SM810 DOOR/WINDOW DETECTOR  The Door/Window Detector is a Z-Wave PlusTM enabled device and is fully compatible with any Z-WaveTM enabled network. The device can be set up in a Z-wave network to communicate directly with other end devices such as lighting controllers, or to report directly to a Z-wave controller (usually a gateway).  Z-WaveTM  enabled  devices  displaying  the  Z-WaveTM  logo  can  also  be  used  with  it  regardless  of  the manufacturer,  and  ours  can  also  be  used  in  other  manufacturer’s  Z-WaveTM  enabled  networks.   Inclusion of this Door/Window Detector on other manufacturer’s Wireless Controller menu allows remote turn-on of connected modules and their connected lighting when the Detector is triggered.  Product Overview LEDTAMPERSWITCHBATTERY BATTERYMYLARFIXEDSCREW Adding to Z-Wave Network  Auto Inclusion The detector supports Auto Inclusion feature where it will automatically enter Inclusion mode when first powered up after a factory reset.   1.  In the front casing, there is a tamper switch which is used to carry out inclusion, exclusion or reset.      2.  Put a Z-Wave Controller into inclusion mode. 3.  Insert  2  CR2032  batteries  to  the  battery  compartment  with  the  correct  polarity.  The  LED  on  the device will turns on.              4.  The Inclusion process should be completed when the LED turns off.  Note: If Auto Inclusion fails, refer to the Troubleshooting section regarding Manual Inclusion. Testing  1.  Remove the battery cover with the tamper switch not being pressed on the detector (test mode), detach or close the magnet from the Detector, the LED on the detector will illuminate. 2.  After proper installation and test, put the battery cover back to the detector and the detector enters the normal mode.  Note: After removing batteries, wait for 5 seconds to refit batteries.  Mounting the Detector  Choosing the location The Door/Window Detector is suitable for mounting in dry interior locations only.  Decide which doors/windows are to be protected by Door/Window Detectors, (usually the front and back doors as a minimum will have Door/Window Detectors fitted).    Additional detectors may also be fitted where required to other vulnerable doors or windows, (e.g. garage, patio/conservatory doors etc).  Note: Take  care when  fixing  the  Detector  to  a metal  frame, or  mounting  within  1m  of  metalwork  (i.e. radiators,  water  pipes,  etc)  as  this  could  affect  the  radio  range  of  the  device.    If  required,  it  may  be necessary to  space  the magnet  and  detector away from  the metal surface  using  a plastic  or wooden spacer to achieve the necessary radio range.  Installation  1.  Use the adhesive tape to fit detector on the door or window. 2.  Fit the magnet to the moving part of the door/window opposite the detector using the adhesive tape. 3.  Ensure  that  the  parallel  gap  between  the  magnet  and  detector  is  less  than  20mm  and  that  the matching line on the magnet is pointing towards and aligned with the line on the detector. An alarm condition will be occurred if the gap is greater than 35mm.    Operation  1.  If first use of SM810 with no node ID, LED will turns ON for 30 sec. when first power on the device to lead the user for auto inclusion. After Inclusion is completed, the device will stay awake for 25 sec. for set up by user from the controller. After 25 sec., the unit will enter sleeping mode, if set up is still needed, the user can press tamper switch for SM810 to be awake for another setting.    2.  Due to limited power from CR2450, the unit may not continuously operate for a long time due to power  consumption.    Therefore,  set  up  time  for  SM810  should  be  minimized,  and  repeatedly press of Tamper should be avoided as well, in order to prevent unusual incident by a quick battery voltage drop down.    3.  User can enter test mode by releasing the Tamper switch; in the meantime if magnetic  sensor is triggered then the LED will be illuminated.    User can confirm whether the Tamper switch has been pressed properly by implementing this function.    When Tamper switch is to be pressed and enter normal  mode,  LED  will  not  be  illuminated  even  if  the  magnetic  sensor  is  triggered,  unless  low battery is detected.  4.  When the tamper switch is pressed, the unit enters normal mode and the red indicator LED on the Detector will not illuminate to conserve battery life when the detector is triggered, (unless the battery power is low).      Battery Cover  45° Battery Cover CR2450  Battery Detector  Magnet
Programming  Z-Wave Group  The detector supports either one of two Z-wave Association Groups: Group 1: Association with 1 Controller node. Group 2: Association with 4 nodes (i.e. end devices such as smart plugs and other lighting controllers). This  allows  the  detector  to transfer  commands  directly  to  end  devices without  the participation  of the controller. This has the effect that when the detector triggers, all devices associated with detector will be operated.  Group 1 commands:   When  the  unit  is  powered  up  and  was  already  a  part  of  a  Z-Wave  network,  the  unit  will  send  a Notification Report to the node of Group 1.   When the tamper switch is released, the unit will send ALARM REPORT command to the nodes of Group 1.   Upon detector status being changed, the unit will check its battery status simultaneously. When the battery level of the unit drops to an unacceptable level, the unit will emit Battery report to the nodes of Group 1.   When performing Factory Reset the unit will send Device Reset Locally Notification to the node of Group1.    Group 2 commands:   When the door/window is opened, the unit will send BASIC_SET command which contains a value to the nodes of Group 2.   When the door/window is closed, the BASIC_SET command will also be sent to the nodes of Group 2.  Z-Wave Plus Info Role Type  Node Type  Installer Icon  User Icon Slave Sleeping report Z-Wave Plus node Sensor Notification Device Type (Access Control) Sensor Notification Device Type (Access Control)  Version Protocol Library  3 (Slave_Enhance_232_Library) Protocol Version  4.6 ( 6.71.00)  Manufacturer Manufacturer ID  Product Type  Product ID 0x0060  0x0002  0x0003  AGI (Association Group Information) Table Group  Profile  Command Class & Command (List) N bytes  Group Name(UTF-8) 1  General  Notification Report Device Reset Locally Notification  Lifeline 2  Control  Basic Set  Basic Set  Notification Event  Type  Event Event Parameters Length Event Parameters The power is applied for the first time  0x08 0x01 null  The battery is Low 0x08 0x0A null  Door/Window detector trigger OPEN 0x06 0x16 null  Door/Window detector trigger Close 0x06 0x17 null  Tamper switch being press more than 10 seconds and released 0x07 0x03 null  Tamper switch being press  0x07 0x00 null   Battery Battery Report (value)  Description 0x64  Battery is high 0x10  Battery is normal 0x00  Battery is low  Command Classes  The module supports Command Classes including…   COMMAND_CLASS_ZWAVEPLUS_INFO_V2   COMMAND_CLASS_ASSOCIATION_V2*   COMMAND_CLASS_ASSOCIATION_GRP_INFO*   COMMAND_CLASS_TRANSPORT_SERVICE_V2   COMMAND_CLASS_VERSION_V2*   COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2*   COMMAND_CLASS_DEVICE_RESET_LOCALLY*   COMMAND_CLASS_POWERLEVEL*   COMMAND_CLASS_BATTERY *   COMMAND_CLASS_SECURITY     COMMAND_CLASS_SECURITY_2   COMMAND_CLASS_NOTIFICATION_V8*   COMMAND_CLASS_WAKE_UP_V2*   COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4*  *Items marked an asterisk are secure command classes.  Wakeup Command Class After it has been included into a Z-wave network, the detector will go to sleep but will send a Wakeup Notification Command periodically at preset period to the controller. The detector will stay awake for 10 seconds at least and then go back to sleep to conserve battery life.  The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class based on the range values below:    Minimum Wake Up Interval 600s (10 minutes) Maximum Wake Up Interval 86400s (1 day) Default Wake Up Interval 14400s (4 hours) Wake Up Interval Step Seconds 600s (10 minutes)  Troubleshooting The table below lists the several steps involved when adding or removing the detector from the Z-wave network.  Action/Status  Description  LED indication No node ID  The Z-Wave Controller does not allocate a node ID to the unit. 2-second on, 2-second off For 2 minutes
Auto Inclusion The power is applied for the first time and no node ID has been stored in the module, or after executing reset.  Manual Inclusion 1. Put the Z-Wave Controller into inclusion mode.  2. Press the tamper switch 3 times within 1.5 seconds to put the unit into inclusion mode. Exclusion 1. Put the Z-Wave Controller into exclusion mode.  2. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode. Factory Reset (This procedure should only be used when the controller is inoperable.) 1. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode.  2. Within 1 second of step 1, press the tamper switch again and hold for 5 seconds.  3. Node ID is excluded. The device reverts to factory default state. 2-second on, 2-second off For 2 minutes  Failed or successful results in including/excluding the ID can be viewed on the Z-Wave Controller. Table below lists typical problems encountered:  Symptom Possible Cause Recommendation Cannot carry out inclusion and association Included a node ID allocated by other Z-Wave Controller.  Exclude a node ID then carry out inclusion and association with new Controller. Does not fit batteries or run out of battery power.  Check if batteries are fitted or replace a new battery. LED not illuminating and not working Does not fit batteries or run out of battery power.  Check if batteries are fitted or replace with new batteries. Break down Send it for repair and do not open up the unit.  Specifications Battery  CR2450 3.0V 620mAh Lithium Battery x 2 Battery Life  1 year* Range  Up to 100 meters line of sight Frequency Range  EU: 868.42HMz US: 908.42 MHz JP: 922.5MHz FCC ID  FU5SM810 IC  23210-SM810 Specifications are subject to change without notice *measured at 10 triggers per day                                                          Federal Communication Commission Interference Statement  This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.    These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.    However, there is no guarantee that interference will not occur in a particular installation.    If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:  -  Reorient or relocate the receiving antenna. -  Increase the separation between the equipment and receiver. -  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -  Consult the dealer or an experienced radio/TV technician for help.  FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.  This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.  Radiation Exposure Statement:  This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.  Industry Canada statement: This device complies with ISED’s licence-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Le présent appareil est conforme aux CNR d’ ISED applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes : (1) le dispositif ne doit pas produire de brouillage préjudiciable, et (2) ce dispositif doit accepter tout brouillage reçu, y compris un brouillage susceptible de provoquer un fonctionnement indésirable.    Radiation Exposure Statement:  This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.  Déclaration d'exposition aux radiations: Cet  équipement  est  conforme  aux  limites  d'exposition  aux  rayonnements  ISED  établies  pour  un environnement non contrôlé. Cet équipement doit être installé et utilisé avec un minimum de 20 cm de distance entre la source de rayonnement et votre corps.  WARNING:  Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities.   Contact your local government for information regarding the collection systems available. If  electrical appliances  are  disposed  of  in landfills  or dumps, hazardous substances can  leak  into  the groundwater and get into the food chain, damaging your health and well-being. When  replacing  old  appliances  with  new  ones,  the  retailer  is  legally  obligated  to  take  back  your  old appliance for disposal at least for free of charge.       www.everspring.com 50 Sect. 1 Zhonghua Rd Tucheng   NewTaipeiCity 236 Taiwan.. A501112654R01

Navigation menu