Essence Security ES700VPD Voice Panic Detector User Manual

Essence Security International ltd. Voice Panic Detector

user manual

Download: Essence Security ES700VPD Voice Panic Detector User Manual
Mirror Download [FCC.gov]Essence Security ES700VPD Voice Panic Detector User Manual
Document ID3192306
Application IDl0hww4MlSEGMBMDawaaS4w==
Document Descriptionuser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize24.22kB (302752 bits)
Date Submitted2016-11-10 00:00:00
Date Available2017-05-08 00:00:00
Creation Date2016-09-27 08:29:06
Producing SoftwareAdobe PDF Library 11.0
Document Lastmod2016-10-06 14:34:49
Document Titleuser manual
Document CreatorAcrobat PDFMaker 11 for Word
Document Author: Usuario de Microsoft Office

Care@Home™
Voice Panic Detector
ES700VPD
Smart Emergency Response Device
Product
Specifications
A wireless, smart emergency response device with Intelligent Voice
Activation™ technology, integrated into the Care@Home™ product suite
solution, providing an added layer of care by allowing residents to “call for
help” when unable to press their panic button.
The Voice Panic Detector features:
• Intelligent Voice Activation™ (IVA): an always-active technology that
recognizes preset vocal commands which trigger specified actions
• Stationary panic button and optional pull cord (detachable or fixed)
• Two power options: battery operated or external power supply with
battery as backup
• Extreme temperature detection
• Voice extender ready (intercom)
• LED indications for emergency and system status
• Water resistant for installation in shower or bathing areas
• Supports automatic over-the-air software (RSU) programming and
configuration upgrade
• Installation using a desktop mount or wall mount using mounting tape
or screws
• Accessories
•
External pull cord trigger
•
Desktop mount
•
AC power adapter
COMMUNICATIONS
Smart Care
COMPLIANCE - Pending
• Maximum RF range: Up to 700 m (2296 ft.) – open air
• Protocols: Proprietary bi-directional radio protocol
• Modulation and frequency: FSK modulation:
•
•
868.3 MHz, 869.225 MHz (in Europe and China)
•
916.5 MHz (in North America)
•
800 MHz (in Israel)
Data security: 32-bit ID, over 4 billion combinations
POWER SUPPLY
• Battery: Two C-size 1.5V alkaline batteries
• Battery life : 3 - 5 years
• Input (optional): 90-240 VAC, 50/60 HZ external AC adapter
DIMENSIONS
• Size: H – 42 mm (1.65 in.), L – 95 mm (3.74 in.), W – 95 mm (3.74 in.)
• Weight: 300 g (0.67 lbs.) not including batteries and accessories
ENVIRONMENT
•
•
•
•
Operating ambient temperature range: 0ºC – +45ºC (+32ºF – +113ºF)
Storage ambient temperature: -10ºC – +60ºC (14ºF – +140ºF)
Operating humidity: Up to 100%
Water and dust resistant – IP54 compliant
• FCC, UL, IC CE, EN50134, AS4607, SRRC
Essence Care@Home™ multi service platform is an Aging-in-Place product
suite that offers a seamless health monitoring experience allowing
independence for seniors and peace of mind to their loved ones.
Care@Home™ allows service providers the flexibility to offer their
customers services ranging from emergency alerting to a professional
intelligent home care solution, which constantly learns and adapts to the
daily behavior of individuals and provides alerts with different severity levels
based on deviation from the daily routine.
The Care@Home multi service platform includes:
• Care@Home PERS Advanced Emergency Response Alarm
• Care@Home Family Monitoring
• Care@Home Pro Intelligent Home Care Solution
NOTE: This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
- Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this equipment not expressly approved by the party responsible
for compliance (Essence Ltd.) could void the user’s authority to operate the equipment.
This device complies with FCC Rules Part 15 and with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may
cause undesired operation
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio
exempts de licence. L'exploitation est autorisée aux deux conditions suivantes:
(1) l'appareil ne doit pas produire de brouillage, et
(2) l'utilisateur de l'appareil doit accepter tout brouillage radioélectrique subi, même si le
brouillage est susceptible d'en compromettre le fonctionnement.
ESUGSC017 Rev. 1.1
For more information, go to http://www.essence-grp.com/smart-care
© 2016 Essence SmartCare Ltd. Information contained within this document may change without notice

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Author                          : Usuario de Microsoft Office
Create Date                     : 2016:09:27 08:29:06+03:00
Modify Date                     : 2016:10:06 14:34:49+03:00
Language                        : EN-US
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Metadata Date                   : 2016:10:06 14:34:49+03:00
Creator Tool                    : Acrobat PDFMaker 11 for Word
Document ID                     : uuid:ba2b3936-e97b-4341-baaf-c4b6b14bcb05
Instance ID                     : uuid:760d787a-ee1f-4249-9bbd-d4d852eee183
Subject                         : 58
Format                          : application/pdf
Creator                         : Usuario de Microsoft Office
Producer                        : Adobe PDF Library 11.0
Source Modified                 : D:20160927052747
Company                         : Microsoft
CR Target                       : 2048
Page Layout                     : OneColumn
Page Count                      : 1
EXIF Metadata provided by EXIF.tools
FCC ID Filing: YXG-ES700VPD

Navigation menu