Energate ZRM10 ZigBee Radio Module User Manual ZRM10 Radio Module

Energate Inc. ZigBee Radio Module ZRM10 Radio Module

user manual

Download: Energate ZRM10 ZigBee Radio Module User Manual ZRM10 Radio Module
Mirror Download [FCC.gov]Energate ZRM10 ZigBee Radio Module User Manual ZRM10 Radio Module
Document ID1041410
Application IDDq+kPRCOto3JXk0qwp7P2g==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize9.96kB (124468 bits)
Date Submitted2008-12-09 00:00:00
Date Available2008-12-09 00:00:00
Creation Date2008-12-03 09:25:44
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2008-12-03 09:25:44
Document TitleMicrosoft Word - ZRM10 Radio Module User Manual
Document CreatorPScript5.dll Version 5.2.2
Document Author: rsmith

ZRM10
Radio Module User Manual
December 3, 2008
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
Page 1
Table of Contents
Introduction ................................................................................................................................................3
1.1
Key Features ....................................................................................................................................... 3
Mechanical Specifications ..........................................................................................................................3
2.1
General Mechanical Specifications.....................................................................................................3
2.2
28-pin Connector Specifications .........................................................................................................3
Radio Interface Specifications ....................................................................................................................5
3.1
Introduction ........................................................................................................................................ 5
3.2
General Specifications ........................................................................................................................5
3.3
Power Supply ......................................................................................................................................6
3.4
Radio Transmitter Specifications ........................................................................................................6
3.5
Radio Receiver Specifications .............................................................................................................7
3.6
Antenna Specifications .......................................................................................................................7
4.0
Regulatory Requirements (FCC and IC) ..................................................................................................8
4.1
RF Exposure Warning..........................................................................................................................8
4.2
Labelling Requirements ......................................................................................................................8
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
Page 2
1
Introduction
This document is the User Manual for the Energate ZRM10 Radio Module. This Radio
Module can be integrated into any number of products that require wireless connectivity using the
ZigBee protocol.
1.1
Key Features
•
•
•
•
•
•
•
Utilizes Ember EM250 ZigBee System-on-a-Chip (SoC)
RF Performance Optimized and Guaranteed
− Frequency: 2405-2480MHz (ZigBee Ch11 to 26)
− Data Rate: 250kb/s
− Transmit Power: 100mW (Typical)
− Receiver Sensitivity: -95dBm (Typical) for PER=1%
Small Form Factor
17 GPIO Connections
Supply Voltage: +3.3 VDC (Typical)
Operating Temperature: -40 to 85 °C
PCB Mount Chip Antenna: +1.5dBi (Peak Gain)
Mechanical Specifications
2.1
General Mechanical Specifications
Parameter
2.2
Min
Typ
Max
Units
Dimensions (L)
43.6
mm
Dimensions (W)
29.3
mm
Dimensions (T)
5.1
mm
Notes
Total thickness.
28-pin Connector Specifications
The 28-pin connector that is used on the Energate ZRM10 Radio Module is the Samtec FTS-114-03-
L-DV.
Below is the pin-out of the Radio Module.
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
Page 3
Function
Secondary
Function
Pin
Signal
Comment
VBRD
+3.3V supply to the ZRM10.
VBRD
+3.3V supply to the ZRM10.
GPIO_1
MISO (SPI)
SDA (I2C)
Connected to SPI Flash (DOUT) on the module.
GPIO_2
MSCLK (SPI)
SCL (I2C)
Connected to SPI Flash (CLK) on the module.
GPIO_12
GPIO_0
GPIO_3
MOSI (SPI)
Connected to SPI Flash (DIN) on the module.
GPIO_11
/CS
Connected to SPI Flash (/CS) on the module.
GPIO_5
ADC1
10
GPIO_4
ADC0
11
GPIO_7
LED
12
GPIO_6
ADC2
13
GPIO_9
TXD
14
GPIO_8
15
RSTB
RSTB
16
GPIO_10
RXD
17
GND
18
GND
19
SIF_CLK
20
SIF_MISO
21
SIF_MOSI
22
SIF_LOADB
ADC3
Connected to LED D1 on the module. D1 is currently NO
POP.
UART connection to EM250.
UART connection to EM250.
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
Page 4
Pin
Signal
23
GPIO_16
24
GPIO_15
25
GPIO_14
26
GPIO_13
27
GND
28
GND
Function
Secondary
Function
/WP
Comment
Connected to SPI Flash (/WP) on the module.
Radio Interface Specifications
3.1
Introduction
The following section describes the radio specifications for the ZRM10 Radio Module. The design
utilizes an Ember EM250 ZigBee System-on-a-chip (SoC) to provide wireless connectivity using the IEEE
802.14.5a protocol. The EM250 is connected to an external RF power amplifier which boosts the
transmitted RF signal power to 100mW (Typ).
3.2
General Specifications
Parameter
Min
Operating Frequency
2405
RF data rate
Ambient operating
Temperature
Regulatory Compliance
Typ
Max
Units
2483.5
MHz
250
-40
+24
Notes
kb/s
+85
°C
FCC Part15 (Sub C)
Full modular
approval.
Industry Canada RS-210 (Issue7)
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
Page 5
3.3
Power Supply
Parameter
Min
Typ
Max
Units
Voltage
3.1
3.3
3.5
Notes
Current, Tx
185
mA
Conditions:
Current, Rx
38
mA
1) Pout=+20dBm
(100mW)
Current, Idle/Napping
8.5
mA
µA
2) Vcc=+3.3V
Current, Standby
3.4
Radio Transmitter Specifications
The RF transmitter power is +20dBm (100mW) for the Channels 11 through 25. Due to
requirements specified in FCC Regulations (Part 15, Restricted Frequency Bands), the RF transmit power is
reduced for Channel 26 (2480 MHz).
Parameter
Min
Typ
Transmit Output Power
(2405-2475MHz, Ch11-Ch25)
20
Transmitter LQI
255
Max
Units
Notes
dBm
100mW (Typ)
As measured with a
CW tone at the
transmitter output.
Transmit frequency offset
(24C)
-10
10
ppm
Transmit frequency offset
-40
40
ppm
(-40C to +85C)
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
Page 6
3.5
Radio Receiver Specifications
Parameter
Min
Receiver maximum input
signal (PER=1%)
Receiver sensitivity
(PER=1%)
3.6
Typ
Max
Units
dBm
-95
dBm
Notes
Antenna Specifications
The antenna used on the ZRM10 is a chip antenna with these specifications:
Parameter
Min
Typ
Max
Units
Antenna Gain (Peak)
1.5
dBi
Antenna Gain (Average)
-2.3
dBi
Radiation Efficiency
(Average)
70
Notes
NOTE: When integrating the Energate ZRM10 Radio Module into other products, only the antenna
provided on the Radio Module can be used. If any other antenna is used, this is a violation of FCC and
Industry Canada regulations.
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
Page 7
4.0 Regulatory Requirements (FCC and IC)
The Energate ZRM10 Radio Module device complies with FCC (Part 15) and Industry Canada (RS210) regulatory requirements. Operation of the ZRM10 is subject to the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, including interference that may cause
undesired operation.
The Energate ZRM10 Radio Module can be integrated into a variety of different products. With this
in mind, the ZRM10 has obtained Full Modular Approval from both the FCC and IC. This approval means
that the ZRM10 is designed in such a way that it is a self-contained entity. The ZRM10 can then be attached
to ANY product without any further testing by the FCC or IC for (radio) regulatory compliance in the 24002483.5MHz band.
4.1
RF Exposure Warning
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This device must be installed in accordance with the provided instructions and must be
operated with minimum 20 cm spacing between the antennas and any person’s body during wireless mode
of operation. Further, this transmitter must not be collocated and operated in conjunction with any other
antenna or transmitter.
Changes or modifications not expressly approved by the party responsible for compliance could
void the user’s authority to operate the equipment.
4.2
Labelling Requirements
When integrating the Energate ZRM10 Radio Module into other products, the following
requirements must be met:
1. Use only the antenna provided.
2. Operate the module according to the specifications listed in this User Manual.
3. Include a label clearly visible on the exterior of the end product which states:
Contains FCC ID: WUR-ZRM10
IC ID: 8022A-ZRM10
NOTE: It is mandatory that end users of the Energate ZRM10 consult all FCC and IC documentation for use of
a product with modular approval, and ensure any products comply with all listed guidelines and additional
testing that may be required.
THIS DOCUMENT CONTAINS CONFIDENTIAL INFORMATION PROPRIETARY TO ENERGATE INC. NO PART OF ITS CONTENTS MAY BE
DISCLOSED OR CONVEYED TO, USED BY, OR COPIED TO A THIRD PARTY WITHOUT PRIOR WRITTEN CONSENT BY ENERGATE INC.
Page 8

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 8
Producer                        : GPL Ghostscript 8.15
Create Date                     : 2008:12:03 09:25:44
Modify Date                     : 2008:12:03 09:25:44
Title                           : Microsoft Word - ZRM10 Radio Module User Manual
Creator                         : PScript5.dll Version 5.2.2
Author                          : rsmith
EXIF Metadata provided by EXIF.tools
FCC ID Filing: WUR-ZRM10

Navigation menu