Everspring Industry Co SF804 Wireless Photoelectric smoke alarm User Manual
Everspring Industry Co Ltd Wireless Photoelectric smoke alarm
User Manual
SF804-0 Smoke Detector Installation Instructions General Introduction The SF804-0 Smoke Detector is designed to sense smoke that comes into the detector’s chamber. It does not sense gas, heat, or flame. When it detects a certain density of smoke the horn will sound and the RF module will emit signals to the Gateway. Its great compatibility with our U-Net family security products makes it suitable for smart home cloud based platforms such as Homesys. Transmitter module: Front and Back view Product Layout Horn Test Button Smoke LED Connector pins Cover Latch Battery Cover The sensor consists of two parts; a sensor module and a transmitter module The transmitter module can be detached by twisting it clockwise against the sensor module. Sensor module Transmitter module Tamper switch Connector Learning key 10 Link LED ○ ⑪ Mounting bracket Skirt Panel Binding with Homesys 1. Twist the transmitter module clockwise to detach it from the sensor module 2. Disconnect the connector from the connector pins of the sensor module. Take note of the connector direction as you will need to connect it back later. 3. Open the battery cover. Sensor Module : Front and Back view 9. Insert the batteries with correct polarity at this point. 10. Plug the connector back to connector pins of the sensor module. Make sure its direction is correctly inserted according to the sticker affixed on the sensor. 4. Prepare one 9V alkaline battery. Do not insert it into the unit yet. 5. Log into the Homesys account from a web browser. 6. Select “System”, then “Add a Device”, 11. The screen below will appear in 10 seconds if the process is successful. 7. Select “Smoke Detector”. 12.Time-out will occur if the binding process was unsuccessful. Please refer to the “Manual Binding” procedure. Manual Binding 8. The following screen will appear. This means the gateway is entering binding mode. 1. Repeat steps 4 to 8 of the Binding with Homesys section. 2. With the battery inserted and connector connected to sensor module, press and hold the Learning key for 3 seconds then release, and the Link 10 will start to flash. This implies SF804-0 has now entered binding LED ○ mode. 3. Within 5 seconds, the Link LED will stop flashing and then turn off, indicating counterclockwise. the learning procedure is completed. The screen below will appear indicating the process is successful. 2. Use a 5mm drill bit to drill two holes and insert the provided plastic wall plugs. 3. Use the two screws and provided plastic wall plugs to attach the bracket to the wall. 4. Line up the slot of the bracket and the detector. Push the detector onto the mounting bracket and turn it clockwise to fix it into place. Pull outward on the detector to make sure it is securely attached to the mounting bracket. Testing 1. Assemble the transmitter module back to the sensor module. Note: The smoke LED will flash once every 30 seconds to indicate normal operation 2. Press and hold the test button for 3 seconds, the sensor LED will flash and the horn will emit a loud sound. 3. If the test is successful the system will trigger an alarm and the smoke detector will sound (alarms are listed in “Events”). Note: It is necessary that the Homesys gateway is powered and connected to internet. Tamper Protection Tamper switch is set inside the housing of SF804-0 to prevent it from being forcibly removed. 4. If the test is unsuccessful, please check the troubleshooting. Mounting the SF804-0 Maintenance The detector is designed for use in a single family home or apartment. For complete coverage, it should be installed in all rooms, halls, storage areas, basements and attics in each family living unit. Minimum coverage is one detector on each floor and one in each sleeping area. 1. One 9V alkaline battery is supplied in the SF804-0. Replace the battery once a year. When battery level drops, the detector will beep once every 30 seconds and emit radio signals to the gateway. When this occurs, the battery should be replaced immediately. 1. Remove the mounting bracket ⑪ from the detector by rotating it 2. Clean and vacuum the dust off the detector’s sensing chamber with a soft cloth when changing the battery. WARNING: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities instead. Please contact your local government for information regarding the collection systems available. Troubleshooting The troubleshooting table lists some possible causes and solutions. Please contact your original retailer or nearest service center if the below solutions If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. cannot solve your problem. Symptom SF804-0 LED indicator not illuminating No alerts from the smoke sensor appear on Homesys interface Possible Cause Recommendation 1. No battery is inserted or battery is flat gateway. 2. The smoke detector may be out of order. 1. Binding process failed. 1. 2. The smoke detector cannot communicate with the gateway HSC04. 2. Place the smoke detector closer to the gateway. When replacing old appliances with new once, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge. Check if the battery is inserted properly or replace battery Federal Communication Commission Interference Statement 2. Send the device in for repair and do not open it 1. Follow the steps for “Manual Binding”. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular Reset to factory default: installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and To reset SF804-0 back to factory default state: 1. Insert the batteries into the unit 2. Press and hold the Learning key for more than 3 seconds and release. The red LED starts to blink. 3. Within 30 seconds, press and hold the button for more than 6 seconds. The LED will start to flash, implying the device is reset back to factory mode on, the user is encouraged to try to correct the interference by one of the following measures: - Reorient or relocate the receiving antenna. - Increase the separation between the equipment and receiver. - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Specifications Battery Type Operating Frequency Range Battery Life (alkaline) - Consult the dealer or an experienced radio/TV technician for help. 9V /540mA alkaline battery x 1 868MHz (EU) / 923MHz (America) Up to 200 meter line of sight About 1 year @stand-by mode This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference ** Specifications are subject to change and improvement without notice. that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. FCC RF Radiation Exposure Statement: 1. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 2. This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 centimeters between the radiator and your body. www.everspring.com 3F., No. 50, Sec 1, Zhonghua Rd., Tucheng Dist., New Taipei City 23666, R.O.C
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Create Date : 2017:07:28 15:06:00+08:00 Modify Date : 2017:07:28 15:06:00+08:00 XMP Toolkit : Adobe XMP Core 5.4-c006 80.159825, 2016/09/16-03:31:08 Format : application/pdf Title : untitled Producer : Acrobat Distiller 11.0 (Windows) Document ID : uuid:c890e44b-0752-43d2-83e6-21d68e310e8c Instance ID : uuid:32d86844-7def-4c82-99a8-0f1c518e183f Page Count : 5EXIF Metadata provided by EXIF.tools