Essence Security ES800UT Universal transmitter User Manual We R System

Essence Security International ltd. Universal transmitter We R System

User_Guide_part7

Download: Essence Security ES800UT Universal transmitter User Manual We R        System
Mirror Download [FCC.gov]Essence Security ES800UT Universal transmitter User Manual We R        System
Document ID2207797
Application IDlSZpUGVDFDi/AbnhELbl7Q==
Document DescriptionUser_Guide_part7
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize107.78kB (1347262 bits)
Date Submitted2014-03-06 00:00:00
Date Available2014-05-01 00:00:00
Creation Date2013-12-04 16:39:13
Producing SoftwareMicrosoft® Word 2010
Document Lastmod2014-02-12 14:38:36
Document TitleWe.Râ„¢ System
Document CreatorMicrosoft® Word 2010
Document Author: Niv B. Amit

Installation of the We.R™ System
Note: Each Smoke Detector must be tested once a month or any time
suspected as not working properly.
Press the center Test/Mute button In order to test the device.
3.13. The Universal Transmitter (UT) – ES800UT
The Universal Transmitter (UT) is the We.R™ interface onto legacy wired devices.
It connects with ON/OFF type devices, enabling incorporation of 3rd party wired peripherals
into the We.R™ system.
Figure 139: The Universal Transmitter
™
We.R System User Guide
171
Installation of the We.R™ System
Accessories available for the Universal Transmitter:
 Double-sided adhesive tape.
3.13.1.
The Universal Transmitter Function
The Universal Transmitter incorporates the following functions:
 Bi-directional wireless device.
 Flexible application definition as Security Device, Flood/Fire/Gas Detector, Panic
Button, etc.
 May be configured, via the We.R™ Web Application, to Normally Open or Normally
Close modes.
 Dual-LED (green/red) for open/close status indication.
 30 cm (1 feet) cable.
 Data security is ensured with 128-bit AES encryption.
 Up to 500m (1640 feet) RF range (open air) communication.
 Unique electronic serial number.
 Supports automatic over-the-air software upgrade programming and configuration.
 Provides long operation period while powered by a single standard AA-size Alkaline
battery.
3.13.2.
Installing the Universal Transmitter
The Universal Transmitter should be mounted near the device it is interfacing with.
The Universal Transmitter mounting base is the unit’s back cover (where it also serves the
purpose of battery cover).
The base should be disassembled from the Universal Transmitter body, as demonstrated in
Figure 140 below, and attached either by the double-sided tape (pre-attached to the base) or
using screws as demonstrated in Figure 141 below.
172
™
We.R System User Guide
Installation of the We.R™ System
Figure 140: Releasing the Universal Transmitter Base
3.13.2.1.
Universal Transmitter Positioning Recommendations
For optimal safety, the following factors must be taken into consideration when selecting the
Universal Transmitter mounting position:
 A flat vertical surface.
 Attach the Universal Transmitter to a surface that is clean, dry, flat and smooth.
 The Universal Transmitter must be mounted within 700m (2300ft) (open air nominal) of
the CCU.
3.13.2.2.
Installing with Screws
1. Release the Universal Transmitter base by inserting a coin into one of the edge slots, as
demonstrated in the Figure 140 above, and twist it to open the cover.
2. Use a flat screwdriver to remove the punch-outs 1 and 2 (see Figure 141 below).
™
We.R System User Guide
173
Installation of the We.R™ System
Figure 141: Universal Transmitter Base with Screws
3. Place and hold the base on the desired mounting location and mark the drilling locations
(the above-mentioned punch-outs 1 and 2).
4. Drill the holes; insert two (2) dowels if needed, place the base over them and screw in the
two (2) screws.
3.13.2.3.
Installing with Pre-attached Double-side Tape
The pre-attached double-sided tape will be mostly used in installations of the Universal
Transmitter.
1. Release the base (see Figure 140 above).
2. Peel the tapes’ protective covers.
3. Attach the base to its designated location while applying slight pressure.
4. Attach the Universal Transmitter body back into the base.
3.13.2.4.
Dismounting the Universal Transmitter
For dismounting the Universal Transmitter (i.e. in case of battery replacement):
174
™
We.R System User Guide
Installation of the We.R™ System
1. Insert a coin (or flat screw driver) into one of the edge slots as demonstrated in Figure 142
below.
2. Twist it to raise the cover (body) edge.
3. Pull the body strait out of the base’s shoulders.
Figure 142: Dismounting the Universal Transmitter
3.13.3.
Adding the Universal Transmitter to the We.R™ System
The Universal Transmitter need to be functionally added to the system following the above
described physical installation procedure.
The addition of the Universal Transmitter is a standard Add Device procedure performed as
follows:
Note: You may also want to refer to paragraph ‎5.1 below to get acquainted
with the process of installing/ replacing a battery in the Flood Detector.
1. Prepare a single AA-size Alkaline battery required to power the Universal Transmitter.
™
We.R System User Guide
175
Installation of the We.R™ System
2. Activate the We.R™ Web Application.
Figure 143: Add Universal Transmitter Device Utilizing Web Application
3. Select the Devices page (tab) and click over the
button.
4. A roll-down selection menu will open.
5. Click over the _Add Universal Transmitter_ option of the menu as illustrated in Figure 143
above.
6. A window defining the function performed by the legacy wired device opens (see Figure
144 below) where you need to:
 Select the device type.
 Define its mode of operation (normally closed or normally open).
 Optionally mark a request for notification regarding device reset.
176
™
We.R System User Guide
Installation of the We.R™ System
Figure 144: Definition of Function of the Legacy Wired Device
7. Click over the
Click over the
button once all data is selected or marked.
button if you need to terminate this process.
8. Once the
button was clicked over, an Add New Device (Universal Transmitter)
window will pop-up and its timer will start running.
Figure 145: Add Universal Transmitter Window
9. Verify that the Device Type is Universal Transmitter.
™
We.R System User Guide
177
Installation of the We.R™ System
10. The down-counter provides a time-frame of three (3) minutes within which the battery
should be installed to power-up the Universal Transmitter, as demonstrated in Figure 146
below:
Figure 146: Inserting a Battery into the Universal Transmitter
11. Verify battery polarity to match marking within the unit body.
Note: In case the installation of the batteries could not be accomplished
within the three (3) minutes period, it is possible to restart the process by
applying step ‎2 (on page 176) and onwards again.
12. The insertion of the battery into the Universal Transmitter triggers a handshake process in
which the Universal Transmitter communicates with the CCU to inform it of its presence
and the CCU add it to its peripherals’ inventory.
13. If the CCU did not detect the new Universal Transmitter within this time-frame, the following
error ( ) message will appear within the Add New Device window:
178
™
We.R System User Guide
Installation of the We.R™ System
Figure 147: Add New Universal Transmitter Timeout Error Message
In such a case, it is possible to re-initiate the Add New Device process by clicking over the
button.
Clicking over the
button will terminate the Add New Device process.
14. If the new Universal Transmitter was properly detected by the CCU within this time-frame,
the counter will freeze and a Device Properties sub-window will appear within the Add New
Device window, where the Flood Detector’s system name/location needs to be typed-in.
Figure 148: Add New Flood Detector Device Properties
™
We.R System User Guide
179
Installation of the We.R™ System
Clicking over the
button will end the Add New Device process while the new
Flood Detector is added onto the system configuration.
15. You may verify that the Flood Detector (FL) was properly added by checking the details of
the We.R™ Web Application’s Devices page.
3.14. The We.R™ Z-Wave® Controller (ZWD) – ES800ZWD
3.14.1.
The Z-Wave® Concept
Z-Wave®, from Sigma Designs, is a proprietary wireless protocol oriented towards the
residential control and automation (Smart Home) market.
It allows wireless remotely controlled home appliances, products and systems, to be integrated
and work well together in a mesh network modular topology.
Z-Wave® application uses simple, reliable, low-power radio frequency (RF) communication
channel and high reliability protocol to unify home electronics into an integrated wireless
network.
Z-Wave® operates within the Industrial, Scientific, and Medical (ISM) band on a single
frequency using frequency-shift keying (FSK) radio and its throughput is suitable for control and
sensor interface applications.
Each Z-Wave® network (mesh topology) may include up to 232 nodes and consists of two sets
of nodes: controllers and slave devices.
Nodes may be configured to retransmit the message in order to guarantee connectivity in
multi-path environment of the residential house.
Average communication distance between two nodes is 100 feet (30 meters), and with
message ability to hop up to four times between nodes, it gives enough coverage for most
residential houses.
The Z-Wave® interface may be added to almost any electronic device in the house, including
devices that were not meant to be “intelligent” such as appliances, window shades,
thermostats and home lighting.
180
™
We.R System User Guide
Installation of the We.R™ System
All Z-Wave-certified products “speak the same language” to provide true Z-Wave®
interoperability.
A given device must be added to the Z-Wave® network before it can be controlled via ZWave® controller. This process (also known as “pairing” see ‎Appendix G on page 299) is
usually achieved by pressing a button on the device, an operation which must be performed
once, after which the device will always be recognized by the controller.
Devices can also be removed from the Z-Wave® network through a similar process of button
strokes.
3.14.2.
Essence Z-Wave® Controller
Unlike all other We.R™ peripheral devices, the We.R™ Z-Wave® Controller is classified as a
controller (just like the system’s Central Control Unit) and not as a peripheral device.
The Z-Wave® Controller is the We.R™ system interface to Z-Wave® approved Smart Home
devices allowing control of such devices via the We.R™ system thus expanding the We.R™
system’s capabilities and devices’ portfolio beyond Essence ECOP RF protocol capabilities.
The dongle connects to the We.R™ Central Control Unit (CCU) as an add-on.
Figure 149: The Essence Z-Wave® Controller Dongle
The Z-Wave® Controller incorporates two connecting points:
 A cable with a mini-USB™ type connector which connects to the We.R™ Central
Control Unit’s mini-USB™ back-panel socket, and
 A mini-USB™ socket, on its other end, for the Central Control Unit’s power adaptor
connector.
™
We.R System User Guide
181
Installation of the We.R™ System
3.14.2.1.
The We.R™ Z-Wave® Controller Generic Device Classes
In theory, every controllable or controlling device at home can be equipped with Z-Wave®
technology.
Therefore, a broad variety of different devices and functions should be expected. However,
there are some basic functionality patterns that allow categorizing different devices:
 Each device will either control other devices or being controlled by other devices.
In the Z-Wave® terminology, controlling devices are called controllers, reporting devices
are called sensors and controlled devices are called actuators.
 It is also possible to combine a logical sensor controller or actor function within one
physical device.
 Actors switch either digital (i.e. ON/OFF for an electrical switch) or analog signals (i.e. 0
to100% for a dimmer).
 Sensors deliver either a digital signal (i.e. door, glass breaking and motion detector) or
an analogue signal (i.e. temperature, humidity, power).
The Essence We.R™ Z-Wave® Controller was developed to serve as a generic controller
covering all Z-Wave® supported generic device classes.
Four (4) different end-devices were implemented insofar:
 Binary Switches – ON/OFF.
 Multilevel Switches – like a Dimmer.
 Thermostats – like Climate Controllers.
 Door Locks.
Notes: Once integrated into the We.R™ system’s configuration, the ZWave® Controller will accommodate all devices based on these categories,
regardless their manufacturer.
182
™
We.R System User Guide
Installation of the We.R™ System
3.14.3.
Installing the Z-Wave® Controller
Notes: The following procedure of installing the We.R™ Z-Wave® Controller
is based on the assumption that the Z-Wave® Controller is being added
onto a fully operational We.R™ system.
Due to the installation procedure, a Power Failure event will be logged and
a notification should be expected.
1. Disconnect the Central Control
Unit (CCU) from power by
plugging-out the power adaptor
cube from the electric power
(mains) socket.
2. Disconnect the power cord from
the CCU:
Note: The mini-USB™ socket is for the We.R™ power cord only. Do not
connect other USB™ equipment to this socket.
™
We.R System User Guide
183
Installation of the We.R™ System
3. Plug the We.R™ Z-Wave®
dongle’s mini-USB™ connector
into the Central Control Unit’s
mini-USB™ socket (now vacant
from the power cord).
4. Plug the power adaptor’s cord
(previously disconnected from the
CCU) into the dongle’s miniUSB™ socket.
5. Plug the power adaptor cube
back into the mains socket.
184
™
We.R System User Guide
Installation of the We.R™ System
The CCU should be back in full-operational mode (front panel LED turns green) within about 30
seconds. This could be verified as described in paragraph ‎3.14.3.1 below.
Note: The We.R™ Z-Wave® Controller is powered by the We.R™ Central
Control Unit’s power adaptor only and will not be powered by the We.R™
CCU’s backup battery In case of mains power failure.
3.14.3.1.
Verification
Verification of Central Control Unit returned into its fully-operational mode is required following
the installation procedure as well as the addition of the We.R™ Z-Wave® Controller reported by
the system.
The verification is done by activating the We.R™ Web Application software (described above in
paragraph ‎3.3. The We.R™ Web Application) and checking for the We.R™ Z-Wave® Controller
status row in the Dashboard page (see Figure 28 on page 56).
3.14.4.
Activating the Z-Wave® Controller
Once the Z-Wave® Controller is installed, it is time to add the definitions of the Z-Wave®
remotely controlled devices to configure the system to work with them properly.
The next paragraphs detail how to:
 Add new Z-Wave® remotely controlled devices.
 Remove previously added Z-Wave® remotely controlled devices.
 Control Z-Wave® remotely controlled devices via the We.R™ system.
3.14.4.1.
Adding a New Z-Wave® Device
Prior to the process of adding a new Z-Wave® remotely controlled device, you need to get
familiar with the additional Smart Home page in the We.R™ Web Application Data Window.
™
We.R System User Guide
185
Installation of the We.R™ System
The Smart Home page is similar to the previously discussed Devices page (see
paragraph ‎3.3.6.2 above):
Note: Being central to the We.R™ system configuration, the Z-Wave®
Controller, just like the CCU, is not enumerated as a supported device.
Figure 150: The Smart Home Page
Clicking over the
button will open an _Add Z-Wave Device_ selection button
which enables auto-detection of the paired Z-Wave® device:
Figure 151: The Smart Home Page Add Z-Wave® Device
186
™
We.R System User Guide
Installation of the We.R™ System
Once selected, the following Add New Device window will pop-up:
Figure 152: Add Z-Wave® Device Installation Stopwatch
Similar to the standard We.R™ Add Device procedure described above, this is a count-down
stopwatch which counts a period of 3 minutes, within which the pairing button (switch) on the
Z-Wave® remotely controlled device must be pressed to initiate the pairing process
(see ‎Appendix G Pairing and Bonding for details of the pairing process).
Once paired-up, the device will communicate with the We.R™ Z-Wave® Controller and be
configured, according to its features, onto the We.R™ system.
Once communicating properly with the Z-Wave® Controller;
 The stopwatch will freeze, and
 The device will be added to the We.R™ database and will be displayed in the
Smart Home Data Window page.
 The device will appear in the Devices (left) pane and its details, to be manually
typed-in, within the data fields of the right pane.
 Any change made to the data fields in the right pane must be saved by clicking
over the
™
We.R System User Guide
button.
187
Installation of the We.R™ System
Figure 153: A Dimmer Device Added
3.14.4.2.
Removing a Connected Z-Wave® Device
Removing a previously added Z-Wave® remotely controlled device from the We.R™ system is a
similar process to the removal of a We.R™ device:
1. The device to be removed must be selected by clicking over its row in the Device (left) pane
of the Smart Home Data Window.
2. The removal is triggered by clicking over the
button.
A window message will pop-up requesting press on the pairing button on the Z-Wave®
remotely controlled device destined for removal:
188
™
We.R System User Guide
Installation of the We.R™ System
Figure 154: Removal Message for a Z-Wave® Device
In case the device to be removed participates in a scenario (see example in paragraph ‎3.14.4.3
below), the following error message will pop-up instead:
Figure 155: Removal of Z-Wave® Device Participating in a Scenario
The
button need to be clicked upon following the press on the pairing button on the
®
Z-Wave remotely controlled device.
The device selected will be removed from the system and its row, in the left pane, will be
deleted.
For example:
The system presented in Figure 156 below has four (4) Z-Wave® remotely controlled devices –
a dimmer, a door lock, a thermostat and a switch.
Assuming the dimmer need to be removed:
1. Click over the first row in the left pane (the dimmer row) to select it.
2. The row will be highlighted.
™
We.R System User Guide
189
Installation of the We.R™ System
3. Click over the
button.
4. The removal message (see above Figure 154) pops-up.
5. Press the pairing button on the dimmer device.
6. Click over the
button on the removal message.
7. The dimmer will be removed from the system and the row will be deleted.
Figure 156: A Z-Wave® System with Dimmer and Switch Devices
3.14.4.3.
Controlling a Z-Wave® Device via the We.R™ System
Following are some examples of setting up typical Z-Wave® devices (scenarios):
 Setting up Z-Wave® devices to turn ON upon We.R™ system being disarmed:
190
™
We.R System User Guide
Installation of the We.R™ System
The system enables setting devices to turn ON as soon as the We.R™ system is turned
into disarm mode of operation (for example: turning the light and the air-condition ON
as soon as you walk into your home).
To set up such a scenario:
a) Click over the Scenarios tab to open the Scenarios page.
b) Select which scenario is to be set (i.e. turn ON / turn OFF).
c) Select the devices you want to turn ON upon disarm mode of operation by
marking their rows.
Figure 157: Setting up Z-Wave® Devices to Turn ON upon Disarmed
 Setting up Z-Wave® devices to turn OFF upon We.R™ system being armed:
The system enables setting devices to turn OFF as soon as the We.R™ system is
armed (for example: turning the living room light off and locking the door as soon as
you walk out of your home).
™
We.R System User Guide
191
Installation of the We.R™ System
To set up such a scenario:
a) Click over the Scenarios tab to open the Scenarios page.
b) Select which scenario is to be set (i.e. turn ON / turn OFF).
c) Select the devices you want to turn OFF upon arm mode of operation by
marking their rows.
Figure 158: Setting up Z-Wave® Devices to Turn OFF upon Arming the System
Following is an example of controlling typical Z-Wave® device:
 To control a thermostat:
a. Click over the Smart Home tab to open the Smart Home page.
192
™
We.R System User Guide
Installation of the We.R™ System
b. Select which device is to be controlled (i.e. switching ON an air condition
appliance and setting up its temperature and fan speed).
c. Select the device you want to control by marking it row on the left (Device Type)
pane.
d. The selected device details will be displayed in the right pane, in a case of a
thermostat – its ON/OFF switch, Heat/Cool selector, Fan Speed selector,
measured temperature display and Target Temperature setting dial.
e. Accordingly, you can manually turn the air condition ON or OFF, select between
heating or cooling operation, set up the fan speed and set up the desired
temperature.
Figure 159: Controlling a Z-Wave® Thermostat
™
We.R System User Guide
193
Installation of the We.R™ System
Note: Each FLiRS device (i.e. Door Lock, Thermostat, etc.) has a battery
icon added in the status column to indicate its charging level for operation
safety.
3.15. System Support Capabilities
The We.R™ Central Control Unit can support up to a total of 64 devices as detailed in Table 5
below:
Essence P/N
Number of devices
Motion Indoor Photo Detector (IPD)
ES800IPD
Up to 8
Motion Detector (PIR)
ES800PIR
Up to 64 total Security
Door/Window Magnetic Sensor (MGL)
ES800MGL
Up to 64 total Security
Indoor Siren (SRN)
ES800SRN
Up to 3
Remote Control Unit (KF)
ES800KF
Up to 8
Wireless Access Control Tag Reader (TR5)
ES800TR5
Up to 8 in total Security. Up to
total of 8 Tags
Smoke Detector (SK2)
ES800SK2
Flood Detector (FL)
ES800FL
Universal Transmitter (UT)
ES800UT
Safety
Device
Item
Z-Wave® Controller (ZWD)
Users
ES800ZWD
Up to 16 (total Safety)
One (1) Controller and up to
232 Z-Wave® devices
Up to 32 (out of which two are
designated as Master users,
where 1 is a MUST)
Table 5: System Support Capabilities
194
™
We.R System User Guide
Installation of the We.R™ System
Total number of supported peripheral devices is limited by the number of other peripheral
devices already installed in the system.
For example:
 If there are two sirens in the system, the CCU can support only 62 more PIRs
(assuming no other peripherals are defined for the system).
 If there are four PIRs and two Key Fobs, only 58 more peripherals may be
supported.
Note: Being central to the We.R™ system configuration, the CCU is not
enumerated as a supported device. Only one CCU is supported per We.R™
system installation.
Out of the 32 possible Users the system designates up to two Master Users; users with
privileges to change the system’s setup (i.e. add/remove a device, add/remove Users, etc.),
but a minimum of one (Master) must be defined to allow the initial setup and control of the
system.
™
We.R System User Guide
195

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : Niv B. Amit
Create Date                     : 2013:12:04 16:39:13+02:00
Modify Date                     : 2014:02:12 14:38:36+02:00
Subject                         : User Guide
Language                        : en-US
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Format                          : application/pdf
Creator                         : Niv B. Amit
Description                     : User Guide
Title                           : We.R™ System
Creator Tool                    : Microsoft® Word 2010
Metadata Date                   : 2014:02:12 14:38:36+02:00
Producer                        : Microsoft® Word 2010
Document ID                     : uuid:d80e6c30-2756-46c3-ae90-b74ae64ba8bb
Instance ID                     : uuid:2aecaad4-8318-4acb-b8d8-aaca678442ba
Page Count                      : 25
EXIF Metadata provided by EXIF.tools
FCC ID Filing: YXG-ES800UT

Navigation menu