Ericsson LG LSP400 CDMA Fixed Wireless Terminal User Manual

Ericsson-LG Co., Ltd. CDMA Fixed Wireless Terminal

User manual

3      CDMA Fixed Wireless Phone   User Guide      Model: LSP-400                        Please read this manual carefully before operating your set. Retain it for future reference.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 2 REVISED HISTORY   DATE    VERSION    CONTENTS OF CHANGES  REMARK   2005/05    1.0    Initial Release     2009/03  1.1  Change Company Logo
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 3 Highlights Congratulations on your subscription to the LSP-400 Fixed Wireless Phone. This phone has been designed to operate on the latest digital mobile communications technology CDMA 2000 1x. It has greatly enhanced voice clarity and provides various advanced features.  Key phone features:   ¡  3-line LCD Display with status indicator   ¡  12 Polyphonic sound   ¡  Ring tones: Choose from 15 melodies   ¡  Large Phone Book with 300 entries   ¡  Speed Dialling for upto 300 numbers   ¡  3 Way call conferencing   ¡  50 messages can be stored in INBOX and OUTBOX   ¡  50 numbers call history   ¡  Last number redial   ¡  Hands free Speaker Phone   ¡  Receiver Off-Hook tone   ¡  Adjustable Ring volume, Key volume, Earpiece volume   ¡  Fast charging battery
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 4 CONTENTS   1. IMPORTANT INFORMATION ............................................................................ 5 1.1 SAFETY INSTRUCTION ..............................................................................................................5 1.2 OPTIMAL PHONE PERFORMANCE ..............................................................................................5 1.3 CARE AND SERVICE .................................................................................................................6 1.4 SAFETY INFORMATION ..............................................................................................................7 2. INTRODUCTION ............................................................................................. 10 2.1 FRONT VIEW OF THE PHONE ................................................................................................... 10 2.2 LCD DISPLAY ....................................................................................................................... 11 2.3 INSTALLATION........................................................................................................................ 12 2.4 INSTALLATION STEPS ............................................................................................................. 15 3. BASIC OPERATIONS ..................................................................................... 16 3.1 MAKING A CALL ..................................................................................................................... 16 3.2 3 WAY CALL CONFERENCING ................................................................................................... 16 3.3 CALL WAIT ........................................................................................................................... 16 3.4 VOLUME CONTROL ................................................................................................................ 17 3.5 RECEIVING A CALL ................................................................................................................ 17 3.6 IN CALL MEMO ...................................................................................................................... 17 3.7 LOCK MODE ......................................................................................................................... 18 4. MENU TREE.................................................................................................... 19 4.1 MENU ................................................................................................................................. 21 4.2 MESSAGE .......................................................................................................................... 32 4.3 FIND ................................................................................................................................... 37 5. SPEAKER PHONE .......................................................................................... 41 6. TROUBLESHOOTING .................................................................................... 42 7. GENERAL INFORMATION ............................................................................. 43 7.1 MAIN UNIT ............................................................................................................................ 43 7.2 AC/DC ADAPTER .................................................................................................................. 43 7.3 BATTERY .............................................................................................................................. 43 APPENDIX FCC RF EXPOSURE INFORMATION 오류!  책갈피가 정의되어 있지 않습니다.44
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 5 1.  Important Information   1.1  Safety Instruction   WARNING / CAUTION   To reduce the risk of fire or electric shock, do not expose this unit to rain or moisture. Do not use this unit in swimming pools or other water bodies. 1.2  Optimal Phone Performance     Do not hold the antenna when operating the unit, or operate the unit when someone is  within  four  inches  (ten  centimeters)  of  the  antenna.  Both  cases  affect  the  call quality and may cause the phone to operate at a higher power level than required.     For the best  call quality, keep the antenna free from  obstructions and position the antenna upright.     Do  not  use  the  unit  if  the  antenna  is  damaged.  Replace  the  damaged  antenna immediately by a qualified technician. Use only a manufacturer-approved antenna.   Non-approved  antennas,  modifications  or  attachments  may  impair  call  quality  and damage the unit.   RF  energy  may  affect  improperly  installed  or  inadequately  shielded  personal medical  devices  such  as  pace-makers  or  hospital  monitors.  Consult  the manufacturer  of  any  personal  medical  devices  to  determine  whether  they  are adequately  shielded  from  external  RF  energy.  Turn  your  unit  OFF  in  health  care centers  if  any  regulations  posted  in  the  area  instruct  you  to  do  so.  Hospitals  or health care centers may be using equipment that may be sensitive to external RF energy.     If this unit causes harmful interference to radio or television reception, which can be determined by  turning the  equipment off  and on,  the  user  is  encouraged  to  try  to correct the interference by one or more of the following measures:   Ø  Reorient or relocate the receiving antenna   Ø  Place the radio or television farther away from the unit.   Ø  Connect the equipment to an outlet on a circuit different from that to which the unit is presently connected.   Ø  Consult  the Authorized  LG-NORTEL  Dealer for assistance  of  an  experienced radio/TV technician.     Use battery, antenna and AC power supply provided by LG-NORTEL. Using spares made by any other manufactures may invalidate the warranty.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 6   Only  authorized  personnel  should  service  the  unit  and  its  accessories.  Faulty installation or service can be dangerous and may invalidate the warranty.     Do not use the unit in any designated “no cellular phone use” area.     Avoid using the unit in high temperature or humidity.     Avoid  spilling  any  liquid  on  the  unit.  If  the  unit  gets  wet,  turn  the  power  off immediately  and  remove  the  backup  battery  and  AC  power  supply.  If  the  unit doesn’t work, please contact the service provider immediately.     Avoid shock or impact.     We  recommend  you  to  charge  the  backup  battery  before  initial  use.  The  backup battery may be discharged during delivery.  1.3  Care and Service   Before cleaning, always unplug the unit from the wall outlet and remove the antenna (or disconnect the antenna cable). Do not use liquid or aerosol cleaners; use a damp cloth for cleaning.   If the unit doesn’t work, do not attempt to disassemble it; contact the phone service agent for assistance.   If any of the following conditions exist, unplug the unit from the wall plug, remove the battery and call the qualified engineer.     The power supply cord is damaged or frayed.     Liquid has spilled into the unit.     The unit has been exposed to rain or water.    The unit has been dropped or damaged.     The unit does not function normally even after following the operating instructions.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 7 1.4  Safety Information   WARNING   ¡  For safety, use only an adapter approved by LG.   LG does not bear responsibility for any faults that  may arise due to non- conformation to this guide.   Example: LSP-400 (LG Power Adapter Source: DC 5V / 1A)    ¡  Do not, in any way, cause a short-circuit. It may start a fire or the unit may explode causing injury.      ¡  Do not create a sudden impact on the battery by throwing it. Do not dispose off batteries by putting them in a fire. They may explode or catch fire due to the electrolyte within.  CAUTION   ¡ Do  not  use the  unit  with  a  car battery.  It may cause  electric shock, fire, breakdown or transformation.      ¡ Avoid  using  the  unit  in  high  temperature  or  humidity.  Avoid  spilling any  liquid  on this unit.  If  the  unit  gets wet,  turn  off  immediately  AC power supply.     ¡ Keep the unit dry. Submersion, humidity, and liquids contain minerals that may corrode internal electronic circuits. !
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 8  ¡  Do  not  store  or  use  the  unit  in  dusty  or  dirty  areas  as  this  can damage the moving parts.    ¡ Do not store the unit in hot areas. High temperatures can shorten the life of electronic devices, damage batteries, and warp or melt certain plastics.  ¡ Do  not  store  the  unit  in  cold  areas.  When  the  unit  warms  upto  its normal  operating  temperature,  moisture  can  form  inside  the  unit, which can damage the internal electronic circuit boards.    ¡ Do  not  attempt  to open  it.  Non-expert  handling  of  the  device  could damage it. It may cause fire, electric shock and breakdown. Consult your authorized LG dealer for assistance.     ¡ Do not drop, knock or shake the unit. Rough handling may break the internal circuit boards.     ¡ Do not use harsh chemicals, cleaning solvents or strong detergents to  clean  the  unit.  Wipe  it  with  a  soft  cloth  that  has  been  slightly dampened in a mild soap and water solution.    ¡ Do  not paint the  unit. Paint can  clog the device’s moving  parts and prevent proper functioning.   ¡ During  lightning,  do  not  touch  the  power  plug  or  the  phone  line.  It may result in an electric shock or death.     ¡ Do not install the unit under direct sunlight or on an uneven surface.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 9  ¡ Before using the plug, check the available power voltage. Inaccurate power voltage may cause fire and damage.   Example: LSP-400 Input Voltage: 100 ~ 240V.    ¡ Do  not plug  many power cords into one outlet. It  may  cause fire or electric shock.     ¡ Do not remodel the power cord or disassemble it. If the power cord or plug is impaired, do not use it. It may cause fire or electric shock     ¡ Do not install the unit in an ill-ventilated place. It may cause fire or a breakdown.     ¡ Do  not  touch  the  plug  with  wet  hands.  When  disconnecting  the power  cord of any accessory, grasp  and pull out the plug itself and not the cord. It may cause fire or electric shock.    ¡ Do not put heavy objects on the power cord. Do not bend the power cord too much. It may cause fire or electric shock     ¡ Use  only  an  LG-approved battery  and adapter.  If  not,  it  may  cause an  explosion  or  result  in  a  short-circuit.  LG  does  not  bear  any responsibility for the damage.    ¡ When  you  disconnect  the  power  cord  of  any  accessory,  grasp  and pull  the  plug  itself  and  not  the  cord.  It  may  cause  the  adapter  to breakdown.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 10 2.  Introduction   2.1  Front View of the Phone     ①  Soft key 1: Activates MAIN MENU state   ②  Message: Activates SMS MENU state   ③  END/PWR: Escape from the any MENU state, Power ON / OFF   ④  Soft key 2: Activates FIND MENU state   ⑤  (q): Moves down in the MENU or Volume DOWN   ⑥  (p): Moves up in the MENU or Volume UP   ⑦  Clear: Deletes the last digit / Moves previous MENU   ⑧  Dial/Flash: Activates Dial or Flash state, View Call History   ⑨  Activates hands free speaker phone function   ⑩  MIC: Microphone for hands free speaker phone function   ⑪  Attached Antenna
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 11 2.2  LCD Display   The LCD shows icons on the top of the LCD screen. Different indicators appear based on the phone's operating mode.    LED    Operating Condition    RSSI indicator: Indicates the signal strength in the service area.    No service: The phone is not receiving any system signal.    In use: Displayed when a call is in progress or the phone is in off-hook and dial tone is heard.    Text message: Displayed when a text message is received.    Voice message: Displayed when a voice message is received.    Alarm: Displayed when alarm time is set.    Caller ID: Displayed when caller ID is received.    Not used    Battery charge level: Indicates charged battery level.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 12 2.3  Installation   You should follow each step carefully as shown below in order to guarantee the proper operation of CDMA Fixed Wireless Phone.                                   Main Unit   Dipole Antenna   AC/DC Power Adapter   User Guide
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 13 STEP I. Check Components ¡ The following components are supplied Fixed Wireless Phone.   1.  LSP-400 Main Unit with Handset (Including inner backup battery) -1EA-   2.  Dipole Antenna -1EA-   3.  AC/DC Power Adapter -1EA-   4.  User Guide -1EA-   ¡ Please make sure that these components are present before you begin to install the unit.  If  any  of  the  components  are  missing  or  damaged,  contact  your  service provider immediately.   STEP II. Place the Terminal   ¡ Place  the  unit  on  the  stable  flat  surface  area  (desk,  table,  etc.).  Serious  damage may result if the unit is dropped. Do not place the unit within 1 meter of heaters or radiators.   This  unit  is  designed for desktop  usage.  Avoid the  direct exposure to  sunlight  and dampness.   ¡ Read the SAFETY INFORMATION located in the first part of this document before you place the unit.   STEP III. Connect Components (Please refer to “Installation Steps” in 2.4)   ¡ Connect the antenna to the TNC antenna connector located at the top of the unit. If you have placed the unit on a flat surface, position the antenna upright.   ¡ Connect the curl cord of the handset to the RJ-11 port located on the left side of the unit.   ¡ Connect the AC/DC Adapter cable to the DC input port located at the top of the unit.   ¡ If it is correct, a beep tone will be heard.   ¡ If  it  is  not  correct  (Booting  fails  or  beep  tone  is  not  heard),  you  will  have  to reconnect the adapter or reset the battery switch to “on”.   ¡ Please observe the following to get better voice quality   1.  Keep away from electrical appliances such as TV, computer, radio etc.   2.  Keep the unit in a high and central location without any obstructions.   3.  Raise the integral antenna of the unit to get maximum strength as shown in the figure.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 14   STEP IV. Check the LCD Display   ¡ After you follow the installation instruction step I to step III, please check the LCD for normal operation.   ¡ If you do not see the status of service, please repeat the 4th instruction of step III.   Then confirm the status of phone to get the proper signal strength from the service operator system.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 15 2.4  Installation Steps   Please follow the procedure below to install the unit properly.   Connect base-handset to the handset connector.  Connect the antenna to the TNC connector (Turn right).  Turn the antenna upright.  When you first use the unit, please Turn “on” the battery switch.  Connect the AC power supply.  Press END/PWR button to operate initially.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 16 3.  Basic Operations   3.1  Making a Call   You can make a call as follows.   1.  Pick up the handset or press X button.   2.  Listen for dial tone.   3.  Enter the phone number with area code if needed.   4.  Wait for the Auto Time-out.   5.  The call is connected and you may start conversation.   6.  To disconnect the call, replace the handset or press X button.   When the user presses the Dial/Flash button after dialing any desired number, if the user picks up the handset or presses the Speaker Phone button, the phone makes a call immediately.  3.2  3 way call conferencing   You can start tripartite conversation.   1.  Enter  the  phone  number  of  the  2nd  party  phone  while  you  are  in  telephonic conversation with 1st party.   2.  Press Dial/Flash button.   This service should be provided by your service provider.  3.3  Call Wait   While a call is in progress, you may hear two beeps indicating another incoming call. When call wait is enabled, you may put the active call on hold while you answer the other incoming call.   1.  Press Clear or END/PWR button, Call Wait window then disappears.   2.  Press Dial/Flash button, you may start conversation with called number.   3.  Re-press Dial/Flash button, you may start conversation with previous number.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 17 3.4  Volume Control   1.  Press UP/DOWN button of navigation while in a call, to adjust earpiece volume.   2.  Press Soft Key 2 [MUTE] to Prevent sound from your end during the call. To cancel Mute, Press again Soft Key 2 [UNMUTE].  To scroll in MENU, press ▲ or ▼ button. 3.  Press Soft Key 1 [MENU] + 3(MIC LEVEL) during a call and select Low or High by pressing Soft Key 2 [NEXT] or Press UP/DOWN button, to adjust MIC volume.     3.5  Receiving a Call   When the bell rings in idle state, you can receive a call as follows   1.  Pick up the handset or press the Speaker Phone button.   2.  Start a conversation.   3.  To disconnect the call, replace the handset or press the Speaker Phone button.  3.6  In Call Memo   Allow you to store number during the call.   To store number:   1. Press Soft Key 1 [MENU] + 1(MEMO).   2. Enter upto 32 numbers using the keypad.   3. Press Soft Key 1 [ADD] to save.  To retrieve an In Call Memo:   1. Press Dial/Flesh button to see saved number.   Note: You can store the number by pressing Soft Key 1 [ADD].
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 18 3.7  Lock Mode   Protects your phone from unauthorized use. Once the phone is locked, it is in restricted mode, until the in lock code is entered. This will allow you to receive phone calls and still make emergency calls. The lock code/password on your phone is “0000” by default. Also you can modify your lock code as explained [See 4.1.4.6 page no. 31]. You can lock your phone using the ‘#’(Ï:Lock) key, also you can lock your phone manually as explained [See 4.1.4.1 page no. 28].  Under Lock Mode  1.  Press ‘#’ button for some time.   The phone is now locked.   2.  To unlock, press Soft Key 1 [UNLOCK].    3.  Enter 4 digits lock code/password. (Default “0000”).
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 19 4.  Menu Tree   Main MENU   Sub-MENU   Setting Value   1. MENU   1. SOUND    1. RING TYPE    Bengali / Disco / Filmi / Goan / Gujrati Folk /   Happybday / Malyalam / Marathi pohada /   OmJaiJagdish / Pahadi / Polka / Punjabi /   SareJahanSe / Shiridivaasa / VandeMataram  2. RING VOLUME    4 steps   3. KEY VOLUME    5 steps (including silent step)   4. EAR VOLUME    4 steps   2. SETTINGS    1. ALARM    SET TIME / SET RINGER   2. CALL    CALL FORWARD / CALL WAIT   3. CONNECT ALERT    Enable / Disable   4. MY NUMBER    OK / EDIT   5. VIEW VERSION    OK / MORE   3. DIAL FEATURES  1. HOT LINE    Enable / Disable   2. HOT LINE TIME    2-9 sec.   3. AUTO TIME-OUT    2-9 sec.   4. SPEED DIALING    Enable / Disable   5. DTMF LENGTH    Short / Long   4. SECURITY    1. SET LOCK MODE    Enable / Disable   2. CLEAR CALLS    No / Yes   3. CLEAR MEMORY    No / Yes   4. EMERGENCY CALL    3 Options   5. RESTRICT CALL    SET RESTRICT / WHITE LIST / BLACK LIST  6. NEW CODE    -
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 20  2. MESSAGE   1. WRITE    1. NEW MESSAGE    OK / FIND   2. EDIT OUTBOX    EDIT / ERASE   3. EDIT INBOX    EDIT   4. CLEAR OUTBOX    No / Yes   2. INBOX    1. TEXT MSG    VIEW / ERASE   2. VOICE MSG    REPLY / ERASE   3. CLEAR ALL    No / Yes   3. MSG ALERT    -    Off / Once / Every 2 Min   4. MSG RINGER    -    Sms alarm 1 ~ 5   5. SETTINGS    1. DEFER DDELIVERY  Immediate / After 30 Min. / After 1 Hour /   After 2 Hours / After 12 Hours / After 1 Day /   After 2 Days   2. VALID PERIOD    Default / 30 Minutes / 1 Hour / 2 Hours /   12 Hours / 1 Day / 2 Days   3. AUTO DEL.INBOX    Disable / Enable   3. FIND   1. CALL HISTORY    1. ALL CALL    VIEW / ERASE   2. MISSED    VIEW / ERASE   3. RECEIVED    VIEW / ERASE   4. DIALLED    VIEW / ERASE   5. MEMO    VIEW / ERASE   6. ERASE HISTORY    ERASE  ALL  CALL  /  ERASE  MISSED  / ERASE  RECEIVED  /  ERASE  DIALLED  / ERASE MEMO   2. PHONE BOOK    1. BY NAME    FIND / ABC   2. BY ADDRESS    FIND   3. BY NUMBER    FIND
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 21 4.1  MENU   You may select from four MAIN MEMU (SOUND, SETTINGS, DIAL FEATURES, SECURITY) for this item.   If you press Soft Key 1 MENU is activated.    To scroll in MENU, press ▲ or ▼ button.   To return to the initial screen, press END/PWR button and to return to the previous screen, press Clear button.  4.1.1  SOUND   Allows you to set various volumes settings and Ring Type.   Press Soft Key 1 MENU + 1(SOUND) in on-hook state.    RING TYPE   You can select the various ring types. 1.  Press Soft Key 1 MENU + 1(SOUND) + 1(RING TYPE) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT] to select desired ring type.   3.  Press Soft Key 1 [OK] to save setting.  Note: Choose from 15 different ring types (Bengali, Disco, Filmi, Goan, Gujrati Folk, Happybday, Malyalam, Marathi pohada, OmJaiJagdish, Pahadi, Polka, Punjabi, Sare JahanSe, Shiridivaasa, and VandeMataram).
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 22 RING VOLUME You can adjust the ringing volume level of incoming call alert.   1.  Press Soft Key 1 MENU + 1(SOUND) + 2(RING VOLUME) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT]   to adjust Ring Volume.   3.  Press Soft Key 1 [OK] to save setting  KEY VOLUME The tone when you press a key can be adjusted. 1.  Press Soft Key 1 MENU + 1(SOUND) + 3(KEY VOLUME) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT]   to adjust key volume.   3.  Press Soft Key 1 [OK] to save setting.  4.1.1.4 EAR VOLUME   The voice of the other party can be adjusted.   1.  Press Soft Key 1 MENU + 1(SOUND) + 4(EAR VOLUME) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT]   to adjust earpiece volume.   3.  Press Soft Key 1 [OK] to save setting.    Note: Press UP/DOWN button to adjust the volume during a conversation.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 23 4.1.2  SETTINGS You can use additional features like Alarm, CALL, Connect Alert, My Number etc.   Press Soft Key 1 MENU + 2(SETTINGS) in on-hook state.    ALARM [SET TIME]   This function allows you to set alarm time.   1.  Press Soft Key 1 MENU + 2(SETTINGS) + 1(ALARM) + 1(SET TIME) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT] to select from Off, Once or Always and press Soft Key 1 [OK].   3.  Enter alarm time and press Soft Key 1 [AM/PM] and select AM or PM.   4.  If you want to modify the time, press Clear button and reset.   5.  Press Soft Key 1 [OK] to save and exit.  [SET RINGER]   This function allows you to select ringer for alarm alert.   1.  Press Soft Key 1 MENU + 2(SETTINGS) + 1(ALARM) + 2(SET RINGER) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT] to select from Alarm ring 1, Alarm ring 2, Alarm ring   3, Alarm ring 4 or Alarm ring 5.   3.  Press Soft Key 1 [OK] to save and exit.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 24 CALL   [CALL FORWARD]   This function allows you to forward your incoming calls to another number.   1.  Press Soft Key 1 MENU + 2(SETTINGS) + 2(CALL) + 1(CALL FORWARD) in on-hook state.   2.  Select from IMMEDIATE, WHEN BUSY, NO REPLY or DISABLE ALL options by pressing number button.   3.  Select ENABLE or DISABLE.   F  If you select ENABLE, Enter the phone number that you want. Press Soft Key 1 [OK] to save and exit.   4.  To modify the prefix number, select VIEW EN-CODE, VIEW DIS-CODE or VIEW CODE and press Soft Key 2 [EDIT].   5.  Enter the prefix number, and press Soft Key 1 [OK] to save and exit.   F  You would need to call “121” to get this service activated.  [CALL WAIT]   While a call is in progress, you may hear two beeps indicating another incoming call. When call wait is enabled, you can put the active call on hold while you answer the other incoming call.   1.  Press Soft Key 1 MENU + 2(SETTINGS) + 2(CALL) + 2(CALL WAIT) in on-hook state.   2.  Select ENABLE or DISABLE.   3.  To modify the prefix number, select VIEW EN-CODE or VIEW DIS-CODE and press Soft Key 2 [EDIT]   4.  Enter the prefix number, and press Soft Key 1 [OK] to save and exit.   F  You would need to call “121” to get this service activated.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 25 CONNECT ALERT   This function allows you to select the call connect tone.   1.  Press Soft Key 1 MENU + 2(SETTINGS) + 3(CONNECT ALERT) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT] to select Enable or Disable.   3.  Press Soft Key 1 [OK] to save and exit.   MY NUMBER   You can confirm your phone number. 1.  Press Soft Key 1 MENU + 2(SETTINGS) + 4(MY NUNBER) in on-hook state.   2.  Press Soft Key 1 [OK] to exit.   Note: To modify your phone number, press Soft Key 2 [EDIT]. Enter the phone number, and press Soft Key 1 [OK] to save and exit.   VIEW VERSION   You can confirm your phone S/W version.   1.  Press Soft Key 1 MENU + 2(SETTINGS) + 5(VIEW VERSION) in on-hook state.   2.  To confirm next page, press Soft Key 2 [MORE], and press Soft Key 1 [OK] to exit.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 26 4.1.3  DIAL FEATURES   Press Soft Key 1 MENU + 3(DIAL FEATURES) in on-hook state.   HOT LINE   1.  Press Soft Key 1 MENU + 3(DIAL FEATURES) + 1(HOT LINE) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT]   to select Enable or Disable and Press Soft Key 1 [OK]   3.  Press Soft Key 2 [EDIT] and enter the Hot Line phone number.   4.  Press Soft Key 1 [OK] to save and exit.  HOT LINE TIME   1.  Press Soft Key 1 MENU + 3(DIAL FEATURES) + 2(HOT LINE TIME) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT] to select hot line connection time (2~9 sec.).   3.  Press Soft Key 1 [OK] to select.  AUTO TIME-OUT   Setting the length of time the phone waits before automatically dialing a number. You can select this duration to be between 2 and 9 seconds.   1.  Press Soft Key 1 MENU + 3(DIAL FEATURES) + 3(AUTO TIME-OUT) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT] to select Auto Time-out between 2 and 9 sec.   3.  Press Soft Key 1 [OK] to select.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 27 SPEED DIALING   This function allows you to make a call faster by just pressing a corresponding number. Upto 300 memory locations can be assigned for speed dial. To speed dialing press the memory number (1 through 300) corresponding to the appropriate memory location and hold for a few seconds.   F This function can be used when the speed dialing is set to enable.   1.  Press Soft Key 1 MENU + 3(DIAL FEATURES) + 4(SPEED DIALING) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT] to select Enable or Disable.   3.  Press Soft Key 1 [OK] to save and exit.   4.1.3.5 DTMF LENGTH   This function allows you to the setting of Key beep playback length. Possible settings are Short and Long. 1.  Press Soft Key 1 MENU + 3(DIAL FEATURES) + 5(DTMF LENGTH) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT] to select Short or Long.   3.  Press Soft Key 1 [OK] to select.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 28 4.1.4  SECURITY   4.1.4.1 SET LOCK MODE   This function prevents the usage of your phone without your permission. You can protect your phone by 4 digits lock code/password. Possible settings are Enable or Disable.   Disable indicates that the phone is not locked.   Enable sets the phone locks immediately.   1.  Press Soft Key 1 MENU + 4(SECURITY).   2.  Enter 4 digits lock code/password.   3.  Press 1(SET LOCK MODE).   4.  Press UP/DOWN button or Soft Key 2 [NEXT] to select Enable or Disable.   5.  Press Soft Key 1 [OK] to save and exit.   F  Default lock code/password is “0000”.     4.1.4.2 CLEAR CALLS   This function allows you to erase complete call history of previous outgoing and incoming calls. 1.  Press Soft Key 1 MENU + 4(SECURITY).   2.  Enter 4 digits lock code/password.   3.  Press 2(CLEAR CALLS).   4.  Press UP/DOWN button or Soft Key 2 [NEXT] to Select Yes or No.   5.  Press Soft Key 1 [OK] to exit.   Note: Deleted call history can not be retrieve.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 29 CLEAR MEMORY   This function allows you to erase complete phone book memory.   1.  Press Soft Key 1 MENU + 4(SECURITY). 2.  Enter 4 digits lock code/password.   3.  Press 3(CLEAR MEMORY).   4.  Press UP/DOWN button or Soft Key 2 [NEXT] to select Yes or No.   5.  Press Soft Key 1 [OK] to exit.   Note: Deleted phone book memory can not be retrieve.  EMERGENCY CALL   This function allows you to enter 3 emergency numbers. You can call these default emergency numbers 100, 101, 102 even when the phone is locked or restricted. 1.  Press Soft Key 1 MENU + 4(SECURITY).   2.  Enter 4 digits lock code/password.   3.  Press 4(EMERGENCY CALL).   4.  Press UP/DOWN button or Soft Key 2 [NEXT] to edit numbers.   5.  Press [OK] to save the number and press Clear or END/PWR to exit.   F  This service should be provided by your service provider.  RESTRICT CALL   This function allows you to restrict your outgoing calls including numbers / numbers beginning with specified digit in the BLACK LIST. For example: if “9” is stored in the BLACK LIST, all number beginning with “9” cannot be called. However if “92” is stored in WHITE LIST, you can the call numbers beginning with “92” successfully.  [SET RESTRICT] You can choose following options:   F No restriction   This function allows you to disable all restrictions.   F Restriction   This function allows you to enable restrictions.   F Emergency only   This function allows you to set phone, enable for only emergency numbers.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 30 1.  Press Soft Key 1 MENU + 4(SECURITY).   2.  Enter 4 digits lock code/password.   3.  Press 5(RESTRICT CALL) + 1(SET RESTRICT).   4.  Press UP/DOWN button or Soft Key 2 [NEXT]   to select from No restriction, Restriction or Emergency Only.   5.  Press Soft Key 1 [OK] to exit.  [WHITE LIST]   The numbers placed the WHITE LIST would be given a priority. You can save upto 10 numbers in WHITE LIST.   This function can be used when the SET RESTRICT is set to Restriction. 1.  Press Soft Key 1 MENU + 4(SECURITY).   2.  Enter 4 digits lock code/password.   3.  Press 5(RESTRICT CALL) + 2(WHITE LIST).   4.  Press UP/DOWN button or Soft Key 2 [NEXT] to select from option 1 to 10.   5.  Press Soft Key 1 [EDIT] and enter the permit phone number.   6.  Press Soft Key 1 [OK] to save and press Clear button to exit.   [BLACK LIST]   You cannot call any phone numbers saved in BLACK LIST. You can save upto 10 numbers in BLACK LIST.   This function can be used when the SET RESTRICT is set to Restriction. 1.  Press Soft Key 1 MENU + 4(SECURITY).   2.  Enter 4 digits lock code/password.   3.  Press 5(RESTRICT CALL) + 3(BLACK LIST).   4.  Press UP/DOWN button or Soft Key 2 [NEXT]   to select from option 1 to 10.   5.  Press Soft Key 1 [EDIT] and enter the deny phone number.   6.  Press Soft Key 1 [OK] to save and press Clear button to exit.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 31 NEW CODE   This function allows you to modify your lock code/password. 1.  Press Soft Key 1 MENU + 4(SECURITY).   2.  Enter 4 digits lock code/password.   3.  Press 6(NEW CODE).   4.  Enter the new 4 digits lock code that you want.   5.  Press Soft Key 1 [OK] to go next edit state.   6.  Enter the new lock code again.   7.  Press Soft Key 1 [OK] to save and press Clear or Soft Key 2 [BACK] button to exit
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 32 4.2  MESSAGE   This function allows you to facility of Short Messaging. Text messaging, page and voice mailbox become available as soon as the phone is switched on. The phone can store upto 50 messages each in INBOX and OUTBOX. If you press Message Key, SMS MENU is activated.      To scroll in SMS MENU, press ▲ or ▼ button.   At any point of time, to return to the initial screen, press END/ PWR button and to return to the previous screen, press Clear button.    4.2.1 WRITE   This function allows you to compose and send SMS.   NEW MESSAGE   1.  Press Message + 1(WRITE) + 1(NEW MESSAGE) in on-hook state.   2.  Enter phone number manually or press [FIND]   to search from phone book or call history.   3.  Write messages. Press Soft Key 2 [ABC] to change upper, lower case or a specific character.   4.  For DELIVERY ACK option, press UP/DOWN button or Soft Key 2 [NEXT] to select Yes or No.   F  This function allows you to know whether the messages have been successfully transmitted to the recipient.   5.  For STORE MESSAGE option, press UP/DOWN button or Soft Key 2 [NEXT] to select Yes or No. The message will be store in EDIT OUTBOX. 6.  For SET PRIORITY option, press UP/DOWN button or Soft Key 2 [NEXT] to select priority level Normal, Urgent or Emergency.   7.  Press Soft Key 2 [OK] to send message.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 33 EDIT OUTBOX   All your successfully sent messages are saved here.   1.  Press Message + 1(WRITE) + 2(EDIT OUTBOX) in on-hook state.   2.  To erase message, select Soft Key 2 [ERASE].   3.  To view or edit desired message, select Soft Key 1 [EDIT].  EDIT INBOX   All your received messages are saved here.   1.  Press Message + 1(WRITE) + 3(EDIT INBOX) in on-hook state.   2.  To view or edit desired message, select Soft Key 1 [EDIT].  CLEAR OUTBOX   To erase all sending messages, select this function.   1.  Press Message + 1(WRITE) + 4(CLEAR OUTBOX) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT] to select Yes or No.   3.  Press Soft Key 1 [OK] to exit.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 34 4.2.2 INBOX   TEXT MSG   Received messages are stored here.   1.  Press Message + 2(INBOX) + 1(TEXT MSG) in on-hook state.   2.  To view desired message, select Soft Key 1 [VIEW]. 3.  To reply the message, select Soft Key 1 [REPLY].   4.  To erase message, select Soft Key 2 [ERASE].   F  In TEXT MSG, the meaning of (5/37) beside TEXT   MSG is that 5 out of 37 messages are unread.   VOICE MSG   Voice MSG notifications indicate the number of new voice messages in your mailbox.   Only the most recent voice mail notification will be stored in your phone, previous message will be overwritten.   1.  Press Message + 2(INBOX) + 2(VOICE MSG) in on-hook state.   2.  Pick up the handset or press Speaker Phone button to confirm your voice message.  CLEAR ALL   This function allows you to erase all received messages.   1.  Press Message + 2(INBOX) + 3(CLEAR ALL) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT] to select No or Yes.   3.  Press Soft Key 1 [OK] to exit.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 35 4.2.3  MSG ALERT   This function allows you to set the frequency of notification when message is received. 1.  Press Message + 3(MSG ALERT) in on-hook state.   2.  Select Off, Once or Every 2 Min by pressing   UP/DOWN button or Soft Key 2 [NEXT].   3.  Press [OK] to save and exit.   4.2.4  MSG RINGER   This function allows you to set the ring-type for notification when message is received. You can select from 5 choices. 1.  Press Message + 4(MSG RINGER)   in on-hook state.   2.  Select a desired ring type by pressing   UP/DOWN button or Soft Key 2 [NEXT].   3.  Press [OK] to save and exit.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 36 4.2.5  SETTINGS   DEFER DELIVERY   1.  Press Message + 5(SETTINGS) + 1(DEFER DELIVERY) in on-hook state.   2.  Select one of the following by pressing UP/DOWN button or Soft Key 2 [NEXT] :   Immediate After 30 Min. After 1 Hour After 2 Hours   After 12 Hours After 1 Day After 2 Days   3.  Press [OK] to save.  VALID PERIOD 1.  Press Message + 5(SETTINGS) + 2(VALID PERIOD) in on-hook state.   2.  Select desired time by pressing UP/DOWN button or Soft Key 2 [NEXT] :   Default 30 Minutes 1 Hour 2 Hours   12 Hours 1 Day 2 Days   3.  Press [OK] to save.   AUTO DEL.INBOX 1.  Press Message + 5(SETTINGS) + 3(AUTO DEL.INBOX) in on-hook state.   2.  Press UP/DOWN button or Soft Key 2 [NEXT] to select Enable or Disable.   3.  Press [OK] to save.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 37 4.3  FIND   This function allows you to find the phone numbers that you have stored in the phone book memory. You may find the numbers from call history also.   If you press Soft Key 2, FIND is activated.      To return to the initial screen, press END/PWR button and to return to the previous screen, press Clear button. 4.3.1  CALL HISTORY   This function allows you to see last 50 numbers of all types of outgoing and incoming calls.   ALL CALL   [In on-hook state]   1.  Press FIND + 1(CALL HISTORY) + 1(ALL CALL)   or Dial/Flash button.   2.  Press UP/DOWN button to select a number or name   in the call history list.   3.  To view desired item, select Soft Key 1 [VIEW].   4.  To delete desired number, select Soft Key 2 [ERASE].   5.  Press [TIME] to see more information and press [SAVE]   to save the number in the phone book.  [While in a Call]   1.  Press MENU + 2(FIND) + 1(CALL HISTORY) +   1(ALL CALL).   2.  Press UP/DOWN button to select a number or name   in the call history list.   3.  To view desired item, select Soft Key 1 [VIEW].   4.  To delete desired number, select Soft Key 2 [ERASE].   5.  Press [TIME] to see more information and press [SAVE] to save a number in the phone book.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 38 MISSED   1.  Press FIND + 1(CALL HISTORY) + 2(MISSED) in on-hook state.   2.  Press UP/DOWN button to select a number or name in the missed call list.   3.  To view desired item, select Soft Key 1 [VIEW].   4.  To delete missed call, select Soft Key 2 [ERASE].   5.  Press [TIME] to see more information and press [SAVE] to save the number in the phone book.  RECEIVED   1.  Press FIND + 1(CALL HISTORY) + 3(RECEIVED) in on-hook state.   2.  Press UP/DOWN button to select a number or name in the received call list.   3.  To view desired item, select Soft Key 1 [VIEW].   4.  To delete received call, select Soft Key 2 [ERASE].   5.  Press [TIME] to see more information and press [SAVE] to save the number in the phone book.  DIALLED   1.  Press FIND + 1(CALL HISTORY) + 4(DIALLED) in on-hook state.   2.  Press UP/DOWN button to select a number or name in the dialed call list.   3.  To view desired item, select Soft Key 1 [VIEW].   4.  To delete dialed call, select Soft Key 2 [ERASE].   5.  Press [TIME] to see more information and press [SAVE] to save the number in the phone book.  MEMO   1.  Press FIND + 1(CALL HISTORY) + 5(MEMO) in on-hook state.   2.  Press UP/DOWN button to select desired item in the memo list.   3.  To view desired item, select Soft Key 1 [VIEW].   4.  To delete memo, select Soft Key 2 [ERASE].   5.  Press [TIME] to see more information and press [SAVE] to save the number in the phone book.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 39 ERASE HISTORY   1.  Press FIND + 1(CALL HISTORY) + 6(ERASE HISTORY) in on-hook state.   2.  To  delete  all  calls  that  you  want,  select  from  1(ERASE  ALL  CALL),  2(ERASE MISSED),  3(ERASE  RECEIVED),  4(ERASE  DIALLED)  or  5(ERASE  MEMO)  and press Soft Key 2 [NEXT] to select No or Yes.   3.  Press Soft Key 1 [OK] to delete.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 40 4.3.2 PHONE BOOK   This function allows you to search the phone number in three way BY NAME, BY ADDRESS and BY NUMBER, which you have stored in the phone book memory. Upto 300 entries can be listed here.   TO STORE PHONE NUMBER IN PHONE BOOK MEMORY   1.  Enter the area code and phone number (Max. 32 digits) in on-hook state.   2.  Press Soft Key 1 [SAVE].   3.  Enter  the name  in text  mode and press [OK] to save. Press Soft Key 2 [ABC] to change upper, lower case or a specific character.   4  Enter the desired memory location.   5.  The  phone  will  display  a  message  asking  you  whether  to  keep  your  number  as secret or not. Select No or Yes using UP/DOWN button or Soft Key 2 [NEXT] and press [OK].   F  You will see a confirmation message and the status of memory used. [Fast Searching]   Press [FIND] and press [FIND] again. BY NAME   1.  Press FIND + 2(PHONE BOOK) + 1(BY NAME), to retrieve a phone number by name.   2.  Enter the name you want and press [FIND]. To find all phone numbers you have stored, Press [FIND]. BY ADDRESS 1.  Press FIND + 2(PHONE BOOK) + 2(BY ADDRESS),   to retrieve a phone number by address. 2.  Enter a memory address to retrieve phone number   and press [FIND]. To find all phone numbers you have stored, Press [FIND]. BY NUMBER 1.  Press FIND + 2(PHONE BOOK) + 3(BY NUMBER), to retrieve a phone number by number.   2.  Enter the phone number that you want to fine   and press [FIND]. To find all phone numbers you have stored, Press [FIND].
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 41 5.  Speaker Phone   This function  is a convenient feature, which enables  you to make a call using the Speaker Phone (X ) button in on-hook state.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 42 6.  Troubleshooting   Please check the following items before contacting service center.   Item   Remedy   Phone doesn’t operate at all.    Check that the phone is installed correctly.    Check that the battery is fully charged.    Check that the power is on.   Because of noise and cross talking, call status is bad.   Keep away from electrical application such as TV, computer, radio and so on.   When I press button to call, can’t hear the dial tone.   Check that phone cord or power is connected correctly.   Phone does not switch on.    Check that the battery is fully charged and correctly connected to the phone.   Calls cannot be received.    If incoming calls are barred, unlock the incoming call barring/do not disturb.   Emergency calls cannot be made.   Check that the antenna symbol is displayed-Move to the coverage area and operate your phone when the antenna symbol is displayed.   Battery fails to charge.    Ensure the battery is fitted correctly to the phone prior to commencing charging.   Bell sound isn’t heard.    If bell sound is low, please adjust the volume level.
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 43 7.  General Information   7.1  Main Unit   Item   LSP-400   Tx Frequency    Digital: 824 ~ 849 MHz   Rx Frequency    Digital: 869 ~ 894 MHz   Channel Bandwidth    1.25 MHz   Tx Power    Digital: LOWER: 0.2W ~UPPER:1W   Rx Sensitivity    -104 ~ -25dBm   Size (mm)    195  × 162  × 72 (L X W X H)   Weight (gms)    584(included Li-ion battery)   Operating Temperature    -10 to 50℃   7.2  AC/DC Adapter   Item   SMPS Type Description  Rated Input Voltage    AC 100 ~ 240V   Operating Input voltage    AC 80 ~ 300V   Rated Input Frequency    50 / 60Hz   Operating Input Frequency    47 ~ 63Hz   Rated Output Voltage, Current  5V(DC), 700mA    7.3  Battery   Item   Description   Capacity    3.7V Li-ion (Nominal) / 1400mAh   Talk time / Standby time    4 Hours / 120Hours   Charging time duration    3.5 Hours
LG-NORTEL CDMA Fixed Wireless Phone   LSP-400 User Guide 44 Appendix.    Federal Communications Commission (FCC) Information This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in accordance with the instructions, it may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.  If this equipment does cause harmful interference to radio or television reception, which can be determined by tuning the equipment off and on, the user is encouraged to try and correct the interference by one or more of the following measures:  - Reorient or relocate the receiving antenna - Increase the distance between the equipment and the receiver. - Connect the equipment to outlet on a circuit different from that to which the receiver is connected. - Consult the dealer or an experienced radio/TV technician for help.  Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.  Caution: Exposure to Radio Frequency Radiation. To comply with FCC RF exposure compliance requirements, for mobile configurations, a separation distance of at least 20 cm must be maintained between the antenna of this device and all persons. This device must not be co-located or operating in conjunction with any other antenna or transmitter.    Licensed by QUALCOMM Incorporated under one or more of the following Patents:   U.S, Patent No. 4,901,307 U.S, Patent No. 5,056,109 U.S, Patent No. 5,099,204   U.S, Patent No. 5,101,501 U.S, Patent No. 5,103,459 U.S, Patent No. 5,107,225

Navigation menu