Equinox Payments 00010 Point of Sale Terminal User Manual Layout 1

Equinox Payments LLC Point of Sale Terminal Layout 1

User Manual

iRMMM=c~ãáäóqbojfk^i=fkpq^ii^qflk=drfab`ljmif^k`bqbojfk^i=fkpq^ii^qflk=drfabbèìáåçñ=m~óãÉåíë8901 E. Raintree Dr, Suite 400, Scottsdale, Arizona 85260, USA  |  Tel:  480.551.7800  |  Fax:  480.551.7811© 2011-2014 Equinox Payments. All rights reserved. The Equinox logo is a trademark of Equinox Payments, LLCTM. All other products or services mentioned in this document are trademarks, service marks, registered trademarks or registered service marks of their respective owners.                          940660-001E Rev. B    08/14The user is cautioned that changes or modifications to the device(s) identified in this manual unless expressly approved by theparty responsible for compliance could void the user’s authority to operate this device. This is a class A device. In a domestic environment this device may cause radio interference in which case the user may be required to take adequate measures.•  FCC Part 15 B - Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.•  FCC ID: NVA00010 •UL Listed •RoHS •PCI PTS 3.xx with SREDiRMMM=c~ãáäóklqf`bpIf a power supply was NOT shipped with the L5X00s terminal or if there is NOT an immediately available power supply to use with theL5X00s, use the following when selecting and using a suitable power supply:•  Must use Equinox P/N 870066-004, or•  Must use a suitably safety Listed power supply, output rated 12-24Vdc 1A or greater and must be a certified Limited Power Source, marked LPS.To Clean Screen:  Apply distilled water or mildglass cleaner onto a soft, lint free cloth and gently wipe terminal screen.To Clean Terminal:  Apply distilled water or plastic-safe cleaner onto a soft, lint free cloth and gentlywipe terminal.NSmartCardReaderMSR SlotPorts (in the back)Cleaning the Device•Do NOT use industrial strength or an abrasive cleaner as it may damage or scratch the screen.• Do NOT immerse device in water (or liquid).•Do NOT spray water or cleaner into the MSR slot, Smart Card Reader or ports in the back.NScreent^okfkdWInserting a MicroSD CardPower down and remove all powerfrom terminal before installing card.Turn terminal over. Loosen tworetained screws on underside of ter-minal and remove top cap or con-tactless module. Card slot is accessible once top cap or contactless module is removed.Insert card (gold connectors down) intoMicroSD slot (as shown). Push card inuntil firmly seated in slot. Reinstall topcap or contactless module. Tighten tworetained screws to secure the top capor module to terminal. Contact Equinoxfor list of approved cards and format-ting information.OScrewsMicroSD Slot•  When so powered, this device is intended to be connected only to Power over Ethernet (PoE) networks that are not routed to the outside plant.klqbW=This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCCRules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in acommercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accor-dance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residen-tial area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device maynot cause interference, and (2) this device must accept any interference, including interference that may cause undesired operation of the device.(940660-001E)Applicable to L5200 and L5300Applicable to L5200 and L5300NMSR SlotInspecting SlotsClosely, visually inspect the MSRSlot for any foreign objects thatmay obstruct, hamper or preventthe sliding of your card thru theMSR Reader.If any foreign objects are found,do NOT use and notify the appro-priate person immediately for thedevice may be compromised.If no foregin objects exist, use thedevice as normal.OSmart Card Reader SlotClosely, visually inspect the SmartCard Reader Slot for any foreignobjects that may obstruct, hamperor prevent your smart card frombeing read.If any foreign objects are found,do NOT use and notify the appro-priate person immediately for thedevice may be compromised.If no foregin objects exist, use thedevice as normal.
iRMMM=c~ãáäó=qÉêãáå~ä=fåëí~ää~íáçå=dìáÇÉEquipment ChecklistPower & Cable Connections Stylus PenL5000 Family Terminal(L5300 shown for illustration)The iRMMM=c~ãáäó=qÉêãáå~ä=fåëí~ää~íáçå=dìáÇÉprovides basic terminal setup information.Note: Images in this guide may not exactly match your device (e.g., contactless and communication modules are optional).Additional accessories are available for purchase. Contactyour Equinox Sales Associate for specific options.Upon receipt of the terminal, immediately change the defaultSetup password. Changing the password can be done terminal by terminal or via download. For instructions onchanging the password, contact your Equinox Sales Engineeror Equinox Technical Support at 1-877-497-3726.Additional Accessories (Contact your Equinox Sales Associate for current information and availability.)If required, remove plug fromround opening in stylus holder(as shown) by pushing up fromunderside. To insert, push pluginto round opening from above.Insert the connector end of thestylus pen (as shown).StandInstallationIf required, remove smart cardreader plug from wrapper. Insertplug into smart card receptacleslot (as shown). Insert metal stand prongs into 3 standslots on underside of terminal. Slideterminal firmly into place on stand.Power Cord(if provided)NL5000 terminal OIf required, insert 12-24 volt Powered RS232cable into RS232+POWER port (as shown).Note: Power supply required for RS232 cable. See RS232cable note in Additional Accessories, below.If required, insert the USB cable into the USBHost port (as shown).Note: Supports connection of certain peripheral USBdevices to OS/FPE32.PIf required, insert the 12-24 volt Powered USB cableinto the PUSB port (as shown).Note: Port used to interface to another USB port on a PC or POS terminal.RS232 + POWER port (standard)Smart CardReader PlugQIf required, insert the cable into the 100 BASE-Tport (as shown).  Note: Used to download images, forHTMS support, or for enabling financial transactions using SSLover the internet.If required, insert cables into correspondingCommunication Module ports.Note: Contact your Equinox Sales Associate for specificCommunication Module options.100 BASE-T port (standard)RS232 Cable(P/N 810408-001)To be used with Power Supply(P/N 870066-004)Powered USB Cable12-volt (P/N 810349-001)24-volt (P/N 810349-002)Power Supply (P/N 870066-004)Requires a Power CordPower Cord(P/N 810003-007)Contactless Reader Module(P/N 020380-601E)Communication Module (P/N 01036x-1xxE)Smart Card Reader Plug(P/N 600672-001)Capacitive Activated Stylus Pen(P/N 040367-001E)Stylus PenTurn terminal over. If required, connect PowerCord to Power Adapter. Insert Power AdapterCable connector into POWER port and thenturn counter-clockwise to lock. Insert thePower Cord plug into wall receptacle.Standard ports:- mrp_- NMM=_^pbJq=bíÜÉêåÉí- opOPOHmltbo- rp_=eçëí- bíÜÉêåÉí- q~áäÖ~íÉJ=mçïÉê=çîÉê=bíÜÉêåÉí=EmçbF=USB Host port (standard)PowerportStylusHolderStandSlotsStylus Holder Plug(P/N 600725-002E)Smart Card Reader PlugP/N 600672-001SArrange installed cables through opening at back of terminal.Insert bracket and press into grooves to left and right of open-ing to secure.  If done correctly, the PWR label aligns with thePOWER label on the terminal (as shown). Note: Positionlargest opening in bracket toward left side of opening.Ethernet port(optional)CableManagementBracketRNStylus PenConnectorStandardportsPowered USB port (standard)TUOptionalCommunicationModulePorts available onCommunication Module:Tailgate port (12V powered, optional)Wrap stylus cable along back of terminal and secure in retention clip(as shown).Smart CardReader Plug (if provided)Cable ManagementBracketPower Supply(if provided)Retention ClipPWRLabelOCable LockIf required, insert customer-provided cable lock intoKensington®slot. Loop cablearound permanent object tosecure terminal in place.SlotCable LockCable ManagementBracket(P/N 600671-001)BaseCapApplicable to L5200 and L5300Stylus HolderPlugStylus HolderPlugStylus Holder PlugP/N 600725-002E`~ÄäÉmLk=MNMPSMJNMOb=ëÜçïå=Ñçê=áääìëíê~íáçåt^okfkdW=Prior to using this device, read these instructions carefully for important information, including any use restrictions that may apply.• Use only the power adapter provided with this device. Non-compliant power adapters may damage this device, thereby invalidating its warranty.•  This device must be connected to the correct electrical supply. Connection to an inappropriate supply may damage or destroy this device.•  Do not power ON this device in a flammable atmosphere, such as a petrol station, chemical depot, etc.•  Only operate this device within the temperature range of 0°C - 45°C (32°F - 113°F).•  Do not expose this device to temperatures above 60°C (140°F).•  Do not use this device if it is visibly damaged.•  Do not disassemble, incinerate, or crush this device.•  Keep this device out of reach of children and pets.`^rqflkWUsers of this device are cautioned to only use accessories and peripher-als approved by Equinox Payments. Changes to this device or use ofaccessories other than recommended or approved by Equinox Paymentsmay result in the loss of the user’s authority to operate the device.Powered Supply AdapterRight Angle(P/N 810411-001)USB Cable (P/N 810371-012)

Navigation menu