Essence Security ES6502HC EverGuard-Care Control Panel User Manual Manual part 1

Essence Security International ltd. EverGuard-Care Control Panel Manual part 1

Contents

Manual part 1

EverGuardCareisaPersonalizedHomeCareSolutiondesignedforthe
growingpopulation,disabledandpeoplethatsufferfromdementiaand
thatwishesto“agepeacefullyathome”.
EverGuardCareControlPanel
ES6502HC
PersonalizedHomeCareSolution
Withmillionsofsystemsandperipheralsinstalledinternationally,EssenceSecurityisa
technologicalandmarketleaderinthefieldofadvancedmachinetomachinesolutionsfor
homes,officesandfullservicecentralmonitoringstations
Adiscreetandpassivemonitoringofthe
individual’sactivitiesofdailyliving(ADL)
assuringhis/herwellbeing.
Thesystemautomaticallylearnsthe
individualbehaviorandnotifiesuponnay
abnormality.
partoftheEssenceGroup
LongRangeDeploymentsover2000feetRFreach
RemoteMonitoringofSystemStatus‐ temperaturereportembeddedinevery
peripheral
VariousCommunicationModules‐ Cellular3G/4G
ReducedShipmentCosts‐ compact,lightweightdesign
LessMaintenance‐ Longbatterylife
ES6502HCControlPanelSpecifications
Wirelesscommunicationwiththeperipherals:
Upto1000metersRFrange(openair)
EndtoendbidirectionalESIprotocol
Advancedradiosupervisionalgorithm
Modulation:BFSK
Frequencies:868.3MHzor916.5MHz
Encoding:32bitID,over4billion
combinations
Highquality,longrangevoiceverification:
TwowayAudio
EnhancedechocancelingDSPbasedalgorithm
Speakerprogrammablegain
Ultrasensitivemicrophone
SafetyFunctionality:
VariousDetectors(Water,Smoke,Gas,etc.)
ExtremeTemperatureDetection
Variouspanic(SOS)devices
Video(externalcamera):
HighResolution&QualityColormotionJPEG
Video*orJPEGStills
RemoteControl:
AutomaticSoftwareUpgrade
RemoteProgrammingandConfiguration
ElectricalPowerSupply:
Input:100240VAC,50/60Hz‐ externalAC
adaptor
LiPolymerrechargeablebackupbatteryforup
to36hours‐ 3.7V,1.4Ah
CommunicationModules:
CellularNetwork:GSM/GPRS/EDGE/3G
CellularModule:Quadband
(850/900/1800/1900MHz)
CommunicationModules:
Interfacingprotocols:SIAorEssence
ProprietaryProtocol(ESI)
Physical:
Dimensions:127x127x72mm(LxWxD)
Weight:560grams(incl.battery)
Color:White&Grey
Mounting:Desktop,Wall,withBracket
Environmental:
OperatingTemperatures:0°~49°Celsius
GeneralFeatures:
PersonalSecurity
Multilanguagevocalreminders
OnboardSOSandcallCMSbuttons
LEDindicationsforsystemstatus
EssenceSecurityInternational(E.S.I.)Ltd.
www.essencegrp.com +972732447777info@essencegrp.com
© 2013 Essence Security International (E.S.I.) Ltd. Information contained within this document may change without notice.
Certificationsandapprovals:
This device complies with FCC Rules Part 15 and with Industry Canada license-exempt
RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may
cause undesired operation
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux
appareils radio exempts de licence. L'exploitation est autorisée aux deux conditions
suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si
le brouillage est susceptible d'en compromettre le fonctionnement.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this equipment not expressly approved by the party responsible for
compliance (Essence Ltd.) could void the user’s authority to operate the equipment.
WARNING! To comply with FCC and IC RF exposure compliance requirements, the device should be
located at a distance of at least 20 cm from all persons during normal operation. The antennas
used for this product must not be co-located or operated in conjunction with any other antenna or
transmitter.
Le dispositif doit être placé à une distance d'au moins 20 cm à partir de toutes les personnes au cours de son
fonctionnement normal. Les antennes utilisées pour ce produit ne doivent pas être situés ou exploités
conjointement avec une autre antenne ou transmetteur.