Estone Technology TP35 Control Panel and Relay Black Box User Manual

Estone Technology Inc. Control Panel and Relay Black Box Users Manual

Users Manual

Download: Estone Technology TP35 Control Panel and Relay Black Box User Manual
Mirror Download [FCC.gov]Estone Technology TP35 Control Panel and Relay Black Box User Manual
Document ID3987872
Application ID5Nw8LNecrZ5zjxL6QoxMPA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize32.46kB (405705 bits)
Date Submitted2018-09-03 00:00:00
Date Available2018-09-04 00:00:00
Creation Date2018-08-07 14:37:11
Producing SoftwareAdobe PDF Library 10.0.1
Document Lastmod2018-08-07 14:37:12
Document TitleUsers Manual
Document CreatorAdobe InDesign CS6 (Windows)

Location of key buttons
User Guide
18
10
11
12
13
14
15
16
17
1. SHOWS THE BATTERY / FRESH WATER /
BLACK WATER 1 / BLACK WATER 2 /
GREY WATER 1 / GREY WATER 2 /
GALLEY TANK STATUS
2. AWNING LIGHT (ON/OFF)
3. INTERIOR STEP LIGHT (ON/OFF)
4. CEILING LIGHTS (ON/OFF)
5. PORCH LIGHT (ON/OFF)
6. PANEL POWER (ON/OFF)
7. WATER PUMP (ON/OFF)
8. HEATED TANKS (ON/OFF)
iRV Controller
19
9. WATER HEATER (ON/OFF)
10. CONTROL MAIN SLIDE ROOM IN
11. CONTROL SLIDE ROOM 2 IN
12. CONTROL SLIDE ROOM 3 IN
13. CONTROL AWNING RETRACT
14. CONTROL MAIN SLIDE ROOM OUT
15. CONTROL SLIDE ROOM 2 OUT
16. CONTROL SLIDE ROOM 3 OUT
17. CONTROL AWNING EXTEND
18. UPGRADE CONNECTION
19. RJ45
General operations
Warning: Changes or modifications to this unit not expressly approved by the party responsible for
compliance could void the user’s authority to operate the equipment.
unit backside
Connect to Controller - Relay box
Power On/Off
Press and hold (PANEL POWER) button to power on.
Press and hold (PANEL POWER) button to power off.
Press the button (2/3/4/5/7/8/9) breifly to operate ON/OFF as below:
2. AWNING LIGHT (ON/OFF)
3. INTERIOR STEP LIGHT (ON/OFF)
4. CEILING LIGHTS (ON/OFF)
5. PORCH LIGHT (ON/OFF)
6. PANEL POWER (ON/OFF)
7. WATER PUMP (ON/OFF)
8. HEATED TANKS (ON/OFF)
9. WATER HEATER (ON/OFF)
Press and hold the button (10-17) to control as below:
10. CONTROL MAIN SLIDE ROOM IN
11. CONTROL SLIDE ROOM 2 IN
12. CONTROL SLIDE ROOM 3 IN
13. CONTROL AWNING RETRACT
14. CONTROL MAIN SLIDE ROOM OUT
15. CONTROL SLIDE ROOM 2 OUT
16. CONTROL SLIDE ROOM 3 OUT
17. CONTROL AWNING EXTEND
Symbol level shows the Battery / Fresh water / Black water 1 / Black water 2 /
Grey water 1 / Grey water 2 / Gallery Tank status:
Note: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
●
●
●
●
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Warning:
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20 centimeters between the
radiator and your body.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2018:08:07 14:37:11+08:00
Metadata Date                   : 2018:08:07 14:37:12+08:00
Modify Date                     : 2018:08:07 14:37:12+08:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Instance ID                     : uuid:82caaeee-7050-4c81-a2d6-6f3fb8898b5e
Original Document ID            : xmp.did:F77F117407206811B133A5C52B2C17D5
Document ID                     : xmp.id:67FE30500C9AE811834ADCE1037DCB32
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:FAF565A30B9AE811834ADCE1037DCB32
Derived From Document ID        : xmp.did:E702C74738206811B133A5C52B2C17D5
Derived From Original Document ID: xmp.did:F77F117407206811B133A5C52B2C17D5
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2018:08:07 14:37:11+08:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NV8-TP35

Navigation menu