Ewig Macao Commercial Offshore 217S53M Thermo Sensor Transmitter User Manual 071 686173 001900

Ewig Industries Macao Commercial Offshore Limited Thermo Sensor Transmitter 071 686173 001900

Users Manual

Download: Ewig Macao Commercial Offshore 217S53M Thermo Sensor Transmitter User Manual 071 686173 001900
Mirror Download [FCC.gov]Ewig Macao Commercial Offshore 217S53M Thermo Sensor Transmitter User Manual 071 686173 001900
Document ID564045
Application IDGvu9h720ks8wAJHtbXrjiw==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize7.88kB (98546 bits)
Date Submitted2005-07-21 00:00:00
Date Available2005-07-21 00:00:00
Creation Date2005-06-15 14:31:55
Producing SoftwareCorel PDF Engine Version 1.0.0.458
Document Lastmod2005-06-15 14:31:55
Document Title071-686173-001900
Document CreatorCorelDRAW Version 12.0

EWIG Model 217 Standard Instruction Manual
This device could be sensitive to electrostatic discharge. If electrostatic discharge or malfunctioning
occurs, please reset this unit.
“Modifications not authorized by the manufacturer may void users authority to operate this device”
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment does not cause harmful interference to radio television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following
measures;
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
During the 3 minutes that the home receiver is seeking for sensor registration signal, remove the bracket
stand, release the screw at the rear of the sensor with a small screwdriver. Remove battery cover. Insert
2pcs AAA batteries into the battery compartment per direction shown. Channel 1 icon and the
temperature will be appear on the LCD of the receiving unit. If not hold the Tx button for 2 seconds on
the sensor to force out sensor registration signal. If registration is successful, close the battery cover and
tighten the screws.
Operation is subject to the following two conditions: (1) this device may not cause
interference, and (2) this device must accept any interference, including interference that
may cause undesired operation of the device.
-If registration is sucessful, a beep confirmation tone can be heard. If not, check the condition of the
AAA batteries, repeat the registration procedure again. Close the battery door and back cover and
tighten the screw on the sensor.
-To register sensor 2 and sensor 3:
Press and hold the “Channel” button for 2 seconds of the home
receiver to trigger sensor registration process. Insert battery for sensor 2, channel 2 icon and temperature will appear on the LCD of the receiving unit. Follow the same procedure to register sensor 3.
Note:
• The sensor will transmit the registration code automatically to complete the registration after the
batteries is just inserted. If the batteries have already inserted into the battery compartment , use a
pen to tap & hold the TX hold 2 seconds for Registration.
• If “---” appear on the outdoor chanel, move the sensor closer to the base unit. Repeat the
registration procedure again.
• The channel number have will be automatically assigned to the respective sensor in sequence of
registration. However, if all 3 RF sensors are already registered, you can perform the registration
again by selecting the desired channel and hold “Channel” 2 seconds to tell the base unit to accept
RF temperature signal, then hold “TX” 2 seconds on the remote sensor.
For wireless remote sensor with attachable probe only
If measurement of water, soil, or other liquid is desired, open the cover of the plug hole at the side of
the sensor and insert the probe plug. (optional)
Specifications
Recommended remote sensor operating range:
Sensor with LCD display
: -20°C to +50°C ( -4°F to +122°F)
Sensor without LCD display
: -20°C to +50°C ( -4°F to +122°F)
Detachable outdoor probe
: -50°C to +70°C (-58°F to +158°F)
Transmission range
: Maximum 30 meter, open area
Batteries
: DC 1.5V size AAA x 2 pcs
Battery life (status)
Remote sensor
Tranmission frequency
: Typical 6 months
: 433.92 Mhz
071-686173-001900

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 1
Create Date                     : D:20050615143155
Modify Date                     : D:20050615143155
Producer                        : Corel PDF Engine Version 1.0.0.458
Creator                         : CorelDRAW Version 12.0
Title                           : 071-686173-001900
EXIF Metadata provided by EXIF.tools
FCC ID Filing: N9Z217S53M

Navigation menu