C O N T E N T S  2  Product and personal safety guidelines 7  Regulatory information 10  About EARU 1112 14  Checking package contents 15  Installing EARU 1112 19  Setting EARU 1112 21    Open Source Software Notice
Product and personnel safety guidelines This section contains safety guidelines that you must follow for personal safety and to operate the equipment correctly. LG-Ericsson documentation contains precautionary messages and safety procedures that refer to specific tasks or conditions. You must read and follow all precautionary messages before you start to work on the equipment. Audience Personnel working directly on equipment must be • trained, authorized, and qualified to carry out the tasks required • able to follow safety guidelines specific to the product and all local customer-specific safety procedures Precautionary messages To prevent personal injury, equipment damage, and service interruptions, you must follow all precautionary messages in LG-Ericsson documentation and all local safety standards required by your service provider. The following precautionary messages appear in LG-Ericsson documentation:
Safety standards LG-Ericsson products conform to all relevant safety standards. The EARU 1112 complies with the following safety standards: •IEC/EN 60950-1:2001+A11:2004—Information technology equipment - Safety, Part 1 : General requirements • IEC 60825-1:2001 and IEC 60825-2:2004—Safety of Laser Products • FDA 21 CFR 1040—Performance Standards for Light-Emitting Products Laser radiation—eye safety hazards LG-Ericsson optical products use laser or light-emitting diode (LED) sources that emit light energy into optical fibers. This energy is within the red (visible) and infrared (not visible) areas of the electromagnetic spectrum.FDA 21 CFR 1040—Performance Standards for Light-Emitting Products Laser radiation hazards When operating the product normally, with all optical connectors in position and correctly terminated, the optical radiation is completely enclosed. The system is a Class 1(IEC)/Class I (FDA) product, regardless of the power transmitted within the optical fiber. If you have unterminated optical cables (breaks in the fiber-optic cable or disconnected connectors) the output from circuit packs containing optical transmitters does not exceed Class 1 (IEC)/Class I (FDA) and is therefore considered safe under all reasonably foreseeable conditions. The following text includes additional information on the laser for the EARU 1112 .   Using optical fibers All activity described herein regarding the optical interface of the EARU 1112 is intended only for trained personnel operating under the direction of the service provider. Users and homeowners should not attempt to access or disconnect the optical interface or damage the optical cable. Consult with the service provider before undertaking any action involving the optical interface. Laser wavelength 1530 - 1600 nm Maximum laser output power <= 0.299 mW (-5.25 dBm) Standards: IEC 60825-1:2001 Edition 1.2 FDA 21 CFR 1040.10:2000
Handling optical fibers When you work with optical fibers, you must take the following general precautions: • Wear safety glasses when you install optical fibers.  • Do not look into the opening of an optical fiber, or the opening of an optical fiber connector, if the optical fiber is active or the unit has the power turned on. • Avoid direct exposure to optical fiber ends or optical connector ends where you can access the laser signal directly. • Clean your hands after you handle optical fibers. Small pieces of glass are not always visible and can damage your eyes.  • Do not handle pieces of optical fiber with your fingers. Use tweezers or adhesive tape to lift and discard any loose optical fiber ends. • Wear rubber gloves when you clean optical connectors. The gloves prevent direct contact with the isopropyl alcohol and prevent contamination of the ferrules with skin oils. • Place all optical fiber clippings in a plastic container provided for that purpose. • Handle optical fibers with caution. Place the optical fibers in a safe location during installation. • Protect all optical fiber connectors with clean dust caps at all times. • Follow the manufacturer instructions when you use an optical test set. Incorrect calibration or control settings can create hazardous levels of radiation. Splicing optical fibers When you must look at a spliced optical fiber with a small magnifier, take the following precautions: • Power off all laser sources to the optical fiber or disconnect the remote optical fiber end from the laser sources before you start splicing. Make sure that all laser sources remain disconnected or have the power turned off. • Disconnect all optical test sets from the optical fiber before you start splicing. The connections can be local or remote. • Use only the optical instruments approved by your company.
Repairing optical fibers When an accidental break occurs in the optical fiber, do the following: • Report the location of the damaged optical fiber to both the service provider and the field repair personnel. • Power down all laser sources to the optical fiber or disconnect the remote optical fiber end from the laser sources. Working with power  Other Warnings and cautions WARNINGS
CAUTIONS        Warranty: Customers can receive repair services for this product underspecified conditions. This warranty does not cover failure or damage ofthe product caused from, using a power adapter other than the one provided, PC failures, data loss, or negligent treatment of the product. For questions or to report damage or failures contact your service provider.
Regulatory information This chapter contains the following information: • a list of global technical standards (electromagnetic compatibility, safety) to which the EARU 1112 complies • a country-by-country list of specific regulatory text required by national authorities • information on the regulatory labels affixed to the product (artwork and location on the product) The list of global technical standards provided in this chapter is not exhaustive. The standards listed are generally regarded as the primary applicable electromagnetic compatibility (EMC) and safety standards. The conformity status on additional national and international standards not listed in this section can be provided upon request. Compliance to applicable technical standards and regulations The EARU 1112 meets or exceeds the following standards and requirements: • (CFR Title 47, Chapter 1) FCC Part 15, Subpart B, Class B (USA) • ICES-003, Issue 4, Class B (Canada) • European Union EMC Directive (2004/108/EC) • European Radio and Telecommunications Terminal Equipment Directive (R&TTE,1999/5/EC) • European “Low Voltage” Directive (2006/95/EC) • EN 55022:2006 - Class B (European Community, Australia and New Zealand) • EN 55024:1998 +A1:2001 +A2:2003 (European Community) • EN 300 386 V1.3.3 (European Community, Australia and New Zealand) • Anatel Resolution Number 442:2006 (Brazil) • GB 9254-2000 (China) • VCCI V-3/2007.04 (Japan) • Australian Radiocommunications Labelling (Electromagnetic Compatibility) Notice 2008 • CAN/CSA-C22.2 No. 60950-1 (Canada) • UL Std No. 60950-1 (USA) • IEC/EN 60950-1:2001+A11:2004 (European Community) • IEC/EN 60825-1:2001 • IEC/EN 60825-2:2004 • AS/NZS 2211.1:2004 (Australia and New Zealand) • AS/NZS 2211.2:2006 (Australia and New Zealand) • Resolution 238:2000 (Brazil) • GB 4943-1995 (China)
Country-specific regulatory information Canada This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. United States of America This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected (consult with the service provider before proceeding). • Consult the service provider or an experienced radio/TV technician for help. Repairs to certified equipment should be coordinated by a representative designated by your service provider. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the service provider cause to request the user to disconnect the equipment. Do not attempt to repair this equipment. If you experience trouble, contact the service provider.  FCC Warning This equipment generates or uses radio frequency energy. Changes or modifications to this equipment may cause harmful interface unless the modifications are expressly approved in the instruction manual. The user could lose the authority to operate this equipment if an unauthorized change or modification is made.  European Union The EARU 1112 conforms with the essential requirements of Directive 2004/108/ EC (EMC Directive), Directive 2006/95/EC (Low Voltage Directive) and Directive 1999/5/EC (Radio and Telecommunications Terminals Equipment) through compliance to the following harmonized standards: • EN 55022:2006 (Class B)
• EN 55024:1998 +A1:2001 +A2:2003 • EN 300 386 V1.3.3 (Class B, other than telecommunications centres criteria) • EN 60950-1:2001 +A11:2004 • EN 60825-1:2001 • EN 60825-2:2004
The product bears the CE mark as illustrated in figures on page14. A signed Declaration of Conformity is available upon request. Brazil The EARU 1112 conforms with the requirements of Anatel Resolution Number 442:2006 (EMC) for a Class B product and Anatel Resolution NR 238:2000 for product safety. Japan  (English translation) This is a Class B product based on the standard of the Voluntary Control Council for Interference from Information Technology Equipment (VCCI). If this is used near a radio or television receiver in a domestic environment, it may cause radio interference. Install and use the equipment according to the instruction manual. Australia / New Zealand The EARU 1112 complies with EN 55022:2006 (Class B) and EN 300 386 V1.3.3 (Class B) in respect of the EMC regulatory arrangements of the Radiocommunications Act 1992 of the Australian Communications And Media Authority, in particular, the Radiocommunications Labelling (Electromagnetic Compatibility) Notice 2008, and of the New Zealand Ministry of Economic Development. The product bears the C-tick mark as illustrated in figures on page14. A signed Declaration of Conformity is available upon request. Regulatory labels (Safety and EMC) The following labels have been placed on the system and various field replaceable units (FRU). The main product-level regulatory label is located on the rear side of the EARU 1112 . See page14. The label bears the product name, power ratings information, certification and other regulatory marks and informational disclosures required by jurisdictional authorities. After reading through this User’s Manual, please keep it handy for easy reference.
About EARU 1112   Thank you for selecting LG-Ericsson EARU 1112. This product will allow you to use the different services available from your provider.  Names and functions of each part Front view         Front LED functions   Indicator Color Function Power  Green  Is lit when the device is powered. Alarm  Red  Is lit when the device is disconnected from the service provider’s network. Data   Green Is lit when the device sends/receives data to/from equipment of the service provider.  Power  Alarm  Data
Rear view       Rear port functions  Indicator Color Function Power (DC 12V,1A) Power This is the port for the power adapter. Optical port For connection to the optical cable This port (optical) is the access point to the service providers network Ethernet port (1 to 4) For connection to Ethernet These ports are Ethernet ports that will connect to user devices supporting 10/100 Mbps.  Rear Ethernet port LED functions  Port  Indicator  Color Function Data LED Green Is lit when the device sends/receives data to/ from user devices. 1-4 Link LED Orange Is lit when the device has Ethernet connected at 100Mbps speed.  Power(12V) Optical port  Ethernet port 1~4
Bottom view    2 1 5 3 4 Number item Label Location 1 PEC & SN Label   9.652mm x 27.94mm   Rear 2 CLEI Label 9.652mm x 27.94mm   Rear 3 LG-Ericsson Barcode   6.5mm x 35mm   Rear 4 Hazard level 1 (per IEC 60825-2) 9.5mm x 15mm  Front 5 Regulatory 40mm x 81mm  Rear
Specifications of EARU 1112  Item Label Dimensions in mm 203(w) x 150(d) x 35(h) Power DC 12V, 1A Ambient Temperature 0℃  to 50℃ Humidity 20% to 80% Technical standards EN 300 386 (Class B, other then Telecom Centres) FCC part 15 (CFR 47) (Class B) EN 55022 (Class B) / 55024 Data rate  100Mbps Connectors  SC/APC (optical), RJ45 (Ethernet) LED indicators  Power, Alarm, Data
Checking package contents Before installing this product, ensure all parts are provided. Checking what is in the package Check the package to make sure the following items are included.                                                         If there is anything missing, please contact your Service provider.  Note Use the power adapter provided with the product. Using another power supply (adapter) can damage the product. Damage from another adapter is not covered under the warranty and repairs would be at the owners expense.     Main body of EARU 1112 C clamps for EARU 1112 Cradle for EARU 1112 Dedicated adator Power cable User Manual of EARU 1112
Installing EARU 1112 This section provides the specifications for EARU 1112 installation, it also describes how to install it and connect it into a network. Installation environments Install the EARU 1112 in an environment where the following specifications are met. - Operating temperature: 0℃ to 50℃ - Relative humidity: 20% to 80% - Power consumption: 6 Watts (Max 8 Watts) - Input voltage: 12V DC Power, 1A  Preparing for installation  Before you install the EARU 1112 , review following information.  Item  Quantity   Supplied Main body of EARU 1112 1 yes C clamps for EARU 1112 2 yes Cradle for EARU 1112 1 yes Ethernet (RJ-45) cable for network access as required    no Power cable  1  yes Dedicated adapter 1 yes Optical fi ber(SC/APC) 1 no
Installing the product This section describes how to: 1. Select a resting mode 2. Connect power cable 3. Connect optical cables 4. Connect Ethernet cables (RJ45) 5. Turn on the power of EARU 1112 6. Check the connection status Let’s see detailed descriptions on each step. Select a resting mode Select a resting mode between horizental mode and vertical mode according to the place where the EARU 1112 is installed.  Horizontal Mode Assemble the main body of EARU 1112 and C clamps with the non-slip strips are facing down.     Vertacal Mode Connect the C clamps on the EARU 1112 as shown above. Insert the EARU 1112 into the cradle. The LG-Ericsson logo should be at the bottom in the cradle.
Connecting optical cable Check that the power switch on the EARU 1112 is in the off position. Insert the green APC connector, into the optical port of the EARU 1112. Insert the other end of the APC optical cable into the optical outlet on your wall.    Only green colored APC connector should be used. Other connector   Types will not work properly.  Connecting Ethernet cable Connect Ethernet cables to the RJ45 Ethernet port numbered 1 to 4 in EARU 1112 (WDM-PON ONT Indoor). Connect the other side of the Ethernet cable to the Ethernet port of your home device.      Connecting power cable & checking the power status Make sure that both ends of the optical cable and the Ethernet cables are installed. And insert the connector of adapter, into the port of the EARU 1112. Make sure that the PWR LED (green) turns on.     Do not pull on the power cable or adapter. This can cause failure or damage to the EARU 1112.
Checking the connection status Checking the connection status of service provider line (Link) When the EARU 1112 is first powered on, the Alarm LED should turn red momentarily. Once communication is established this LED turns off. The Data LED should turn blue and blink.   Checking the connection status of user devices When EARU 1112 is power-fed, the Green and Orange LEDs should be on .The green LED is the data indicator. It blinks when data is being transmitted or received. The orange LED is the link indicator. It lights up with a 100Mbps connection. If there is a 10Mbps connection (a 10BaseT connection), the orange LED is off.
 Setting EARU 1112 When you select to receive WDM-PON service, you do not have to make additional settings on the product to use it. Using Internet With a web browser such as the Internet Explorer on your PC, you can surf freely through the Internet.    Note EARU 1112 does not require any access programs such as ACEMAN_Pro, Enternet 300 and WinPoET; you can directly access the Internet.
Open Source Software Notice  The following GPL software used in this product are subject to the GPL License Agreements.  GPL Software GPL Software ▪ uBoot ▪ Linux kernel ▪ Busybox ▪ sysstat ▪ procps ▪ gdb ▪ Rstp  LGPL Library ▪ libSegFault ▪ libmemusage ▪ libanl ▪ libc ▪ libcrypt ▪ libdl ▪ libm ▪ libncurses ▪ libnsl ▪ libnss ▪ libpthread ▪ librt ▪ libutil LG-Ericsson offers to provide source codes and copies of the GPL licenses to you on CD-ROM for a charge covering the cost of performing such distribution, such as the cost of media, shipping and handling upon e-mail request to LG-Ericsson at : opensource@lgericsson.com  This offer is valid for a period of three (3) years from the date of the distribution of this product by LG-Ericsson.