the non-hazardous area. V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Terms and abbreviations Term/abbreviation Explanation BA Document type "Operating Instructions" KA Document type "Brief Operating Instructions" TI Document type "Technical Information" SD Document type "Special Documentation" XA Document type "Safety Instructions" PN Nominal pressure MWP Maximum Working Pressure The MWP can also be found on the nameplate. ToF Time of Flight FieldCare Scalable software tool for device configuration and integrated plant asset management solutions DeviceCare Universal configuration software for Endress+Hauser HART, PROFIBUS, FOUNDATION Fieldbus and Ethernet field devices DTM Device Type Manager DD Device Description for HART communication protocol DC Relative dielectric constant εr Operating tool The term "operating tool" is used in place of the following operating software: • SmartBlue (app), for operation using an Android or iOS smartphone or tablet. • FieldCare / DeviceCare, for operation via HART communication and PC BD Blocking Distance; no signals are analyzed within the BD. Registered trademarks HART® Registered trademark of the HART Communication Foundation, Austin, USA Bluetooth® The Bluetooth® word mark and logos are registered trademarks owned by the Bluetooth SIG, Inc. and any use of such marks by Endress+Hauser is under license. Other trademarks and trade names are those of their respective owners. Apple® Apple, the Apple logo, iPhone, and iPod touch are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc. Android® Android, Google Play and the Google Play logo are trademarks of Google Inc. Endress+Hauser V. 5, Rev. 3, 20-12-2016 Micropilot FMR20 Product life cycle Engineering • • • • • • • • Proven radar measuring technology Level- and open channel flow measurement for Ex and non-Ex Indication of over-flooding situation Wide range of installation possibilities and accessories Highest degree of ingress protection 2D / 3D drawings Spec Sheet Producer Applicator Selection tool for the selection of the perfect measurement solution Device not compatible with transmitters and sensors of ultrasonic measurement technology (e.g. Prosonic FMU9x, FDU9x) Procurement • Best price-performance-ratio radar • Global availability • Order code includes variety of mounting accessories and remote HART indicator RIA15 Installation • Rear- and front side thread for flexible installation • Slip- on flange for nozzle installation • Complete measuring point: Including mounting accessory, RIA15 and flooding protection tube Commissioning • Easy and fast setup via SmartBlue (app) and DeviceCare / FieldCare or RIA15 • No additional tools or adapters required • Local languages (up to 15) Operation • • • • Maintenance • No maintenance required • Technical experts on-call around the global Retirement • Environmentally responsible recycling concepts • RoHS compliance (Restriction of certain hazardous substances), lead-free soldering of electronic components Continuous self-monitoring Diagnosis information acc. NAMUR NE107 with clear text messages remedy directives Signal curve via SmartBlue (app) and DeviceCare / FieldCare Encrypted single point-to-point data transmission (Fraunhofer-Institut, third party, tested) and password-protected communication via Bluetooth® wireless technology V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Measuring principle The Micropilot is a "downward-looking" measuring system, operating based on the time-of-flight method (ToF). It measures the distance from the reference point R to the product surface. Radar impulses are emitted by an antenna, reflected off the product surface and received again by the radar system. 100% 0% A0028409 1 Input Setup parameters of the Micropilot Empty calibration (= zero) Full calibration (= span) Measured distance Level (L = E - D) Flow rate at measuring weirs or channels (calculated from the level using linearization) Reference point The reflected radar impulses are received by the antenna and transmitted into the electronics. A microprocessor evaluates the signal and identifies the level echo caused by the reflection of the radar impulse at the product surface. This clear signal detection system benefits from over 30 years' experience with time-of-flight procedures. The distance D to the product surface is proportional to the time of flight t of the impulse: D = c · t/2, where c is the speed of light. Based on the known empty distance E, the level L is calculated: L=E–D Output The Micropilot is adjusted by entering the empty distance E (= zero point) and the full distance F (= span). • Current output: 4 to 20 mA • Digital output (HART, SmartBlue): 0 to 10 m (0 to 33 ft) or 0 to 20 m (0 to 66 ft) depending on antenna version Endress+Hauser V. 5, Rev. 3, 20-12-2016 Micropilot FMR20 Input Measured variable The measured variable is the distance between the reference point and the product surface. The level is calculated based on E, the empty distance entered. Measuring range Maximum measuring range Device Maximum measuring range FMR20 with 40 mm (1.5 in) antenna 10 m (33 ft) FMR20 with80 mm (3 in) antenna 20 m (66 ft) Requirements of the installation • • • • • • recommended tank height > 1.5 m (5 ft) or media with low DC value Open channel minimum width 0.5 m (1.6 ft) Calm surfaces No agitators No buildup Relative dielectric constant εr > 4 Usable measuring range The usable measuring range depends on the antenna size, the medium's reflective properties, the installation position and any possible interference reflections. The following table describes the media groups. Media groups εr Example 4 to 10 E.g. concentrated acid, organic solvents, ester, aniline, alcohol, acetone. > 10 Conductive liquids, aqueous solutions, diluted acids and bases Reduction of the max. possible measuring range by: • Media with bad reflective properties (= low εr value) • Formation of buildup, particularly of moist products • Strong condensation • Foam generation • Freezing of sensor Operating frequency Transmission power K-band (~ 26 GHz) Distance Mean power density in the direction of the beam 1 m (3.3 ft) < 12 nW/cm2 5 m (16 ft) < 0.4 nW/cm2 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Output Output signal 4 to 20 mA An 4 to 20 mA interface is used for measured value output and to power to the device. Digital output HART® • Signal encoding; FSK ±0.5 mA over current signal • Data transmission rate;1 200 Bit/s Bluetooth® wireless technology (available as an optional extra) The device has a Bluetooth® wireless technology interface and can be operated and configured via this interface using the SmartBlue app. • The range under reference conditions is 25 m (82 ft) • Incorrect operation by unauthorized persons is prevented by means of encrypted communication and password encryption. • The Bluetooth® wireless technology interface can be deactivated. Signal on alarm Depending on the interface, failure information is displayed as follows: • Current output Alarm current: 22.5 mA (as per NAMUR RecommendationNE 43) • Operating tool via digital communication (HART) or SmartBlue (app) – Status signal (as per NAMUR Recommendation NE 107) – Plain text display with remedial action Linearization The linearization function of the device allows the conversion of the measured value into any unit of length, weight, flow or volume. When operating using DeviceCare and FieldCare, linearization tables for volume calculation in vessels are preprogrammed (see following list). Pre-programmed linearization curves • Cylindrical tank • Spherical tank • Tank with pyramid bottom • Tank with conical bottom • Tank with flat bottom Other linearization tables of up to 32 value pairs can be entered manually. Protocol-specific data HART Manufacturer ID 17 (0x11) Device type ID 44 (0x112c) HART specification 7.0 Device description files (DTM, DD) Information and files under: • www.endress.com • www.hartcomm.org HART load Min. 250 Ω HART device variables Assignment of HART device variables is fixed and cannot be changed. Measured values for PV (primary variable) Level linearized Advanced diag. measured values for SV (secondary variable) Distance Advanced diag. measured values for TV (tertiary variable) Relative echo amplitude Advanced diag. measured values for QV (quarternary variable) Temperature Endress+Hauser Supported functions Additional transmitter status Multidrop current 4 mA Time for connection setup <1s V. 5, Rev. 3, 20-12-2016 Micropilot FMR20 Electrical connection Cable assignment A0028954 2 Supply voltage Cable assignment Plus, brown wire Minus, blue wire An external power supply is necessary. Terminal voltage U at device 10.5 to 30 VDC 2-wire Maximum load R, depending on supply voltage U0 of power supply unit R [W] 500 10 10.5 20 21.75 30 U0 [V] A0029226 Potential equalization No special measures for potential equalization are required. In the case of a device for the hazardous area, please comply with the safety instructions in the separate "Safety Instructions" (XA, ZD) document. Various power supply units can be ordered from Endress+Hauser: see "Accessories" section → 51 Battery operation The sensor's Bluetooth® wireless technology communication can be disabled to increase the operating life of the battery. Power consumption Maximum input power: 675 mW Current consumption • maximum input current: <25 mA • Maximum start-up current: 3.6 mA Starting time First stable measured value after 20 s (with supply voltage = 24 VDC) 10 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Power supply failure The configuration remains stored in the sensor. Connection FMR20, 4 to 20 mA HART Circuit diagram / Description FMR20 connection with HART communication, voltage source and 4 to 20 mA display mA A0028908 3 FMR20 block diagram, HART Micropilot FMR20 HART resistance Power supply The HART communication resistor of 250 Ω in the signal line is always necessary in the case of a low-impedance power supply. The voltage drop to be taken into account is: Max. 6 V with 250 Ω communication resistor Endress+Hauser V. 5, Rev. 3, 20-12-2016 11 Micropilot FMR20 FMR20 with RIA15 (incl. option for basic configuration FMR20) The RIA15 remote display can be ordered together with the device. Product structure, feature 620 "Accessory enclosed": • Option R4 "Remote display RIA15 non-hazardous area, field housing" • Option R5 "Remote display RIA15 with explosion protection approval, field housing" Alternatively available as an accessory, for details see Technical Information TI01043K and Operating Instructions BA01170K The RIA15 process display unit is loop-powered and does not require any external power supply. The voltage drop to be taken into account is: • ≤1 V in the standard version with 4 to 20 mA communication • ≤1.9 V with HART communication • additional 2.9 V if display light is used Circuit diagram / Description LED FMR20 connection, HART communication and RIA15 without backlight Rs DC A0019567 4 Micropilot FMR20 Power supply HART resistance LED FMR20 connection, HART communication and RIA15 with backlight FMR20 block diagram, HART with RIA15 process display unit without light Rs DC A0019568 5 12 V. 5, Rev. 3, 20-12-2016 FMR20 block diagram, HART with RIA15 process display unit with light Micropilot FMR20 Power supply HART resistance Endress+Hauser Micropilot FMR20 FMR20, RIA15 with installed HART communication resistor module The HART communication module for installation in the RIA15 can be ordered together with the device. Product structure, feature 620 "Accessory enclosed": Option R6 "HART communication resistor hazardous / non-hazardous area" The voltage drop to be taken into account is: Max. 7 V Alternatively available as an accessory, for details see Technical Information TI01043K and Operating Instructions BA01170K Circuit diagram / Description LED FMR20 connection and RIA15 without backlight Rs DC A0020839 6 FMR20 block diagram, RIA15 without light, HART communication resistor module HART communication resistor module Micropilot FMR20 Power supply LED FMR20 connection and RIA15 with backlight Rs DC A0020840 7 Cable specification FMR20 block diagram, RIA15 with light, HART communication resistor module HART communication resistor module Micropilot FMR20 Power supply Unshielded cable, 2 × 0.75 mm2 As per IEC/EN 60079-11 section 10.9, the cable is designed for a tensile strength of 30 N (6.74 lbf) (over a period of 1 h). The FMR20 is supplied with 5 m (16 ft) cable length as standard. Optional lengths are available with 10 m (33 ft) and 20 m (66 ft). Lengths can be selected by the user up to an overall length of 300 m (980 ft) and are available by the meter (ordering option "8") or foot (ordering option "A"). Overvoltage protection Endress+Hauser The device is equipped with integrated overvoltage protection. V. 5, Rev. 3, 20-12-2016 13 Micropilot FMR20 Performance characteristics Reference operating conditions • • • • • Temperature = +24 °C (+75 °F) ±5 °C (±9 °F) Pressure = 960 mbar abs. (14 psia) ±100 mbar (±1.45 psi) Humidity = 60 % ±15 % Reflector: metal plate with diameter ≥ 1 m (40 in) No major interference reflections inside the signal beam Maximum measured error Typical data under reference operating conditions: DIN EN 61298-2, percentage values in relation to the span. Device Value Output digital 1) analog 2) FMR20 40 mm (1.5 in)Antenna Sum of non-linearity, non-repeatability and hysteresis ±2 mm (0.08 in) ±0.02 % Offset/Zero ±4 mm (0.16 in) ±0.03 % FMR20 80 mm (3 in)Antenna Sum of non-linearity, non-repeatability and hysteresis ±2 mm (0.08 in) ±0.02 % Offset/Zero ±4 mm (0.16 in) ±0.03 % 1) 2) HART, SmartBlue (app) Only relevant for 4-20mA current output; add error of the analog value to the digital value Differing values in near-range applications D [mm (in)] 20 (0.79) 10 (0.39) 2 (0.08) -2 (-0.08) -10 (-0.39) -20 (0.79) 0,1 (0.33) 0,5 (1.67) D[m (ft)] A0029049-EN 8 ∆ Measured value resolution 14 Maximum measured error in near-range applications; values for standard version Maximum measured error Reference point of the distance measurement Distance from reference point of antenna Dead band as per EN61298-2: • Digital: 1 mm (0.04 in) • Analog: 4 µA V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Response time Influence of ambient temperature 1) The response time can be configured. The following step response times (as per DIN EN 61298-2) 1) apply if the damping is switched off: Tank height Sampling rate Response time < 20 m (66 ft) 1 s-1 <3s The measurements are carried out in accordance with EN 61298-3. • Digital (HART, Bluetooth® wireless technology): Standard version: average TK = ± 3 mm (0.12 in)/10 K • Analog (current output): – Zero point (4 mA): average TK = 0.02 %/10 K – Span (20 mA): average TK = 0.05 %/10 K According to DIN EN 61298-2 the step response time is the time which passes after a sudden change of the input signal until the output signal assumes 90% of the steady-state value for the first time. Endress+Hauser V. 5, Rev. 3, 20-12-2016 15 Micropilot FMR20 Installation Installation conditions Installation types A0030605 9 Wall, ceiling or nozzle installation Wall or ceiling mount, adjustable Mounted at front thread Mounted at rear thread Ceiling installation with counter nut (included in delivery) Caution! • The sensor cables are not designed as supporting cables. Do not use as a suspension wire. • In the free-field, a vertically downward orientation must be ensured at all times Nozzle installation The antenna should be just out of the nozzle for optimum measurement. The interior of the nozzle must be smooth and may not contain any edges or welded joints. The edge of the nozzle should be rounded if possible. The maximum nozzle length L depends on the nozzle diameter D. Please note the specified limits for the diameter and length of the nozzle. A0028413 10 FMR20 nozzle installation FMR20 80 mm (3 in) antenna FMR20 40 mm (1.5 in) antenna 80 mm (3 in) antenna, inside nozzle 16 80 mm (3 in) antenna, outside nozzle 40 mm (1.5 in) 40 mm (1.5 in) antenna, antenna, outside nozzle inside nozzle D min. 120 mm (4.72 in) min. 80 mm (3 in) min. 40 mm (1.5 in) min. 80 mm (3 in) L max. 205 mm (8.07 in) + D × 4,5 max. D × 4,5 max. D × 1,5 max. 140 mm (5.5 in) + D × 1,5 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Orientation BD A0028410 11 Tank installation position • If possible install the sensor so that its lower edge projects into the vessel. • Recommended distance A wall - nozzle outer edge: ~ 1/6 of the tank diameter D. However, the device must not under any circumstances be mounted closer than 15 cm (5.91 in) to the tank wall. • Do not mount the sensor in the center of the tank. • Avoid measurements through the filling curtain. • Avoid equipment such as limit switches, temperature sensors, baffles, heating coils etc. • Several devices can be operated in a single tank without impacting on each other. • No signals are analyzed within the Blocking distance (BD). It can therefore be used to suppress interference signals (e.g. the effects of condensate) close to the antenna. An automatic Blocking distance of at least 0.1 m (0.33 ft) is configured as factory setting. However, this can be overwritten manually (0 m (0 ft) is also permitted). Automatic calculation: Blocking distance = Empty calibration - Full calibration - 0.2 m (0.656 ft). Each time a new entry is made in the Empty calibration parameter orFull calibration parameter, the Blocking distance parameter is recalculated automatically using this formula. If the result of the calculation is a value <0.1 m (0.33 ft), the Blocking distance of0.1 m (0.33 ft) continues to be used. Endress+Hauser V. 5, Rev. 3, 20-12-2016 17 Micropilot FMR20 Alignment 90 90 ° ° • Align the antenna vertically to the product surface. • Align the eyelet with the mounting eye as well as possible towards the tank wall. ° 90 90 ° 90 ° A0028927 12 18 Sensor alignment when mounting in tank V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Beam angle α W = 2 x D x tan _ α A0029053-EN 13 Relationship between beam angle α, distance D and beam diameter W The beam angle is defined as the angle α, at which the power density of the radar waves reaches half the value of the maximum power density (3dB width). Microwaves are also emitted outside the signal beam and can be reflected off interfering installations. Beam diameter W as a function of beam angle α and distance D. FMR20 Antenna size 40 mm (1.5 in) 40 mm (1.5 in) with accessory "flooding protection tube" Beam angle α 30° 12° Distance (D) Endress+Hauser 80 mm (3 in) 80 mm (3 in) with accessory "flooding protection tube" 12° Beam diameter W 3 m (9.8 ft) 1.61 m (5.28 ft) 0.63 m (2.07 ft) 0.63 m (2.1 ft) 5 m (16.4 ft) 2.68 m (8.79 ft) 1.51 m (4.95 ft) 1.05 m (3.45 ft) 10 m (33 ft) 5.36 m (17.59 ft) 2.10 m (6.90 ft) 2.1 m (6.9 ft) 15 m (49 ft) 3.15 m (10.34 ft) 20 m (66 ft) 4.2 m (13.79 ft) V. 5, Rev. 3, 20-12-2016 19 Micropilot FMR20 Measurement in plastic vessels If the outer wall of the vessel is made of a non-conductive material (e.g. GFR) microwaves can also be reflected off interfering installations outside of the vessel (e.g. metallic pipes (1), ladders (2), grates (3), ...). Therefore there should be no such interfering installations in the signal beam. For more information, please contact Endress+Hauser. A0029540 14 Measurement in a plastic vessel Weather protection cover For outdoor use, a weather protection cover is recommended. A0031277 15 Weather protection cover, e.g. with 40 mm (1.5") antenna The sensor is not completely covered in the case of the 40 mm (1.5 in) antenna or the 80 mm (3 in) antenna. The weather protection cover is available as an accessory. → 38 20 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Free-field measurement with flooding protection tube The flooding protection tube guarantees a definitive analysis of the maximum level even in the event that the sensor is completely flooded. In free-field installations and / or in applications where there is a risk of flooding, the flooding protection tube must be used. A0031093 16 Function of flooding protection tube Air pocket O-ring (EPDM) seal Blocking distance Max. Level Flooding protection tube 40 mm (1.5 in) Antenna, metallized PBT-PC: For use with devices in product structure, feature 100 "Process connection front", option WFE "Thread ISO228 G1-1/2". The flooding protection tube can be ordered with the device. Product structure, feature 620 "Accessory enclosed", option R7 "Flooding protection tube, metallized PBT-PC suitable for 40 mm (1.5 in) antenna with G1-1/2" process connection on front". Alternatively available as an accessory; order number 71325090. Flooding protection tube 80 mm (3 in) Antenna, metallized PBT-PC: For use with devices in product structure, feature 100 "Process connection on front", option XR0 "Customer mounting device without flange". The flooding protection tube can be ordered with the device. Product structure, feature 620 "Accessory enclosed", option R8 "Flooding protection tube, metallized PBT-PC suitable for 80 mm (3 in) antenna. Alternatively available as an accessory; order number 71327051. Endress+Hauser V. 5, Rev. 3, 20-12-2016 21 Micropilot FMR20 Installation with mounting bracket, adjustable A0030606 17 Installation with mounting bracket, adjustable • Wall or ceiling installation is possible. • Using the mounting bracket, position the antenna so that it is perpendicular to the product surface. NOTICE There is no conductive connection between the mounting bracket and transmitter housing. Risk of electrostatic charge. ‣ Integrate the mounting bracket in the local potential equalization system. The mounting bracket is available as an accessory. → 38 Cantilever installation, with pivot A0028412 18 Cantilever installation, with pivot Installation with cantilever and wall bracket Installation with cantilever and mounting frame The cantilever can be turned (e.g. in order to position the sensor over the center of the channel, for example) The cantilever, wall bracket and mounting frame are available as accessories. → 38 22 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Environment Ambient temperature range Measuring device: –40 to +80 °C (–40 to +176 °F) It may not be possible to use the Bluetooth connection at ambient temperatures > 60 °C (140 °F). Outdoor operation in strong sunlight: • Mount the device in the shade. • Avoid direct sunlight, especially in warmer climatic regions. • Use a weather protection cover → 38. Storage temperature –40 to +80 °C (–40 to +176 °F) Climate class DIN EN 60068-2-38 (test Z/AD) Installation height as per IEC 61010-1 Ed.3 Generally up to 2 000 m (6 600 ft) above sea level. Degree of protection Tested acc. to: – IP66, NEMA 4X – IP68, NEMA 6P (24 h at 1.83 m (6.00 ft) under water) Vibration resistance DIN EN 60068-2-64 / IEC 60068-2-64: 20 to 2 000 Hz, 1 (m/s2)2/Hz Electromagnetic compatibility (EMC) Electromagnetic compatibility in accordance with all of the relevant requirements outlined in the EN 61000 series and NAMUR Recommendation EMC (NE 21). For details, please refer to the Declaration of Conformity 2) 2) Available for download at www.endress.com. Endress+Hauser V. 5, Rev. 3, 20-12-2016 23 Micropilot FMR20 Process Process temperature, process pressure FMR20 [bar (psi)] 3 (43.5) -1(-14.5) Tp -40 0 (+32) +80 (+176) [°C (°F)] A0029007-EN 19 Feature 100 "Process connection" Process temperature range Process pressure range • • • • –40 to +80 °C (–40 to +176 °F) prel = –1 to 3 bar (–14.5 to 43.5 psi) pabs < 4 bar (58 psi) 1) • RPF: UNI slip-on flange 3"/DN80/80; PP –40 to +80 °C • RRF: UNI slip-on flange 4"/DN100/100; PP (–40 to +176 °F) • RSF: UNI slip-on flange 6"/DN150/150; PP prel = –1 to 1 bar (–14.5 to 14.5 psi) pabs < 2 bar (29 psi) 1) 1) Dielectric constant FMR20: Permitted range for process temperature and process pressure VEE: Thread ASME MNPT1-1/2; PVDF VFE: Thread ASME MNPT2; PVDF WFE: Thread ISO228 G1-1/2; PVDF WFE: Thread ISO228 G2; PVDF The pressure range may be further restricted in the event of a CRN approval. For liquids εr ≥ 4 For dielectric constants (DC values) of many media commonly used in various industries refer to: • the Endress+Hauser DC manual (CP01076F) • the Endress+Hauser "DC Values App" (available for Android and iOS) 24 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Mechanical construction Dimensions 40 mm (1.5 in) antenna with G 1-1/2" or MNPT 1-1/2" thread ø75 (2.95) 26 (1.02) 20 (0.79) 28 (1.1) 112 (4.4) 140 (5.5) G 1" NPT 1" G 1 1/2" NPT 1 1/2" A0028805 20 Dimensions process connection G 1-1/2" or MNPT 1-1/2" thread,engineering unit:mm (in) Cable gland FNPT 1/2" conduit connection Applies to the following device versions • Feature 095 "Process connection rear side" – VCE: Thread ASME MNPT1; PVDF; FNPT 1/2" conduit connection – WDE: Thread G1 ISO228; PVDF; cable gland • Feature 100 "Process connection front side" – VEE: Thread ASME MNPT1-1/2; PVDF – WFE: Thread ISO228 G1-1/2; PVDF Endress+Hauser V. 5, Rev. 3, 20-12-2016 25 Micropilot FMR20 40 mm (1.5 in) antenna with G 2" or MNPT 2" thread ø75 (2.95) 26 (1.02) 20 (0.79) 28 (1.1) 112 (4.4) 140 (5.5) G 1" NPT 1" G 2" NPT 2" A0028806 21 Dimensions process connection G 2" or MNPT 2" thread,engineering unit:mm (in) Cable gland FNPT 1/2" conduit connection Applies to the following device versions • Feature 095 "Process connection rear side" – VCE: Thread ASME MNPT1; PVDF; FNPT 1/2" conduit connection – WDE: Thread G1 ISO228; PVDF; cable gland • Feature 100 "Process connection front side" – VFE: Thread ASME MNPT2; PVDF – WGE: Thread ISO228 G2; PVDF 26 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 40 mm (1.5 in) antenna with flooding protection tube 264 (10.4) !75 (2.95) !89 (3.5) A0030266 22 Dimensions 40 mm (1.5 in) antenna with mounted flooding protection tube, engineering unit: mm (in) Applies to the following device versions • Feature 100 "Process connection front side" WFE: Thread ISO228 G1-1/2; PVDF • Feature 620 "Accessory enclosed" Option R7 "Flooding protection tube, metallized PBT-PC suitable for 40 mm (1.5 in) antenna with process connection on front G1-1/2". 80 mm (3 in) antenna ø75 (2.95) 20 (0.79) 26 (1.02) G 1" NPT 1" 9 (0.35) 206 (8.11) 28 (1.1) ø115 (4.53) A0028807 23 Endress+Hauser Dimensions 80 mm (3 in) antenna; engineering unit: mm (in) Cable gland FNPT 1/2" conduit connection V. 5, Rev. 3, 20-12-2016 27 Micropilot FMR20 Applies to the following device versions Feature 095 "Process connection rear side" – VCE: Thread ASME MNPT1; PVDF; FNPT 1/2" conduit connection – WDE: Thread G1 ISO228; PVDF; cable gland 28 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 80 mm (3 in) antenna with flooding protection tube ø75 (2.95) 20 (0.79) 26 (1.02) G 1" NPT 1" 322 (12.68) 28 (1.1) !97,3 (3.83) !138,1 (5.44) A0031095 24 Dimensions 80 mm (3 in) antenna with flooding protection tube; engineering unit: mm (in) Cable gland FNPT 1/2" conduit connection Applies to the following device versions • Feature 095 "Process connection rear side" – VCE: Thread ASME MNPT1; PVDF; FNPT 1/2" conduit connection – WDE: Thread G1 ISO228; PVDF; cable gland • Feature 100 "Process connection front side" XR0: Mounting customer side w/o flange • Feature 620 "Accessory enclosed" Option R8 "Flooding protection tube, metallized PBT-PC suitable for 80 mm (3 in) antenna Endress+Hauser V. 5, Rev. 3, 20-12-2016 29 Micropilot FMR20 178 (7) 80 mm (3 in) antenna with UNI slip-on flange 3"/DN80 ø75 (2.95) ø115.6 (4.55) ø156.2 (6.15) ø200 (7.87) 9 (0.36) 18.5 (0.73) 8x ø21 (0.83) A0028813 25 Dimensions 80 mm (3 in) antenna with slip-on flange 3"/DN80, engineering unit: mm (in) Applies to the following device versions • Feature 095 "Process connection rear side" – VCE: Thread ASME MNPT1; PVDF; FNPT 1/2" conduit connection – WDE: Thread G1 ISO228; PVDF; cable gland • Feature 100 "Process connection front side" RPF: UNI slip-on flange 3"/DN80/80; PP, suitable for 3" 150 lbs/DN80 PN16/10K 80 80 mm (3 in) antenna with slip-on flange 4"/DN100 30.5 (1.2) 20 (0.79) 188 (7.4) 8x 19 (0.75) ø143 (5.63) ø 98 (3.86) ø175 (6.89) ø190.5 (5.7) ø228.6 (9) A0028816 26 Dimensions 80 mm (3 in) antenna with slip-on flange 4"/DN100, engineering unit: mm (in) Applies to the following device versions • Feature 095 "Process connection rear side" – VCE: Thread ASME MNPT1; PVDF; FNPT 1/2" conduit connection – WDE: Thread G1 ISO228; PVDF; cable gland • Feature 100 "Process connection front side" RRF: UNI slip-on flange 4"/DN100/100; PP, suitable for 4" 150 lbs/DN100 PN16/10K 100 30 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 80 mm (3 in) antenna with slip-on flange 6"/DN150 30.5 (1.2) 20 (0.79) 188 (7.4) 8x 23 (0.91) ø163 (6.42) ø98 (3.86) ø240 (9.45) ø241.3 (9.5) ø285 (11.2) A0028818 27 Dimensions 80 mm (3 in) antenna with slip-on flange 6"/DN150, engineering unit: mm (in) Applies to the following device versions • Feature 095 "Process connection rear side" – VCE: Thread ASME MNPT1; PVDF; FNPT 1/2" conduit connection – WDE: Thread G1 ISO228; PVDF; cable gland • Feature 100 "Process connection front side" RSF: UNI slip-on flange 6"/DN150/150; PP, suitable for 6" 150 lbs/DN150 PN16/10K 150 G 1" 8 (0.31) 2 (0.08) 2 (0.08) Counter nut for process connection rear side 41 mm A0028419 28 Dimensions of counter nut for process connection rear side, engineering unit: mm (in) Seal • The counter nut with seal (EPDM) is included in the scope of supply. • Material: PA6.6 Weight Endress+Hauser Micropilot Weight (incl. 5 m (16.4 ft) cable) FMR20, 40 mm (1.5 in) antenna Approx. 2.5 kg (5.5 lb) FMR20, 80 mm (3 in) antenna Approx. 2.8 kg (6.2 lb) V. 5, Rev. 3, 20-12-2016 31 Micropilot FMR20 Materials A0028416 29 Connecting cable FMR20 materials 40 mm (1.5 in) antenna 80 mm (3 in) antenna Item Component part Material Sensor housing PVDF Seal EPDM Process connection rear side PVDF Cable gland PA Conduit connection adapter CuZn, nickel-plated O-ring EPDM Counter nut PA6.6 Design ring PBT PC Process connection front side PVDF Available cable length: 5 to 300 m (16 to 980 ft) Material : PVC 32 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Operability Operating concept • 4 to 20 mA, HART • Menu guidance with brief explanations of the individual parameter functions in the operating tool • Optional: SmartBlue (app) via Bluetooth® wireless technology Via Bluetooth® wireless technology A0028895 30 Possibilities for remote operation via Bluetooth® wireless technology Transmitter power supply unit Smartphone / tablet with SmartBlue (app) Transmitter with Bluetooth® wireless technology Via HART protocol ESC 10 11 A0028894 31 10 11 Endress+Hauser Options for remote operation via HART protocol PLC (programmable logic controller) Transmitter power supply unit, e.g. RN221N (with communication resistor) Connection for Commubox FXA195 and Field Communicator 375, 475 RIA15 loop-powered process display unit Field Communicator 475 Computer with operating tool (e.g. FieldCare, DeviceCare, AMS Device Manager, SIMATIC PDM) Commubox FXA195 (USB) Field Xpert SFX350/SFX370 VIATOR modem with Bluetooth® wireless technology Smartphone / tablet with SmartBlue (app) Transmitter with Bluetooth® wireless technology V. 5, Rev. 3, 20-12-2016 33 Micropilot FMR20 Certificates and approvals CE mark The measuring system meets the legal requirements of the applicable EC guidelines. These are listed in the corresponding EC Declaration of Conformity together with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the CE mark. RoHS The measuring system complies with the substance restrictions of the Restriction on Hazardous Substances Directive 2011/65/EU (RoHS 2). EAC conformity The measuring system meets the legal requirements of the applicable EAC guidelines. These are listed in the corresponding EAC Declaration of Conformity together with the standards applied. Endress+Hauser confirms successful testing of the device by affixing to it the EAC mark. RCM-Tick marking The supplied product or measuring system meets the ACMA (Australian Communications and Media Authority) requirements for network integrity, interoperability, performance characteristics as well as health and safety regulations. Here, especially the regulatory arrangements for electromagnetic compatibility are met. The products are labelled with the RCM- Tick marking on the name plate. A0029561 Ex approval • • • • • • • • • • • • Non-hazardous area ATEX II 1 G Ex ia IIC T4 Ga ATEX II 1/2 G Ex ia IIC T4 Ga/Gb CSA C/US General Purpose CSA C/US IS CI.I Div.1 Gr.A-D, AEx ia / Ex ia T4 EAC Ex ia IIC T4 Ga/Gb Non-hazardous area + EAC mark IEC Ex ia IIC T4 Ga/Gb KC Ex ia IIC T4 Ga/Gb 3) INMETRO Ex ia IIC T4 Ga/Gb 3) NEPSI Ex ia IIC T4 Ga/Gb 3) TIIS Ex ia IIC T4 3) Additional safety instructions must be followed for use in hazardous areas. Please refer to the separate "Safety Instructions" (XA) document included in the delivery. Reference to the applicable XA can be found on the nameplate. Details on the available certificates and associated XAs can be found in the Additional documentation section under Safety instructions (XA): → 52. Explosion-protected smartphones and tablets Only mobile end devices with Ex approval may be used in hazardous areas. Pressure equipment with allowable pressure ≤ 200 bar (2 900 psi) Pressure instruments with a flange and threaded boss that do not have a pressurized housing do not fall within the scope of the Pressure Equipment Directive, irrespective of the maximum allowable pressure. Reasons: According to Article 2, point 5 of EU Directive 2014/68/EU, pressure accessories are defined as "devices with an operational function and having pressure-bearing housings". If a pressure instrument does not have a pressure-bearing housing (no identifiable pressure chamber of its own), there is no pressure accessory present within the meaning of the Directive. 3) 34 Under development at time of going to press V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Note: A partial examination shall be performed for pressure instruments that are part of safety equipment for the protection of a pipe or vessel from exceeding allowable limits (equipment with safety function in accordance with Pressure Equipment Directive 2014/68/EU, Article 2, point 4). EN 302729-1/2 radio standard The Micropilot FMR20 devices comply with the LPR (Level Probing Radar) radio standard EN 302729-1/2. The devices are approved for unrestricted use inside and outside of closed vessels in countries of the EU and EFTA. that have implemented this standard. The following countries are those that have currently implemented the directive: Belgium, Bulgaria, Germany, Denmark, Estonia, France, Greece, UK, Ireland, Iceland, Italy, Liechtenstein, Lithuania, Latvia, Malta, The Netherlands, Norway, Austria, Poland, Portugal, Romania, Sweden, Switzerland, Slovakia, Spain, Czech Republic and Cyprus. Implementation is still underway in all of the countries not listed. Please note the following for operation of the devices outside of closed vessels: 1. The device must be mounted in accordance with the instructions in the "Installation" section. 2. Installation must be carried out by properly trained, expert staff. 3. The device antenna must be installed in a fixed location pointing vertically downwards. 4. The installation site must be located at a distance of 4 km from the astronomy stations listed below or otherwise approval must be provided by the relevant authority. If the device is installed at a distance of 4 to 40 km from one of the listed stations, it must not be installed at a height of more than 15 m (49 ft) above the ground. Astronomy stations Country Name of the station Latitude Longitude Germany Effelsberg 50°31'32" North 06°53'00" East Finland Metsähovi 60°13'04" North 24°23'37" East Tuorla 60°24'56" North 24°26'31" East Plateau de Bure 44°38'01" North 05°54'26" East Floirac 44°50'10" North 00°31'37" West Cambridge 52°09'59" North 00°02'20" East Damhall 53°09'22" North 02°32'03" West Jodrell Bank 53°14'10" North 02°18'26" West Knockin 52°47'24" North 02°59'45" West Pickmere 53°17'18" North 02°26'38" West Medicina 44°31'14" North 11°38'49" East Noto 36°52'34" North 14°59'21" East Sardinia 39°29'50" North 09°14'40" East Poland Fort Skala Krakow 50°03'18" North 19°49'36" East Russia Dmitrov 56°26'00" North 37°27'00" East Kalyazin 57°13'22" North 37°54'01" East Pushchino 54°49'00" North 37°40'00" East Zelenchukskaya 43°49'53" North 41°35'32" East Sweden Onsala 57°23'45" North 11°55'35" East Switzerland Bleien 47°20'26" North 08°06'44" East Spain Yebes 40°31'27" North 03°05'22" West France Great Britain Italy Endress+Hauser V. 5, Rev. 3, 20-12-2016 35 Micropilot FMR20 Country Hungary Name of the station Latitude Longitude Robledo 40°25'38" North 04°14'57" West Penc 47°47'22" North 19°16'53" East As a general rule, the requirements outlined in EN 302729-1/2 must be observed. FCC / Industry Canada This device complies with Part 15 of the FCC Rules [and with Industry Canada licence-exempt RSS standard(s)]. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. [Any] Changes or modifications made to this equipment not expressly approved by Endress+Hauser may void the FCC authorization to operate this equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna • Increase the separation between the equipment and receiver • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected • Consult the dealer or an experienced radio/TV technician for help • The installation of the LPR/TLPR device shall be done by trained installers, in strict compliance with the manufacturer’s instructions. • The use of this device is on a “no-interference, no-protection” basis. That is, the user shall accept operations of high-powered radar in the same frequency band which may interfere with or damage this device. However, devices found to interfere with primary licensing operations will be required to be removed at the user’s expense. • Only for usage without the accessory “flooding protection tube”, i.e. NOT in the free-field: This device shall be installed and operated in a completely enclosed container to prevent RF emissions, which can otherwise interfere with aeronautical navigation. 36 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Other standards and guidelines • IEC/EN 61010-1 Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use • IEC/EN 55011 "EMC Emission, RF Emission for Class B". Industrial, scientific and medical equipment – Electromagnetic disturbance characteristics - Limits and methods of measurement • IEC/EN 61000-4-2 EMC Immunity, ESD (Performance Criteria A). Electromagnetic compatibility (EMC): Testing and measurement techniques - Electrostatic discharge immunity test (ESD) • IEC/EN 61000-4-3 EMC Immunity, RF field susceptibility (Performance Criteria A). Electromagnetic compatibility (EMC): Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test • IEC/EN 61000-4-4 EMC Immunity, bursts (Performance Criteria B). Electromagnetic compatibility (EMC): Testing and measurement techniques - Electrical fast transient/burst immunity test • IEC/EN 61000-4-5 EMC Immunity, surge (Performance Criteria B). Electromagnetic compatibility (EMC): Testing and measurement techniques - Surge immunity test • IEC/EN 61000-4-6 EMC Immunity, conducted HF (Performance Criteria A). Electromagnetic compatibility (EMC): Testing and measurement techniques - Immunity to conducted disturbances induced by radiofrequency fields • IEC/EN 61000-4-8 EMC Immunity, magnetic fields 50 Hz. Electromagnetic compatibility (EMC): Testing and measurement techniques - Power frequency magnetic field immunity test • EN 61000-6-3 EMC Emission, conducted HF. EMC: Radiated interference - Residential, commercial and light industry environment • NAMUR NE 21 Electromagnetic compatibility (EMC) of industrial process and laboratory control equipment • NAMUR NE 43 Standardization of the signal level for the breakdown information of digital transmitters with analog output signal. • NAMUR NE 107 Status classification as per NE107 • NAMUR NE 131 Requirements for field devices for standard applications. • IEEE 802.15.1 Requirements for the Bluetooth® wireless technology interface Ordering information Detailed ordering information is available from the following sources: • In the Product Configurator on the Endress+Hauser website: www.endress.com -> Click "Corporate" -> Select your country -> Click "Products" -> Select the product using the filters and search field -> Open product page -> The "Configure" button to the right of the product image opens the Product Configurator. • From your Endress+Hauser Sales Center: www.addresses.endress.com Product Configurator - the tool for individual product configuration • Up-to-the-minute configuration data • Depending on the device: Direct input of measuring point-specific information such as measuring range or operating language • Automatic verification of exclusion criteria • Automatic creation of the order code and its breakdown in PDF or Excel output format • Ability to order directly in the Endress+Hauser Online Shop Endress+Hauser V. 5, Rev. 3, 20-12-2016 37 Micropilot FMR20 Accessories Weather protection cover 90 (3.54) 90 (3.54) Device-specific accessories Ø 98 (3.86) Ø 98 (3.86) A0028841 32 Dimensions of weather protection cover, engineering unit: mm (in) Werkstoff: PVDF The weather protection cover can be ordered with the device (product structure, feature 620 "Accessory enclosed", option R1 "weather protection cover"). Alternatively it can be ordered separately as an accessory; order number 52025686. The sensor is not completely covered in the case of the 40 mm (1.5 in) antenna or the 80 mm (3 in) antenna. 10 (0.39) Securing nut G 1-1/2" G1 1/2" DIN ISO 228 60 mm A0028849 33 38 Dimensions of securing nut, engineering unit: mm (in) V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Suitable for use with devices with G 1-1/2" and MNPT 1-1/2" process connection. Material: PC Order number: 52014146 G 2" 10 (0.39) Securing nut G 2" 70 mm A0029101 34 Dimensions of securing nut, engineering unit: mm (in) Suitable for use with devices with G 2" and MNPT 2" process connection on front. Material: PC Order number: 52000598 Flooding protection tube 40 mm (1.5 in) antenna, metallized PBT-PC 152 (5,98) G 1-1/2" !89 (3,5) A0028418 For use with devices in product structure, feature 100 "Process connection on front", option WFE "Thread ISO228 G1-1/2". Material: PBT-PC, metallized The flooding protection tube can be ordered with the device. Product structure, feature 620 "Accessory enclosed", option R7 "Flooding protection tube, metallized PBT-PC suitable for 40 mm (1.5 in) antenna with G1-1/2" process connection on front". Alternatively available as an accessory; order number 71325090. Endress+Hauser V. 5, Rev. 3, 20-12-2016 39 Micropilot FMR20 Flooding protection tube 80 mm (3 in) antenna, metallized PBT-PC 136,5 (5.37) !138,1 (5.44) !97,3 (3.83) A0031094 For use with devices in product structure, feature 100 "Process connection on front", option XR0 "Customer mounting device without flange". Material: PBT-PC, metallized The flooding protection tube can be ordered with the device. Product structure, feature 620 "Accessory enclosed", option R8 "Flooding protection tube, metallized PBT-PC suitable for 80 mm (3 in) antenna. Alternatively available as an accessory; order number 71327051. Mounting bracket, adjustable 92.5 (3.64) !9 (0.35) 12 (0.47) 12 (0.47) 9 (0.35) 35 (1.38) 117.5 (4.63) 70 (2.76) 9 (0.35) A0028861 35 Dimensions of mounting bracket, engineering unit: mm (in) Consists of: • Mounting bracket: 316 (1.4404) • Angle bracket: 316L (1.4404) • Screws: A4 • Retaining rings: A4 The mounting bracket can be ordered with the device (product structure, feature 620 "Accessory enclosed", option R3 "Mounting bracket adjustable, 316L"). Alternatively, it is available as an accessory; order number 71325079. 40 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 20 UNI flanges A0031103 36 Dimensions of UNI flange, engineering unit: mm Product structure (mm) Feature 620 "Accessory enclosed" Option: (mm) (mm) (mm) Number of bores Product structure Feature 95 "Process connection on front" Option: RA 120 UNI flange 2"/DN50/50, PP, on front 125 165 19 90° VEE Thread ASME MNPT 1-1/2" FAX50-XIGG RA 120 UNI flange 2"/DN50/50, PP, on front 125 165 19 90° WFE Thread ISO228 G 1-1/2" FAX50-XIGC RA 120 UNI flange 2"/DN50/50, PP, on front 125 165 19 90° VFE Thread ASME MNPT 2" FAX50-XIGH Endress+Hauser V. 5, Rev. 3, 20-12-2016 Accessory Product order code structure Feature 100 "Process connection on rear" Option: 41 Micropilot FMR20 Product structure (mm) Feature 620 "Accessory enclosed" Option: (mm) (mm) (mm) Number of bores Product structure Feature 95 "Process connection on front" Option: RA 120 UNI flange 2"/DN50/50, PP, on front 125 165 19 90° WGE Thread ISO228 G 2" RB 120 *UNI flange 2"/DN50/50, PP, on rear 125 165 19 90° VCE Thread ASME MNPT 1" FAX50-XIGF RB 120 *UNI flange 2"/DN50/50, PP, on rear 125 165 19 90° WDE Thread G 1" ISO228 FAX50-XIGB RD 150 UNI flange 3"/DN80/80, PP, on front 160 200 19 45° VEE Thread ASME MNPT 1-1/2" FAX50-XJGG RD 150 UNI flange 3"/DN80/80, PP, on front 160 200 19 45° WFE Thread ISO228 G 1-1/2" FAX50-XJGC RD 150 UNI flange 3"/DN80/80, PP, on front 160 200 19 45° VFE Thread ASME MNPT 2" FAX50-XJGH RD 150 UNI flange 3"/DN80/80, PP, on front 160 200 19 45° WGE Thread ISO228 G 2" FAX50-XJGD RE 150 UNI flange 3"/DN80/80, PP, on rear 160 200 19 45° VCE Thread ASME MNPT 1" FAX50-XJGF RE 150 UNI flange 3"/DN80/80, PP, on rear 160 200 19 45° WDE Thread G 1" ISO228 FAX50-XJGB RG 175 UNI flange 4"/ DN100/100, PP, on front 190.5 228.6 19 45° VEE Thread ASME MNPT 1-1/2" FAX50XKGG RG 175 UNI flange 4"/ DN100/100, PP, on front 190.5 228.6 19 45° WFE Thread ISO228 G 1-1/2" FAX50XKGC RG 175 UNI flange 4"/ DN100/100, PP, on front 190.5 228.6 19 45° VFE Thread ASME MNPT 2" FAX50XKGH 42 V. 5, Rev. 3, 20-12-2016 Accessory Product order code structure Feature 100 "Process connection on rear" Option: FAX50-XIGD Endress+Hauser Micropilot FMR20 Product structure (mm) Feature 620 "Accessory enclosed" Option: (mm) (mm) (mm) Number of bores Product structure Feature 95 "Process connection on front" Option: Accessory Product order code structure Feature 100 "Process connection on rear" Option: RG 175 UNI flange 4"/ DN100/100, PP, on front 190.5 228.6 19 45° WGE Thread ISO228 G 2" RH 175 UNI flange 4"/ DN100/100, PP, on rear 190.5 228.6 19 45° VCE Thread ASME MNPT 1" FAX50XKGF RH 175 UNI flange 4"/ DN100/100, PP, on rear 190.5 228.6 19 45° WDE Thread G 1" ISO228 FAX50XKGB FAX50XKGD Angle bracket for wall mount 400 (15.7) 250 (9.84) 120 (4.72) 120 (4.72) ø16 (0.6) 3 (0.12) 30 (1.2) A0019346 37 Dimensions of angle bracket, engineering unit: mm (in) Process connection Order No. Material Weight G 1-1/2" 942669-0000 316 Ti (1.4571) 3.4 kg (7.5 lb) G 2" 942669-0001 also suitable for MNPT 1-1/2" and MNPT 2" Endress+Hauser V. 5, Rev. 3, 20-12-2016 43 Micropilot FMR20 Cantilever with pivot Installation type sensor process connection rear side A0028885 38 Installation type sensor process connection rear side Installation with cantilever and wall bracket Installation with cantilever and mounting frame Cantilever Wall bracket Mounting frame 20 (0.8) C 20 (0.8) 35 (1.4) 35 (1.4) 15 (0.6) 6.5 (0.3) 22 (0.9) 35 (1.4) 105 (4.1) 75 (2.9)75 (2.9)100 (3.9) M8 50 25 (1.0) 100 (3.9) (2.0) Cantilever with pivot, sensor process connection on rear A0019592 39 Dimensions of cantilever with pivot for sensor process connection on rear, engineering unit: mm (in) Weight Material Order No. 585 mm (23 in) 250 mm (9.84 in) 2 mm (0.08 in) 200 mm (7.87 in) 2.1 kg (4.63 lb) Steel, hot-dip galvanized 919790-0000 2.0 kg (4.41 lb) 316Ti (1.4571) 919790-0001 4.5 kg (9.92 lb) Steel, hot-dip galvanized 919790-0002 4.3 kg (9.48 lb) 316Ti (1.4571) 919790-0003 1 085 mm (42.7 in) 750 mm (29.5 in) 3 mm (0.12 in) 300 mm (11.8 in) • 35 mm (1.38 in) Openings for all G 1" or MNPT 1" connections on rear. • 22 mm (0.87 in) Opening can be used for an additional sensor. Retaining screws are included in delivery. 44 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Installation type sensor process connection on front A0028886 40 Installation type sensor process connection on front Installation with cantilever and wall bracket Installation with cantilever and mounting frame Cantilever Wall bracket Mounting frame 20 (0.8) 20 (0.8) 35 (1.4) 35 (1.4) 15 (0.6) 6.5 (0.3) 22 (0.9) 50/62 (2.0/2.4) 105 (4.1) 75 (2.9)75 (2.9)100 (3.9) M8 25 (1.0) 50 (2.0) 100 (3.9) Cantilever with pivot, sensor process connection on front A0019349 41 Endress+Hauser Dimensions of cantilever with pivot for sensor process connection on front, engineering unit: mm (in) V. 5, Rev. 3, 20-12-2016 45 Micropilot FMR20 Weight Sensor,process connection front side Material Order No. 585 mm (23 in) 250 mm (9.84 in) 2 mm (0.08 in) 200 mm (7.87 in) 1.9 kg (4.19 lb) 1-1/2" Steel, hot-dip galvanized 52014131 316Ti (1.4571) 52014132 Steel, hot-dip galvanized 52014135 316Ti (1.4571) 52014136 Steel, hot-dip galvanized 52014133 316Ti (1.4571) 52014134 Steel, hot-dip galvanized 52014137 316Ti (1.4571) 52014138 2" 1 085 mm (42.7 in) 750 mm (29.5 in) 3 mm (0.12 in) 300 mm (11.8 in) 4.4 kg (9.7 lb) 1-1/2" 2" • 50 mm (2.17 in) or 62 mm (2.44 in) openings for all connections on front G 1-1/2" (MNPT 1-1/2") or G 2" (MNPT 2"). • 22 mm (0.87 in) Opening can be used for an additional sensor. Retaining screws are included in delivery. Mounting stand for cantilever with pivot 3.2 (0.13) 60 (2.36) 700/1400 (27.6 / 55.1) ø33.7 (1.3) 55 (2.17) 100 76 (3.94) (2.99) 200 (7.87) 4 (0.16) 6.5 (0.3) 45 (1.77) 25 (0.98) 13 (0.5) 100 (3.94) 20 (0.8) 130 (5.12) 100 (3.94) 150 (5.91) A0019279 42 46 Dimensions of mounting frame, engineering unit: mm (in) Height Material Weight Order No. 700 mm (27.6 in) Steel, galvanized 3.2 kg (7.06 lb) 919791-0000 700 mm (27.6 in) 316Ti (1.4571) 1 400 mm (55.1 in) Steel, galvanized 1 400 mm (55.1 in) 316Ti (1.4571) V. 5, Rev. 3, 20-12-2016 919791-0001 4.9 kg (10.08 lb) 919791-0002 919791-0003 Endress+Hauser Micropilot FMR20 Wall bracket for cantilever with pivot 3.2 (0.1) ø33.7 (1.3) 25 (1.0) ~88 (3.5) 150 (5.9) 13 (0.5) 110 (4.3) 6.5 (0.3) ~213 (8.4) 180 (7.1) 5 (0.2) 110 (4.3) 150 (5.9) A0019350 43 Dimensions of wall bracket, engineering unit: mm (in) Material Weight Order No. Steel, galvanized 1.4 kg (3.09 lb) 919792-0000 316Ti (1.4571) 919792-0001 Ceiling mounting bracket 75 1.5 185 105 12 ø5.6 110±2 15 50 95 100 10 10 10 ø35 15 155 A0028891 44 Dimensions of ceiling mounting bracket, engineering unit: mm (in) Material: 316L (1.4404) The mounting bracket can be ordered with the device (product structure, feature 620 "Accessory enclosed", option R2 "Ceiling mounting bracket, 316L"). Alternatively, it is available as an accessory; order number 71093130. Endress+Hauser V. 5, Rev. 3, 20-12-2016 47 Micropilot FMR20 RIA15 in the field housing (incl. option for basic configuration FMR20) 55.5 (2.19) 81.5 (3.21) 106.5 (4.19) 131 (5.16) mm (in) A0017722 45 Dimensions of RIA15 in field housing, engineering unit: mm (in) The RIA15 remote display can be ordered together with the device. Product structure, feature 620 "Accessory enclosed": • Option R4 "Remote display RIA15 non-hazardous area, field housing" • Option R5 "Remote display RIA15 Ex= explosion protection approval, field housing" Alternatively available as an accessory, for details see Technical Information TI01043K and Operating Instructions BA01170K. 24 (0.94) 22 (0.87) 54 (2.13) 8.1 (0.32) HART communication resistor 31 (1.22) A0020858 46 Dimensions of HART communication resistor, engineering unit: mm (in) A communication resistor is required for HART communication. If this is not already present (e.g. in the power supply RMA, RN221N, RNS221, ...), it can be ordered with the device via the product structure, feature 620 "Accessory enclosed": option R6 "HART communication resistor hazardous / non-hazardous area". Alternatively available as an accessory, for details see Technical Information TI01043K and Operating Instructions BA01170K. The HART communication resistor is specially designed for use with the RIA15 and can be attached easily. 48 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 A0020844 Endress+Hauser 1. Disconnect plug-in terminal block. 2. Insert the terminal block into the slot provided on the HART communication resistor module. 3. Insert the HART communication resistor in the slot in the housing. V. 5, Rev. 3, 20-12-2016 49 Micropilot FMR20 Communication-specific accessories Accessories Description Commubox FXA195 HART For intrinsically safe HART communication with FieldCare / DeviceCare via USB interface. For details, see Technical Information TI00404F Accessories Description HART Loop Converter HMX50 Is used to evaluate and convert dynamic HART process variables to analog current signals or limit values. Order number: 71063562 For details, see Technical Information TI00429F and Operating Instructions BA00371F Accessories Description WirelessHART adapter SWA70 Is used for the wireless connection of field devices. The WirelessHART adapter can be easily integrated into field devices and existing infrastructures, offers data protection and transmission safety and can be operated in parallel with other wireless networks. For details, see Operating Instructions BA00061S Accessories Description Fieldgate FXA320 Gateway for remote monitoring of field devices with 4 to 20 mA and digital output signal details, see Technical Information TI00025S and Operating Instructions For BA00053S Accessories Description Fieldgate FXA520 HART Gateway for remote monitoring of field devices with HART / 4 to 20 mA and digital output signal For details, see Technical Information TI00025S and Operating Instructions BA00051S Accessories Description Field Xpert SFX350 Field Xpert SFX350 is a mobile computer for commissioning and maintenance. It enables efficient device configuration and diagnostics for HART and FOUNDATION Fieldbus devices in non-hzardous areas. For details, see Operating Instructions BA01202S Accessories Description Field Xpert SFX370 Field Xpert SFX370 is a mobile computer for commissioning and maintenance. It enables efficient device configuration and diagnostics for HART and FOUNDATION Fieldbus devices in non-hazardous areas and hazardous areas. For details, see Operating Instructions BA01202S 50 V. 5, Rev. 3, 20-12-2016 Endress+Hauser Micropilot FMR20 Service-specific accessories Accessory Description FieldCare / DeviceCare Endress+Hauser's FDT-based Plant Asset Management tool. Helps to configure and maintain all field devices of your plant. By supplying status information it also supports the diagnosis of the devices. For details refer to Operating Instructions BA00027S and BA00059S. System components Accessories Description Memograph M graphic display recorder The Memograph M graphic data manager provides information on all the relevant process variables. Measured values are recorded safely, limit values are monitored and measuring points analyzed. The data are stored in the 256 MB internal memory and also on an SD card or USB stick. details, see Technical Information TI01180R and Operating Instructions For BA01338R RNS221 Supply unit for powering two 2-wire measuring devices. Bidirectional communication is possible via the HART communication jacks. details, see Technical Information TI00081R and Operating Instructions For KA00110R RN221N Active barrier with power supply for safe separation of 4...20 mA current circuits Bi-directional HART-communication is possible using the built-in communication sockets (with resistance R=250 Ω) details, see Technical Information TI073R and Operating Instructions For BA202R RMA42 Digital process transmitter for monitoring and visualizing analog measured values details, see Technical InformationTI00150R and Operating Instructions For BA00287R RIA452 Digital process meter RIA452, in panel mounted housing for monitoring and displaying analog measured values, batch, pump control functions and can be used as a preset counter and for measuring flow details, see Technical Information TI113R nd Operating Instructions For BA00254R HAW562 Surge arrester for DIN rail according to IEC 60715, used to protect electronic components from being destroyed by overvoltage. For details, see Technical Information TI01012K Endress+Hauser V. 5, Rev. 3, 20-12-2016 51 Micropilot FMR20 Supplementary documentation The following document types are available in the Download Area of the Endress+Hauser Internet site: www.endress.com → Download: Standard documentation Supplementary documentation Safety Instructions (XA) Device Document type Document code FMR20 Brief Operating Instructions KA01248F Device Document type Document code FMR20 Operating Instructions BA01578F Device Document type Document code RIA15 Technical Information TI01043K Operating Instructions BA01170K Depending on the approval, the following Safety Instructions (XA) are supplied with the device. They are an integral part of the Operating Instructions. Feature 010 Approval Feature 020: "Power Supply; Output" A 1), P 2) 1) 2) 3) BA ATEX II 1 G Ex ia IIC T4 Ga BB ATEX II 1/2 G Ex ia IIC T4 Ga/Gb IA IEC Ex ia IIC T4 Ga IB IEC Ex ia IIC T4 Ga/Gb CB CSA C/US IS CI.I Div.1 Gr.A-D, AEx ia / Ex ia T4 GA EAC Ex ia IIC T4 Ga GB EAC Ex ia IIC T4 Ga/Gb KA KC Ex ia IIC T4 Ga KB KC Ex ia IIC T4 Ga/Gb MA INMETRO Ex ia IIC T4 Ga MB INMETRO Ex ia IIC T4 Ga/Gb NA NEPSI Ex ia IIC T4 Ga NB NEPSI Ex ia IIC T4 Ga/Gb XA01443F XA01445F XA01578F XA01575F 3) XA01576F 3) XA01577F 3) 2 wire; 4-20 mA HART configuration 2 wire; 4-20 mA HART/Bluetooth® (app) configuration At the time of printing in preparation The nameplate indicates the Safety Instructions (XA) that are relevant to the device. 52 V. 5, Rev. 3, 20-12-2016 Endress+Hauser *unbekannt* www.addresses.endress.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Author : 00 Create Date : 2016:12:20 10:14:32+01:00 Keywords : Technical, Information;, Micropilot, FMR20;, Free, space, radar Modify Date : 2016:12:20 10:29:17+01:00 Subject : Free space radar Has XFA : No Language : EN XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Format : application/pdf Creator : 00 Description : Free space radar Title : Micropilot FMR20 Creator Tool : AH XSL Formatter V5.3 MR5 for Windows (x64) : 5.3.6.0 (2012/12/04 12:44:48) Metadata Date : 2016:12:20 10:29:17+01:00 Producer : Antenna House PDF Output Library 2.6.0 (Windows (x64)) Trapped : False Document ID : uuid:49478f13-da6b-4d1e-a6ed-eef0f9aeb605 Instance ID : uuid:328c48ee-4ae6-456c-923a-05c66331541e Page Mode : UseOutlines Page Count : 56EXIF Metadata provided by EXIF.tools