Quick Start Manual
MANUAL-ODE (Rev A)

for more information visit:
www.enttec.com/ode

ENTTEC ODE
(PN 70305 OR 70306)

Box Contents

•

POE (power over ethernet) supported RJ45
connector (only on POE model PN 70306)

•

Open DMX Ethernet (pn:70305 or 70306)

•

Straight connect Ethernet lead (pn:79102)

•

Power Adapter (pn: 79114) if you have the POE
option, the power adapter is not included.

•

Do not expose the ODE to rain or moisture, doing
this will void the warranty

•

This user manual

•

•

CD including NMU (pn:79106)

Do not remove the cover, there are no serviceable
parts inside

•

This unit is intended for indoor use only

•

DMX ports are non-isolated, please isolate DMX
signal wherever possible to protect this unit from
accidental power surge.

Features
•

1 DMX port (5pin) - Male and Female connectors

•

1 Universe Art-Net to DMX node (Output mode)

•

1 Universe DMX to Art-Net (Input mode)

•

Setup done through Node Management Utility

•

Supports ESP and Art-Net protocols for DMX over
Ethernet

•

HTP Merging support : up-to 2 sources are
merged by default and, can be extended to
merge up-to 6 sources by purchasing additional
plugin.

•

1 RJ45 Ethercon connector (10/100)

•

Automatic multi voltage mains input

•

7V DC Power-supply supplied (not included with
the POE model: PN 70306)

Safety

Basic Setup
Right out of the box the ODE is factory configured to be a
DMX OUTPUT device, running on Art-Net Universe 0,0.
It can be either output or input, however, and can use any
possible universe in Art-Net or ESP modes. It has
configurable IP address as well. Use the free utility program,
Node Management Utility (NMU – available for Windows
and Mac), to change the configuration on your ODE.
Please note, ODE only supports static IP address (DHCP is
not supported) and comes with factory set IP address set to
10.a.b.c (where a,b,c relates to the Serial number of the ODE)
This IP address is also printed on the box (top label).
If NMU or any App has trouble finding ODE on your
network , please connect the ODE direct to your computer
1

Quick Start Manual
MANUAL-ODE (Rev A)

for more information visit:
www.enttec.com/ode

with your computer's IP address set to 10.0.0.1 and Netmask set to 255.0.0.0
Use NMU to change ODE IP address, modes (input or
output), protocol support (Art-Net or ESP) and the
universe the ODE sends or receives data on.
Once setup, any Art-Net supported software or App can
be used to send DMX out of the ODE. For recommended
apps, please check the website www.enttec.com/ode

LED Status
The ODE comes with four LED indicators located between
the DC power jack and the RJ45 ethercon connector.

Any suitable 3 to 5pin DMX adaptor can be used to connect
to 3pin DMX cables or fixtures. Please note the pinout,
before connecting to any non-standard DMX connector.

NMU configuration
NMU (Node Management Utility) is the free Windows and
OSX application used to manage compatible ENTTEC DMX
over Ethernet nodes including ODE and ODE-POE
NMU bypasses all your TCP/IP settings allowing you to
reconfigure nodes in a plug and play fashion, how ever they
are configured.
To employ the NMU, follow this set of instructions:
1. If you have not already done so, install the program
from the included CD, or download and install NMU
application
from
the
Enttec
website
:
www.enttec.com/nmu
2.

Ensure that your ODE is hooked up physically by
Ethernet cable to the same physical network as the
computer on which you will run the NMU.
This can be done directly to the ethernet port on
your computer or through a switch. When you plan
to use multiple ODEs you will need to use a switch.

1.

Status: This LED will blink when the ODE is
operating normally.

2.

Port Direction: The LED will be ON when the DMX
port is in Output mode, and OFF when the DMX
port is in input mode.

3.

Ethernet Link: This LED will be ON when there is
an Ethernet Link.

4.

Ethernet Activity: This LED blinks when there is
activity on the Ethernet network.

3.

Start the NMU application.

4.

Select the correct IP address from multiple networks
(if prompted by NMU), that is connected to ODE

5.

Press the Discovery button

6.

Once found, ODE will appear in the device list, with
it's IP address and configured name. Select the ODE
and click on configure button to get to the
Configure ODE window, from where most of the
settings can be changed.

DMX Connector pin out
5pin DMX OUT/ DMX IN:
•

Pin 1: Ground

•

Pin 2: Data -

•

Pin 3: Data +

•

Pin 4: NC

•

Pin 5: NC

2

Quick Start Manual
MANUAL-ODE (Rev A)

for more information visit:
www.enttec.com/ode

Firmware Update
To update the firmware on the ODE, you can perform a
simple operation using the NMU App. Follow Steps 1-6 as
described above in the NMU configuration section. Then
click the button at the bottom called “Update Firmware ...”
Upload the correct firmware file for the version of your ODE
(latest firmware is available at www.enttec.com/ode).
A small progress window will pop up showing the
percentage of completion achieved as the procedure
happens.

7.

At your option, you may choose to enter a new
name for the ODE in the Device Name field.
Calling it “Truss 1” or “Onstage Dimmers
Universe” may be convenient to your application,
for instance.

8.

If you need to adjust the IP Address for your
application, it may be done here. While many
users can expect the ODE to work fine with
factory default IP, some networks will be a bit
trickier. If it works for you as is, don't bother
changing anything here, but if you're trying to
troubleshoot, a valuable tip would be to choose
an IP which is similar in the first 3 numbers (but
distinct in the last) from other elements of your
lighting system. For further information about this
consult a Network Manager or IT expert who
knows your local Ethernet setup well.

9.

Choose which protocol you wish to use, between
Art-Net (default) and Enttec Show Protocol (or
ESP). Art-Net is supported very widely by other
hardware and software, so you have both options
available.

10. Universe and/or subnet may be configured as
needed, if this is to be the 1 st universe in your
setup, leave it at 0-0.
11. Port direction: when set to output (default), it
outputs DMX, and when set to input it receives
DMX and outputs Art-Net or ESP (as configured)
12. Once you have it all set up the way you'd like,
click on Save Config button to send this
information to the device.

When it reaches 100%, another window will alert you that it
successfully completed this operation and that you can Click
OK to refresh the list of devices which the NMU can see.

Since, ODE will reboot after a firmware update, please allow
a few seconds for it to be found by NMU. You can verify the
firmware version by the text at the bottom, which is
displayed when ODE is selected in the NMU device list

Emergency Firmware Recovery

In some rare cases, the ODE firmware might become
corrupted and support may instruct you to force a firmware
update, please follow this procedure.
With NMU opened :
Please Click on File->ODE Emergency Firmware Recovery
NMU will then guide you through the steps needed to
restore the ODE. Please follow as directed and reboot the
ODE as and when instructed. It is advisable to connect the
ODE direct to the computer (no switch or router) while doing
this procedure.

13. You can then close the application and use the
ODE right away. Congratulations, you're done!
3

Quick Start Manual
MANUAL-ODE (Rev A)

for more information visit:
www.enttec.com/ode

Art-Net Send Test

Specifications

NMU can also be used to troubleshoot the DMX output
on your ODE. Art-Net Test can be accessed from the top
menu: Artnet → Artnet Test or from within the ODE
configuration window (button called SEND Art-net …)

Due to continuous improvements and innovations of all
ENTTEC products, specifications and features are subject to
change without notice.
Item

Value

Input Voltage

90 – 260V AC

Input Frequency

50/60Hz

Weight

0.58 lbs / 0.26 kg

Shipped weight

0.68 lbs / 0.48 kg

Length

5.12” / 130mm

Width

2.36” / 60mm

Height

1.58” / 40mm

Op Environment

0°-50°C

Connectors

1x 5-Pin Male XLR for DMX input
1x 5-Pin Female XLR for DMX input
1x RJ45 Ethercon connector

Ordering Information
When first opened, the Art-Net is set to Disabled, please
set it to Enabled, and then you can use either the DMX
faders to test one or more DMX channels, or use the testpatterns from the options available.Set the universe to be
the same as configured on the ODE, and change the Send
to either broadcast or send direct to the ODE IP address

ODE Plugins

Add Extra functionality to your ODE using plugins. These
plugins can be enabled and configured using NMU. The
Plugin License Key is unique for each ODE and will only
allow you to activate the plugin for that ODE.
For purchase of ODE plugins and more information
please check the website: www.enttec.com/ode

ODE and related products can be ordered from our website
or through your ENTTEC dealer using the following part
numbers.
Part Number

Description

70305

ODE

70306

ODE with POE

79111

Autoswitching Power Supply 7V (Universal)

79111-US

Autoswitching Power Supply 7V (US only)

70041

ODE Truss Mount Kit

ENTTEC PTY LTD
17/5 Samantha Court
Knoxfield Victoria 3180
Australia
Tel: +61 3 9763 5755
Fax: +61 3 9763 5688

ENTTEC AMERICAS
604A Cornerstone Ct.
Hillsborough NC 27278
USA
Tel-Fax: (888) 454-5922
email sales@enttec.com

www.enttec.com

4

