Everspring Industry Co SA802 Wireless Keypad User Manual POOL ALARM
Everspring Industry Co Ltd Wireless Keypad POOL ALARM
User manual
SOLAR-POWERED POOL ALARM SYSTEM FOR SAFETY AID TO READ ATTENTIVELY AND TO PRESERVE FOR FUTURE CONSULTATION WARNING This system is simply a safety aid which announces a danger (or risk of danger) when an equivalent of 8kgs (18 pounds) object falls into a unsupervised swimming pool. The fast intervention in less than 3 min of a responsible adult is obligatory when the signal of alarm happens. Ensure the construction of the pool wall is solid enough, thus it can stand the drilling of the screws and wall plugs without cracking the pool wall. After installation, ensure the pool alarm itself cannot be shaken, otherwise it will affect the performance of pool alarm detection. In the event of any injury or death to any person arising out of misuse, abuse, negligence, accident or alteration, Everspring Tech USA, Inc., will not be liable for any consequence caused. This system does not replace the good direction nor with the several liability. The purpose of it is not to either replace the vigilance of the parents and/or the responsible adults, which remains the essential factor for the protection of the children with less than five years; The user who turns OFF the system must be conscious that the human monitoring must take over; It is imperative to react when the signal of alarm happens; The greatest vigilance of the responsible parent /adult is necessary between the end of the bathe and the reactivation of the product; Never leave children unattended in or around the swimming pool or spa. Children under five years of age are at the greatest risk for injury or death in pool-related accidents. In the event of possibility of stroke with against current: "Cancel the stroke with against current at the end of the bathe to allow the reactivation of the product". Some of cleaning robots as a plunger robots type are incompatible with the systems of detection of immersion PRODUCT LAYOUT Solar-powered Wireless Pool Alarm (ST113) Battery Cover Solar Panel Start Button Base Sensing Compartment Detachable Tube Wireless Keypad (SA802) Setting/Low Battery LED Keypad Function Key Sequence Function Key Description System Off System On Auto Disarm the alarm sound Siren & Strobe (SE802) Strobe Light Red & Green LED ( when both LEDs are on, the LED will be converted into orange color) Tamper Switch Learning Key DC Jack Two-Phase Sound Jumper Link Anti-jamming Jumper Link Tamper Jumper Link Mounting Bracket The kit includes one piece each of Solar-powered Wireless Pool Alarm, Siren & Strobe and Wireless Keypad, all of which products have been designed to aid in the detection of unwanted intrusions into unclosed above ground or in ground swimming pools. THE SOLAR-POWERED WIRELESS POOL ALARM IS NOT A LIFE SAVING DEVICE. It should be used along with other safety equipment and precautions. It is intended to provide an additional level of security to your swimming pool and/or spa. This unit is not intended to replace any other safety consideration : adult supervision, lifeguards, fences, gates, pool covers, locks, and so forth… And some devices may not detect gradual entry. INTRODUCTION The solar-powered pool alarm is an electronics device that, in armed mode, automatically sounds an alarm when children or pet fall into your unsupervised pool. Entry into the above ground/in ground pool will be detected by the unit’s electronics sensor, triggering a loud pulsating alarm. Apart from it, the pool alarm is also compatible with our U-Net series, serving as a transceiver. PACKAGE CONTENT The solar-powered wireless pool alarm system is packaged in a gift box that minimizes the chance of damage due to handling. The contents of the package include the following items: Solar-powered Item Qty wireless pool alarm system(ST113) Base Initiation key LR20 Alkaline Battery Detachable tube (φ4.7x30mm) Screw Plastic wall plug Siren & Strobe (SE802) (φ3 x 18mm) Screw Plastic wall plug 1.5V LR14 14A Size C Wireless Keypad (SA802) (φ3 x 18mm) Screw Plastic wall plug Operating instruction manual Solar Panel with Ni-MH AA 6V Rechargeable battery SOLAR-POWERED WIRELESS POOL ALARM INSTALLING THE POOL ALARM There are four detachable tubes which can be jointed to a long tube. The length of tube depends on water level in the pool. The distance from the bottom end of tube to water level must be greater than 24.5cm. (9.7 inch) A power drill and screwdrivers are needed for installation. Note: The unit may not function properly if your pool’s water level is not maintained within the required levels of your device. 4.5cm Under Water level 24.5cm Sensing Compartment Tube Base 1. Locate the appropriate (plain and not very grassy) place to fix the unit on the top rail of the swimming pool. For the above ground pool, the unit must be installed at a height of 1.5m (59 inch) above the ground. 2. Joint the number of tubes according to actual water level as measured. 3. Insert the tube to the sensing compartment by fastening it through the base using the screw provided. 4. Use the base as a template to mark the position of four fixing holes. Drill four 30mm fixing hole and fit the plastic wall plugs to the holes. 5. Aim the base to the place where four plastic wall plugs are situated. Fasten the base using the fixing CH (7.1 2C 18. 14.6 CM( 5.75 INCH screws supplied. LOADING THE BATTERY Caution: - use only the alkaline batteries as those provided. - do not use out-of-date batteries (respect the expiry date), - do not throw your old batteries in a dustbin : they contain toxic products, which are dangerous for the environment. You must deposit them in vats envisaged for this purpose that you will find in great surfaces, retailers, town halls... Follow the below steps in sequence to load the batteries. 1. Remove four rubber stoppers and undo four fixing screws from the battery cover. 2. Open the battery cover and insert 4 x 13A LR20 1.5V alkaline batteries. 3. Plug the power supply cord to the DC jack. 4. Replace the battery cover and fixing screws. Refit the rubber stoppers. Note: Reverse battery cover cannot fit to the compartment. Power Cord DC Jack WIRELESS KEYPAD The Wireless Keypad is used to control the Pool Alarm by using a four digit Administrator password. The Keypad is powered by 3 x AA 1.5V alkaline battery. an expected life in excess of 1 year. Under normal operating conditions this will provide When the battery level falls below an unacceptable level, the “Setting/Low Battery” LED on the front of the Keypad will flash 4 times when pressing any key. When this occurs the batteries should be replaced as soon as possible. POSITIONING THE KEYPAD The Keypad should be mounted in a position close to the main entrance door so that the Administrator password can be entered easily. Ensure that the position selected for the Keypad is within the effective range of the solar-powered wireless pool alarm. Note: DO NOT fix the Keypad to metalwork or locate the unit within 1m of metalwork (i.e. radiators, water pipes, etc) as this could affect the radio range of the Keypad. INSTALLING AND CONFIGURING THE KEYPAD 1. Undo and remove the fixing screw from the bottom edge of the Keypad and remove the wall mounting bracket. 2. Using the mounting bracket as a template, mark the positions of the two fixing holes on the wall. 3. Fix the mounting bracket to the wall using the screws and wall plugs provided. Do not over-tighten the fixing screws as this may distort or damage the mounting bracket. 4. There is one jumper link located above the battery compartment. Jumper link J1: Reset to Factory default If unfortunately you forget the Administrator password, reset the Administrator password to factory default by proceeding with the following steps in sequence: (1) (2) Remove the batteries. Set the Jumper link J1 to off position as shown on Fig. a. OFF ON Fig. a Fig. b (3) Refit the batteries. The keypad is reset properly by flashing back light 0~9 3 times. (4) Set the Jumper link J1 to on position as shown on Fig. b. 5. Connect the 3 x AA alkaline batteries to the battery compartment. 6. Click the Keypad to the mounting bracket and screw the fixing screw. Do not over-tighten the fixing screw. Note: The Keypad is supplied with a default Administrator password of: 1234. For security reasons, it is recommended that this password is changed to another four digit number which only you and other users of the system know. Note: The Keypad has back light illumination facility. The back light of digit number 0~9 won’t be off until 5-second illumination duration expires each time when you press any key. Once transmission is successful the back light of digit number 0~9 will extinguish. Failure to input any key more than 5 seconds after each pressing will be treated as invalid input. The back light of digit number 0~9 will flash 3 times as an indication. CHANGING THE ADMINISTRATOR PASSWORD Default Password: 1 2 3 4 To change the Administrator password, press the following keys in sequence: (1) Press Original Administrator password (2) Enter New Administrator password SIREN & STROBE (SE802) The Siren & Strobe serves as an auxiliary accessory to the Pool Alarm. When the Pool Alarm detects unwanted intrusions into unclosed swimming pools, a full alarm condition will occur. Simultaneously, the Siren & Strobe will initiate a full alarm condition as an intensive warning. POSITIONING THE SIREN & STROBE The Siren & Strobe is suitable for indoor use only. Ensure that the position selected for the Siren & Strobe is within the effective range of Pool Alarm. INSTALLING AND CONFIGURING THE SIREN & STROBE (1) Undo and remove the fixing screws from the mounting bracket. (2) Place 4 x 1.5V alkaline LR14 batteries to the battery compartment. Ensure that correct polarity of the batteries is inserted. (3) Use the mounting bracket as a template to mark the positions of fixing holes on the wall. (4) Fix the mounting bracket to the wall using the plastic wall plugs and fixing screws provided. (5) According to the functions of the product layout, choose or justify the ones that suit you most. Red & Green LED Function Description Green LED: RF transmission When red & green LED confirmation illuminate simultaneously, Red LED: Warning indication orange LED will be indicated Strobe Light Warning indication Learning Key Learning and cleaning out the preset ID code Tamper Switch A full alarm condition will be Enable or disable this function initiated against the unit being using tamper jumper link. removed from the wall Jumper link fitted – enable Jumper link removed - disable Tamper Jumper Link Enable or disable this function Jumper link fitted – enable Jumper link removed - disable Anti-jamming Jumper Link Enable or disable this function Jumper link fitted – enable Jumper link removed - disable Two-phase Sound Jumper Link DC Jack Sound volume selectable – 90 or Jumper link fitted – 100 dB 100 dB/1 meter Jumper link removed – 90 dB Use AC/DC adaptor Jumper link fitted Jumper link removed Enable Disable (6) By releasing the tamper switch from being pressed if the tamper jumper link is enabled, the unit will generate a full alarm condition by flashing its strobe light for about 6.5 minutes and red LED illuminating shortly. (7) If the battery level drops below unacceptable level, the red LED of the unit will flash shortly every 30 10 seconds. When this occurs, the batteries should be replaced as soon as possible. (8) In order to detect any attempts to illegally jam the radio channel used by your alarm system, a special jamming detection function is incorporated into the unit. There are two types of jamming detection. a. If this feature is enabled, and the radio channel is jammed continuously for 30 seconds, when the pool alarm is armed, the unit will emit a pre-alarm series of bleeps for 10 seconds. If the jamming continues while 10 seconds of pre-alarm series of bleeps has elapsed, a full alarm condition will occur for 30 seconds. b. If the unit is jammed for more than three periods of 10 seconds in a 6.5 minute interval, this will also generate a full alarm condition for 30 seconds. Note: If the ambient environment of radio frequency is turbulence, set the anti-jamming jumper link disabled by removing its jumper link. OPERATING INSTRUCTIONS Note: Failure to press the start button by only turning the initiation key cannot operate the system. The prerequisite to enter armed or auto mode is to keep pressing and holding the start button by turning the initiation key as an effective operation. The Pool Alarm has been tested and certified in a 4m x 8m rectangular swimming pool. If your pool is larger, or irregularly shaped, two units or more will be needed (Ask a help near your distributor). In order to properly detect, the Pool Alarm must be installed at the middle of the longest side of your pool, so that the effective detection coverage can be attained to the greatest extent. Using the Wireless Keypad (SA802), of which mounting height is recommended at 1.7m above the ground, may control the Pool Alarm remotely. Pool Alarm 4m 8m FIG. 6 11 Typical examples of installation are shown below: 4m 8m Be sure that the Pool Alarm is not installed next to any pool features (jets, water features, etc.) that may cause disturbance. Be sure that the Pool Alarm can be accessed easily. INITIAL POWER-UP When powering up initially, the Pool Alarm will enter the armed mode straight away. At this stage, you may switch the Pool Alarm to the desired mode or wait for 30 seconds before throwing a 8 kgs (18 pounds) object to the pool which will lead to a loud pulsating alarm sound both from the Pool Alarm and the Siren & Strobe. It allows you to verify if the function of piercing alarm sound is working properly and to be sure if the sound volume of Siren & Strobe can be heard inside your home. TURNING ON THE POOL ALARM 1. Press and hold the start button on the Pool Alarm by turning the initiation key from OFF ON OFF position. 3 bleeps can be heard as an acknowledgement after releasing the start button. The unit will start detecting ambient environment for 8 – 14 minutes. The main purpose of it is to detect the wave intensity of water action avoiding false alarming resulted from wave being caused by strong wind. After completion of ambient environment detection, the Pool Alarm will bleep continuously for 3 seconds, confirming that the system has been armed. 12 Start Button OFF ON Auto OFF ON Auto Initiation Key 2. The Pool Alarm will instantly be monitoring your pool for an intrusion. 3. Using the Wireless Keypad: Press Administrator password 4. In case of unwanted intrusions into a swimming pool, the Pool Alarm will generate a full alarm condition, while the auxiliary Siren & Strobe will alarm and flash for 30 seconds. Note: If the Pool Alarm keeps on detecting the ambient environment without being armed properly, possible reasons are: a. After swimming, the water in the pool will rock or bounce up and down the pool wall for some time depending on the size of the pool and the type of swimming activity. after swimming, the pool must be given time to calm. Before initiation the unit, Time will vary (around 5-10 minutes); once the pool water is no longer rocking up and down the pool wall, it is time to operate the unit. b. On extremely windy days such bad weather, the unit cannot detect correctly. TURNING OFF THE POOL ALARM 1. Press and hold the start button by turning the initiation key either from OFF OFF position. AUTO or from ON Do not release the start button until several bleeps are heard. 2. The Pool Alarm will bleep in response and enter the sleep mode, which means no automatic activation will occur. 3. Using the Wireless Keypad: 13 Press Administrator password AUTO MODE 1. Press and hold the start button by turning the initiation key from OFF AUTO OFF. 3 bleeps can be heard as a confirmation after releasing the start button. The Pool Alarm will enter the auto mode. Prior to entry into the pool, user may either turn off the unit or set the unit to auto mode. In auto mode, the Pool Alarm won’t be triggered, but it will keep detecting the pool status. When no more wave intensity of water action is detected, the mode of the system will be changed from auto to armed mode. The minimum duration of auto mode is 30 minutes, starting from the unit being set at auto mode to automatic change to armed mode. In auto mode, the unit will keep extending its auto mode duration persistently as long as continuous wave intensity of water action has been detected. As a result, the unit is likely to be set at auto mode for a long time. When you have finished swimming, there are no waves on the pool. Press the start button by turning the initiation key from OFF ON OFF, then release the start button. Secondly, wait for the elapse of ambient environment detection, so that the system will enter the armed mode. 2. Using the Wireless Keypad Press Administrator password DISARMING THE ALARM SOUND Upon detecting an unwanted intrusion into an unsupervised pool, the Pool Alarm and the Siren & Strobe will sound immediately. To disarm the alarm sound, you must initiate a two-step operation. To achieve the required alarm status, choose from one of the modes 1-3 below: 1. Turning off the Pool Alarm: Press and hold the start button by turning the initiation key either from OFF AUTO or from ON OFF position. Do not release the start button until several bleeps are heard. The unit will bleep in response and then enter the sleep mode, which means no activation will occur. 2. Turning on the Pool Alarm: Press and hold the start button on the Pool Alarm by turning the initiation key from OFF ON OFF position. 3 bleeps can be heard as an acknowledgement after releasing the start button, the unit will start detecting ambient environment for 8 – 14 minute. 3. Auto mode: Press and hold the start button by turning the initiation key from OFF AUTO OFF. 3 bleeps can be heard as a confirmation after releasing the start button. The unit will enter the auto mode. 14 4. Using the Wireless Keypad Press Administrator password After the Alarm sound is disarmed, the Pool Alarm will enter armed mode straight away. LEARNING THE ID CODE In order to prevent any unauthorized attempt to operate or disarm your system, you must configure your system to accept radio signals only from your own system devices. Firstly, have the Pool Alarm and the Siren & Strobe learned the ID code with each other. the Pool Alarm and the Wireless Keypad learned the ID code. the units. Secondly, have This may ensure correct operation among So, please follow strictly the sequences as mentioned below: Pool Alarm and Siren & Strobe 1. Press and release the learning key on the Pool Alarm. The LED of start button will turn orange and flash, which implies the unit enters the ID code learning mode. 2. Press the learning key on the Siren & Strobe for more than 3 seconds, during which continuous bleeps will be underway while the green LED will be on. 3. If learning the ID code is successful, the Siren & Strobe will end up with a medium bleep and the green LED will be changing from on to off, while the Pool Alarm will bleep once as a confirmation without flashing the orange start button LED. If failed, the Siren & Strobe will initiate three rapid bleeps as a notification. Note: When putting the Siren & Strobe into use without any ID code being memorized or cleaning out all of the preset ID codes, the orange LED will flash at 2 seconds interval and emit short bleep at about 10 seconds interval. Pool Alarm and Wireless Keypad 1. Press and release the learning key on the Pool Alarm. The LED of start button will turn orange and flash, which implies the unit enters the ID code learning mode. 2. Press on the Wireless Keypad Administrator password Enter Note: During code learning period, all four function keys -will be flashing simultaneously for 30 seconds. 15 DC Jack Learning Key CLEANING OUT THE PRESET ID CODE Pool Alarm Press and hold the learning key on the Pool Alarm for more than 6 seconds will clean out the preset ID code. 1 bleep can be heard as an acknowledgement. Siren & Strobe Press the learning key on the Siren & Strobe for more than 3 seconds and release. Within 30 seconds, press the learning key again for more than 6 seconds, during which medium bleeps can be heard while the green LED is on steadily. A long bleep with the green LED being off represents the clearance of all of the preset ID codes. If failed, three rapid bleeps will be emitted from the Siren & Strobe as a notification. QUICK GUIDELINE FOR LED INDICATION AND BLEEP SOUND ON THE POOL ALARM Mode System on / System off / Enter auto Status Continuous 3 short-bleep mode Ambient environment detection Red flashing LED (0.1 second on, 0.5 second off) Auto mode Green flashing LED (0.5 second on, 2.5 second off) Enter armed mode Continuous bleep for 3 second with red illuminating LED Armed mode indication Red illuminating LED 0.1 second at 10 second interval Strong wind indication Orange illuminating LED 0.1 second at 10 second 16 interval and bleep 0.1 second at 30 second interval Low battery indication (under armed Bleep 0.5 second and illuminating LED 0.5 second at mode) 30 second interval Keep pressing start button Orange illuminating LED Learning the ID code period Orange slow flashing LED Alarm activation Red illuminating LED QUICK GUIDELINE FOR LED INDICATION AND BLEEP SOUND ON THE SIREN & STROBE Mode Status Press learning key for more than 3 3 short-bleep and one medium bleep in the end seconds to enter ID code learning mode Green illuminating LED for 3 seconds Learning the ID code period Intermittent short-bleep repeatedly Green flashing LED repeatedly Success in learning the ID code Medium bleep once Green illuminating LED then off Failure in learning the ID code 3 intermittent short-bleep Green flashing LED 3 times Press learning key again for 6 seconds Short bleep intermittently for 6 seconds to clean out the preset ID code Green illuminating LED for 6 seconds Success in cleaning out the preset ID Long bleep once code Failure in cleaning out the preset ID 3 intermittent short-bleep code Green flashing LED 3 times Empty ID code Short-bleep at 10 seconds interval repeatedly Orange flashing LED repeatedly QUICK GUIDELINE FOR LED INDICATION ON THE WIRELESS KEYPAD Keypad Status Success Failure back light 0~9 extinguish back light 0~9 flashing 3 times back light 0~9 extinguish back light 0~9 flashing 3 times Turning off the pool alarm Turning on the pool alarm 17 back light 0~9 extinguish back light 0~9 flashing 3 times back light 0~9 extinguish back light 0~9 flashing 3 times Auto mode Disarming the alarm sound Pressing any key or back light 0~9 will be on function key Learning the ID code back light 0~9 extinguish and 4 mode function keys illuminate back light 0~9 flashing 3 times simultaneously for 1 second Warning: Strong wind indication: When the Pool Alarm is under armed mode detection, the wave pattern of water action may be intensified resulted from strong wind or other interference. converted to strong wind indication automatically. As a result, the Pool Alarm will be In the presence of strong winds, or very bad weather, the Pool Alarm will not be able to carry out correct detection. In armed mode detection with still wave pattern of water action, the Pool Alarm may be generated a full alarm condition if it rains cats and dogs suddenly. GENERAL SWIMMING POOL SAFETY GUIDELINES - The safety of your children depends only on you! The risk is maximum when the children have less than five years. The accident does not arrive only at the others! Be ready to face there! - Supervise and act : - the monitoring of the children must be brought closer and constant; - designate only one person in charge for safety; - reinforce the monitoring when there are several users in the swimming pool; - learn how to swim with your children as soon as possible; - wet nape of the neck, arm and legs before entering water; - learn the gestures which save and especially those specific to the children; - prohibit the dive or the jumps in the presence of young children; - prohibit the sharp race and plays with the accesses of the swimming pool; - do not authorize the access to the swimming pool without waistcoat or life jacket for a child not knowing well to swim and not accompanied in water; - do not leave toys in the vicinity and in the basin which is not monitored; - permanently maintain a water limpid and healthy; 18 - store the pesticides of water out of the range of the children; - certain systems of stroke with against current do not allow the automatic reactivation of the system of detection of immersion; - certain robots of cleaning of plunger the robots type are incompatible with the systems of detection of immersion; - in order to prevent the access to the basin with the children of less than five years at the time of the release of the signal of failure, to take all measurements necessary until repair. - envisage: - accessible telephone close to the basin not to leave your children without monitoring when you telephone; - buoy and pole near the basin; - permanent information that the basin and its accesses are under electronic monitoring, - only the change of the piles, batteries is authorized, and fuses, which must be done at the beginning of season; - in the event of accident: - as soon as possible leave the child water; - call help immediately and take the advice which will be given to you; - replace the clothes wet by hot covers; - to memorize and post close to the swimming pool the numbers of first aid: - firemen: (18 for France); - SAMU: (15 for France); - poisons centre. MAINTAINING THE POOL ALARM REPLACING THE BATTERIES Replace the batteries whenever a low battery is indicated (see page 17 for a description of the low battery indication). Be sure to turn the unit off whenever replacing the batteries. SPECIAL CONSIDERATIONS DURING WINTER The unit will not operate if the water in your pool becomes frozen. in the tube can damage the unit’s sensing mechanism. 19 Additionally, allowing water to freeze If your pool is located in an area where freezing normally occurs and you do not intend to maintain your pool in a heated state throughout the winter season, you should remove the unit before freezing occurs. Store the unit indoors and re-install when the water has thawed. Be sure to remove the batteries from the unit when placing it in storage for a prolonged period. Corrosion may occur if the batteries are left in the unit during storage. PERIODIC TESTING It is recommended that the unit be tested on quarter basis. Before testing, prepare the following test simulator. Fill a 2.5-gallon (11.3 liter ) water container with enough water to weigh approximately 18 pounds ( 8kg). Tie a 6-foot (1.8meter ) length of rope to the container handle . Follow the steps in sequence as mentioned below for testing: Re-turning on the unit will initiate the system, of which operation is referred to page 12 “TURNING ON THE POOL ALARM”. Hold the rope, and roll the test simulator into the pool. Wait a moment for the unit to generate a full alarm condition. If an alarm condition has not been occurred, refer to troubleshooting for resolution. TROUBLESHOOTING Symptom Possible Cause Recommendation Upon power being connected, Batteries were not fitted Remove and refit the batteries the Pool Alarm cannot enter properly or reverse battery armed mode directly polarity LED indicator not working on LR20 batteries or rechargeable 1. Remove and refit the batteries or the Pool Alarm battery are not connected 2. Call to local service for repair properly Initiation key not working replace batteries LR20 batteries or rechargeable 1. Remove and refit the batteries or battery are not connected replace batteries properly 2. Send the unit for repair Low battery indication Run out of battery power Replace LR20 batteries Wireless keypad (SA802) Failure in learning the ID code 1. Resume ID code learning process cannot control solar-powered 2. Clean out the preset ID code and wireless pool alarm resume ID code learning process 20 Abnormal activation Tube is not saturated by enough water level 1. Reallocate the mounting position of the unit 2. Add an extra tube 3. Add much water to the pool thus enhancing water level LED indicator not working on Did not fit the batteries or Check if the batteries are fitted or the Siren & Strobe insufficient battery level replace new batteries The unit is out of order Send the unit for repair, do not open up the casing of the unit Siren & Strobe’s LED indicator Failed to learn the ID code Check if the initial installation of the working, but cannot learn the between the Pool Alarm and Pool Alarm had been cleaned out the ID code or cannot control Siren & Strobe preset ID code. According to the operating manual of Pool Alarm, resume the ID code learning procedure. Interfered by radio frequency. Wait for a while to retry Someone might transmit 868.3MHz adjacently. Siren & Strobe cannot be Failed to learn the ID code Check if the initial installation of the controlled by the Pool Alarm between the Pool Alarm and Pool Alarm had been cleaned out the Siren & Strobe preset ID code. According to the operating manual of Pool Alarm, resume the ID code learning procedure. Too far distance Relocate mounting location between the Pool Alarm and Siren & Strobe Replace a new battery Press key on the Keypad, LED no reaction Remove and refit the battery with correct polarity Proceed with learning the ID code The connected wireless pool alarm not working Ensure correct operation of learning the ID code Reset to the factory default setting Forgot password on the Keypad 21 SPECIFICATIONS Model No. ST113 Solar-powered Wireless Pool Alarm Item Siren Twin piezo siren Siren Output 110 dB / 1 meter Effective Pool Alarm 4m x 8m (157.5 inch x 315 inch), subject to Min. 6 kgs (13 pounds) object Dimension being fallen Operating Power Power Supply 6 VDC Solar panel with Ni-MH AA 6V rechargeable battery and 1.5V x 4 alkaline battery LR20 Frequency 923 MHz Transceiver (USA) Working Range Above ground pool at 1.5m height above the ground : Up to 90m In ground pool: Up to 70m Protection Degree IPX5 0°C ~ 45°C Operating Temperature Safety NF P90-307A1(France) / CE/FCC/ASTM (USA) Model No. SA802 Wireless Keypad Item AA 1.5V alkaline battery x 3 Battery 923 MHz Frequency Communication Range Up to 100m (3937 inch) in open space Model No. SE802 Siren & Strobe Item Battery or Adapter 6VDC Frequency Communication Range 923 MHz Up to 100m (3937 inch) in open space *Specifications are subject to change without prior notice. ASTM A501110701R Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. 22 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. Any changes or modifications (including the antennas) made to this device that are not expressly approved by the manufacturer may void the user’s authority to operate the equipment. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. IMPORTANT NOTE: FCC Radiation Exposure Statement: This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. End users must follow the specific operating instructions for satisfying RF exposure compliance. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. WARNING: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. When replacing old appliances with new once, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge. WARRANTY 1) Warranty period: 2 years as from the date of purchase (the sales slip or the purchase invoice will have to be provided for the execution of the guarantee). Please complete the Exhibit-A form and send it back for your product registration. 2) Conditions of the guarantee: - Without damage of the legal guarantee, the products are recognized provided in good operating condition, without apparent defect and are guaranteed if they are used according to the instructions contained in the Instruction manual. - The guarantee comprises the following services: A helpline : help with the installation, parameter setting, brought into service and resolution of breakdowns not requiring the return of the material in workshop RMA (Repair in workshop) by repairing or standard exchange of the returned defects items. 23 - The guarantee does not cover: transport charges as well as the expenses related with an intervention in residence. Claws, stripes, glares and/or imprint etc... not noted with the delivery Breakable accessories except manufacturing defect recognized by our engineering departments, Batteries - The contractual guarantee does not apply in the event of: Not respect of the instructions of installation; Abnormal Use of the products like use or incorrect connection; Damage due to shocks of any origin; Damage due to fire, sets fire to, penetration of liquid or solid substances; Damage due to an overload, the lightning; Damage due to a modification or intervention carried out by any unauthorized person by HZE; Damage due to a natural disaster, floods or vandalism. CONTACT US Please feel free to write or call us with your comments or questions at the address below. Everspring Tech USA, INC 3200 Wilshire Blvd. South Tower, STE# 1730 Los Angeles, CA. 90010 Tel: (626) 698-1898, Fax: (626) 956-0600 Email: steve_chang@everspring.com EXHIBIT –A– PLEASE TAKE THE TIME TO COMPLETE YOUR DETAILS BELOW AND RETURN With a proof of buying (Invoice or bill) To : Via email : customerservice@everspringamerica.com Via courrier : 3200 Wilshire Blvd. South Tower, STE# 1730 Los Angeles, CA. 90010 Tel: (626) 698-1898, Fax: (626) 956-0600 24 Customer Title (Mr/Ms) First Name Middle Initial Last Name Address Zip Code City Country Email Telephone (area code) Fax (area code) - - Retailer Name Date of purchase City Country Model No S/N P/N 25
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 25 XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:e0e7e175-9fe0-44f7-b6d9-d63ef1504047 Producer : Acrobat Distiller 6.0 (Windows) Company : Everspring Source Modified : D:20071119102652 Headline : Create Date : 2007:11:20 10:16:59+08:00 Creator Tool : Acrobat PDFMaker 6.0 for Word Modify Date : 2007:11:29 16:53:50+08:00 Metadata Date : 2007:11:29 16:53:50+08:00 Document ID : uuid:66de108f-8247-476f-a54e-4d0029b20b0d Version ID : 2 Format : application/pdf Title : POOL ALARM Creator : 100003 Subject : Tagged PDF : Yes Author : 100003EXIF Metadata provided by EXIF.tools