Enlighted CS-D2 Intelligent Light Sensor for Smart Networked Energy Saving Lighting Systems. User Manual PowerPoint Presentation
Enlighted, Inc. Intelligent Light Sensor for Smart Networked Energy Saving Lighting Systems. PowerPoint Presentation
Contents
- 1. Users Manual 1 v2
- 2. Users Manual 2 v2
Users Manual 1 v2
FCC and Industry Canada Compliance Information This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. This device complies with Part 15 of the FCC Rules and Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: • this device may not cause harmful interference, AND • this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by Enlighted Inc. could void the user's authority to operate the equipment. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions suivantes: • l'appareil ne doit pas produire de brouillage, ET • l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement. Copyright © 2015 Enlighted Inc. All rights reserved. All other brand or product names are trademarks of their respective companies or organizations. Compact Sensor (CS-D2) Installation Instructions Technical Support For questions regarding the installation or operation of this product, contact Enlighted Technical Support: support@enlightedinc.com Company Contact Information Location: 930 Benecia Ave, Sunnyvale, CA 94085 Phone: +1.650.964.1094 Web: enlightedinc.com Figure 1: Compact Sensor (CS-D2) CE This device complies with the essential requirements and other relevant requirements of the R&TTE Directive (1999/5/EC). The equipment is Class 1 radio equipment which can be placed on the market and be put into service without restrictions in accordance with article 1(3) of Commission Decision 2000/299/EC (Version July 2014). Shipped Components • Enlighted Compact Sensor Unit Items you may Need • Lock Nut for fixture mounting or • Spring Arms for Tile mounting • 18 AWG solid copper wire, rated >=300v Tools you may Need • 1” Drill bit • Hand drill • Wire stripper Model: CS-D2 FCC ID: AQQ-CS-D2 IC: 10138A-CSD2 Page 5 Page 6 93-01182-02 Rev04 082115 Page 1 Caution Fixture Mount Sensor Installation • Installation and maintenance must be performed by a qualified electrician in accordance with local, state, and national electrical codes (NEC) and requirements. Tile Mount Sensor Installation Step Step 1. Description Troubleshooting Problem Solution Switch off the circuit breaker supplying power to the light. LED not on Check power and wiring The sensor is designed to mount in a ½ inch trade size knockout on a fixture. This sensor is for use with the Philips XSR driver. Solid red LED Sensor fault – replace Red blinking LED Incompatibility between LED driver and sensor – replace LED driver and if not resolved, replace sensor Description 1. Switch off the circuit breaker supplying power to the light. The sensor is designed to mount in a 1-inch hole in the ceiling tile. This sensor is for use with the Philips XSR driver. Determine the location for the sensor in the fixture and cut an existing knockout (½ inch) in the fixture. See Figure 3. 3. Make a small circular cut (one-inch) in the ceiling tile. Thread the spring arms around the sensor. Insert the compact sensor through the hole in the fixture. Use the lock nut from behind the sensor to fasten the compact sensor. See Figure 4. 4. Measure the distance between the sensor’s installation location and the LED driver’s “SR connections,”. Cut two lengths of 18 AWG solid wire that are at least this length plus one inch. Strip each end of the two wires leaving 3/8 inch of exposed wire. 4. Measure the distance between the sensor’s installation location and the LED driver’s “SR connections,” and cut two lengths of 18 AWG solid wire that are at least this length plus one inch. 5. Strip each end of the two wires leaving 3/8 inch of exposed wire. 6. Insert one end of the pair of wires in the sensor’s wire holes and the other end in the LED driver’s “SR connections” wire holes. See Figure 6. 7. Turn the power on by switching on the circuit breaker. 5. Insert one end of the pair of wires into the LED driver’s “SR connections” wire holes, (see Figure 5), and pull the other end through the hole in the tile. See Figure 2. 6. Insert the free end of the pair of wires into the sensor’s wire hole. See Figure 2. 7. Push the spring arms together and insert the sensor through the hole in the tile. See Figure 2. 8. Turn the power on by switching on the circuit breaker. Note: For any reason, if you need to remove the two wires, push down on the tabs located on the rear of the sensor with a pointed device, and remove the wires while continuing to hold the tab down. Locknut Figure 4: Fixture Mount Sensor Spring arms To lamps Push the spring arms together and insert the sensor Figure 2: Tile Mount Sensor Page 2 To Enlighted sensor Figure 3: Sensor location in a fixture Page 3 Figure 5: Wiring Connection Page 4
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : Enlighted Create Date : 2015:08:21 13:09:59-07:00 Modify Date : 2015:08:21 13:10:01-07:00 Language : EN-US Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15 Metadata Date : 2015:08:21 13:10:01-07:00 Creator Tool : Acrobat PDFMaker 15 for PowerPoint Document ID : uuid:78a707ba-cd81-40b6-bc60-f21ed6036257 Instance ID : uuid:895491a1-25be-4db3-9ad7-534ba11ad7a1 Format : application/pdf Title : PowerPoint Presentation Creator : Enlighted Producer : Adobe PDF Library 15.0 Tag Template ID : TC038954999991 Page Layout : SinglePage Page Count : 2EXIF Metadata provided by EXIF.tools