Enecsys DEREPEATER0001 Double Ended Repeater (DER) User Manual Double Repeater
Enecsys Ltd Double Ended Repeater (DER) Double Repeater
Enecsys >
manual
intelligent reliable power Enecsys Micro-Inverters Double Repeater User Manual Version 1.0 D FT FT FT FT FT Double Repeater User Manual Intelligent Reliable Power FT FT FT FT FT FT FT FT FT CONTENTS FT Technical specification Compliance Printing Attaching the internal antenna Mounting the Enecsys Double Repeater Wall mounting the Enecsys Double Repeater (adhesive pad method) Wall mounting the Enecsys Double Repeater (screw fixed method) Mounting with a cable tie Installing the external antenna Turning the Enecsys Double Repeater on Turning the Enecsys Double Repeater off Installation FT Conventions used in this manual Safety Scope of delivery Enecsys Double Repeater When to install an Enecsys Double Repeater FT Introduction 10 11 12 13 14 15 18 19 © ENECSYS 2010. All rights reserved. D FT FT FT FT FT Intelligent Reliable Power FT FT FT FT FT FT FT FT FT FT FT FT © ENECSYS 2010. All rights reserved. This manual contains information specific to the installation of an Enecsys Double Repeater. Although the installation is simple a basic knowledge of internet routers, wired or wireless may be beneficial although not necessary. Installation of the Enecsys Double Repeater is a 'plug and play'. Enecsys have designed the hardware to be a simple as possible for the installer and enduser alike. Your solar PV (photo-voltaic) installation, when combined with an Enecsys Micro-Inverter with its in-built wireless antenna is able to communicate wirelessly with the Gateway. This allows for comprehensive monitoring of the solar PV array, module-by-module. Monitoring an array module by module enables the user to see energy generation at module level. Monitoring also allows the end-user to see the performance of any module at any time of the day. An Enecsys Double Repeater acts as a bridge between the Micro-inverter and the Gateway in situations where a sufficient communication link cannot be established. For circumstances where it may be necessary to install an Enecsys Double Repeater, See“When to install an Enecsys Double Repeater” on page 5. 1. Introduction Double Repeater User Manual D FT FT FT FT FT Intelligent Reliable Power FT FT FT FT 1.1 Conventions used in this manual Double Repeater User Manual FT FT FT FT FT FT FT FT © ENECSYS 2010. All rights reserved. The following conventions are used throughout this manual, these conventions should be noted and followed at all times. Warning: Warning statements must be heeded at all times. A warning symbol indicates that a process or instrument has the potential to harm or cause lethal injury if the correct method of handling is not employed. Caution: Caution statements are used to indicate where a part of the installation process may require special attention. Caution statements should be followed at all times. Attention: Attention statements are used to indicate where a part of the process or instrument has a special requirement. Attention statements should be followed at all times. D FT FT FT FT FT Intelligent Reliable Power FT FT FT FT 1.2 Safety Double Repeater User Manual FT FT FT Before installing and using the any Enecsys Repeater please ensure that you have fully read and understand all of the installation and user instructions and heed all warnings and cautions given. Install in a clean dry environment, indoors and if possible away from heat sources and out of direct sunlight. FT FT FT FT • All electrical installations should be performed in accordance with all local and national electrical installation codes and practice. FT • There are no user serviceable parts inside this unit. • There are no replaceable or re-chargeable batteries contained within the Repeater. • Do not attempt to open the unit. Tampering with the Repeater may result in electrical shock or death. • Do not install this equipment in adverse weather conditions or in a wet environment. • Do not install this equipment during an electrical storm. © ENECSYS 2010. All rights reserved. D FT FT FT E. 1 x Plug-top 5V DC, 1A adaptor with 2.1mm jack. F. 3 x Double sided adhesive pads. 1 x Coaxial cable reverse polarity with RP SMA connectors, 15 - 30 meter lengths. FT D. FT 1 x External antenna. C. 1 x Fixed antenna. B. FT FT FT FT FT FT FT 1 x Enecsys Double Repeater. FIGURE 1. Scope of delivery. FT FT FT FT FT A. © ENECSYS 2010. All rights reserved. Intelligent Reliable Power The following list details the scope of delivery, please ensure that all parts are present before starting the installation. 1.3 Scope of delivery Double Repeater User Manual D FT FT FT FT FT Intelligent Reliable Power FT FT FT FT 1.4 Enecsys Double Repeater Double Repeater User Manual FT FT FT FT FT FT FT • UV screened windows. © ENECSYS 2010. All rights reserved. • The distance between the micro-inverters and the wireless antenna is too great. • A roof may be made out a metallic material or be a foil insulated. FT Depending upon the house construction and build materials it may be necessary to add an Enecsys Double Repeater in order to provide stable communications between the inverters and the Gateway over a long time period. An Enecsys Double Repeater is used in situations where a Single Repeater is unable to provide the Gateway with a strong sustainable communication link. The Enecsys Double Repeater acts a bridge between the Micro-inverter and the Gateway, improving the communication link and providing an uninterrupted flow of information between the two devices. Certain building materials can prevent a strong signal from being established in the communication link. 1.5 When to install an Enecsys Double Repeater The Enecsys Double Repeater provides a ‘hop’ between nodes in a network. The Enecsys Double Repeater is used to allow communication between the Micro-inverters and Gateway where the propagation losses are too high for a reliable communication link, particularly where metallic structures prevent RF propagation. There are various implementations of Enecsys Double Repeaters, more than one Enecsys Double Repeater can be used to cover larger distances. An Enecsys Double Repeater differs from a Single Repeater in that two antennas are used. One antenna can be connected via coaxial cable to an external antenna, positioned on the roof, close to the inverters. The second antenna communicates with the Gateway located in the house. D FT FT FT FT FT Intelligent Reliable Power FT FT FT FT FT FT FT Enecsys Double Repeaters are employed to improve the communication link between the inverters and the Gateway. The Enecsys Double Repeater is a 'plug and play' device; it is quickly and easily installed. The Enecsys Double Repeater should be installed within the roof-space of the building and positioned within easy connection distance of a mains supply AC power source. 2. Installation Double Repeater User Manual FT FT FT FT FT ANTENNA 5V DC IN POWER CABLE CONDUIT RP SMA CONNECTORS FIGURE 2. The Enecsys Double Repeater. © ENECSYS 2010. All rights reserved. D Intelligent Reliable Power FT FT FT FT FT FT FT Attach the antenna to the RP SMA connector on the right hand side of the Enecsys Gateway. FT FT 1. Attach the antenna to the lower SMA plug on the right hand side of the Repeater, screw the antenna into place in a clockwise direction. FT FT 2. Move the antenna into an upright position. FT FT FT FT FT 2.1 Attaching the internal antenna Double Repeater User Manual FT RP SMA CONNECTOR ANTENNA FIGURE 3. Attaching the antenna. © ENECSYS 2010. All rights reserved. D FT FT FT FT FT Intelligent Reliable Power FT FT FT FT 2.2 Mounting the Enecsys Double Repeater Double Repeater User Manual FT FT FT The Enecsys Double Repeater can be either free standing or wall mounted. In each case the Enecsys Double Repeater should be installed in a location where it is unlikely to be moved, indoors, away from heat sources and out of direct sunlight. If choosing a free standing Enecsys Double Repeater installation simply place the Enecsys Double Repeater within reach of a power source. It is recommended that the Enecsys Double Repeater be placed as high as possible within the building such as the loft space. FT FT FT FT FT FIGURE 4. The Enecsys Double Repeater reverse showing mounting points and distances. © ENECSYS 2010. All rights reserved. ADHESIVE FIXING POINTS CABLE TIE FIXING POINT 50 mm D FT FT FT FT FT Double Repeater User Manual Intelligent Reliable Power FT FT FT FT 2.3 Wall mounting the Enecsys Double Repeater (adhesive pad method) FT FT FT When mounting an Enecsys Double Repeater always ensure that you have connected the power supply and antenna to the device before the final fit. Locate the Enecsys Double Repeater away from metal structures. The adhesive pad placement areas are shown in Figure 4 on page 8. FT FT FT FT 1. Ensure that the back-plate of the Enecsys Double Repeater and the wall or mounting surface is clean from dust and grease. FT 2. Connect the supplied external 5V DC power supply to a mains supply AC power source. 3. Connect the supplied external 5V DC power jack-plug to the DC power port on the reverse of the Enecsys Double Repeater, thread the cable through the semi-circular channel on the backplate of the Enecsys Double Repeater, this will help to keep the cable in place and prevent it from becoming detached. 4. Remove the backing material from one of the double sided adhesive pads and place firmly onto the fixing points on the back of the Enecsys Double Repeater. Complete the process for the remaining two double sided adhesive pads. 5. Remove the remaining backing material from the adhesive pads attached to the back-plate of the Enecsys Double Repeater, press the Enecsys Double Repeater firmly into place on the wall/mounting surface. © ENECSYS 2010. All rights reserved. D FT FT FT FT FT Double Repeater User Manual Intelligent Reliable Power FT FT FT FT 2.4 Wall mounting the Enecsys Double Repeater (screw fixed method) FT FT FT When mounting an Enecsys Double Repeater always ensure that you have connected the power supply and antenna to the device before the final fit. The screw fixing points are shown in Figure 4 on page 8. FT FT FT FT 1. Attach the antenna to the SMA plug on the right hand side of the Enecsys Double Repeater, screw the antenna into place in a clockwise direction. 10 6. Line up the back plate holes of the Enecsys Double Repeater with the screws on the wall and then slide the Enecsys Double Repeater down to fix the unit in position. FT 5. Mark two horizontal spots on the wall 50 millimetres apart, install the screws into the wall. 4. Using the wall mount template locate the desired position of the Enecsys Double Repeater; ensure that there is adequate free-space around the Enecsys Double Repeater to allow for any future movement or maintenance of the device. 3. Select the appropriate location for mounting the Enecsys Double Repeater. © ENECSYS 2010. All rights reserved. 2. Connect the 5V DC power supply jack-plug to the DC power port on the reverse of the Enecsys Double Repeater, thread the cable through the semi-circular channel on the back-plate of the Enecsys Double Repeater, this will help to keep the cable in place and prevent it from becoming detached. D FT FT FT FT FT Intelligent Reliable Power FT FT FT FT FT FT FT 1. Ensure that the cable tie is of the correct width and length. When mounting a Enecsys Double Repeater always ensure that you have connected the power supply and antenna to the device before the final fit. There may be situations where it is not possible to mount the Enecsys Double Repeater using the screw fixed or adhesive pad method. A cable tie can be utilised to fix the Enecsys Double Repeater to an internal pillar or suitable structure. 2.5 Mounting with a cable tie Double Repeater User Manual FT FT FT FT FT 2. Run the cable tie through the cable tie fixing point on the back of the Enecsys Double Repeater. 3. Wrap the cable tie around the internal pillar or suitable mounting object and secure. CABLE TIE FIGURE 5. Mounting with a cable tie. © ENECSYS 2010. All rights reserved. 11 D FT FT FT FT FT Intelligent Reliable Power FT FT FT FT 2.6 Installing the external antenna Double Repeater User Manual FT FT FT When installing an external antenna always make sure that cable entry to building is waterproofed. Always ensure that the cable isn't arranged such that water or condensate can run down coaxial cable and onto the repeater. FT FT FT FT 12 © ENECSYS 2010. All rights reserved. 6. Secure the external coaxial. 5. Connect the SMA connector (male) to the upper SMA connector (female) on right hand side of the Enecsys Double Repeater, screw the connector into place in a clockwise direction. FT 4. Feed the coaxial cable through the installed cabling conduit and into the loft space of the building, use cable ties to hold the co-axial cable in place. 3. Connect the co-ax cable the bottom of the external antenna and screw into place. 2. Secure the external antenna to the mounting rack of the solar array or other suitable structure using two self-tapping screws. Cable ties may also be used to hold the antenna in a secure position. 1. Ensure that you have enough coaxial cable to reach from the mounting point to the Enecsys Double Repeater. D FT FT FT FT FT Intelligent Reliable Power FT FT FT FT 2.7 Turning the Enecsys Double Repeater on Double Repeater User Manual FT FT FT The Enecsys Double Repeater comes supplied with an external 5V DC power supply. The power adaptor serves as the disconnect device - a socket outlet in accordance to the national wiring codes for the country shall be installed near the equipment and shall be easily accessible. To turn the Enecsys Double Repeater on feed the power cable through the power cable conduit, attach the 5V DC power supply jack-plug from the power port on the reverse of the Repeater. FT FT FT FT FT 5V DC IN FIGURE 6. Connecting the Enecsys Double Repeater’s power supply. © ENECSYS 2010. All rights reserved. 13 D FT FT FT FT FT Intelligent Reliable Power FT FT FT FT 2.8 Turning the Enecsys Double Repeater off Double Repeater User Manual FT FT FT The Enecsys Double Repeater comes supplied with a 5V DC external power supply. The power adaptor serves as the disconnect device - a socket outlet in accordance to the national wiring codes for the country shall be installed near the equipment and shall be easily accessible. FT FT FT FT FT 5V DC DISCONNECT FIGURE 7. Disconnecting the Enecsys Double Repeater’s power supply. © ENECSYS 2010. All rights reserved. 14 R Intelligent Reliable Power FT FT FT FT FT FT FT FT FT Input: 100-240V AC 50-60Hz 0.3A. Plug-top P.S.U. FT FT Mains FT FT FT FT FT Power 3. Technical specification Double Repeater User Manual FT Output; 5V DC, 1.2A. with 2.1mm jack. Table 1: Power adapter. Operating Temperature Temperature range 10°C to +40°C. Table 2: Operating temperature. Interface Specifications Ethernet Interface RJ45, 10Base-T or 100Base-TX. Table 3: Interface specification. © ENECSYS 2010. All rights reserved. 15 Intelligent Reliable Power FT FT FT FT FT FT FT FT FT FT FT Table 4: Life expectancy. FT FT FT FT FT 12 months warranty. Usable lifetime Life Expectancy Double Repeater User Manual Fixed Internal Antenna FT 2.4 GHz. Peak gain 2.0 dBi. Polarisation Linear. Connector SMA Male. Dimensions 139 x 13mm. Frequency range 1/2 Wave Element. Radiating element Table 5: Fixed antenna. © ENECSYS 2010. All rights reserved. 16 Intelligent Reliable Power FT FT FT 139 x 13mm Dimensions SMA Male FT Connector -13 dB FT Return loss Linear FT FT Polarisation 2.0 dBi FT FT Peak gain 2.4 GHz FT FT Frequency range FT FT FT FT FT 1/2 Wave Element Radiating element *External Antenna Double Repeater User Manual FT Table 6: External Antenna. *External Antenna - For adetailed technical description of installation of the external antenna please refer to external antenna installation guide. © ENECSYS 2010. All rights reserved. 17 D FT FT FT FT FT Intelligent Reliable Power FT FT FT FT FT FT FT FT FT FT FT FT 18 © ENECSYS 2010. All rights reserved. Enecsys Double Repeaters conform to the following compliance codes. IC: 9052A-DEREP01 FCC: YIWDEREPEATER0001 Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device. Changes or modifications made to this device that are not expressly approved by Enecsys Ltd may void the user's authority to operate the equipment. Electrical Product Safety IEC 60950-1:2005 (2nd Edition); Am 1:2009; Compliance with National Differences :IEC60950_1B attachment EN60950-1:2006/A11:2009/ A1:2010 EMC EN 301 489-17 V2.1.1 - ElectroMagnetic compatibility and Radio spectrum Matters (ERM); ElectroMagnetic Compatibility (EMC) standard for radio equipment and services; Part 1: Common Technical Requirements. Spectrum EN 300 328 V1.7.1 - (Radio Module) Electromagnetic Compatibility and Radio Spectrum Matters (ERM) Wideband transmission systems; Data transmission equipment operating in the 2.4GHz 4. Compliance Double Repeater User Manual D FT FT FT FT FT Double Repeater User Manual Intelligent Reliable Power FT FT FT FT FT FT FT Please print this manual once and then keep it in a safe place for future reference. If you intend to dispose of this manual please recycle. FT FT FT FT 5. Printing ISM band and using wideband modulation techniques; Harmonised EN covering essential requirements under article 3.2 of the R&TTE Directive. FT © ENECSYS 2010. All rights reserved. 19 Enecsys Limited Harston Mill, Royston Rd Cambridge, CB22 7GG, UK T: +44 (0) 1223 792 101 F: +44 (0) 1223 792 103 E: info@enecsys.com www.enecsys.com Registered Office: Enecsys Limited, 24 Hills Road, Cambridge, CB2 1JP, England Registration No: 04832321 Document reference: ENEC-DOC-012
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : Mark.Gleeson Create Date : 2010:09:02 12:08:02Z Modify Date : 2010:09:02 12:26:57+01:00 Has XFA : No XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Format : application/pdf Title : Double Repeater User Manual.book Creator : Mark.Gleeson Creator Tool : FrameMaker 9.0 Metadata Date : 2010:09:02 12:26:57+01:00 Producer : Acrobat Distiller 9.3.3 (Windows) Document ID : uuid:3cec521d-7baf-4d4e-8bf5-e51085876160 Instance ID : uuid:1c6e3baf-19a4-4f33-af09-6f113f0f17ce Page Mode : UseOutlines Page Count : 22EXIF Metadata provided by EXIF.tools