Everspring Industry Co SP814 MOTION DETECTOR User Manual Manual SP814 ZDK4 54 20131007
Everspring Industry Co Ltd MOTION DETECTOR Manual SP814 ZDK4 54 20131007
UserMan
Adding to Z-WaveTM Network SP814 MOTION DETECTOR In the rear casing, there is a learning key which is used to carry out inclusion, exclusion or association. Put a Z-WaveTM Wireless Controller into inclusion/exclusion/association mode, and press the learning key on the detector 3 times within 1.5 seconds, the detector beeps whenever you press the learning key. The Motion Detector is a Z-WaveTM enabled device which is fully compatible with any Z-WaveTM enabled network. Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturer’s Z-WaveTM enabled networks. This Motion Detector can control our modules via controller setting. Inclusion of this Motion Detector on other manufacturer’s Wireless Controller menu allows remote turn-on of connected modules and their connected lighting when the detector is triggered. Z-WaveTM nodes in the system also act as repeaters if they support that function. Auto Inclusion Besides carrying out the inclusion procedure by pressing the learning key, the detector executes the function of auto inclusion when… 1. The power is first supplied where no ID code has been stored in the detector. The orange LED flashes on and off alternatively and repeatedly at 2-second intervals. The Motion Detector is designed with two detecting sensors, Passive Infra-Red (PIR) sensor and light sensor, in order to fulfill the purpose of security and home automation. When the detector is cooperated with security appliances, it is acting as a security device by detecting changes in infra-red radiation levels. If a person moves within or across the device field of vision, a trigger radio signal will be transmitted to cause full alarm condition in order to frighten intruders away. Alternatively, when the detector is worked with home automation appliances, the detector can be set to perform the role of home automation device by detecting both changes in infra-red radiation levels and percentage of lux levels. Once night falls, the percentage of ambient illumination is lower than preset value. If a person moves within or across the device field of vision, a trigger radio signal will be transmitted so as to turn on the connected lightings for better illumination. 2. The execution of exclusion/reset is successful where the stored ID code(s) is (are) cleared. Note: The node information of explorer frame will be emitted once every 5 seconds during 4 minutes auto inclusion until the inclusion process is complete. The detector cannot execute detecting function if no ID code has been stored in it. Refer to the following table for functions indication and operation: Two mounting methods are provided for varying detection range. The detector can be mounted on a wall for farther detecting distance but narrower coverage; while for ceiling mounting, shorter detecting distance can be made but desired coverage can be expected at user’s disposal. Product Overview Function Description Indication No node ID The Z-Wave Controller does not allocate a node ID to the unit. 1. Have Z-Wave Controller entered inclusion mode. 2. Pressing learning key 3 times within 1.5 seconds will enter inclusion mode. 1. Have Z-Wave Controller entered exclusion mode. 2. Pressing learning key 3 times within 1.5 seconds will enter exclusion mode. 1. Press learning key 3 times within 1.5 seconds. 2. Within 1 second, press and hold learning key for 5 seconds until LED is OFF. 3. IDs are cleared and all settings will be reset to factory default. 2-second on, 2-second off One short beep when learning key is pressed Inclusion Exclusion Reset Rear View 3 Inside View 1 Front View 1 Lens Cover (wall-lens cover and ceiling-lens cover) 2 Photocell Sensor 4 Two-Color Indication LED (red & green) 3 PIR Sensor 5 Learning Key One short beep when learning key is pressed One short beep when learning key is pressed One long beep for 5 seconds 2-second on, 2-second off (for 4 minutes) Association 1. Have Z-Wave Controller entered association mode. Note: For more information on how to configure the Basic Set Command, please refer to the section of Basic Set Level on page 4. One short beep when learning key is pressed 2. Pressing learning key 3 times within 1.5 seconds will enter association operation. Reset To reset the device, simply press the learning key on the detector 3 times within 1.5 seconds, and then press and hold the learning key within 4 seconds until beep sound stops. Home ID and node ID stored in the detector will be cleared and the detector will be restored to factory default. 3. There are two groupings – 1 and 2. See the following section for more info. Including a node ID allocated by Z-Wave Controller means inclusion. Excluding a node ID allocated by Z-Wave Controller means exclusion. Failed or successful results in including/excluding the node ID can be viewed from the Z-Wave Controller. When “Exclusion” is completed, the parameter 1 of configuration will be restored to default value, while other parameters will retain their settings before exclusion. Choosing a Mounting Location The Motion Detector can be mounted either on a wall or under a ceiling. Before selecting a position for Motion Detector, the following points should be noted: 1. Do not position the detector facing a window/fan/air-conditioner or direct sunlight. Note: The Motion Detector will stay “awake” for ten minutes when power is first supplied to allow time for configuration. (I) Grouping 1 (max. 1 node) 2. Do not position the detector directly above or facing any source of heat, e.g. fires, radiators, boiler etc. If the device (e.g. Z-Wave controller) is associated into detector’s Grouping 1, the associated device will receive report commands from the detector when event occurs. Three types of reports can be emitted by the detector, they are: 3. Ensure the detector is positioned in place where the light source detected by the detector is consistent with actual ambient illumination. Do not locate the detector in a shadowy place. Event Type Report Type Power Up ALARM_REPORT (Alarm Type = 02, Alarm Level = 0x01) PIR Status PIR Trigger On PIR Trigger Off Low Battery Status 4. Where possible, mount the detector so that the logical path of an intruder would cut across the fan pattern rather than directly towards the detector (FIGURE 1). BINARY SENSOR REPORT (Sensor Value = 0xFF) BINARY SENSOR REPORT (Sensor Value = 0x00) ALARM_REPORT (Alarm Type = 01, Alarm Level = 0xFF) (II) Grouping 2 (max. 3 nodes) FIGURE 1 5. For best results, locate the detector directly facing an entrance. If a device (e.g. On/Off Module) is associated into the detector’s Grouping 2, the device will receive Basic Set Command from the detector if PIR sensor/light sensor of the detector has been triggered. Installation BASIC_SET (Value = 0 or 1-99), where Value = 0 (indicates “Off”) Value = 1-99, 0xFF (indicates “On” for binary switch, e.g. On/Off Module or “Dim Level” for multilevel switch device, e.g. Lamp Module) 1. Undo and remove the screw from the bottom edge of the detector to detach the rear cover (FIGURE 2). 2. Unscrew the screw from the battery cover and remove the battery cover. 3. Insert 3 AA-size 1.5V alkaline batteries to the battery compartment, ensuring correct polarity is put (FIGURE 3). FIGURE 2 4. 5. (I) FIGURE 3 Two ways of mounting are applicable to the detector. Decide the detector is to be wall-mounted (FIGURE 4a) or ceiling-mounted (FIGURE 5a) based on the coverage angles shown in FIGURE 4b and FIGURE 5b. Hold the rear cover in position and mark the two mounting holes. Drill the holes, insert the plastic wall plugs and screw the rear cover to the wall or ceiling using the screws supplied. FIGURE 5a FIGURE 5b Settings Coverage Range Adjustments Two types of lens covers are provided for the detector. Wall-lens cover (FIGURE 6a) is to be used when the detector is wall-mounted, whereas ceiling-lens cover (FIGURE 6b) is to be used when the detector is ceiling-mounted. The coverage range adjustment is only applicable to ceiling-lens cover; choose correct lens cover before mounting. Engage the detector to the rear cover firmly. Wall Mounting The recommended position for wall mounting is at the height of 1.8m (5.91 ft) from the floor. At this height, the optimum detection range is up to 10m (32.81 ft) with coverage range of 110 degrees (FIGURE 4b). FIGURE 6a FIGURE 4a FIGURE 6b The shading cap is composed of 12 segments for limiting the detection coverage, and each segment covers detection angle of 30 degrees (FIGURE 6c). Follow the grooves on the cap, cut the cap to a suitable size and place it onto the ceiling-lens cover (FIGURE 6d). The remaining segments are used for blanking off an undesirable detection area. FIGURE 4b One segment is removed (II) Ceiling Mounting The recommended position for ceiling mounting is at the height of 2.8m (9.19ft) from the floor. At this height, the optimum detection range is up to 5m (16.41ft) with coverage range of 360 degrees (FIGURE 5b). FIGURE 6c FIGURE 6d Wall Mounting Simply turn the cover anticlockwise to remove the wall-lens cover from the detector (FIGURE 6e). 1. Place the wall-lens cover onto the detector. 2. By walking into a protected area within coverage of 110 degrees, the detector will now be triggered each time the detector senses movement. The orange LED on the detector will be illuminated and the associated appliances will be activated. For example, siren will be sounded or indication of movement detection will be shown on the controller. It implies that the unit is working properly. Ceiling Mounting FIGURE 6e Once the wall-lens covers is removed, reload the detector with ceiling-lens cover and turn it clockwise, ensure the mark on the cover is pointing towards and aligned with the mark on the detector (FIGURE 6f). 1. Place the ceiling-lens cover (shading cap free) onto the detector. 2. By walking into a protected area within coverage of 360 degrees, the detector will now be triggered each time the detector senses movement. The orange LED on the detector will be illuminated and the associated appliances will be activated. For example, the siren will be sounded or indication of movement detection will be shown on the controller. It implies that the unit is working properly. 3. Place the shading cap onto the ceiling-lens cover. 4. Check whether same results can be gained by walking into a protected area within coverage that is at your disposal. FIGURE 6f Note: To detect movements with detection coverage up to 360 degrees, simply reload the ceiling-lens cover without shading cap. No movements can be detected if the detector is reloaded with a shading cap which maintains 12 lens segments. (II) Configuration of Z-Wave Command The following information is for someone that has some experience in setting up a Z-Wave or someone that has computer software running a Z-Wave controller. Please get familiar with software of Z-Wave controller before getting started. Warm-Up Basic Set Level It will take approximately 2 minutes to warm up after battery has been connected. During this period, the detector beeps once every 3 seconds. When a long beep is sounded with red LED turns on steadily for 5 seconds, it implies warm-up procedure is completed and the detector is ready for detection. If PIR/light sensor of the detector has been triggered, the detector will send a Basic Set Command to the associated devices. For instance, the ambient illumination falls below a set detecting percentage of lux level, the detector sends a Basic Set Command to a Lamp Module and the Lamp Module turns on with 70% of brightness after receiving the commend. To adjust the value of Basic Set, please configure with the following value: Operation (I) General Operation Parameter number: 1 Size: Value: (indicating “Off”) 1-99, 0xFF (indicating “On” for binary switch, e.g. On/Off Module or Indicating “Dim Level” for multilevel switch device, e.g. Lamp Module) Mounting location is a critical factor for deciding the type of lens to be used for the detector. Please decide whether the detector is going to be wall-mounted or ceiling-mounted before the operation procedure is carried on. Note: The default value is 99, which implies that the associated device will turn on (or illuminate with highest brightness) after receiving the command. triggered Enabling/Disabling Sensor Detecting Function 20 seconds detected a movement (no response) detected a movement There might be times when users wish to suspend the detecting functions of the detector temporarily. To enable or disable PIR sensor and light sensor, please configure with the following value: triggered detected a movement FIGURE 7 Parameter number: 2 Size: Value: 0 (sensor disabled) 1 (sensor enabled) Note: The default value is set in 5, which implies that the detector can only be re-triggered after 5 seconds of interval. The orange LED is on for one second when the detector detects a trigger. Note: The default value is set in 1, which implies that the sensor detecting function is on. Reconnection of power supply will enable the sensor detecting function automatically. On-Off Duration Setting The function of on-off duration setting will be useful if the detector is connected with a module or lighting. The duration determines how long the detector should wait to send a Basic Set Command (Value = 0) to the associated device after sending a Basic Set Command (Value = Basic Set Level). For instance, a movement has been detected, the detector sends a Basic Set Command (Value = Basic Set Level) to a Lamp Module and the Lamp Module turns ON. After 100 seconds (the user can set the time between 5 to 3600 seconds), the Lamp Module turns off after receiving OFF command (i.e. Basic Set Command (Value = 0)). To adjust the on-off duration, please configure with the following value: Sensitivity Level (PIR sensor only) In order to provide a best efficiency of the detector, it is recommended to test the detector with movements from a farthest end of the coverage area at first time of use. If movements cannot be detected sensitively, simply adjust the sensitivity level. The sensitivity level is between 1 to 10. To adjust sensitivity level of the detector, please configure with the following value: Parameter number: 3 Size: Value (range): 1 ~ 10 (the larger the number, the higher the sensitivity) Parameter number: 6 Size: 2 (if value is set larger than 127) Value (range): 5 (sec) ~ 3600 (sec) Note: The default value is set in 6, which implies medium sensitivity. Re-trigger Interval Setting (PIR sensor only) light turns on detector is triggered This function is designed for setting the interval which allows PIR sensor to be re-triggered after the detector has been triggered. For example, the interval is set in 20 seconds. If a movement is detected, only wait after 20 seconds the detector can be triggered again if it detects another movement. During 20 seconds period, the detector will not detect (FIGURE 7). The time interval can be set between 5 seconds to 3600 seconds. To adjust time interval, please configure with the following value: light turns off 5 seconds detected a movement FIGURE 8 Note: The default value is set in 15, which implies that the detector will send an OFF command to associated appliances 15 seconds after they’ve been triggered. The green LED will stay on for 1 second after 15 seconds of interval. Parameter number: 4 Size: 2 (if value is set larger than 127) Value (range): 5 (sec) ~ 3600 (sec) Lux Level Setting The user can set a detecting percentage of lux level which determines when the light sensor will be activated. If percentage of lux level of ambient illumination falls below this percentage, and a person moves across or within the protected area, the detector will emit Z-Wave ON Command (i.e. Basic Set Command (Value = Basic Set Level)) to controller and activate connected modules and lighting. Percentage can be set between 1% to 100%. To adjust percentage of lux level, please configure with the following value: Note: The default value is 1 hour, which implies that the detector awakes and sends the Wakeup Notification Command to the set node every hour. Command Classes The Motion Detector supports Command Classes including… Parameter number: 5 Size: Value (range): 1 (%) ~ 100 (%) * COMMAND_CLASS_ALARM Note: The default value is set in 10, which implies 10% of lux level. * COMMAND_CLASS_BASIC * COMMAND_CLASS_BATTERY * COMMAND_CLASS_VERISON * COMMAND_CLASS_ASSOCIATION_V2 * COMMAND_CLASS_CONFIGURATION * COMMAND_CLASS_SENSOR_BINARY * COMMAND_CLASS_WAKE_UP_V2 * COMMAND_CLASS_MANUFACTURER_SPECIFIC Advanced Operation Low Battery Indication Troubleshooting When the battery level of the detector drops to a certain level, the detector will emit a low battery command to the node of Grouping 1; meanwhile, the detector will flash red LED once every 30 seconds. When this occurs, please replace the batteries as soon as possible. Symptom Possible Cause Recommendation LED cannot be displayed Run out of battery power Replace a new battery Check if reverse battery polarity Refit the battery with correct polarity Reposition its mounting location The detector not working The users can also enquire the battery status of the detector by sending a Battery Get Command via controller. Once the detector receives the command, it will return a Battery Report Command [Command Class Battery, Battery Report, Battery Level = 20%-100%] to the controller. If it displays with a message of “Battery Level = 0xFF (255)”, it implies that the detector is at low battery status. Two minutes warm up is completed, but cannot hear long beep sound (LED flashes on & off repeatedly at 2-second intervals) The detector does not stay awake for 10 minutes when power is first supplied Wakeup Command Class The detector stays in sleep status for the majority of time in order to conserve battery life. However, it can be woken up by either triggers of movement or set time. The unit stays in sleep status for the majority of time in order to conserve battery power. However, it can be woken up at specified intervals by setting WAKE_UP_INTERVAL_SET command by Z-Wave Controller. After the unit wakes up, it will send Wakeup Notification Command to the node ID that requires to be reported. The minimum and maximum wakeup interval is 60 seconds and 194 days respectively. Allowable interval among each wakeup interval is 1 second, such as 60, 61, 62 …. Check if mounting location is proper Check if the detector is out of order Check if detector is first power up or the detector has executed exclusion or reset procedure Check if detector is out of order Remove the source of interference Do not open the detector; send it to the local retailer. Please carry out inclusion procedure; make sure there are ID codes stored in the detector. Remove the batteries, press learning key several times to release the existing battery power and wait for 1 to 2 minutes before replacing the batteries. Specifications* Battery 1.5V AA size x 3 Battery Life 2 years** Operating Range Up to 30 meters line of sight (indoor) WARNING: Do not dispose of electrical appliances as unsorted municipal waste, use separate collection facilities. Contact your local government for information regarding the collection systems available. If electrical appliances are disposed of in landfills or dumps, hazardous substances can leak into the groundwater and get into the food chain, damaging your health and well-being. Warm Up Time About 2 minutes PIR Detection Coverage Wall-Mounted: Up to 10m x 110° (at 1.8m mounting height & 25°C) Ceiling-Mounted: Up to 5m x 360° (at 2.8m mounting height & 25°C) 908.42 MHz Operating Frequency When replacing old appliances with new ones, the retailer is legally obligated to take back your old appliance for disposal at least for free of charge. *Specifications are subject to change without notice **15 triggers per day 2013/10 Federal Communication Commission Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0.5 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Modify Date : 2013:10:07 16:53:09+08:00 Create Date : 2013:10:07 16:53:09+08:00 Format : application/pdf Title : Microsoft Word - Manual_SP814_ZDK4.54_20131007 Creator : 101199 Document ID : uuid:3df42717-3717-432e-8380-8971be039096 Instance ID : uuid:b026d216-713d-4437-b273-1d28acd9c1db Page Count : 7 Author : 101199EXIF Metadata provided by EXIF.tools