Everspring Industry Co TR003-01 Z-WAVE SERIES User Manual AD126 A501111257R

Everspring Industry Co Ltd Z-WAVE SERIES AD126 A501111257R

USERS MANUAL

Download: Everspring Industry Co TR003-01 Z-WAVE SERIES User Manual AD126 A501111257R
Mirror Download [FCC.gov]Everspring Industry Co TR003-01 Z-WAVE SERIES User Manual AD126 A501111257R
Document ID1142122
Application IDxh7z+KyhVj7XdHCkLZ87qw==
Document DescriptionUSERS MANUAL
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize8.08kB (100976 bits)
Date Submitted2009-07-21 00:00:00
Date Available2009-07-22 00:00:00
Creation Date2009-07-13 10:15:57
Producing SoftwareGPL Ghostscript 8.15
Document Lastmod2009-07-16 13:25:23
Document TitleMicrosoft Word - AD126_A501111257R.DOC
Document CreatorPScript5.dll Version 5.2
Document Author: 100060

Confidential Information of Everspring Industry Co. Ltd.
300 watts, the other should be 1200 watts. When the load of controllable outlet
consumes as 0 watts, the other will be 1500 watts.
AD126 LAMP MODULE
4. Turn the knob or switch on the lamp to the ON position.
TM
This plug-in Lamp Module is a transceiver which is a Z-Wave enabled device
TM
TM
and is fully compatible with any Z-Wave enabled network. Z-Wave enabled
TM
devices displaying the Z-Wave logo can also be used with it regardless of the
TM
manufacturer, and ours can also be used in other manufacturer’s Z-Wave
enabled networks. Inclusion of the Lamp module on other manufacturer’s
Wireless Controller menu allows remote On/Off control and dimming of lamps
connected. Each module is designed to act as a repeater. Repeaters will
re-transmit the RF signal to ensure that the signal is received by its intended
destination by routing the signal around obstacles and radio dead spots.
5. To manually turn ON the AD126 Lamp Module, press and release the
On/Off/Dim knob. The red indicator LED will turn ON, and the lamp plugged
into the AD126 Lamp Module will also turn ON.
6. To manually turn OFF the AD126 Lamp Module, simply press and release the
On/Off/Dim knob. The red indicator LED will turn OFF and the lamp plugged
into the AD126 Lamp Module will also turn OFF.
7. To manually dim the AD126 Lamp Module, press and hold the On/Off/Dim
knob until the desired lighting level has been reached.
Adding to Z-WaveTM Network
In the front casing, there is an On/Off/Dim knob which is used to carry out inclusion,
TM
exclusion or association. Put a Z-Wave
Wireless Controller into
inclusion/exclusion mode, press the knob on the Module to complete the
inclusion/exclusion process.
Note: Dimming an inductive load, such as a motor or a transformer, could
impair the dimmer and load attached as well.
Programming
The On/Off/Dim knob allows the user
- Turn on, off or dim the lamp attached
TM
- Include or exclude the module from the Z-Wave system
TM
- Control other Z-Wave enabled devices
Controllable outlet
Pass-through outlet
Advanced Operation
On /Off / Dim knob
TM
As long as any Z-Wave
command
Installation
1. Plug this Lamp module into a wall outlet near the lamp to be controlled.
enabled device that can send below mentioned alarm
(ALARM_REPORT, Alarm Type == 0x01, Alarm Level == 0x11)
2. Plug the lamp into the Lamp Module. There are two outlets at different sides of
AD126. The lamp plugged into the controllable outlet can be controlled by the
On/Off/Dim knob and remote controller, its maximum load is 300 watts. The
other side acts as a pass-through outlet which is non-controlled by the
On/Off/Dim knob and remote controller.
to the AD126 Lamp Module will enable its red indicator LED and the load plugged
into the AD126 Lamp Module to be on and off intermittently for 10 seconds
simultaneously.
Troubleshooting
3. Make sure the total load of both outlets cannot exceed 1500 watts which
means if the load of controllable outlet is changed; the other pass-through will
be altered accordingly. For instance, if the load of controllable outlet is about
Symptom
The Module not working and
LED off
Cause of Failure
1. The Module is not
plugged into the
Recommendation
1. Check power connections
2. Don’t open up the Module and
Confidential Information of Everspring Industry Co. Ltd.
The Module LED illuminating,
but cannot control the ON/OFF
Switch of the lamp attached
The Module LED illuminating,
but the Detector cannot control
the Module
electrical outlet
send it for repair.
properly
2. The Module break
down
Check if the lamp plugged Replace a new lamp
into the Module has
burned out
1. Carry out association
1. Not carry out
2. Wait for a while to re-try
association
2. Frequency interference
Mobile of end product
Federal Communication Commission Interference Statement
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct
the interference by one of the following measures:
Specification
Operating Voltage
Maximum Load
Minimum Load
Range
Frequency Range
120V/60Hz
300W, for incandescent lamps only
25W, for incandescent lamps only
Minimum 100 feet line of sight
908.42 MHz
A501111257R
** Specifications are subject to change and improvement without notice.
Compatible Devices
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
TM
The Everspring AD126 Lamp module is fully Z-Wave
device compatible.
TM
Homeowners with existing Z-Wave devices can easily add this device or more
in to complete a safety network firmly. The following Everspring devices are
compatible with AD126 Lamp module.
The following modules (sold separately) can be compatible with this device:
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the
party responsible for compliance could void the user's authority to operate
this equipment.
This transmitter must not be co-located or operating in conjunction with
any other antenna or transmitter.
SP103
PIR Detector
SM103
Door/Windows
Detector
ST812
ST814
ST815
Floor
Temperature/Humidity
Illuminatinon
Detector
Detector
Detector
IMPORTANT! To ensure better compatibility, only purchase Everspring or other
TM
manufactures’ Z-Wave Enabled devices .

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Print high-res
Author                          : 100060
Create Date                     : 2009:07:13 10:15:57Z
Modify Date                     : 2009:07:16 13:25:23+08:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Producer                        : GPL Ghostscript 8.15
Creator Tool                    : PScript5.dll Version 5.2
Metadata Date                   : 2009:07:16 13:25:23+08:00
Document ID                     : uuid:d354c568-40a7-4e55-bfde-fff2d3fcd154
Instance ID                     : uuid:eeb16c2b-4f17-47e1-9c63-74630ef50834
Format                          : application/pdf
Title                           : Microsoft Word - AD126_A501111257R.DOC
Creator                         : 100060
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: FU5TR003-01

Navigation menu