Everspring Industry Co HSE03 Voice Siren User Manual

Everspring Industry Co Ltd Voice Siren

User manual

Download: Everspring Industry Co HSE03 Voice Siren User Manual
Mirror Download [FCC.gov]Everspring Industry Co HSE03 Voice Siren User Manual
Document ID3523941
Application ID41+eSBUkN29UPb3ioGh/Hg==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize15.26kB (190724 bits)
Date Submitted2017-08-23 00:00:00
Date Available2017-08-23 00:00:00
Creation Date2017-08-18 16:38:32
Producing SoftwareAcrobat Distiller 9.0.0 (Windows)
Document Lastmod2017-08-18 16:38:32
Document TitleMicrosoft Word - HSE03-0 Voice Siren Homesys-20170817_刪除adapter選配
Document CreatorPScript5.dll Version 5.2.2
Document Author: A316164

HSE03
Voice Siren
Installation Instructions
General Introduction
Keys
A. Speaker
B. Voice Speaker
C. Backplate screws
D. Backplate
The HSE03 Voice Siren is a two-way wireless alarm device which functions
not only as a siren, but also a strobe light with voice indicator functions. Its
great compatibility with our U-Net family security products makes it suitable for
smart home cloud based platforms such as Homesys.
E. Tamper Switch
F. Learning Key
G. Micro USB (Factory use only)
H. DC Jack
Functions
HSE03 includes the following functions:
* Tamperproof protection
* Green and red flashing strobe light
* Visual and audible alarm indications
* 6 indicating beep sounds for identification
* EEPROM for non-volatile memory facility
* LED for identification, visual command confirmation and battery status
A.
B.
E.
Siren Speaker
Voice Speaker
Tamper Jumper Link
F. Learning Key
G. Micro USB
H.
Product Layout
DC Jack
Siren Warning 110 dB
Voice Indicator 90 dB
A full alarm condition will be enabled when the device is
removed from the wall.
Learn and clear ID codes.
Update voice messages through the USB cable. (Factory
use only)
Socket for connecting DC adapter
Binding with Homesys
1. Loosen and remove the locking screw from the bottom edge of the unit
counter clockwise.
2. Slide the backplate out of the unit.
Figure 1 Front View
Figure 2 Under View
3. Prepare four 1.5V alkaline batteries. Do not insert them into the unit yet.
4. Log into the Homesys account from a web browser.
Figure 3 Back View
Figure 4 Inside View
5. Select “System”, then “Add a Device”,
8. Insert the batteries with correct polarity at this point.
6. Select “Voice Siren”.
9. The screen below will appear in 10 seconds if the process is successful.
7. The following screen will appear. This means the gateway is entering
binding mode.
10. Time-out will occur if the binding process was unsuccessful. Please check
“Manual Binding”.
If there is no response from HSE03 please check the “Troubleshooting”.
Manual Binding
1. Repeat steps 6 to 8 of the Binding with Homesys section.
2. Press and hold the learning key “F” (as shown in Figure 4) for more than 3
seconds until the green strobe LED turns off, then quickly release the
learning key. The Green LED will flash repeatedly. This implies HSE03
has now entered the binding mode and is waiting to receive binding
signals from the gateway.
3. Within 5 seconds the green LED will stop flashing indicating the learning
procedure is completed. The screen below will appear indicating the
process is successful.
Mounting the HSE03
The HSE03 should be mounted inside the building in a position that is clearly
visible and at a height which is relatively inaccessible to an intruder. It is also
suggested not to mount the unit in the basement to avoid poor transmission.
1. Use the backplate as a template to mark and drill the position of 3 mounting
holes on the wall. Fix the backplate to the wall using the plastic wall plugs and
fixing screws provided.
Testing
HSE03 can be tested with Homesys smartphone App by changing the security
mode between ARM and DISARM on the App and the listening for voice
indication from HSE03.
2. Slide the unit down to the backplate and fasten the locking screw clockwise.
Tamper Protection
Reset to factory default:
Tamper switch is set inside the housing of HSE03 to prevent it from being
forcibly removed from the wall. Removing the unit from backplate will release
the tamper switch and generate a full alarm condition.
To reset HSE03 back to factory default state:
1. Insert the batteries into the unit
2. Press and hold the learning key “F” (as shown in Figure 5) for more than 3
seconds until the green strobe LED turns off, then release the learning key.
The Green LED will flash repeatedly. This implies HSE03 has now entered
binding mode and is waiting to receive binding signals from the gateway.
3. Press and hold the learning key for more than 6 seconds and release
within 30 seconds, during which it will sound every 0.5 seconds with green
LED turned on. The learning procedure is completed when a longer beep
tone has sounded and the LED will flash orange every 2 seconds.
Maintenance
* Do not immerse this unit in water or any other liquid.
* Four 1.5V Alkaline LR14 batteries are supplied in the HSE03. When battery
is low, a red LED will flash every 30 seconds. When this situation occurs,
replace the batteries as soon as possible.
Specifications
Power adaptor (option)
Battery Type
Battery Life
Operating Frequency
600 mA@6V DC
1.5V LR14 x 4
About one year in standby mode at 25°C
868MHz (EU)/ 923MHz (America)
** Specifications are subject to change and improvement without notice.
Troubleshooting
The troubleshooting table lists some possible causes and solutions. Please
contact your original retailer or nearest service center if the below solutions
cannot solve your problem.
Symptom
HSE03 LED indicator
stops displaying
Possible Cause
No battery is inserted or
battery is flat
HSE03 failure
The display function of
HSE03 LED indicator
is operating properly,
but the siren doesn’t
respond to alerts and
system changes.
1.The binding process
has failed
2.The siren cannot
communicate with the
Homesys gateway.
WARNING:
Do not dispose of electrical appliances as unsorted municipal waste, use
separate collection facilities instead. Please contact your local government for
information regarding the collection systems available.
Recommendation
Check if 4 batteries are inserted
properly
Send the unit to the service
center and do not open it
1.Please follow the instructions
for Manual binding.
If electrical appliances are disposed of in landfills or dumps, hazardous
substances can leak into the groundwater and get into the food chain,
damaging your health and well-being.
When replacing old appliances with new once, the retailer is legally obligated
to take back your old appliance for disposal at least for free of charge.
2.Place the siren closer to the
gateway.
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
www.everspring.com
3F., No. 50, Sec 1, Zhonghua Rd., Tucheng Dist.,
New Taipei City 23666, R.O.C
residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one of the
following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject to
the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to operate this
equipment.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : A316164
Create Date                     : 2017:08:18 16:38:32+08:00
Modify Date                     : 2017:08:18 16:38:32+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Format                          : application/pdf
Creator                         : A316164
Title                           : Microsoft Word - HSE03-0 Voice Siren Homesys-20170817_刪除adapter選配
Creator Tool                    : PScript5.dll Version 5.2.2
Producer                        : Acrobat Distiller 9.0.0 (Windows)
Document ID                     : uuid:acd7edc0-b29d-4df1-8bf8-b8052fd660cd
Instance ID                     : uuid:c9f4fa71-9de1-495d-963b-4797ba0d932d
Page Count                      : 5
EXIF Metadata provided by EXIF.tools
FCC ID Filing: FU5HSE03

Navigation menu