Everspring Industry Co AC136 Panic Button User Manual AC136 UserManual 20171020
Everspring Industry Co Ltd Panic Button AC136 UserManual 20171020
User Manual
AC136 Testing Panic Button TM 1. For the Panic Button to control other devices on the Z-WaveTM controller by 2 seconds long pressing for Panic and 10 seconds long pressing for disarm, a Scenes needs to be created. Scenes are user defined elements in controller that determines what actions to take when an event occurs. The Panic Button creates the event to this Scene which then controls other activation devices such as plugs or dimmers, or perhaps set the alarm to Arm or Disarm mode. 2. After binding with the Z-WaveTM controller, the Panic Button will send data about its battery power to the Gateway after about 2 minutes. Subsequently it will send the data once the button is pressed.. TM The AC136 Panic Button is a Z-Wave Plus enabled device and is fully compatible with any Z-Wave enabled network. The device can be set up in a Z-wave network to communicate directly with other end devices such as lighting controllers, or to report directly a Z-wave controller (usually a gateway). The Panic Button is a portable wireless switch designed to control the Panic/Disarm status of other associated devices thru the Z-WaveTM controller. After receiving the signals emitted by the Panic Button, the Z-WaveTM controller can then give commands or operate according to its own settings. Its great compatibility with Z-WaveTM products makes it suitable for smart home cloud based platforms. Installation Product Overview The Panic Button can be installed on the wall either by using the supplied double-sided tapes or the screws: 1. Using the double-sided tape: first peel one side of the tape and place the sticky side onto the back of the Panic Button. Then peel the other side of the tape and attach the unit onto a proper location on the wall. 2. Using the screws: LINK Front View Panic ON/OFF Knob Battery Compartments Rear Cover Latch Panic ON/OFF Knob Inside View Link Button LED Indicator Rear View Rear Cover Adding to Z-WaveTM Network i. ii. iii. Auto Inclusion Detach the rear cover by removing the front cover and then pressing the rear cover latch (see item in Product Overview). Use the rear cover as a template to mark on the wall the positions of two screws. The marks should be in horizontal positions and the distance between the two marks is 60mm. Drill the holes using an appropriate size drill bit. Insert the supplied plastic wall plugs first for a cement wall. For a wooden wall the wall plugs would not be needed. The detector supports Auto Inclusion feature where it will automatically enter Inclusion mode when first powered up after a factory reset. 1. Gently lever the bottom edge of the front cover to detach it from the main body. 2. Put a Z-Wave Controller into inclusion mode. 3. Insert 2 AAA-size 1.5V alkaline batteries to battery compartment with the correct polarity. The LED on the device should turns ON. iv. 4. The Inclusion process should be completed when the LED turns off. Note: If Auto Inclusion fails, refer to the Troubleshooting section regarding Manual Inclusion. Position the rear cover on the wall and turn the two screws into the wall (or wall plugs). DO NOT fasten too tightly as the rear cover might be damaged. Then replace the main body and the front cover. Note: Ensure the unit is installed within transmission range of the gateway using the test above. Maintenance 1. 2. 3. Notification Do not put the unit in humid or dusty places or facing direct sunlight. Do not place the unit near combustible substances or any source of heat, e.g. fires, radiators, boilers etc. The suitable ambient temperature for the unit is -10°C - +40°C. Low Battery: The Panic Button will inform the Gateway when its battery runs low. Also, if the unit has completed binding with a Gateway and the front cover is detached, you can see the LED flashes once when you press the up/down key to indicate low battery condition. Programming Z-Wave Group Type Event Program started 0x0C 0x01 Event Parameters Length null Program started Clear 0x0C 0x00 1 byte Program completed 0x0C 0x03 null Program completed Clear 0x0C 0x00 1 byte The power is applied for the first time The battery is Low 0x08 0x01 null 0x08 0x0A null Event Parameters 0x01 0x03 Battery The unit supports either one of two Z-wave Association Groups: Group 1: Association with 1 Controller node. Group 2: Association with 4 nodes (i.e. end devices such as smart plugs and other lighting controllers).This allows the On/Off module to receive commands directly from these end devices without the participation of the controller. Group 1 commands: When the unit is powered for the first time, the unit will send a Notification Report to the node of Group 1. When device status being changed, the unit will send Notification command to the node of Grouping 1. Upon device status being changed, the unit will check its battery status simultaneously. When the battery level of the unit drops to an unacceptable level, the unit will emit Notification report to the nodes of Grouping 1. Device Reset: When performing Factory Reset the unit will send Device Reset Locally Notification to the node of Group1. Group 2 commands: When device is pressed by Up key, the unit will send BASIC SET command which contains a value that is adjustable, to the nodes of Grouping 2. When device is pressed by Down key, the BASIC_SET command will also be sent to the nodes of Grouping 2. Role Type Node Type Installer Icon User Icon Slave Sleeping report Z-Wave Plus node Notification Sensor Notification Sensor Protocol Library 3 (Slave_Enhance_232_Library) Protocol Version 4.6 ( 6.71.00) Product Type 0x000A Battery Report (value) Description 0x64 Battery is high 0x10 Battery is normal 0x00 Battery is low Command Classes COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_ASSOCIATION_V2 * COMMAND_CLASS_ASSOCIATION_GRP_INFO * COMMAND_CLASS_TRANSPORT_SERVICE_V2 COMMAND_CLASS_VERSION_V2 * COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2* COMMAND_CLASS_DEVICE_RESET_LOCALLY* COMMAND_CLASS_POWERLEVEL_V1* COMMAND_CLASS_BATTERY* COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_NOTIFICATION_V8* COMMAND_CLASS_WAKE_UP_V2* COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 * *Items marked an asterisk are secure command classes. Wakeup Command Class After it has been included into a Z-wave network, the detector will go to sleep but will send a Wakeup Notification Command periodically at preset period to the controller. The detector will stay awake for 10 seconds at least and then go back to sleep to conserve battery life. Version Manufacturer Manufacturer ID 0x0060 Event The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class based on the range values below: Product ID 0x0002 AGI (Association Group Information) Table Group Profile Command Class & Command (List) N bytes Group Name(UTF-8) General Notification Report Device Reset Locally Notification Lifeline Control Basic Set Basic Set Minimum Wake Up Interval 600s (10 minutes) Maximum Wake Up Interval 86400s (1 day) Default Wake Up Interval 14400s (4 hours) Wake Up Interval Step Seconds 600s (10 minutes) Troubleshooting The table below lists the several steps involved when adding or removing the detector from the Z-wave network. Action/Status No node ID Description The Z-Wave Controller does not allocate a node LED indication 2-second on, 2-second off Auto Inclusion Manual Inclusion Exclusion Factory Reset (This procedure should only be used when the controller is inoperable.) ID to the unit. For 2 minutes The power is applied for the first time and no node ID has been stored in the module, or after executing reset. 1. Put the Z-Wave Controller into inclusion mode. 2. Press the link button 3 times within 1.5 seconds to put the unit into inclusion mode. 1. Put the Z-Wave Controller into exclusion mode. 2. Press the link button 3 times within 1.5 seconds to put the unit into exclusion mode. 1. Press the link button 3 times within 1.5 seconds to put the unit into exclusion mode. 2. Within 1 second of step 1, press the link button again and hold for 5 seconds. 3. Node ID is excluded. The device reverts to 2-second on, 2-second off factory default state. For 2 minutes Failed or successful results in including/excluding the ID can be viewed on the Z-Wave Controller. Possible Cause 1. Distance between the Panic Button and the receiver(s) too far 2. Battery running low 3. Receivers did not learn ID successfully Recommendation 1. Move closer to the receivers 2. 3. Replace new batteries Bind with Gateway again Specifications Battery Type Battery Life Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Industry Canada statement: Table below lists typical problems encountered: Symptom Press Panic Button, LED illuminates, but the receiver(s) have no response a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: AAA Battery x2 1 year* Transmitting Range Frequency Range Up to 100 meters line of sight EU: 868.42HMz US: 908.42 MHz JP: 922.5MHz FCC ID FU5AC136 IC 23210-AC136 Specifications are subject to change without notice *measured at 1 trigger per day This device complies with ISED’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d’ ISED applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable. Radiation Exposure Statement: This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body. Déclaration d'exposition aux radiations: Cet équipement est conforme aux limites d'exposition aux rayonnements ISED établies pour un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps. Warning: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge. Federal Communication Commission Interference Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in www.everspring.com 50 Sect. 1 Zhonghua Rd Tucheng NewTaipeiCity 236 Taiwan.. A501112653R01
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2017:10:24 19:20:11+08:00 Modify Date : 2017:10:24 19:20:11+08:00 Author : 101696 Subject : Page Count : 3 Page Layout : SinglePage Page Mode : UseNone XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:cc6d3d38-bb08-11e7-0000-9247eaf900f7 Producer : PDFCreator 2.4.1.13 Keywords : Creator Tool : PDFCreator 2.4.1.13 Document ID : uuid:cc6d3d38-bb08-11e7-0000-9247eaf900f7 Format : application/pdf Title : AC136_UserManual-20171020 Creator : 101696 Description :EXIF Metadata provided by EXIF.tools