Ewig Macao Commercial Offshore 381F01 Wireless Weather Center User Manual Unknown

Ewig Industries Macao Commercial Offshore Limited Wireless Weather Center Unknown

User manual

Download: Ewig Macao Commercial Offshore 381F01 Wireless Weather Center User Manual Unknown
Mirror Download [FCC.gov]Ewig Macao Commercial Offshore 381F01 Wireless Weather Center User Manual Unknown
Document ID117097
Application IDhdNBZ97BsWa1aG6kf8I6ww==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize7.97kB (99586 bits)
Date Submitted2000-09-14 00:00:00
Date Available2000-10-31 00:00:00
Creation Date0000-00-00 00:00:00
Producing SoftwareAcrobat PDFWriter 3.0 for Windows
Document Lastmod2000-09-11 16:36:27
Document TitleUnknown
Document Author: HKSTC Preferred User

FCC ID: N9Z381F01
Model 381F01
INSTRUCTION MANUAL
RF 433MHz Wireless Thermometer Clock
Wall Mount Hole
Min. Hold to
Seek Temp
Time/Snooze
Alarm Clock HI'GCJGF
Indoor Temp
Clock/Mann ,
Read Outdoor Temp
Channel l-3
Auto Scroll Light/Snooze
. Battery Door
Ilf’temor‘yn Temp Alen/ i
Alarm Set
Clear/Alarm Orr/Off ~' ' Table Stand
Thank you for purchasing the brand new RF Wireless Thermometer. Developed with the state-of-art
technology and digital electronics, this precision device provides instant readouts for time, indoor
temperature, 3-channel wireless outdoor temperatures plus a snooze alarm feature.
Battery Installation & Registration of Sensors:
Install batteries to the home receiver and then the remote sensor.
For home receiver
Use a small screwdriver to remove the screw lock on battery door. Insert two pieces size ‘AAA‘ batteries
into the battery compartment per direction shown, close the compartment door and tighten the screw.
After installing batteries to the home receiver the outdoor channel flash for 3 minutes indicating it is
seeking for temperature signal. Afler 3 minutes, you can still trigger the temperature seek by holding the
‘-’ button 2 seconds.
For wireless remote sensor
Release the screw at the bottom of the sensor with a small
screwdriver. Remove the back cover and the battery door.
Insert one 9V battery into the battery compartment per fif®
direction shown and close the battery door. Without
.. (D G) W 9
wartmg any longer, use a pen to push & hold 3 seconds a»
the ‘Tx’ hole once at the back of the remote sensor. W _
Channel 1 icon will appear and the temperature will be
decoded in a few seconds.
Sensor Transmitter
Note:
- To register Sensor 2 and Sensor 3:
Hold “SEEK" at the back of receiver 3 seconds, insert batteries to respective sensors, and follow
the same procedure as above.
- lf "--—” appear on the outdoor channel afler some period, move the remote sensor closer to the
base unit. Repeat the registration procedure if necessary.
Cclsius/ Fahrenheit:
Press ‘+‘ to select between °C or =‘F.
To set the Clock:
Press and hold ‘el'e’ key for 2 seconds to enter clock set. Press ‘+’ key to select 12/24 hr, press ‘O/e' to
confirm, press ‘+’ to adjust hour an ‘-’ to adjust minute, press ‘e/e’ to confirm and go to time zone
othet. Press ‘+, —‘ to adjust time zone offset, press ‘e/efi’ to confirm & exist.
Remark:
User cannot modify this product.
Daily Alarm:
Press the ‘ele’ key to read alarm time 5 seconds. While alarm time appear on screen, hold ‘ALERT’ 2
seconds to enter alarm set. Press ‘+’ to set hour and ‘-’ to set minute. Press ‘e/e’ to cont“ rm and exit
setting.
- press ‘CLEAR/L’ to turn daily alarm On and Off. Alarm bell icon 9 appears indicates daily alarm is
on.
- When alarm sounds, press ‘LlGHT/SNZ’ to trigger an 8-minute snooze, the alarm bell icon 9 blinks
indicating snooze is working. Press any other keys to stop alarm.
Extended Backlight: ‘
Press ‘LIGHT/SNZ’ once for a S-second extended green backlight.
Installation:
The home receiver can either be wall mounted or for desktop standing. Use a small screw to hang the
unit over the wall. For desktop standing, fit the table stand (supplied) and place the unit on a flat surface.
Place the outdoor sensor(s) away from direct sunlight and rainfall. If the outside temperature is extremely
low (below -10 “C), extend the 1m sensor cable and leave me sensor outside, keep the transmitter unit
indoors to avoid freezing-up the battery. Use the same way to measure temperature ot’icebox or pool.
Channel Auto Scroll:
Press the ‘CHANNEL’ key to select temperature channel 1, 2 or 3 (if2 or 3 sensors are registered). Hold
‘CHANNEL‘ key for 2 seconds for automatic scrolling remote sensor 1, Z & 3. Hold CHANNEL again to
exit auto scroll.
Max/ Min Temperature Memory:
Press ‘Max/Min’ to read maximum temperature 5 seconds, press again to read minimum temperature. To
clear the record, simply press ‘CLEAR/L’ while the respective value staying on screen.
Temperature Alert:
Press 'ALERT’ to turn temperature alert on and off. Hold ‘ALERT’ 2 seconds to enter setting. Press ‘+’.
‘ -‘ to select between lndoor/ Ch 1/ Ch 2/ Ch 3, press ‘ALERT‘ to confirm selection. Press ‘+’, ‘ -‘ to enter
Upper Temperature Limit value, the press ‘ALERT’ to confirm value, then press ‘+’, '-’ to enter Lower
Temperature Limit value, press ‘ALERT’ to finalize and exit. Each setting cycle can enter upper and
lower temperatures limit of a channel, repeat the above procedure to set temperature alert of other
channels.
Low Battery Indicators:
Replace the batteries whenever the low battery indicator appears on the respective channel. Follow the
registration procedure to register the remote sensor(s) after changing the battery.
Care of your Wireless Thermometer:
Wipe offdirt by using sofi damp cloth dipped with mild detergents, wipe offwith sofi dry cloth. Avoid
exposing the precision electronic device to extreme temperatures including prolonged exposure to direct
sunlight or wind chill. Handle the precision device with care, never drop on hard surface or subject to
severe shocks. The remote sensor is splash proof designed, never immerse into water or expose to heavy
l'fllllS.
Specifications:
lndoor temperature range : 0 0C to +50 °C (+32 °F to +122 °F)
Outdoor temperature range : -50 °C to + 70 °C (-58 °F to +158 °F)
Transmission range : 30 m, open area
Batteries : DC l.5V size AAA x 2 pcs (home receiver)
DC 9V 7; 1 pc (remote sensor)
Do Not Mix Old And New Baneries. Do Not er Alkaline. Standard ("l-63530 (4101900
(Carbonline), of Rechargeable(Nickel Caddmium) Batteries

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : No
Creator                         : 
Create Date                     : Monday, September 11, 2000 4:35:46 PM
Title                           : Unknown
Author                          : HKSTC Preferred User
Producer                        : Acrobat PDFWriter 3.0 for Windows
Subject                         : 
Modify Date                     : 2000:09:11 16:36:27
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: N9Z381F01

Navigation menu